Colette M. McKay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Colette M. McKay has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Hugh J. McDermott
Department of Otolaryngology, The University of Melbourne, Melbourne, Australia
8 shared publications - Darren Mao
Bionics Institute, Fitzroy, VIC 3065, Australia
7 shared publications - Maureen J. Shader
Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, USA
6 shared publications - Tommy Peng
The Bionics Institute, Melbourne, Australia
6 shared publications Darren Mao
The Bionics Institute, 41 Victoria Parade, Fitzroy, 3065, Victoria, Australia; Department of Medical Bionics, the University of Melbourne, Grattan Street, Parkville, 3010, Victoria, Australia
5 shared publicationsMica Haneman
4 shared publications
Latest Publications
- Open Access
- 20 May 2026
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 433, 110804
Correction of connectivity induced by autocorrelation and filtering in resting state functional near-infrared spectroscopy data
- 20 May 2026
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 433, 110804
Open AccessCorrection of connectivity induced by autocorrelation and filtering in resting state functional near-infrared spectroscopy data
- Open Access
- 15 December 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (51)
Dynamic functional connectivity following cochlear implantation: Predicting speech outcomes and exploring brain network dynamics
Cochlear implants (CIs) have transformed hearing restoration for individuals with severe or profound hearing loss, yet outcomes vary widely and remain difficult to predict. This study introduces an approach by examining the temporal dynamics of brain functional networks postimplantation to identify predictors of outcomes and explore brain plasticity. Twenty-nine CI candidates and 23 normal-hearing individuals participated. Functional near-infrared spectroscopy measured brain activity during audio-only and visual-only speech tasks at 1 mo and 1 y postimplantation, with speech understanding assessed after 1 y. Brain community dynamics were analyzed using multilayer modularity and network switching rates to capture temporal reorganization. Lower network switching rates shortly after implantation were associated with better long-term speech performance. Evidence of cross-modal plasticity—reflecting preimplant neural reorganization—was observed in early recordings, indicated by increased module allegiance between the posterior temporal (PT) region and visual cortices, which diminished after 1 y. Additionally, interhemispheric connectivity in the PT showed significant improvement between sessions, reducing disparities between CI users and normal-hearing individuals. These findings highlight dynamic functional connectivity as a meaningful neural correlate of outcome variability, with potential relevance for guiding personalized rehabilitation strategies and optimizing auditory and speech outcomes.
- 15 December 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (51)
Open AccessDynamic functional connectivity following cochlear implantation: Predicting speech outcomes and exploring brain network dynamics
Cochlear implants (CIs) have transformed hearing restoration for individuals with severe or profound hearing loss, yet outcomes vary widely and remain difficult to predict. This study introduces an approach by examining the temporal dynamics of brain functional networks postimplantation to identify predictors of outcomes and explore brain plasticity. Twenty-nine CI candidates and 23 normal-hearing individuals participated. Functional near-infrared spectroscopy measured brain activity during audio-only and visual-only speech tasks at 1 mo and 1 y postimplantation, with speech understanding assessed after 1 y. Brain community dynamics were analyzed using multilayer modularity and network switching rates to capture temporal reorganization. Lower network switching rates shortly after implantation were associated with better long-term speech performance. Evidence of cross-modal plasticity—reflecting preimplant neural reorganization—was observed in early recordings, indicated by increased module allegiance between the posterior temporal (PT) region and visual cortices, which diminished after 1 y. Additionally, interhemispheric connectivity in the PT showed significant improvement between sessions, reducing disparities between CI users and normal-hearing individuals. These findings highlight dynamic functional connectivity as a meaningful neural correlate of outcome variability, with potential relevance for guiding personalized rehabilitation strategies and optimizing auditory and speech outcomes.
