Drew Thompson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Drew Thompson has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Bon Ki Ku
Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH), Health Effects Laboratory Division (HELD), 1090 Tusculum Ave, MS-R7, Cincinnati, Ohio 45226, USA
2 shared publications - Chen Wang
Health Effects Laboratory Division, National Institute for Occupational Safety and Health
2 shared publications - Kabir Rishi
Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH), 1090 Tusculum Avenue, Cincinnati 45226, Ohio, United States
2 shared publications Alan Dozier
Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH) Centers for Disease Control and Prevention (CDC),1090 Tusculum Ave,Cincinnati, Ohio 45226, United States
1 shared publication- Alexander N. Osiptsov
Institute of Mechanics, Moscow State University, Moscow, Russia
1 shared publication Artur Lutfurakhmanov
North Dakota State University, Fargo, ND
1 shared publication
Latest Publications
- 23 August 2025
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 70 (1)
Compatibility of engineered stone materials with tetrahydrofuran processing for crystalline silica analysis by XRD
This study investigated the compatibility of Tetrahydrofuran (THF) dissolution, following the procedures outlined in NIOSH Method 7500 and the similar OSHA ID-142 method, as a sample preparation technique for respirable crystalline silica (RCS) analysis in engineered stone materials compared to the muffle furnace (MF) ashing method. Our results revealed considerable variability in RCS content across different batches of engineered stone tested, underscoring the inherent material heterogeneity in engineered stone products. A statistically significant underestimation of RCS concentrations was observed when using THF dissolution for Stone A (polyester-based) samples collected on 47 mm polyvinyl chloride (PVC) filters, particularly at lower analyte loadings. In contrast, no statistically significant differences in RCS measurement were found between THF dissolution and MF ashing for the other 3 stone types, including one laboratory-synthetic material. The observed discrepancy in Stone A is likely attributed to the interaction of THF with its polyester resin binder, leading to swelling of the filter matrix and forming a non-volatile residue. This residue may physically entrap silica particles, hindering their complete recovery and subsequent quantification by X-ray diffraction (XRD). The suitability of THF processing as a sample preparation method is therefore highly dependent on the specific composition of the engineered stone. Based on these findings, MF ashing is recommended as the more reliable and universally applicable sample preparation method for engineered stone samples, especially those containing polyester resin binders. Caution should be exercised when considering THF dissolution for RCS analysis in engineered stones due to the potential for significant underestimation of actual RCS values, which could have implications for exposure assessments and regulatory compliance.
- 23 August 2025
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 70 (1)
Compatibility of engineered stone materials with tetrahydrofuran processing for crystalline silica analysis by XRD
This study investigated the compatibility of Tetrahydrofuran (THF) dissolution, following the procedures outlined in NIOSH Method 7500 and the similar OSHA ID-142 method, as a sample preparation technique for respirable crystalline silica (RCS) analysis in engineered stone materials compared to the muffle furnace (MF) ashing method. Our results revealed considerable variability in RCS content across different batches of engineered stone tested, underscoring the inherent material heterogeneity in engineered stone products. A statistically significant underestimation of RCS concentrations was observed when using THF dissolution for Stone A (polyester-based) samples collected on 47 mm polyvinyl chloride (PVC) filters, particularly at lower analyte loadings. In contrast, no statistically significant differences in RCS measurement were found between THF dissolution and MF ashing for the other 3 stone types, including one laboratory-synthetic material. The observed discrepancy in Stone A is likely attributed to the interaction of THF with its polyester resin binder, leading to swelling of the filter matrix and forming a non-volatile residue. This residue may physically entrap silica particles, hindering their complete recovery and subsequent quantification by X-ray diffraction (XRD). The suitability of THF processing as a sample preparation method is therefore highly dependent on the specific composition of the engineered stone. Based on these findings, MF ashing is recommended as the more reliable and universally applicable sample preparation method for engineered stone samples, especially those containing polyester resin binders. Caution should be exercised when considering THF dissolution for RCS analysis in engineered stones due to the potential for significant underestimation of actual RCS values, which could have implications for exposure assessments and regulatory compliance.
- Open Access
- 10 December 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (51) , 50308-50317
Release of Crystalline Silica Nanoparticles during Engineered Stone Fabrication
Inhalation exposure to respirable crystalline silica (RCS) during the fabrication of engineered stone-based kitchen countertops has been on the rise in recent years and has become a significant occupational health problem in the United States and globally. Little is known about the presence of nanocrystalline silica (NCS), i.e., particles below 100 nm. We present a methodology to quantify the crystalline silica content in the sub-100 nm size fraction of the aerosol released during engineered stone fabrication using X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy. Aerosol was generated in a test chamber designed per EN 1093-3 and sampled using cascade impactors. XRD and FTIR analysis showed the presence of both α-quartz (15-60%) and cristobalite (10-50%) polymorphs in all size fractions. With increasing particle size, the cristobalite content increased. Seventy percent of the total aerosol mass in the sub-100 nm fraction was found to be crystalline silica, qualitatively confirmed by electron diffraction and electron energy loss spectroscopy. The presence of other minerals was detected in all size fractions; no polymeric resin binder was detected in the sub-100 nm fraction. Although the sub-100 nm fraction was about 1% of the aerosol mass, it accounted for 4-24% of the aerosol surface area based on the total lung deposition. If the surface area is a more relevant exposure metric, the assessment of the efficacy of current engineering control systems using mass as an exposure metric may not provide adequate protection.
