Abhishek Patnaik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abhishek Patnaik has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- David Pommerenke
Graz University of Technology
11 shared publications - Kaustav Ghosh
Juniper Networks Company, Sunnyvale, CA, USA
4 shared publications - Ahmad Hosseinbeig
EMC Laboratory, Missouri University of Science and Technology, Rolla, MO 65401 USA. He is now with the Department of EMC Design Engineering, Apple, Cupertino, CA 95014 USA
3 shared publications - Daryl G. Beetner
EMC Laboratory, Missouri University of Science and Technology, Rolla, MO, USA
3 shared publications - Javad Soleiman Meiguni
Amazon Lab126, Sunnyvale, CA, USA
3 shared publications - Satyajeet Shinde
Apple Inc., Cupertino, CA, USA
3 shared publications
Latest Publications
- 15 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (4) , 1555-1562
Measurement-Based Validation of Integrated Circuit Transient Electromagnetic Event Sensors
Determining the components or coupling paths responsible for soft failures during transient testing is challenging because the components are hidden within the product and because measuring internal voltages or currents during a transient test may not be practical. Adding cables to make voltage or current measurements may be difficult and may alter the test results. To overcome this problem, in this article, two compact sensors are designed to measure the peak over or undervoltage on a trace or pin during a transient electromagnetic event. One sensor uses an analog-to-digital converter to store the peak voltage digitally and the other sensor uses an external capacitor to store an analog measure of the peak voltage for a period of time. The sensors are designed to wirelessly transmit the peak level to a remote receiver using the frequency-modulated electric and magnetic fields so that no cables or other changes to the system are needed. The proof-of-concept of the sensors was implemented in an integrated circuit using 180 nm technology. The sensor performance is characterized by direct injection and by using them to detect the peak voltage on a universal serial bus (USB) cable during a cable-guided transient event. Both sensors successfully detected and transmitted the peak level of the event.
- 15 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (4) , 1555-1562
Measurement-Based Validation of Integrated Circuit Transient Electromagnetic Event Sensors
Determining the components or coupling paths responsible for soft failures during transient testing is challenging because the components are hidden within the product and because measuring internal voltages or currents during a transient test may not be practical. Adding cables to make voltage or current measurements may be difficult and may alter the test results. To overcome this problem, in this article, two compact sensors are designed to measure the peak over or undervoltage on a trace or pin during a transient electromagnetic event. One sensor uses an analog-to-digital converter to store the peak voltage digitally and the other sensor uses an external capacitor to store an analog measure of the peak voltage for a period of time. The sensors are designed to wirelessly transmit the peak level to a remote receiver using the frequency-modulated electric and magnetic fields so that no cables or other changes to the system are needed. The proof-of-concept of the sensors was implemented in an integrated circuit using 180 nm technology. The sensor performance is characterized by direct injection and by using them to detect the peak voltage on a universal serial bus (USB) cable during a cable-guided transient event. Both sensors successfully detected and transmitted the peak level of the event.
- 15 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (4) , 1601-1610
System-Level EMI of an Artificial Router System With Multiple Radiators: Prediction and Validation
In a multimodule system, an increase in the number of radiating optical modules will increase the electromagnetic emissions. This article investigates the scaled tendency of the emissions in a router system loaded with hundreds of optical modules. An artificial router mimicking the real system was built to investigate this tendency. A patch antenna array mimics the radiation of the optical modules. It can be excited in in-phase and random-phase configurations. The measurement data verifies the theoretical analysis and the prediction from a statistical method without performing hundreds of different experiments on a real router. Assuming that all radiators are radiating at the same frequency and have similar radiation pattern with random phases, the average of the maximal directivity of the system will saturate if the number of radiators (N) is larger than 14. Furthermore, the average of the maximal electric field radiated will increase following a 10 log $_{10}$ N (dB) tendency.- 15 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (4) , 1601-1610
System-Level EMI of an Artificial Router System With Multiple Radiators: Prediction and Validation
In a multimodule system, an increase in the number of radiating optical modules will increase the electromagnetic emissions. This article investigates the scaled tendency of the emissions in a router system loaded with hundreds of optical modules. An artificial router mimicking the real system was built to investigate this tendency. A patch antenna array mimics the radiation of the optical modules. It can be excited in in-phase and random-phase configurations. The measurement data verifies the theoretical analysis and the prediction from a statistical method without performing hundreds of different experiments on a real router. Assuming that all radiators are radiating at the same frequency and have similar radiation pattern with random phases, the average of the maximal directivity of the system will saturate if the number of radiators (N) is larger than 14. Furthermore, the average of the maximal electric field radiated will increase following a 10 log $_{10}$ N (dB) tendency.- 7 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (4) , 1007-1016