- Open Access
- 15 March 2025
- Published by Center for Open Science in PsyArXiv
Longitudinal speech understanding outcomes in cochlear implant recipients are associated with neural factors identified using psychophysics and functional brain imaging
Objective: There remain large variations in cochlear implant outcomes which are poorly explained by patient history factors. This study aims to better understand how different neural limitations along the auditory processing pathway are associated with speech understanding outcomes.Design: 43 cochlear implant recipients (44 ears) were recruited to participate in a longitudinal study to evaluate limitations at various locations along the auditory processing pathway. At the periphery, intra-cochlear neural health was estimated using focused psychophysical thresholds. Higher-order across-electrode intensity discrimination ability was assessed using psychophysical “spectral tilt”. At the cortical level, cross-modal activation of the auditory cortex was assessed using functional near infra-red spectroscopy. Speech understanding outcomes were evaluated in competing multi-talker babble noise at one-year post device switch-on.Results: We found that greater abilities to discriminate smaller across-electrode stimulation intensities (R2 = 0.138, p = 0.047) and smaller cross-modal activations of the auditory cortex (R2 = 0.216, p = 0.01) were significantly associated with better speech understanding outcomes in cochlear implant recipients. Furthermore, both measures contributed significantly to better predict speech understanding outcomes in a multiple regression model (Adj R2 = 0.312, p = 0.009).Conclusion: The results suggest that recipient-specific neural factors contribute significantly towards individual differences in speech understanding outcomes. Different recipients can be affected by different limitations, which can be identified using these tests, and therefore lead to potential patient-specific methods to improve their speech understanding.
- 15 March 2025
- Published by Center for Open Science in PsyArXiv
Open AccessLongitudinal speech understanding outcomes in cochlear implant recipients are associated with neural factors identified using psychophysics and functional brain imaging
Objective: There remain large variations in cochlear implant outcomes which are poorly explained by patient history factors. This study aims to better understand how different neural limitations along the auditory processing pathway are associated with speech understanding outcomes.Design: 43 cochlear implant recipients (44 ears) were recruited to participate in a longitudinal study to evaluate limitations at various locations along the auditory processing pathway. At the periphery, intra-cochlear neural health was estimated using focused psychophysical thresholds. Higher-order across-electrode intensity discrimination ability was assessed using psychophysical “spectral tilt”. At the cortical level, cross-modal activation of the auditory cortex was assessed using functional near infra-red spectroscopy. Speech understanding outcomes were evaluated in competing multi-talker babble noise at one-year post device switch-on.Results: We found that greater abilities to discriminate smaller across-electrode stimulation intensities (R2 = 0.138, p = 0.047) and smaller cross-modal activations of the auditory cortex (R2 = 0.216, p = 0.01) were significantly associated with better speech understanding outcomes in cochlear implant recipients. Furthermore, both measures contributed significantly to better predict speech understanding outcomes in a multiple regression model (Adj R2 = 0.312, p = 0.009).Conclusion: The results suggest that recipient-specific neural factors contribute significantly towards individual differences in speech understanding outcomes. Different recipients can be affected by different limitations, which can be identified using these tests, and therefore lead to potential patient-specific methods to improve their speech understanding.
