MAMuhammad Asif

Muhammad Asif

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Muhammad Asif has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Thermal-Hydraulic Investigation of the Delta–Nabla Channel Arrangement in a Solar Collector

    by Muhammad Hasnain Tariq, Taqi Ahmad Cheema, Farooq Khan, M. Mohib-Ur-Rehman, Muhammad Asif, Cheol Woo Park

    A novel solar collector consisting of a delta–nabla configuration of flow channels is investigated in the present study. In the proposed design, triangular channels connected in series act as an absorber having more exposed area to the sunlight with an ability to store 21 L of water inside it that serves as a sensible energy storage to mitigate the intermittency issues. At the stage of proof of concept, the effectiveness of the novel collector design is not known. Moreover, its performance comparison with the existing solar thermal collector configurations is yet to be explored. Hence, there is a need to develop a comprehensive numerical model that can be used as a design template to predict the performance of the proposed collector configuration in a range of climatic conditions. Therefore, the present study is an attempt to investigate the thermal-hydraulic performance of the proposed collector, and transient numerical simulations are conducted. For accurate prediction, the effects of flowrate, inlet temperature, and irradiative flux on the outlet temperature are analyzed through a parametric study using the real-time data of ambient temperature and solar irradiative flux. The results of the numerical study are used to calculate the derived parameters such as Nusselt number, heat losses, and collector thermal efficiency by varying the water flowrate. The study shows that the heat transfer characteristics increase with an increase in flowrate and the collector can operate up to overall efficiencies between 29% and 62% at flowrates ranging from 0.1 to 0.8 L/min in winter. Moreover, the numerical model has predicted improved thermal performance of the proposed delta–nabla configurations when compared with a conventional solar collector design.

  • Experimental Investigation of Novel Configuration of Compressed Air Energy Storage (CAES)

    by Faisal Iqbal, Muhammad Asif, Syed Abis Hussain Rizvi, Umar Bin Salman, Muhammad Zeewaqar Cheema

    Compressed air energy storage (CAES) is a technology that harnesses the power of compressed air to store energy for future use. However, a drawback of compressed air energy storage lies in the relatively inefficient nature of the expanders used. To tackle this challenge, a novel configuration is proposed and thoroughly investigated through experimentation. The core concept of the system revolves around introducing compressed air into a water-filled cylinder, which then propels an oscillating mass back and forth. Magnets, generating a magnetic field, are strategically positioned around the cylinder. As the oscillating mass moves to and fro inside the main cylinder, it triggers specific valves at predetermined intervals, resulting in the generation of voltage. The peak voltage produced is used to calculate the power output and efficiency of the system. The calculated electrical power efficiency of the proposed configuration is determined to be 5.33%. This relatively low efficiency can primarily be attributed to the lower frequency of oscillations and the presence of resistance effects. However, the results also indicate that when considering mechanical efficiency, the concept achieves a significantly higher value of 52.14%. This finding suggests that the configuration holds greater potential for sustainable mechanical output. While this mechanism demonstrates promising capabilities as an air expander, the induction of voltage through this method proves to be inefficient for energy utilization.


  • Open Access

    Theoretical and experimental investigation of electricity generation through footstep tiles

    by Muhammad Asif, Faisal Iqbal, Hamas Esbhani, Mirza Taha Ahmed, Muhammad Uneeb Saqib

    The current study aims to utilize population expansion by introducing a specially designed footsteps tiles mechanism capable of converting kinetic energy from footsteps into electricity. A rack and pinion mechanism was implemented due to its straightforward installation process and relatively high-power generation. However, addressing user comfort was crucial, as the mechanism caused significant deflections. As a result, a footstep tile mechanism was devised, manufactured, and thoroughly examined through both experimental and simulation methods. The CAD design of the mechanism was developed in SOLIDWORKS, dynamic models were created, and the system characteristics were analyzed using the simulation tool SIMULINK MATLAB®. Based on the optimal design obtained through dynamic simulations, the mechanism was fabricated, tested, and analyzed. The testing phase demonstrated an average of 9 V generated per footstep, yielding an estimated mechanical output power of 8.5 W per footstep, with a mechanical-to-electrical conversion efficiency of 15.6 %. The proposed setup presents a promising roadmap for large-scale electricity generation in densely populated areas such as institutes, hospitals, railway stations, and similar locations.


  • An experimental investigation of porosity gradient and staggered arrangements in packed bed thermal energy storage

    by Muhammad Asif, Jawad Rabbi, Wajeeha Bibi

    Owing to the intermittent nature of solar energy, the thermal energy from the sun or waste heat can be stored in the form of latent heat in a packed bed of phase change material (PCM). In this article, PCM‐based latent heat thermal energy storage is experimentally investigated, and the effects of porosity and specific surface area (ratio of surface area to the volume of the encapsulation) on the charging and discharging times are evaluated in packed bed thermal energy storage. Locally available paraffin wax was utilized as PCM. Differential scanning calorimetry (DSC) was used to investigate the thermal properties of paraffin wax. Enthalpy of phase change, melting point, and specific heat capacity of the paraffin wax were obtained by using DSC. Experimental results revealed that there was a 17% decrease in the charging time when porosity was reduced from 0.568 to 0.485, and the corresponding surface area was 2.581 and 3.4546 m2/m3, respectively.


