Zemin Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zemin Liu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Yu-Pin Hsu
Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, USA
6 shared publications - Mona Mostafa Hella
Department of Electrical, Computer and Systems Engineering, Lighting Enabled Systems and Applications (LESA) ERC, Rensselaer Polytechnic Institute, Troy, NY, USA
3 shared publications Mona Mostafa Hella
Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, USA
2 shared publications- Mona Mostafa Hella
Department of Electrical and Computer Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180
2 shared publications Bassem Fahs
ECSE Department, Rensselaer Polytechnic Institute, Troy, USA
1 shared publication- Bassem Fahs
Department of Electrical, Computer and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
1 shared publication
Latest Publications
- 31 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 55 (10) , 2756-2770
A 12.3-μW 0.72-mm² Fully Integrated Front-End IC for Arterial Pulse Waveform and ExG Recording
In this article, a power and area efficient front-end (FE) IC for biomedical instrumentation is presented. In addition to ExG recording, the proposed system provides a noninvasive arterial pulse waveform (APW) detection through direct skin contact with a packaged silicone-coated resistive-bridge pressure sensor. An automatic calibration technique is proposed to compensate for the resistive-bridge offset and reduce it down to 1 mV. High linearity in the FE is provided through the use of an instrumentation amplifier (IA) with a super class-AB output stage. The IA is followed by a single block for programmable gain amplification (PGA), low pass filtering (LPF), and analog-to-digital converter (ADC) functionality. The PGA-LPF-ADC has a reconfigurable gain from 6 to 14 dB and can cover a bandwidth from 100 to 1 kHz, saving 90% of the passives area and 25% of the FE power. Together with on-chip low dropout regulators (LDOs) and reference buffers, the prototype fabricated in 0.18-μm CMOS technology has an active area of 0.72 mm 2 and consumes a 12.3-μW dc power. The APW (ExG) FE measures an input-referred noise of 5.84 (1.22) μV rms with a total-harmonic distortion of -80 (-81.8) dB.
- 31 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 55 (10) , 2756-2770
A 12.3-μW 0.72-mm² Fully Integrated Front-End IC for Arterial Pulse Waveform and ExG Recording
In this article, a power and area efficient front-end (FE) IC for biomedical instrumentation is presented. In addition to ExG recording, the proposed system provides a noninvasive arterial pulse waveform (APW) detection through direct skin contact with a packaged silicone-coated resistive-bridge pressure sensor. An automatic calibration technique is proposed to compensate for the resistive-bridge offset and reduce it down to 1 mV. High linearity in the FE is provided through the use of an instrumentation amplifier (IA) with a super class-AB output stage. The IA is followed by a single block for programmable gain amplification (PGA), low pass filtering (LPF), and analog-to-digital converter (ADC) functionality. The PGA-LPF-ADC has a reconfigurable gain from 6 to 14 dB and can cover a bandwidth from 100 to 1 kHz, saving 90% of the passives area and 25% of the FE power. Together with on-chip low dropout regulators (LDOs) and reference buffers, the prototype fabricated in 0.18-μm CMOS technology has an active area of 0.72 mm 2 and consumes a 12.3-μW dc power. The APW (ExG) FE measures an input-referred noise of 5.84 (1.22) μV rms with a total-harmonic distortion of -80 (-81.8) dB.
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 67 (10) , 3352-3363
A Thermal/RF Hybrid Energy Harvesting System With Rectifying-Combination and Improved Fractional-OCV MPPT Method
This paper presents a thermal/RF hybrid energy harvester. The energy harvesting system can scavenge energy from a thermoelectric generator (TEG) and a radio-frequency (RF) energy source simultaneously, and deliver the combined power to a single load. Two techniques are employed in the system to increase the end-to-end efficiency; the rectifying-combination technique is proposed to eliminate the power loss associated with a dedicated AC-DC converter before the combiner and an improved fractional open-circuit voltage (FOCV) maximum power tracking (MPPT) is considered for a high average efficiency. A dynamic power path control extracts the maximum RF power from a cross-coupled differential rectifier, and also behaves as an AC/DC energy combiner. The thermal/RF harvester system achieves a measured peak end-to-end power conversion efficiency (PCE) of 63.4%. The shorter sampling time of 26ms every 16s for the proposed FOCV MPPT method reduces the long charging tail required to refresh the sampling capacitor, resulting in a an improved average efficiency of 82.2% for the thermal harvester. Fabricated in 0.18 μm CMOS technology, the prototype operates at a thermal input voltage ranging from 40 mV to 400 mV and an RF power from -18 dBm to -3 dBm and delivers an output voltage of 1.8 V. The total area of the fabricated circuit prototype is 1.22 mm².