Measurement Techniques to Identify Soft Failure Sensitivity to ESD
Electrostatic discharge (ESD)-induced soft failures are a critical issue for electronic systems as the failures are mostly found after the hardware design is completed. Any changes applied to the hardware may delay the project. Diagnostic tools capable of identifying soft failure-induced malfunctions in an early stage of product design help to reduce the risk of late stage ESD-induced project delays. In many cases, soft failures can be directly observed by the user interface, system crash, or other obvious indicators. However, in an early product design stage the operation system may be marginal and applications may not be available. To improve the ability to detect soft failure critical design choices, this paper presents several methods to identify ESD-induced changes which may not be observable via direct observation. These methods include the observation of ac or dc currents, monitoring dc voltages, capturing near fields and processing them via short-term fast fourier transform (FFT), wavelet transformation, down mixing to audible range, and monitoring for latch-up via thermal imaging. The paper introduces the basis of each method, shows examples, and compares them for their detection ability.
- 7 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (4) , 1007-1016
Measurement Techniques to Identify Soft Failure Sensitivity to ESD
Electrostatic discharge (ESD)-induced soft failures are a critical issue for electronic systems as the failures are mostly found after the hardware design is completed. Any changes applied to the hardware may delay the project. Diagnostic tools capable of identifying soft failure-induced malfunctions in an early stage of product design help to reduce the risk of late stage ESD-induced project delays. In many cases, soft failures can be directly observed by the user interface, system crash, or other obvious indicators. However, in an early product design stage the operation system may be marginal and applications may not be available. To improve the ability to detect soft failure critical design choices, this paper presents several methods to identify ESD-induced changes which may not be observable via direct observation. These methods include the observation of ac or dc currents, monitoring dc voltages, capturing near fields and processing them via short-term fast fourier transform (FFT), wavelet transformation, down mixing to audible range, and monitoring for latch-up via thermal imaging. The paper introduces the basis of each method, shows examples, and compares them for their detection ability.
- 16 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (2) , 415-424
EMI Prediction of Multiple Radiators
A new method is developed to predict the scaling of the electromagnetic interference from a large system if similar subsystems are added. The method gives the predicted emission from multiple radiators as well as the level of certainty of the estimation. The proposed statistical approach is based on the phased array antenna theory and Monte Carlo simulation for a router with several line cards (N) and optical modules inserted. To validate the method, a large router with 498 optical modules with an unwanted radiation at 10.31 GHz was investigated in two different cases: the same frequency and different frequency per radiating subsystem. Several statistical experiments were performed for the proposed problem. The effect of phase and amplitude variations over the radiators is reported in this paper. The method is useful when it is not practical to assemble extraordinary amounts of identical hardware in a product installation. The results indicate the existence of a 10 log N (dB) tendency for the maximum electric field emission in a system radiating at the same frequency with random phase distribution over the radiators. For different frequency subsystems, the slope of the maximum electric field emission is lower than the 10 log N (dB) formula.
- 16 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (2) , 415-424
EMI Prediction of Multiple Radiators
A new method is developed to predict the scaling of the electromagnetic interference from a large system if similar subsystems are added. The method gives the predicted emission from multiple radiators as well as the level of certainty of the estimation. The proposed statistical approach is based on the phased array antenna theory and Monte Carlo simulation for a router with several line cards (N) and optical modules inserted. To validate the method, a large router with 498 optical modules with an unwanted radiation at 10.31 GHz was investigated in two different cases: the same frequency and different frequency per radiating subsystem. Several statistical experiments were performed for the proposed problem. The effect of phase and amplitude variations over the radiators is reported in this paper. The method is useful when it is not practical to assemble extraordinary amounts of identical hardware in a product installation. The results indicate the existence of a 10 log N (dB) tendency for the maximum electric field emission in a system radiating at the same frequency with random phase distribution over the radiators. For different frequency subsystems, the slope of the maximum electric field emission is lower than the 10 log N (dB) formula.