- Open Access
- 15 March 2025
- Published by Center for Open Science in PsyArXiv
Auditory- and visual-speech evoked activation of the superior temporal gyrus contralateral to the cochlear implant predicts speech understanding outcomes
Objective: Speech discrimination outcomes vary widely in cochlear implant recipients, but reasons for this variability are not well explained by patient history factors alone. Neuroplastic reorganisation after both deafness and cochlear implant switch-on can affect how new recipients adapt to electrical hearing. In this study, we evaluate the associations between speech understanding outcomes and stimulus evoked activation of cortical language processing areas. Design: 43 newly implanted post-lingually deaf adult cochlear implant recipients were recruited to the longitudinal study. Participants attended two research visits: the first conducted within one-month of device switch-on, and the second conducted one-year after device switch-on. At each visit, we evaluated speech understanding outcomes in noise and cortical activation using functional near infrared spectroscopy during a passive listening task, during which a story was told in either an auditory or visual-speech (lip-reading) condition. Results: We found statistically significant correlations between poorer speech understanding outcomes one year post device switch-on and large activations in the superior temporal gyrus contralateral to the device in response to both auditory- (F(1, 30) = 11.297, R2 = 0.274, p = 0.002) and visual-speech (F(1, 30) = 18.216, R2 = 0.38, p < 0.001) stimuli tested within one-month of switch-on. However, these significant associations were not observed using activation data from the one-year mark. Furthermore, we found no association between changes in activation of the superior temporal gyrus contralateral to the device and changes in speech understanding outcomes over the first year of implant use. Conclusions: Our evidence highlights that neuroplastic changes which occur following adult-onset deafness play an important role in how cochlear implant recipients adapt to their devices after switch-on. The relationship between neuroimaging measures made within one-month after device switch-on and speech understanding outcomes at one-year can potentially enable triaging of recipients to improve clinical management of implant recipients.
- 15 March 2025
- Published by Center for Open Science in PsyArXiv
Open AccessAuditory- and visual-speech evoked activation of the superior temporal gyrus contralateral to the cochlear implant predicts speech understanding outcomes
Objective: Speech discrimination outcomes vary widely in cochlear implant recipients, but reasons for this variability are not well explained by patient history factors alone. Neuroplastic reorganisation after both deafness and cochlear implant switch-on can affect how new recipients adapt to electrical hearing. In this study, we evaluate the associations between speech understanding outcomes and stimulus evoked activation of cortical language processing areas. Design: 43 newly implanted post-lingually deaf adult cochlear implant recipients were recruited to the longitudinal study. Participants attended two research visits: the first conducted within one-month of device switch-on, and the second conducted one-year after device switch-on. At each visit, we evaluated speech understanding outcomes in noise and cortical activation using functional near infrared spectroscopy during a passive listening task, during which a story was told in either an auditory or visual-speech (lip-reading) condition. Results: We found statistically significant correlations between poorer speech understanding outcomes one year post device switch-on and large activations in the superior temporal gyrus contralateral to the device in response to both auditory- (F(1, 30) = 11.297, R2 = 0.274, p = 0.002) and visual-speech (F(1, 30) = 18.216, R2 = 0.38, p < 0.001) stimuli tested within one-month of switch-on. However, these significant associations were not observed using activation data from the one-year mark. Furthermore, we found no association between changes in activation of the superior temporal gyrus contralateral to the device and changes in speech understanding outcomes over the first year of implant use. Conclusions: Our evidence highlights that neuroplastic changes which occur following adult-onset deafness play an important role in how cochlear implant recipients adapt to their devices after switch-on. The relationship between neuroimaging measures made within one-month after device switch-on and speech understanding outcomes at one-year can potentially enable triaging of recipients to improve clinical management of implant recipients.
- Open Access
- 24 January 2025
- Published by SAGE Publications in Trends in Hearing
- Vol. 29
Measuring Speech Discrimination Ability in Sleeping Infants Using fNIRS—A Proof of Principle
This study used functional near-infrared spectroscopy (fNIRS) to measure aspects of the speech discrimination ability of sleeping infants. We examined the morphology of the fNIRS response to three different speech contrasts, namely “Tea/Ba,” “Bee/Ba,” and “Ga/Ba.” Sixteen infants aged between 3 and 13 months old were included in this study and their fNIRS data were recorded during natural sleep. The stimuli were presented using a nonsilence baseline paradigm, where repeated standard stimuli were presented between the novel stimuli blocks without any silence periods. The morphology of fNIRS responses varied between speech contrasts. The data were fit with a model in which the responses were the sum of two independent and concurrent response mechanisms that were derived from previously published fNIRS detection responses. These independent components were an oxyhemoglobin (HbO)-positive early-latency response and an HbO-negative late latency response, hypothesized to be related to an auditory canonical response and a brain arousal response, respectively. The goodness of fit of the model with the data was high with median goodness of fit of 81%. The data showed that both response components had later latency when the left ear was the test ear ( p < .05) compared to the right ear and that the negative component, due to brain arousal, was smallest for the most subtle contrast, “Ga/Ba” ( p = .003).