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 67 (10) , 3352-3363
A Thermal/RF Hybrid Energy Harvesting System With Rectifying-Combination and Improved Fractional-OCV MPPT Method
This paper presents a thermal/RF hybrid energy harvester. The energy harvesting system can scavenge energy from a thermoelectric generator (TEG) and a radio-frequency (RF) energy source simultaneously, and deliver the combined power to a single load. Two techniques are employed in the system to increase the end-to-end efficiency; the rectifying-combination technique is proposed to eliminate the power loss associated with a dedicated AC-DC converter before the combiner and an improved fractional open-circuit voltage (FOCV) maximum power tracking (MPPT) is considered for a high average efficiency. A dynamic power path control extracts the maximum RF power from a cross-coupled differential rectifier, and also behaves as an AC/DC energy combiner. The thermal/RF harvester system achieves a measured peak end-to-end power conversion efficiency (PCE) of 63.4%. The shorter sampling time of 26ms every 16s for the proposed FOCV MPPT method reduces the long charging tail required to refresh the sampling capacitor, resulting in a an improved average efficiency of 82.2% for the thermal harvester. Fabricated in 0.18 μm CMOS technology, the prototype operates at a thermal input voltage ranging from 40 mV to 400 mV and an RF power from -18 dBm to -3 dBm and delivers an output voltage of 1.8 V. The total area of the fabricated circuit prototype is 1.22 mm².
- 13 March 2020
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 103 (1) , 103-116
Common-mode interference and power conversion efficiency of differential rectifiers in RF energy harvesters
- 13 March 2020
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 103 (1) , 103-116
Common-mode interference and power conversion efficiency of differential rectifiers in RF energy harvesters
- 16 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 26 (8) , 1565-1574
An RF-DC Converter IC With On-Chip Adaptive Impedance Matching and 307- $\mu$ W Peak Output Power for Health Monitoring ApplicationsThis paper presents an RF-DC converter integrated circuit (IC) with $~$307-μW output power capable of powering individual health monitoring systems. The IC is designed with an on-chip adaptive impedance matching network to accommodate a wide input RF power variation and extend the operating frequency range. The system is composed of an antenna, an adaptive impedance matching network, a three-stage full-wave RF-DC rectifier, and a low-power digital control loop. A 5-bit successive-approximation-register analog-to-digital converter (ADC) is employed to monitor the dc output voltage and tune a 4-bit binary-weighted capacitor array in the matching network through the control loop. The complete system is designed and fabricated in standard 0.13-μm CMOS technology. The post-simulated power consumption of the 5-bit ADC and digital control loop is 208 and 87 nW, respectively. Measurement results show that the impedance tuning mechanism can extend the optimal frequency range where the efficiency is higher than 80% of its peak value from 150 MHz (800-950 MHz) for the case without tuning to 220 MHz (780 MHz-1 GHz) when the impedance is adjusted using the control loop. The system achieves a measured end-to-end peak efficiency of 29.3% and is able to deliver an output power higher than 300 μW with an output voltage and current of 1.75 V and 175.4 μA, respectively. The active chip area is 0.17 mm² including the control loop and ADC.
- 16 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 26 (8) , 1565-1574
An RF-DC Converter IC With On-Chip Adaptive Impedance Matching and 307- $\mu$ W Peak Output Power for Health Monitoring ApplicationsThis paper presents an RF-DC converter integrated circuit (IC) with $~$307-μW output power capable of powering individual health monitoring systems. The IC is designed with an on-chip adaptive impedance matching network to accommodate a wide input RF power variation and extend the operating frequency range. The system is composed of an antenna, an adaptive impedance matching network, a three-stage full-wave RF-DC rectifier, and a low-power digital control loop. A 5-bit successive-approximation-register analog-to-digital converter (ADC) is employed to monitor the dc output voltage and tune a 4-bit binary-weighted capacitor array in the matching network through the control loop. The complete system is designed and fabricated in standard 0.13-μm CMOS technology. The post-simulated power consumption of the 5-bit ADC and digital control loop is 208 and 87 nW, respectively. Measurement results show that the impedance tuning mechanism can extend the optimal frequency range where the efficiency is higher than 80% of its peak value from 150 MHz (800-950 MHz) for the case without tuning to 220 MHz (780 MHz-1 GHz) when the impedance is adjusted using the control loop. The system achieves a measured end-to-end peak efficiency of 29.3% and is able to deliver an output power higher than 300 μW with an output voltage and current of 1.75 V and 175.4 μA, respectively. The active chip area is 0.17 mm² including the control loop and ADC.