- 16 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (2) , 612-616
Growth of Radiated Emission in Multi-Modular Systems
- 16 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (2) , 612-616
Growth of Radiated Emission in Multi-Modular Systems
- 13 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (5) , 1231-1239
A Transient Event Sensor for Efficient System-Level ESD Testing
Testing and debugging of immunity issues is challenging in part because it is not known which components inside a system are impacted by an immunity test or at what level. Attaching cables and probes to determine stress voltages and currents within a system is time consuming and can alter the test results. Sensors are proposed for measuring the peak stress voltage experienced within a system during a transient immunity test. The peak current can also be found when the sensor is placed across a transient voltage suppressor with a known I-V curve. The peak level is transmitted wirelessly to a receiver outside the system using frequency-modulated magnetic or electric fields, thus allowing multiple measurements to be made without opening the enclosure or otherwise modifying the system. Two sensing circuits are proposed: one that stores the peak voltage on an external capacitor and the other that uses an analog-to-digital converter to store the level in a register. The capabilities of the circuits were validated with a combination of SPICE and electromagnetic simulations when the sensor was placed inside a typical cell phone enclosure. Simulations demonstrate that the sensors can accurately detect the peak transient voltage and transmit the level to an external receiver.
- 13 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (5) , 1231-1239
A Transient Event Sensor for Efficient System-Level ESD Testing
Testing and debugging of immunity issues is challenging in part because it is not known which components inside a system are impacted by an immunity test or at what level. Attaching cables and probes to determine stress voltages and currents within a system is time consuming and can alter the test results. Sensors are proposed for measuring the peak stress voltage experienced within a system during a transient immunity test. The peak current can also be found when the sensor is placed across a transient voltage suppressor with a known I-V curve. The peak level is transmitted wirelessly to a receiver outside the system using frequency-modulated magnetic or electric fields, thus allowing multiple measurements to be made without opening the enclosure or otherwise modifying the system. Two sensing circuits are proposed: one that stores the peak voltage on an external capacitor and the other that uses an analog-to-digital converter to store the level in a register. The capabilities of the circuits were validated with a combination of SPICE and electromagnetic simulations when the sensor was placed inside a typical cell phone enclosure. Simulations demonstrate that the sensors can accurately detect the peak transient voltage and transmit the level to an external receiver.
- 19 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (5) , 1263-1269
Systematic Evaluation of Soft Failures in System-Level ESD Transient Events
A system such as a human-assisting robot consists of many subsystems such as sensors, display, motors, and control. When an electrostatic discharge (ESD) occurs, it can disrupt the normal operation of any subsystem. This paper analyzes such events beginning at the tribo-charging down to the sensor disruption. The rolling wheels charge the robot, and a discharge occurs when it reaches the charging station. Based on the charge voltage, the discharge current is simulated using a simple switch model along with the loop impedance which limits the current. In multiple steps, the discharge current couples to the sensor. This coupling is represented as S-parameters obtaining the noise voltage at the sensor. This noise voltage is compared to the sensor's noise sensitivity threshold to reproduce the disruptive event. The model is validated with measurements. The simulation model can help system designers assess ESD risks without damaging hardware as well as efficiently design filtering components and effective on-board ESD protection.
- 19 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (5) , 1263-1269
Systematic Evaluation of Soft Failures in System-Level ESD Transient Events
A system such as a human-assisting robot consists of many subsystems such as sensors, display, motors, and control. When an electrostatic discharge (ESD) occurs, it can disrupt the normal operation of any subsystem. This paper analyzes such events beginning at the tribo-charging down to the sensor disruption. The rolling wheels charge the robot, and a discharge occurs when it reaches the charging station. Based on the charge voltage, the discharge current is simulated using a simple switch model along with the loop impedance which limits the current. In multiple steps, the discharge current couples to the sensor. This coupling is represented as S-parameters obtaining the noise voltage at the sensor. This noise voltage is compared to the sensor's noise sensitivity threshold to reproduce the disruptive event. The model is validated with measurements. The simulation model can help system designers assess ESD risks without damaging hardware as well as efficiently design filtering components and effective on-board ESD protection.