- 24 January 2025
- Published by SAGE Publications in Trends in Hearing
- Vol. 29
Open AccessMeasuring Speech Discrimination Ability in Sleeping Infants Using fNIRS—A Proof of Principle
This study used functional near-infrared spectroscopy (fNIRS) to measure aspects of the speech discrimination ability of sleeping infants. We examined the morphology of the fNIRS response to three different speech contrasts, namely “Tea/Ba,” “Bee/Ba,” and “Ga/Ba.” Sixteen infants aged between 3 and 13 months old were included in this study and their fNIRS data were recorded during natural sleep. The stimuli were presented using a nonsilence baseline paradigm, where repeated standard stimuli were presented between the novel stimuli blocks without any silence periods. The morphology of fNIRS responses varied between speech contrasts. The data were fit with a model in which the responses were the sum of two independent and concurrent response mechanisms that were derived from previously published fNIRS detection responses. These independent components were an oxyhemoglobin (HbO)-positive early-latency response and an HbO-negative late latency response, hypothesized to be related to an auditory canonical response and a brain arousal response, respectively. The goodness of fit of the model with the data was high with median goodness of fit of 81%. The data showed that both response components had later latency when the left ear was the test ear ( p < .05) compared to the right ear and that the negative component, due to brain arousal, was smallest for the most subtle contrast, “Ga/Ba” ( p = .003).
- Open Access
Cross-modal Functional Plasticity after Cochlear-implantation
Objective: Despite evidence that cross-modal effects after hearing loss and cochlear implantation are primarily conveyed through synaptic gain and efficacy rather than reorganized fiber tracts, few studies have assessed cross-modal functional connectivity (CMFC) to evaluate plasticity. This study, inspired by the psychophysiological interactions (PPI) method, addresses its limitations and provides a robust approach to evaluating task-induced CMFC. Design: Twenty-two post-lingually deafened, newly implanted adult cochlear implant (CI) recipients with severe hearing loss in the contralateral ear and 17 normal-hearing (NH) subjects participated. The experiment included audio-only and visual-only speech tasks, with resting-state FC as a baseline. Functional near-infrared spectroscopy (fNIRS) measured brain imaging data one month and one year post-implantation. CI users’ speech understanding performance was evaluated one year after implantation. Results: A negative correlation was found between average contralateral task-induced CMFC and speech outcomes, particularly in links from the angular gyrus (AG), both one month and one year post-activation. Plastic changes showed higher task-induced CMFC in AG compared to the superior temporal gyrus (STG), aligning with neural efficiency principles. Task-induced CMFC remained elevated in CI users compared to NH cohorts even after one year. Conclusion: Task-induced CMFC can serve as a significant marker of cross-modal plasticity and speech performance in CI recipients, indicating increased reliance on cross-modal processing in one year after implantation.
Open AccessCross-modal Functional Plasticity after Cochlear-implantation
Objective: Despite evidence that cross-modal effects after hearing loss and cochlear implantation are primarily conveyed through synaptic gain and efficacy rather than reorganized fiber tracts, few studies have assessed cross-modal functional connectivity (CMFC) to evaluate plasticity. This study, inspired by the psychophysiological interactions (PPI) method, addresses its limitations and provides a robust approach to evaluating task-induced CMFC. Design: Twenty-two post-lingually deafened, newly implanted adult cochlear implant (CI) recipients with severe hearing loss in the contralateral ear and 17 normal-hearing (NH) subjects participated. The experiment included audio-only and visual-only speech tasks, with resting-state FC as a baseline. Functional near-infrared spectroscopy (fNIRS) measured brain imaging data one month and one year post-implantation. CI users’ speech understanding performance was evaluated one year after implantation. Results: A negative correlation was found between average contralateral task-induced CMFC and speech outcomes, particularly in links from the angular gyrus (AG), both one month and one year post-activation. Plastic changes showed higher task-induced CMFC in AG compared to the superior temporal gyrus (STG), aligning with neural efficiency principles. Task-induced CMFC remained elevated in CI users compared to NH cohorts even after one year. Conclusion: Task-induced CMFC can serve as a significant marker of cross-modal plasticity and speech performance in CI recipients, indicating increased reliance on cross-modal processing in one year after implantation.