- 10 December 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (51) , 50308-50317
Open AccessRelease of Crystalline Silica Nanoparticles during Engineered Stone Fabrication
Inhalation exposure to respirable crystalline silica (RCS) during the fabrication of engineered stone-based kitchen countertops has been on the rise in recent years and has become a significant occupational health problem in the United States and globally. Little is known about the presence of nanocrystalline silica (NCS), i.e., particles below 100 nm. We present a methodology to quantify the crystalline silica content in the sub-100 nm size fraction of the aerosol released during engineered stone fabrication using X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy. Aerosol was generated in a test chamber designed per EN 1093-3 and sampled using cascade impactors. XRD and FTIR analysis showed the presence of both α-quartz (15-60%) and cristobalite (10-50%) polymorphs in all size fractions. With increasing particle size, the cristobalite content increased. Seventy percent of the total aerosol mass in the sub-100 nm fraction was found to be crystalline silica, qualitatively confirmed by electron diffraction and electron energy loss spectroscopy. The presence of other minerals was detected in all size fractions; no polymeric resin binder was detected in the sub-100 nm fraction. Although the sub-100 nm fraction was about 1% of the aerosol mass, it accounted for 4-24% of the aerosol surface area based on the total lung deposition. If the surface area is a more relevant exposure metric, the assessment of the efficacy of current engineering control systems using mass as an exposure metric may not provide adequate protection.
- 1 August 2018
- Published by Elsevier in Building and Environment
- Vol. 141, 206-214
Evaluation of different discharging methods on HVAC electret filter media
- 1 August 2018
- Published by Elsevier in Building and Environment
- Vol. 141, 206-214
Evaluation of different discharging methods on HVAC electret filter media
- 1 January 2009
- Published by ASME International
- p. 223-232
Aerosol Flow Through a Micro-Capillary
A combined theoretical/experimental study of micron size aerosol flows through micro-capillaries of diameter about 100 μm and length about 1 cm is presented. It is shown that under proper conditions at a relatively high velocity of about 100 m/s such an aerosol flow reveals a new manifestation of microfluidics: the Saffman force acting on aerosol particles in gas flowing through a micro-capillary becomes significant thereby causing noticeable migration of particles toward the center line of the capillary. This finding opens up new opportunities for aerosol focusing, which is in stark contrast to the classical aerodynamic focusing methodologies where only particle inertia and the Stokes force of gas-particle interaction are typically used to control particle trajectories. A mathematical model for aerosol flow through a micro-capillary accounting for complicated interactions between particles and carrier gas is presented. This model describes the experimental observables obtained via shadowgraphy for aerosol beams exiting micro-capillaries. It is further shown that it is possible to design a micro-capillary system capable of generating a Collimated Aerosol Beam (CAB) in which aerosol particles stay very close to a capillary center line. The performance of such a CAB system for direct-write fabrication on a substrate is demonstrated. The lines deposited by CAB for direct-write fabrication are shown to exhibit widths of less than 5 μm — superior to ink-jet. Materials deposition based upon directed aerosol flow has the potential of finding application in the fields of flexible electronics, sensors, and solar cells. In this paper, the genesis of a new materials deposition method termed Collimated Aerosol Beam Direct-Write (CAB-DW) is discussed.
- 1 January 2009
- Published by ASME International
- p. 223-232
Aerosol Flow Through a Micro-Capillary
A combined theoretical/experimental study of micron size aerosol flows through micro-capillaries of diameter about 100 μm and length about 1 cm is presented. It is shown that under proper conditions at a relatively high velocity of about 100 m/s such an aerosol flow reveals a new manifestation of microfluidics: the Saffman force acting on aerosol particles in gas flowing through a micro-capillary becomes significant thereby causing noticeable migration of particles toward the center line of the capillary. This finding opens up new opportunities for aerosol focusing, which is in stark contrast to the classical aerodynamic focusing methodologies where only particle inertia and the Stokes force of gas-particle interaction are typically used to control particle trajectories. A mathematical model for aerosol flow through a micro-capillary accounting for complicated interactions between particles and carrier gas is presented. This model describes the experimental observables obtained via shadowgraphy for aerosol beams exiting micro-capillaries. It is further shown that it is possible to design a micro-capillary system capable of generating a Collimated Aerosol Beam (CAB) in which aerosol particles stay very close to a capillary center line. The performance of such a CAB system for direct-write fabrication on a substrate is demonstrated. The lines deposited by CAB for direct-write fabrication are shown to exhibit widths of less than 5 μm — superior to ink-jet. Materials deposition based upon directed aerosol flow has the potential of finding application in the fields of flexible electronics, sensors, and solar cells. In this paper, the genesis of a new materials deposition method termed Collimated Aerosol Beam Direct-Write (CAB-DW) is discussed.