- 5 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (6) , 2011-2018
Terminal Modeling of DC–DC Converters With Stochastic Behavior
A terminal model is a common method to create equivalent models of dc-dc converters in order to predict conducted emissions. In this paper, a characterization method for converters with stochastic behavior is presented. The averaged and maximized spectra of the measured voltages and currents are used to create the model. The phase information is obtained using a dedicated reference channel. After the equivalent source was determined, the actual induced noise voltage at the test load was compared to that predicted by the model with the averaged and maximized spectra to estimate its accuracy. The results indicate that the agreement with the direct measurement is between 10 dB and 100 MHz.
- 5 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (6) , 2011-2018
Terminal Modeling of DC–DC Converters With Stochastic Behavior
A terminal model is a common method to create equivalent models of dc-dc converters in order to predict conducted emissions. In this paper, a characterization method for converters with stochastic behavior is presented. The averaged and maximized spectra of the measured voltages and currents are used to create the model. The phase information is obtained using a dedicated reference channel. After the equivalent source was determined, the actual induced noise voltage at the test load was compared to that predicted by the model with the averaged and maximized spectra to estimate its accuracy. The results indicate that the agreement with the direct measurement is between 10 dB and 100 MHz.
- 3 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (4) , 1053-1060
An On-Chip Detector of Transient Stress Events
Testing and debugging of electrostatic discharge (ESD) or electrical fast transient issues in modern electronic systems can be challenging. The following paper describes the design of an on-chip circuit that detects and stores the occurrence of a fast transient stress event at the ESD protection structures in an input/output pad. Measurements and simulations of a test chip in 90 nm technology show that this circuit can accurately detect and record the presence of a transient stress event with a peak current as low as 0.9 A or a duration as short as 1 ns, and that the detector works well across typical temperature and process variations. The small size of the detector allows it to be used effectively in low-cost commercial integrated circuits. The detector was tested in a system-level environment and successfully records transient events. The importance of simulating with intelligent approximations of the system parasitics is described and demonstrated in measurements. An improved detector is discussed, which performs better in terms of process variations.
- 3 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (4) , 1053-1060
An On-Chip Detector of Transient Stress Events
Testing and debugging of electrostatic discharge (ESD) or electrical fast transient issues in modern electronic systems can be challenging. The following paper describes the design of an on-chip circuit that detects and stores the occurrence of a fast transient stress event at the ESD protection structures in an input/output pad. Measurements and simulations of a test chip in 90 nm technology show that this circuit can accurately detect and record the presence of a transient stress event with a peak current as low as 0.9 A or a duration as short as 1 ns, and that the detector works well across typical temperature and process variations. The small size of the detector allows it to be used effectively in low-cost commercial integrated circuits. The detector was tested in a system-level environment and successfully records transient events. The importance of simulating with intelligent approximations of the system parasitics is described and demonstrated in measurements. An improved detector is discussed, which performs better in terms of process variations.
- 22 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (6) , 1769-1776
Radiated EMI Estimation From DC–DC Converters With Attached Cables Based on Terminal Equivalent Circuit Modeling
An equivalent two terminal model based on the Thevenin equivalents describes the common mode (CM) currents on the input and output side of two widely used types of dc-to-dc power converters—buck and boost. Thus, it describes a nonlinear circuit by a linear equivalent circuit. The maximized spectrum of the CM currents is extracted for converters with stochastic signals using a novel characterization procedure. The extracted Thevenin model is used in co-simulation combined with a full-wave electromagnetic solver to predict the radiated emissions from the system consisting of the shielded dc–dc converters with attached cables and a DC brushless motor as load. The results using the terminal model agree well with the measurements providing that the actual CM loads are within the range of CM loads used while obtaining the Thevenin equivalent circuit.
- 22 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 60 (6) , 1769-1776
Radiated EMI Estimation From DC–DC Converters With Attached Cables Based on Terminal Equivalent Circuit Modeling
An equivalent two terminal model based on the Thevenin equivalents describes the common mode (CM) currents on the input and output side of two widely used types of dc-to-dc power converters—buck and boost. Thus, it describes a nonlinear circuit by a linear equivalent circuit. The maximized spectrum of the CM currents is extracted for converters with stochastic signals using a novel characterization procedure. The extracted Thevenin model is used in co-simulation combined with a full-wave electromagnetic solver to predict the radiated emissions from the system consisting of the shielded dc–dc converters with attached cables and a DC brushless motor as load. The results using the terminal model agree well with the measurements providing that the actual CM loads are within the range of CM loads used while obtaining the Thevenin equivalent circuit.