- Open Access
Resting-state Functional Connectivity Predicts Cochlear-Implant Speech Outcomes
Background: Cochlear implants (CIs) have revolutionized hearing restoration for individuals with severe or profound hearing loss. However, a substantial and unexplained variability persists in CI outcomes, even when considering subject-specific factors such as age and the duration of deafness. In this study, we explore the utility of resting-state functional near-infrared spectroscopy (fNIRS) recordings to predict speech understanding outcomes before and after CI implantation. Our hypothesis revolves around resting-state functional connectivity (FC) as a reflection of brain plasticity post-hearing loss and implantation. Specifically, we hypothesized that the average clustering coefficient in resting FC networks can capture this variation among CI users. Methods: Twenty-two cochlear implant candidates participated in this study. Resting-state fNIRS data were collected pre-implantation and at one month, three months, and one year post-implantation. Speech understanding performance was assessed using CNC words in quiet and BKB sentences in noise one year post-implantation. Resting-state functional connectivity networks were constructed using regularized partial correlation, and the average clustering coefficient was measured in the signed weighted networks as a predictive measure for implantation outcomes. Results: Our findings demonstrate a significant correlation between the average clustering coefficient in resting-state functional networks and speech understanding outcomes. Importantly, our analysis reveals that this measure provides unique information not accounted for by subject-specific factors such as age and duration of deafness. Conclusion: This approach utilizes an easily deployable resting-state functional brain imaging metric to predict speech understanding outcomes in implant recipients. The results indicate that the average clustering coefficient, both pre and post implantation, correlates with speech understanding outcomes.
Open AccessResting-state Functional Connectivity Predicts Cochlear-Implant Speech Outcomes
Background: Cochlear implants (CIs) have revolutionized hearing restoration for individuals with severe or profound hearing loss. However, a substantial and unexplained variability persists in CI outcomes, even when considering subject-specific factors such as age and the duration of deafness. In this study, we explore the utility of resting-state functional near-infrared spectroscopy (fNIRS) recordings to predict speech understanding outcomes before and after CI implantation. Our hypothesis revolves around resting-state functional connectivity (FC) as a reflection of brain plasticity post-hearing loss and implantation. Specifically, we hypothesized that the average clustering coefficient in resting FC networks can capture this variation among CI users. Methods: Twenty-two cochlear implant candidates participated in this study. Resting-state fNIRS data were collected pre-implantation and at one month, three months, and one year post-implantation. Speech understanding performance was assessed using CNC words in quiet and BKB sentences in noise one year post-implantation. Resting-state functional connectivity networks were constructed using regularized partial correlation, and the average clustering coefficient was measured in the signed weighted networks as a predictive measure for implantation outcomes. Results: Our findings demonstrate a significant correlation between the average clustering coefficient in resting-state functional networks and speech understanding outcomes. Importantly, our analysis reveals that this measure provides unique information not accounted for by subject-specific factors such as age and duration of deafness. Conclusion: This approach utilizes an easily deployable resting-state functional brain imaging metric to predict speech understanding outcomes in implant recipients. The results indicate that the average clustering coefficient, both pre and post implantation, correlates with speech understanding outcomes.
