SSSahel Solemanifard

Sahel Solemanifard

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sahel Solemanifard has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fault Arc Suppression Method With Elimination of Line Voltage Drop Influence for Flexible Distribution Networks Connected via Power Electronics

    by Bin-Long Zhang, Mou-Fa Guo, Chih-Min Lin, Mohammadreza Lak, Sahel Solemanifard, Qiteng Hong

    Single phase-to-ground (SPG) faults constitute the prevalent type of electrical failure in live distribution networks, posing critical threats including electrocution hazards, electrical fires, and widespread power supply disruptions. Power electronic converter can suppress the fault current and voltage, sustaining this suppression effect throughout the fault arc persistence period until arc extinction. However, not only does it consume additional resources, but the effect is also significantly affected by the line impedance voltage drop. This article analyzes the causes of line voltage drop and proposes an SPG fault arc suppression method for flexible distribution networks. The line voltage drop caused by the load currents of faulty feeder is eliminated by transferring the load currents via the employed flexible interconnection device during simultaneous fault arc suppression. The line voltage drop caused by the zero-sequence currents output from the device for fault arc suppression during simultaneous load current transfer is also eliminated, by only adopting the device arms connected to nonfaulty phase of the faulty feeder to output the zero-sequence currents. Extensive simulation study and experimental validation demonstrate that the fault current and voltage can be suppressed efficiently with a suppression rate of more than 98% in the case of different operating conditions.

  • An Adaptive Total Sliding Mode Control for Cascaded H-Bridge Multilevel Converters to Flexibly Suppress Ground Fault Arcs in Active Distribution Networks

    by Bin-Long Zhang, Mou-Fa Guo, Mohammadreza Lak, Chih-Min Lin, Sahel Solemanifard, Qiteng Hong

    Single phase-to-ground (SPG) faults are the most common faults in active distribution networks, which can cause hazardous situations and consequences, such as fires, electric shocks, and power outages. Power electronic converters using typical control methods, like proportional-integral (PI) control, backstepping control (BSC), and sliding mode control (SMC), can suppress the fault current and voltage until the fault arc disappears. However, these controllers are not adaptable to the various fault resistances and have long transient DC bias decay processes, resulting in the arc not being suppressed quickly and reliably. This paper proposes a novel adaptive total sliding mode control (ATSMC) for cascaded H-bridge multilevel converters (CHMC) to not only adapt to the uncertain and various fault resistances with a wide range but also eliminate the long-term transient DC bias decay processes, and the steady-state residual fault current and voltage can be suppressed to be smaller. The proposed method satisfies Lyapunov’s asymptotic stability and is also applicable to other power electronic converter topologies for suppressing fault arcs. The simulation study and experimental validation demonstrate the effectiveness of the proposed method in providing the above advantages and exhibit better overall performance, compared to those of PI, BSC, and SMC.


  • Open Access

    A Novel Discontinuous PWM Method With Hybrid Three-Step Commutation to Reduce Common-Mode Voltage for Direct Matrix Converter

    by Sahel Solemanifard, Cheng-Chin Hu, Tzung-Lin Lee, Mohammadreza Lak

    The conventional discontinuous pulsewidth modulation (PWM) can provide several advantages in a direct matrix converter (DMC), such as less switching number and less execution time for modulation signals' calculation. However, it suffers from high common-mode voltage (CMV), which may cause damage to the DMC-based system. This article proposes a novel discontinuous PWM (DPWM) method to not only mitigate CMV but also further improve the conversion efficiency. In this method, the switching sequence is obtained in a new way using two medium and two small input line voltages, increasing the conversion efficiency. Besides, the proposed DPWM employs a rotating vector instead of a zero vector, which causes the CMV to reduce by 50% compared with the conventional DPWM. Notably, the proposed DPWM provides the above advantages while maintaining low total harmonic distortion (THD). Simulations and experiments have been conducted to verify the proposed DPWM method's effectiveness. The results of these tests support the claims made in the paper regarding the reduction of CMV, improved efficiency, and low THD.


  • Open Access

    A Novel Three-Step Commutation Method for Direct Matrix Converter Free From Inrush Current and Voltage Error

    by Sahel Solemanifard, Yan-Xing Chen, Mohammadreza Lak, Tzung-Lin Lee

    The direct matrix converter is a well-accepted topology for AC/AC converters. The commutation method should be considered in the direct matrix converter topology to avoid failures caused by the input short circuit and output open circuit during commutations. The conventional three-step commutation method of input voltage not only avoids the aforementioned failures but also removes errors between actual and command output voltage. However, it increases the number of hard switching and the flow of inrush current originating from the mismatch between the turn-on and turn-off delay time of switches. This paper proposes a new three-step commutation method that eliminates inrush current and reduces the number of hard switching. In this way, the conversion efficiency is improved, and circuit hazards caused by inrush current are over. Meanwhile, the proposed commutation method keeps the advantage of canceling the voltage error of conventional three-step commutation. Noteworthy that the proposed commutation method is introduced based on a novel fixed-slope direct duty ratio PWM simplifying the practical implementation. The performance and effectiveness of the proposed method have been verified by simulation and experimental results.