Latest Publications
- Open Access
- 17 October 2023
- Published by Elsevier in Measurement
- Vol. 223
On the calibration of DC resistance ratio bridges
- 17 October 2023
- Published by Elsevier in Measurement
- Vol. 223
Open AccessOn the calibration of DC resistance ratio bridges
- 25 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-6
Comparison of Low DC Current Traceability Methods and Gas Capacitors AC–DC Dependence
This article compares two instruments for the traceable measurement of dc low currents, a custom capacitance–voltage ( $C\text{-} V$ ) source and the ultrastable low-current amplifier (ULCA), a commercial precision transresistance amplifier. The instruments are calibrated through independent traceability routes. The comparison base relative accuracy is in the $10^{-6}\!-\!10^{-5}$ range. Differences between the two instrument readings, in the $10^{-5}$ range, are interpreted as an effect of the frequency dependence of the capacitor employed in the $C\text{-} V$ source. Such frequency dependence can also affect primary metrology experiments in other fields.
- 25 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-6
Comparison of Low DC Current Traceability Methods and Gas Capacitors AC–DC Dependence
This article compares two instruments for the traceable measurement of dc low currents, a custom capacitance–voltage ( $C\text{-} V$ ) source and the ultrastable low-current amplifier (ULCA), a commercial precision transresistance amplifier. The instruments are calibrated through independent traceability routes. The comparison base relative accuracy is in the $10^{-6}\!-\!10^{-5}$ range. Differences between the two instrument readings, in the $10^{-5}$ range, are interpreted as an effect of the frequency dependence of the capacitor employed in the $C\text{-} V$ source. Such frequency dependence can also affect primary metrology experiments in other fields.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 302-305
Simulated shunts as dc low-resistance travelling standards
We introduce a device that simulates a low-valued resistance standard (shunt) that can be employed as a metrology-grade travelling standard, for the traceability transfer of dc resistance in the low range, and in laboratory intercomparisons. The device is composed of a direct-current current comparator (DCCT) and a mid-range resistance standard. A prototype having a nominal resistance of 10m Ω has been constructed. Experiments show that it can be measured with high-accuracy commercial dc resistance bridges in their default operating configurations. The power coefficient is much lower than a corresponding shunt of the same nominal resistance. The expected long-term and transport stability is a few parts in 10 6 or better.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 302-305
Simulated shunts as dc low-resistance travelling standards
We introduce a device that simulates a low-valued resistance standard (shunt) that can be employed as a metrology-grade travelling standard, for the traceability transfer of dc resistance in the low range, and in laboratory intercomparisons. The device is composed of a direct-current current comparator (DCCT) and a mid-range resistance standard. A prototype having a nominal resistance of 10m Ω has been constructed. Experiments show that it can be measured with high-accuracy commercial dc resistance bridges in their default operating configurations. The power coefficient is much lower than a corresponding shunt of the same nominal resistance. The expected long-term and transport stability is a few parts in 10 6 or better.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 286-290
The practical realisation of the ohm at INRIM
This paper describes how the Istituto Nazionale di Ricerca Metrologica (INRIM) performs the practical realisation of the ohm in order to transfer the traceability to the Italian accredited calibration laboratories in the field of dc and ac electrical resistance and of capacitance. These quantities are afterwords disseminated by the accredited laboratories to the Italian industry through the calibration of electric standards and electronic instruments. The INRIM primary measurement setup, the transfer method and more than 20 years of calibrations results are here presented.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 286-290
The practical realisation of the ohm at INRIM
This paper describes how the Istituto Nazionale di Ricerca Metrologica (INRIM) performs the practical realisation of the ohm in order to transfer the traceability to the Italian accredited calibration laboratories in the field of dc and ac electrical resistance and of capacitance. These quantities are afterwords disseminated by the accredited laboratories to the Italian industry through the calibration of electric standards and electronic instruments. The INRIM primary measurement setup, the transfer method and more than 20 years of calibrations results are here presented.
- 5 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
Controlling the Interface Properties of Submicrometric Nb/A– $\hbox{AlO}_{\rm x}$–Nb Josephson Junctions
Submicron Josephson devices are of a particular interest to the emerging field of quantum information, nanosized superconducting quantum interference devices (nano-SQUID) fabrication, AC voltage synthesis circuits for quantum metrology, etc. In this paper, we report on the development of our technology for producing non-hysteretic Nb/A-AlO x -Nb four-layered junctions with a diverse range of submicron dimensions, based on the focused ion beam (FIB) sculpting technique. We observed essential modifications of the main electrical characteristics as a result of the shrinking of the junction area, and relate them to the changes of the buried Nb/Al interface. We show that the electrical parameters-versus-temperature dependence can provide information on the quality of the junction interfaces. This aspect could be useful to better control of the entire fabrication process, allowing a further large-scale integration of Josephson nanodevices with improved transport characteristics.
- 5 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
Controlling the Interface Properties of Submicrometric Nb/A– $\hbox{AlO}_{\rm x}$–Nb Josephson Junctions
Submicron Josephson devices are of a particular interest to the emerging field of quantum information, nanosized superconducting quantum interference devices (nano-SQUID) fabrication, AC voltage synthesis circuits for quantum metrology, etc. In this paper, we report on the development of our technology for producing non-hysteretic Nb/A-AlO x -Nb four-layered junctions with a diverse range of submicron dimensions, based on the focused ion beam (FIB) sculpting technique. We observed essential modifications of the main electrical characteristics as a result of the shrinking of the junction area, and relate them to the changes of the buried Nb/Al interface. We show that the electrical parameters-versus-temperature dependence can provide information on the quality of the junction interfaces. This aspect could be useful to better control of the entire fabrication process, allowing a further large-scale integration of Josephson nanodevices with improved transport characteristics.