- Open Access
- 1 January 2024
- Published by SAGE Publications in Trends in Hearing
- Vol. 28
Two Independent Response Mechanisms to Auditory Stimuli Measured with Functional Near-Infrared Spectroscopy in Sleeping Infants
This study investigated the morphology of the functional near-infrared spectroscopy (fNIRS) response to speech sounds measured from 16 sleeping infants and how it changes with repeated stimulus presentation. We observed a positive peak followed by a wide negative trough, with the latter being most evident in early epochs. We argue that the overall response morphology captures the effects of two simultaneous, but independent, response mechanisms that are both activated at the stimulus onset: one being the obligatory response to a sound stimulus by the auditory system, and the other being a neural suppression effect induced by the arousal system. Because the two effects behave differently with repeated epochs, it is possible to mathematically separate them and use fNIRS to study factors that affect the development and activation of the arousal system in infants. The results also imply that standard fNIRS analysis techniques need to be adjusted to take into account the possibilities of multiple simultaneous brain systems being activated and that the response to a stimulus is not necessarily stationary.
- 1 January 2024
- Published by SAGE Publications in Trends in Hearing
- Vol. 28
Open AccessTwo Independent Response Mechanisms to Auditory Stimuli Measured with Functional Near-Infrared Spectroscopy in Sleeping Infants
This study investigated the morphology of the functional near-infrared spectroscopy (fNIRS) response to speech sounds measured from 16 sleeping infants and how it changes with repeated stimulus presentation. We observed a positive peak followed by a wide negative trough, with the latter being most evident in early epochs. We argue that the overall response morphology captures the effects of two simultaneous, but independent, response mechanisms that are both activated at the stimulus onset: one being the obligatory response to a sound stimulus by the auditory system, and the other being a neural suppression effect induced by the arousal system. Because the two effects behave differently with repeated epochs, it is possible to mathematically separate them and use fNIRS to study factors that affect the development and activation of the arousal system in infants. The results also imply that standard fNIRS analysis techniques need to be adjusted to take into account the possibilities of multiple simultaneous brain systems being activated and that the response to a stimulus is not necessarily stationary.
- Open Access
- 20 December 2023
- Published by Center for Open Science in PsyArXiv
Comparing patient-specific variations in intra-cochlea neural health estimated using psychophysical thresholds and panoramic electrically evoked compound action potentials (PECAPs)
Purpose: Variations in neural survival along the cochlear implant electrode array leads to off-place listening, resulting in poorer speech understanding outcomes for recipients. Therefore, it is important to develop and compare clinically viable tests to identify these patient-specific intra-cochlea neural differences. Methods: We derived the neural health along the electrode array for a group of experienced adult implant recipients using two methods: the difference between psychophysical detection thresholds in bipolar vs. monopolar mode and the Panoramic electrically-evoked compound action potential method (PECAP). We hypothesised that: 1) the two neural measures will correlate at both the individual and group level; and 2) a larger variation in neural health along the electrode array will be associated with poorer speech understanding outcomes. Results: At the individual level, the two neural measures correlated significantly (p<0.05) for 5 out of 15 participants. At the group level, we observed a weak but significant correlation (R2=0.111, p<0.001) between the two neural measures. While a larger variation in neural measures derived from psychophysical thresholds was associated with lower phoneme speech scores (R2=0.499, p<0.01), no significant association was found between variations in PECAP’s neural health estimates and phoneme speech scores (R2=0.082, p=0.366). Conclusion: Our evidence suggests that both methods likely quantify a shared underlying neural basis, hypothesised to be the neural health along the cochlear implant array. The differences between the two measures may be attributed to differences in stimulus rate or loudness used to elicit responses and/or a combination of non-peripheral and non-neural confounds.