  • Open Access

    Reduction in Specific Energy Consumption in Desalination through Hybrid Desalination Techniques

    by Faisal Iqbal, Muhammad Asif

    Freshwater scarcity is a growing concern worldwide due to increasing demand and climate change. A promising method that could provide fresh water is seawater desalination. Presently, both thermal- and membrane-based desalination technologies consume a high amount of specific energy (measured in kWh/m3), which limits the use of seawater for drinking purposes. The development of hybrid desalination technologies has the potential to significantly reduce the energy consumption and cost of desalination, making it a more viable solution to address freshwater scarcity. By integrating the advantages of several desalination techniques and eliminating their drawbacks, hybridization can improve system performance. In the current study, a hybrid desalination system was developed by integrating the vacuum membrane distillation (VMD) output into the multi-effect distillation (MED) input. The results indicated a drop in specific thermal energy consumption (STEC) at various feed flow rates and a decrease in STEC in hybrid mode compared to stand-alone VMD.


  • Open Access

    Investigation of morphological characteristics of concentric tube thermals energy storage.

    by Icepe Conference, Jawad Rabbi, Muhammad Asif, Ali Turab Jafry, Wajeeha Bibi, Taqi Ahmad Cheema

    This study focuses on the heat transfer intensification of concentric tube type thermal energy storage (TES). The collective influence of aspect ratio (ratio of length to diameter of the tube) and number of fins is investigated. To optimize thermal energy storage, first an optimal aspect ratio investigated. And then, optimal number of fins is obtained. Results are compared based on the amount of liquid fraction available after 120 minutes of charging and discharging. It was found that with an increasing aspect ratio, liquid fraction also increased, but up to the aspect ratio of 11. Afterwards, an increased aspect ratio showed insignificant change in the liquid fraction. Similarly, liquid fraction in case of charging was increased with increasing the number of fins up to 8. Afterward, an increased number of fins showed insignificant change in the liquid fraction.

  • Open Access

    Investigation of Membrane Fouling in Vacuum Membrane Distillation (VMD) Using Blocking Filtration Laws

    by Wajeeha Bibi, Muhammad Asif, Jawad Rabbi

    VMD is one of the desalination technologies used for drinking water purification because of it higher permeate flux and lower energy consumption, and it uses low grade energy for operation. However, there are some critical problems related to VMD, one of which is membrane fouling. In the present study, the fouling phenomenon in VMD is investigated using constant pressure-blocking filtration laws. The results of constant pressure-blocking filtration law indicated that the permeate flux was initially unaffected by the cake layer, but with the passage of time as the pores began to constrict, a formation of a relatively thick cake layer was observed, which resulted in the decrease of permeate flux.

  • Open Access

    Investigation of Optimal Aspect Ratio and Optimal Number of Fins for Thermal Performance of Finned-Concentric-Tube Thermal Energy Storage

    by Jawad Rabbi, Muhammad Asif, Wajeeha Bibi

    This research focuses on the enhancement of the heat transfer in the concentric tube type of thermal energy storage (TES). The collective influence of the aspect ratio and number of fins is investigated. First, an optimal aspect ratio of the concentric tube TES is found. Additionally, then, the optimal number of fins is found. This combined optimal configuration of TES is then compared with concentric tube TES without. Liquid fraction of the combined optimal configuration was increased by 100% for case of charging as compared to TES without fins.

  • Open Access

    A numerical study on effects of axially and radially cascaded phase change material on charging/discharging time of paraffin based packed bed thermal energy storage

    by Jawad Rabbi, Muhammad Asif, Wajeeha Bibi

    This study manifests the improvement in the charging and discharging time of the encapsulated PCM arranged in packed bed thermal energy storage. The combined effect of the aspect ratio (ratio of height to diameter of the packed bed) and cascaded configurations of phase change materials (PCMs) integrated with the solar water heating system is analyzed numerically. The mathematical model is validated by the experimental study available in the literature. Initially, an optimal aspect ratio of the packed bed is predicted for charging/discharging. And then, PCMs are arranged in different layers in the packed bed based on the optimal aspect ratio to analyze the combined effect of PCM configurations and optimal aspect ratio. The charging and discharging time were decreased with an increasing aspect ratio to 2.5. Afterward, an increased aspect ratio showed a trivial change in the charging and discharging time of latent heat thermal energy storage (LHTES). Furthermore, at an optimal aspect ratio of 2.5, PCMs were arranged in the packed bed with both axial (parallel) and combined axial‐radial layers (parallel and series) to see the impact of the cascaded configuration. Charging and discharging time of combined axial‐radial layers configuration was respectively found to be 17.21% and 18.5%, less than charging time without layers.


  • Open Access

    A numerical study on effects of heat transfer fluids, copper mesh in packed bed and porosity, on charging time of paraffin based packed bed thermal energy storage

    by Jawad Rabbi, Muhammad Asif

    In this study, a novel configuration of the latent heat thermal energy storage module based on the packed bed of encapsulated phase change material is investigated. The module is modeled and simulated using a Multiphysics tool COMSOL. The simulation results are validated with the experimental data. Using the validated model, initially, water was used as heat transfer fluid, and then refrigerant R‐134 and R‐22 were also used as heat transfer fluid (HTF) to predict the impact on the charging time. The comparison in terms of their thermo‐physical properties is also carried out. The results indicated that by using refrigerants (R‐134 and R‐22) as HTF, decreased the charging time. When the water was used as HTF, it took 11 hours to completely charge the system. Whereas, the charging time for R‐134 and R‐22 was 8.75 and 8.4 hours, respectively. It was also observed that edges of packed bed were melting much slower than the remaining bed. Therefore, to increase the transfer of heat near the edges, geometry of the module is modified and their impact is investigated.