- 14 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 64 (3) , 723-727
On the Calibration of Direct-Current Current Transformers (DCCT)
Modern commercial dc current transformers (DCCTs) can measure currents up to the kiloampere range with accuracies better than 1 × 10 -5 . We discuss here a DCCT calibration method and its implementation with commercial instruments typically employed in low-resistance calibration laboratories. The primary current ranges up to 2 kA; in the current range <;100 A, the calibration uncertainty is better than 3 × 10 -7 . An example of calibration of a high-performance DCCT specified for primary currents measurement up to 900 A is discussed in detail.
- 14 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 64 (3) , 723-727
On the Calibration of Direct-Current Current Transformers (DCCT)
Modern commercial dc current transformers (DCCTs) can measure currents up to the kiloampere range with accuracies better than 1 × 10 -5 . We discuss here a DCCT calibration method and its implementation with commercial instruments typically employed in low-resistance calibration laboratories. The primary current ranges up to 2 kA; in the current range <;100 A, the calibration uncertainty is better than 3 × 10 -7 . An example of calibration of a high-performance DCCT specified for primary currents measurement up to 900 A is discussed in detail.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 05891485,p. 494-495
Characterization of ADC boards for application in ac electrical metrology setups
The role of analogue-to-digital converter (ADC) boards in ac primary electrical metrology is steadily increasing. Most measurement methods, and the corresponding implementations, dedicated to measurements of electrical impedance and power often do not rely on ADCs absolute accuracy, but rather on their time and temperature stability, frequency response and mismatch among channels. The summary discusses characterization method and results obtained on two high-performance commercial ADC boards.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 05891485,p. 494-495
Characterization of ADC boards for application in ac electrical metrology setups
The role of analogue-to-digital converter (ADC) boards in ac primary electrical metrology is steadily increasing. Most measurement methods, and the corresponding implementations, dedicated to measurements of electrical impedance and power often do not rely on ADCs absolute accuracy, but rather on their time and temperature stability, frequency response and mismatch among channels. The summary discusses characterization method and results obtained on two high-performance commercial ADC boards.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 646-647
Electrical waveforms from vibrational energy harvesters: A trilateral measurement comparison
The traceable measurement of the output signals of vibrational energy harvesters is needed in any determination of their electromechanical energy conversion properties. These signals have highly distorted waveforms, for which conventional meters show poor measurement performance. In the framework of the EMRP 2009 Metrology for energy harvesting project we realized three different meters, based on two strongly different measurement principles (ac-dc thermal transfer, and sampling) and performed a comparison of the methods; a summary of the experimental implementations and the results of the comparison are here reported.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 646-647
Electrical waveforms from vibrational energy harvesters: A trilateral measurement comparison
The traceable measurement of the output signals of vibrational energy harvesters is needed in any determination of their electromechanical energy conversion properties. These signals have highly distorted waveforms, for which conventional meters show poor measurement performance. In the framework of the EMRP 2009 Metrology for energy harvesting project we realized three different meters, based on two strongly different measurement principles (ac-dc thermal transfer, and sampling) and performed a comparison of the methods; a summary of the experimental implementations and the results of the comparison are here reported.
- Open Access
- 1 February 2012
- Published by IOP Publishing in New Journal of Physics
- Vol. 14 (2)
Universality of transport properties of ultrathin oxide films
- 1 February 2012
- Published by IOP Publishing in New Journal of Physics
- Vol. 14 (2)
Open AccessUniversality of transport properties of ultrathin oxide films
- 28 October 2011
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry
- Vol. 21 (46) , 18730-18737
Synthesis and properties of monolayer graphene oxyfluoride
Covalent bond-forming reactions can be used to tailor the properties of graphene, aiming at electronic band structure engineering and surface functionalization. We present a novel and easy method for the production of chemically modified monolayer graphene based on the electrochemical intercalation of graphite, that could be used for adding various functional groups to the graphene lattice. Oxy-fluorinated graphene layers have been produced and fully characterized in terms of their chemical composition and functionalization. Moreover, Raman spectroscopy allows ready discrimination between monolayers and few-layers, and field-effect devices have been fabricated in order to study the transport properties of monolayer graphene oxyfluoride. Interesting conduction mechanisms such as two dimensional Mott variable range hopping and colossal negative magneto-resistance are observed, making this novel material suitable for both fundamental research and graphene-based applications.
- 28 October 2011
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry
- Vol. 21 (46) , 18730-18737
Synthesis and properties of monolayer graphene oxyfluoride
Covalent bond-forming reactions can be used to tailor the properties of graphene, aiming at electronic band structure engineering and surface functionalization. We present a novel and easy method for the production of chemically modified monolayer graphene based on the electrochemical intercalation of graphite, that could be used for adding various functional groups to the graphene lattice. Oxy-fluorinated graphene layers have been produced and fully characterized in terms of their chemical composition and functionalization. Moreover, Raman spectroscopy allows ready discrimination between monolayers and few-layers, and field-effect devices have been fabricated in order to study the transport properties of monolayer graphene oxyfluoride. Interesting conduction mechanisms such as two dimensional Mott variable range hopping and colossal negative magneto-resistance are observed, making this novel material suitable for both fundamental research and graphene-based applications.