MSMaureen J. Shader

Maureen J. Shader

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maureen J. Shader has a total of 171 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Beyond Single Biomarkers: A Graph Neural Network Framework for Multivariable Prediction of Clinical Outcomes from Brain Imaging

    by Jamal Esmaelpoor, Abdolrahim Kadkhodamohammadi, Tommy Peng, Beth Jelfs, Darren Mao, Abdollah Ghafouri, Maureen J. Shader

    Understanding brain–behavior relationships requires models capturing the distributed, interactive, and multiscale nature of neural systems. Traditional univariate approaches and single-biomarker models are inherently limited in this context, as they fail to represent dependencies across regions and the hierarchical organization of brain networks. In this study, we propose a graph-based multivariable framework for brain imaging analysis that integrates key organizational principles of brain function—including segregation, integration, modularity, and temporal dynamics—within a unified graph neural network architecture. The framework represents brain data as hierarchical graphs, where node features encode regional activation and temporal variability, and graph structure captures interactions within and between functional modules. The proposed approach is evaluated using functional near-infrared spectroscopy (fNIRS) data as a case study, where subject-specific brain graphs are constructed from task-based recordings acquired shortly after cochlear implant activation to predict speech understanding outcomes one year later. Under leave-one-subject-out validation, the model demonstrates strong predictive performance (R = 0.73, p < 0.001), outperforming previously reported single-biomarker approaches. Perturbation-based analyses further show that predictions are driven by distributed patterns of activity and interaction across regions and modalities, rather than isolated features. These results illustrate the capability of the proposed framework to capture complex brain organization and highlight its potential as a generalizable platform for multivariable analysis and prediction in neuroimaging applications beyond the specific clinical use case considered here.

  • Open Access

    Group-level test–retest reliability assessment using systemic physiology augmented functional near-infrared spectroscopy during a passive-listening task

    by Abigail A. Mollison, Eric R. Rodriguez, Abigail Metzger, Maureen J. Shader

    SignificanceFunctional near-infrared spectroscopy (fNIRS) is a valuable neuroimaging technique for auditory-research tasks. However, fNIRS data are influenced by systemic-physiological processes, resulting in noisier signal quality that may compromise test–retest reliability. fNIRS reliability may also be influenced by changes in cap placement across sessions.AimWe investigated the effectiveness of systemic-physiology denoising methods on the test–retest reliability of group-level fNIRS data during a passive-listening task.ApproachFifteen participants completed two identical sessions of a passive-listening task; source-detector optode locations were digitized for each session. Different denoising methods were compared to investigate the effect of systemic-physiology correction on the consistency of across-session hemodynamic response amplitudes. Test–retest reliability for each method was assessed using the intraclass correlation coefficient (ICC). Changes in optode and channel locations across sessions were calculated to track shifts in cap placement.ResultsResults revealed significant speech-evoked activity in bilateral auditory cortices following stimuli presentation. Group-level test–retest reliability metrics demonstrated good reliability across two identical test sessions. Accounting for the influence of systemic physiology resulted in improved reliability. Slight variations in optode placement did not significantly affect signal repeatability.ConclusionThis study supports the use of fNIRS for group-level task-evoked studies, demonstrating that systemic-physiology denoising methods can modestly improve test–retest reliability.


  • Open Access

    Dynamic functional connectivity following cochlear implantation: Predicting speech outcomes and exploring brain network dynamics

    by Jamal Esmaelpoor, Tommy Peng, Beth Jelfs, Darren Mao, Maureen J. Shader, Colette M. McKay

    Cochlear implants (CIs) have transformed hearing restoration for individuals with severe or profound hearing loss, yet outcomes vary widely and remain difficult to predict. This study introduces an approach by examining the temporal dynamics of brain functional networks postimplantation to identify predictors of outcomes and explore brain plasticity. Twenty-nine CI candidates and 23 normal-hearing individuals participated. Functional near-infrared spectroscopy measured brain activity during audio-only and visual-only speech tasks at 1 mo and 1 y postimplantation, with speech understanding assessed after 1 y. Brain community dynamics were analyzed using multilayer modularity and network switching rates to capture temporal reorganization. Lower network switching rates shortly after implantation were associated with better long-term speech performance. Evidence of cross-modal plasticity—reflecting preimplant neural reorganization—was observed in early recordings, indicated by increased module allegiance between the posterior temporal (PT) region and visual cortices, which diminished after 1 y. Additionally, interhemispheric connectivity in the PT showed significant improvement between sessions, reducing disparities between CI users and normal-hearing individuals. These findings highlight dynamic functional connectivity as a meaningful neural correlate of outcome variability, with potential relevance for guiding personalized rehabilitation strategies and optimizing auditory and speech outcomes.


  • Open Access

    Sentence recall and neurophysiological effects of the “2-Sentence Problem” under time compression in younger and older listeners

    by Victoria C. Sinfield, Sandy Snyder, Yunjie Tong, Maureen J. Shader

  • Open Access

    Publisher Correction: fNIRS reproducibility varies with data quality, analysis pipelines, and researcher experience

    by Meryem A. Yücel, Robert Luke, Rickson C. Mesquita, Alexander von Lühmann, David M. A. Mehler, Michael Lührs, Jessica Gemignani, Androu Abdalmalak, Franziska Albrecht, Iara de Almeida Ivo, et al.


  • Top Cited Papers
    Open Access

    fNIRS reproducibility varies with data quality, analysis pipelines, and researcher experience

    by Meryem A. Yücel, Robert Luke, Rickson C. Mesquita, Alexander von Lühmann, David M. A. Mehler, Michael Lührs, Jessica Gemignani, Androu Abdalmalak, Franziska Albrecht, Iara de Almeida Ivo, et al.