- 20 December 2023
- Published by Center for Open Science in PsyArXiv
Open AccessComparing patient-specific variations in intra-cochlea neural health estimated using psychophysical thresholds and panoramic electrically evoked compound action potentials (PECAPs)
Purpose: Variations in neural survival along the cochlear implant electrode array leads to off-place listening, resulting in poorer speech understanding outcomes for recipients. Therefore, it is important to develop and compare clinically viable tests to identify these patient-specific intra-cochlea neural differences. Methods: We derived the neural health along the electrode array for a group of experienced adult implant recipients using two methods: the difference between psychophysical detection thresholds in bipolar vs. monopolar mode and the Panoramic electrically-evoked compound action potential method (PECAP). We hypothesised that: 1) the two neural measures will correlate at both the individual and group level; and 2) a larger variation in neural health along the electrode array will be associated with poorer speech understanding outcomes. Results: At the individual level, the two neural measures correlated significantly (p<0.05) for 5 out of 15 participants. At the group level, we observed a weak but significant correlation (R2=0.111, p<0.001) between the two neural measures. While a larger variation in neural measures derived from psychophysical thresholds was associated with lower phoneme speech scores (R2=0.499, p<0.01), no significant association was found between variations in PECAP’s neural health estimates and phoneme speech scores (R2=0.082, p=0.366). Conclusion: Our evidence suggests that both methods likely quantify a shared underlying neural basis, hypothesised to be the neural health along the cochlear implant array. The differences between the two measures may be attributed to differences in stimulus rate or loudness used to elicit responses and/or a combination of non-peripheral and non-neural confounds.
- Open Access
- 20 June 2023
- Published by Center for Open Science in PsyArXiv
A reliable, accurate, and clinic-friendly objective test of speech sound detection and discrimination in sleeping infants
One of the most basic measures of hearing device validation and outcome is the ability of the aided person to successfully use their device for verbal communication. For infants, an additional outcome measure is whether the device is facilitating spoken language development. Unfortunately, there is currently no clinically-adopted or reliable objective measure for speech understanding or for language development in individual infants, and we must rely upon behavioural observations or tasks that require the infant to first reach a sufficient developmental stage. This inability to verify whether an early-fitted hearing device will optimally facilitate language development is a potential cause of sub-optimal or delayed early intervention, which can result in permanent language disability, and reduced quality of life. This paper outlines the development of a new objective and reliable method to measure speech detection and speech discrimination in sleeping infants using a technology - functional near-infrared spectroscopy (fNIRS) – that is not yet available in audiology clinics. The culmination of research efforts to optimise the test methods and to devise novel analysis algorithms to reliably and automatically detect brain responses in sleeping infants is a test and analysis method with clinically acceptable accuracy (95% specificity and greater than 78-100% sensitivity). We have shown that the methods described here are now mature enough to bring into clinics for the benefit of infants and their audiological managers.
- 20 June 2023
- Published by Center for Open Science in PsyArXiv
Open AccessA reliable, accurate, and clinic-friendly objective test of speech sound detection and discrimination in sleeping infants
One of the most basic measures of hearing device validation and outcome is the ability of the aided person to successfully use their device for verbal communication. For infants, an additional outcome measure is whether the device is facilitating spoken language development. Unfortunately, there is currently no clinically-adopted or reliable objective measure for speech understanding or for language development in individual infants, and we must rely upon behavioural observations or tasks that require the infant to first reach a sufficient developmental stage. This inability to verify whether an early-fitted hearing device will optimally facilitate language development is a potential cause of sub-optimal or delayed early intervention, which can result in permanent language disability, and reduced quality of life. This paper outlines the development of a new objective and reliable method to measure speech detection and speech discrimination in sleeping infants using a technology - functional near-infrared spectroscopy (fNIRS) – that is not yet available in audiology clinics. The culmination of research efforts to optimise the test methods and to devise novel analysis algorithms to reliably and automatically detect brain responses in sleeping infants is a test and analysis method with clinically acceptable accuracy (95% specificity and greater than 78-100% sensitivity). We have shown that the methods described here are now mature enough to bring into clinics for the benefit of infants and their audiological managers.