- 27 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 65 (12) , 1859-1863
A 1.8 $\mu$ W −65 dB THD ECG Acquisition Front-End IC Using a Bandpass Instrumentation Amplifier With Class-AB Output ConfigurationThis brief presents a power-efficient, highly linear front-end (FE) integrated circuit (IC) for electrocardiogram (ECG) acquisition applications. Compared to typical FE architectures, the proposed FE uses only one bandpass instrumentation amplifier (IA) to reduce the chip area and dc power consumption. To achieve high linearity, the bandpass IA is composed of a high-gain two-stage amplifier in a capacitive-feedback configuration. Miller compensation and the class-AB output stage are utilized to incorporate the filtering and buffering functions within the IA without the need for additional circuit stages. The FE IC is fabricated in 0.13-μm CMOS technology, and occupies only a 0.16-mm 2 chip area. The measured input-referred noise is 3.2 μVrms with a midband gain of 34.6 dB, and a bandwidth that extends from 0.9 to 350 Hz. A total harmonic distortion of -65 dB is measured at an input signal of 5.5 mV pp , with a dc power consumption of 1.8 μW. In a real-time measurement, the proposed FE IC is capable of detecting high-fidelity ECG waveforms.
- 27 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 65 (12) , 1859-1863
A 1.8 $\mu$ W −65 dB THD ECG Acquisition Front-End IC Using a Bandpass Instrumentation Amplifier With Class-AB Output ConfigurationThis brief presents a power-efficient, highly linear front-end (FE) integrated circuit (IC) for electrocardiogram (ECG) acquisition applications. Compared to typical FE architectures, the proposed FE uses only one bandpass instrumentation amplifier (IA) to reduce the chip area and dc power consumption. To achieve high linearity, the bandpass IA is composed of a high-gain two-stage amplifier in a capacitive-feedback configuration. Miller compensation and the class-AB output stage are utilized to incorporate the filtering and buffering functions within the IA without the need for additional circuit stages. The FE IC is fabricated in 0.13-μm CMOS technology, and occupies only a 0.16-mm 2 chip area. The measured input-referred noise is 3.2 μVrms with a midband gain of 34.6 dB, and a bandwidth that extends from 0.9 to 350 Hz. A total harmonic distortion of -65 dB is measured at an input signal of 5.5 mV pp , with a dc power consumption of 1.8 μW. In a real-time measurement, the proposed FE IC is capable of detecting high-fidelity ECG waveforms.
- 11 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1538-1541
A low-power adjustable bandwidth biomedical signals acquisition SoC for continuous health monitoring system
A low-power biomedical signal acquisition SoC is proposed for continuous health monitoring system. The SoC fully integrates a low-noise analog front-end (AFE), a current-steering low-pass filter (CSLPF), and an output buffer. A DC-rejection loop and a chopping function are added to enhance the noise performance. For processing various bio-signals, the bandwidth can be adjusted to extract the signals in specific bands. The SoC, designed in a standard 0.13μm CMOS technology, passes signals from 0.3Hz to 154Hz and from 0.5Hz to 117Hz with a simulated input referred noise of 0.4μVrms and achieves maximum gains of 36dB and 42dB respectively. The power consumption is 1μW from a 1V DC supply voltage.
- 11 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1538-1541
A low-power adjustable bandwidth biomedical signals acquisition SoC for continuous health monitoring system
A low-power biomedical signal acquisition SoC is proposed for continuous health monitoring system. The SoC fully integrates a low-noise analog front-end (AFE), a current-steering low-pass filter (CSLPF), and an output buffer. A DC-rejection loop and a chopping function are added to enhance the noise performance. For processing various bio-signals, the bandwidth can be adjusted to extract the signals in specific bands. The SoC, designed in a standard 0.13μm CMOS technology, passes signals from 0.3Hz to 154Hz and from 0.5Hz to 117Hz with a simulated input referred noise of 0.4μVrms and achieves maximum gains of 36dB and 42dB respectively. The power consumption is 1μW from a 1V DC supply voltage.