    As data analysis pipelines grow more complex in brain imaging research, understanding how methodological choices affect results is essential for ensuring reproducibility and transparency. This is especially relevant for functional Near-Infrared Spectroscopy (fNIRS), a rapidly growing technique for assessing brain function in naturalistic settings and across the lifespan, yet one that still lacks standardized analysis approaches. In the fNIRS Reproducibility Study Hub (FRESH) initiative, we asked 38 research teams worldwide to independently analyze the same two fNIRS datasets. Despite using different pipelines, nearly 80% of teams agreed on group-level results, particularly when hypotheses were strongly supported by literature. Teams with higher self-reported analysis confidence, which correlated with years of fNIRS experience, showed greater agreement. At the individual level, agreement was lower but improved with better data quality. The main sources of variability were related to how poor-quality data were handled, how responses were modeled, and how statistical analyses were conducted. These findings suggest that while flexible analytical tools are valuable, clearer methodological and reporting standards could greatly enhance reproducibility. By identifying key drivers of variability, this study highlights current challenges and offers direction for improving transparency and reliability in fNIRS research.


  • Open Access

    Longitudinal speech understanding outcomes in cochlear implant recipients are associated with neural factors identified using psychophysics and functional brain imaging

    by Tommy Peng, Colette McKay, Maureen Shader, Robert Luke, Linty McDonald, Jamal Esmaelpoor, Mica Haneman, Katherine R. Henshall

    Objective: There remain large variations in cochlear implant outcomes which are poorly explained by patient history factors. This study aims to better understand how different neural limitations along the auditory processing pathway are associated with speech understanding outcomes.Design: 43 cochlear implant recipients (44 ears) were recruited to participate in a longitudinal study to evaluate limitations at various locations along the auditory processing pathway. At the periphery, intra-cochlear neural health was estimated using focused psychophysical thresholds. Higher-order across-electrode intensity discrimination ability was assessed using psychophysical “spectral tilt”. At the cortical level, cross-modal activation of the auditory cortex was assessed using functional near infra-red spectroscopy. Speech understanding outcomes were evaluated in competing multi-talker babble noise at one-year post device switch-on.Results: We found that greater abilities to discriminate smaller across-electrode stimulation intensities (R2 = 0.138, p = 0.047) and smaller cross-modal activations of the auditory cortex (R2 = 0.216, p = 0.01) were significantly associated with better speech understanding outcomes in cochlear implant recipients. Furthermore, both measures contributed significantly to better predict speech understanding outcomes in a multiple regression model (Adj R2 = 0.312, p = 0.009).Conclusion: The results suggest that recipient-specific neural factors contribute significantly towards individual differences in speech understanding outcomes. Different recipients can be affected by different limitations, which can be identified using these tests, and therefore lead to potential patient-specific methods to improve their speech understanding.

  • Open Access

    Auditory- and visual-speech evoked activation of the superior temporal gyrus contralateral to the cochlear implant predicts speech understanding outcomes

    by Tommy Peng, Colette McKay, Jamal Esmaelpoor, Katherine R. Henshall, Maureen Shader, Robert Luke, Linty McDonald, Mica Haneman

    Objective: Speech discrimination outcomes vary widely in cochlear implant recipients, but reasons for this variability are not well explained by patient history factors alone. Neuroplastic reorganisation after both deafness and cochlear implant switch-on can affect how new recipients adapt to electrical hearing. In this study, we evaluate the associations between speech understanding outcomes and stimulus evoked activation of cortical language processing areas. Design: 43 newly implanted post-lingually deaf adult cochlear implant recipients were recruited to the longitudinal study. Participants attended two research visits: the first conducted within one-month of device switch-on, and the second conducted one-year after device switch-on. At each visit, we evaluated speech understanding outcomes in noise and cortical activation using functional near infrared spectroscopy during a passive listening task, during which a story was told in either an auditory or visual-speech (lip-reading) condition. Results: We found statistically significant correlations between poorer speech understanding outcomes one year post device switch-on and large activations in the superior temporal gyrus contralateral to the device in response to both auditory- (F(1, 30) = 11.297, R2 = 0.274, p = 0.002) and visual-speech (F(1, 30) = 18.216, R2 = 0.38, p < 0.001) stimuli tested within one-month of switch-on. However, these significant associations were not observed using activation data from the one-year mark. Furthermore, we found no association between changes in activation of the superior temporal gyrus contralateral to the device and changes in speech understanding outcomes over the first year of implant use. Conclusions: Our evidence highlights that neuroplastic changes which occur following adult-onset deafness play an important role in how cochlear implant recipients adapt to their devices after switch-on. The relationship between neuroimaging measures made within one-month after device switch-on and speech understanding outcomes at one-year can potentially enable triaging of recipients to improve clinical management of implant recipients.

  • Open Access

    Intra-subject test-retest reliability for auditory-evoked functional near-infrared spectroscopy responses: effects of systemic physiology correction

    by Victoria C. Sinfield, Dalton Aaker, Abigail Metzger, Yunjie Tong, Maureen J. Shader

    Functional near-infrared spectroscopy (fNIRS) is a non-invasive neuroimaging tool for measuring hemodynamic changes associated with task-evoked neural activity. It relies on the foundational principle of neuro-vascular coupling—a link between neural activity and the delivery of oxygen via a complex vascular mechanism.1,2 Specifically, fNIRS measures changes in the concentration of oxygenated and deoxygenated hemoglobin in cortical blood, exploiting the absorption and scattering characteristics of near-infrared light when passing through biological tissue.3 Since its development for research applications in humans in the 1970s, fNIRS has been used in a variety of research contexts in both adults and children.4