Fang Zheng Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fang Zheng Peng has a total of 121 co-authors. Here are the top co-authors by number of shared publications:
- Yuan Li
Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA
8 shared publications - Hui Li
Department of Electrical and Computer Engineering, Florida State University, Tallahassee, FL, USA
4 shared publications - Jinli Zhu
Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA
4 shared publications - Yunting Liu
Department of Electrical Engineering, The Pennsylvania State University, University Park, PA, USA
4 shared publications - Zhehui Guo
Milan M. Jovanovi Power Electronics Laboratory, Delta Electronics (Americas) Ltd., Research Triangle Park, NC, USA
4 shared publications - Brad Lehman
Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, USA
3 shared publications
Latest Publications
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-6
A Robust Control of LCL-Filtered Grid-Connected Inverters Under Weak and Unbalanced Grids
Conventional voltage-feedforward control for inductor-capacitor-inductor (LCL)-filtered grid-connected inverters suffers from reduced stability margins and harmonic distortion when grid impedance becomes significant, due to unwanted current feedforward coupling through the point of common coupling (PCC) voltage. This article presents a novel robust control strategy to ensure reliable operation under weak/unbalanced grid conditions. In this strategy, the feedforward path is relocated from the PCC to the inverter modulation signal. This effectively decouples the inverter control dynamics from grid impedance variation and enhances system robustness and reliability. Frequency-domain design and analyses are provided in this article. Comparative experimental tests were conducted under weak/unbalanced grid conditions against the PCC voltage feedforward scheme, and the results verify the effectiveness of the proposed strategy.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-6
A Robust Control of LCL-Filtered Grid-Connected Inverters Under Weak and Unbalanced Grids
Conventional voltage-feedforward control for inductor-capacitor-inductor (LCL)-filtered grid-connected inverters suffers from reduced stability margins and harmonic distortion when grid impedance becomes significant, due to unwanted current feedforward coupling through the point of common coupling (PCC) voltage. This article presents a novel robust control strategy to ensure reliable operation under weak/unbalanced grid conditions. In this strategy, the feedforward path is relocated from the PCC to the inverter modulation signal. This effectively decouples the inverter control dynamics from grid impedance variation and enhances system robustness and reliability. Frequency-domain design and analyses are provided in this article. Comparative experimental tests were conducted under weak/unbalanced grid conditions against the PCC voltage feedforward scheme, and the results verify the effectiveness of the proposed strategy.
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
A Novel Control Strategy for Grid-connected Cascaded Multilevel Inverters Improving Resilience with Flexible Neutral Shift
The asymmetric operation of a grid-connected three-phase cascaded multilevel inverter (CMI) system can significantly degrade grid current quality. Traditional solutions typically rely on hardware redundancy or complex zero-sequence injection to mitigate voltage imbalance, but these methods increase system cost or complexity. This paper proposes a flexible fault-tolerant control strategy based on adaptive shifting of the inverter’s output neutral point. After a fault, this strategy enables all phases to share the voltage deficit in the faulty phase, ensuring symmetric line-to-line voltages and balanced grid currents. A complete inner-loop current control is developed using internal modulation-based feedforward to improve steady-state tracking performance and reduce reliance on real-time PCC/grid voltage sensing. Theoretical modeling and closed-loop analysis are presented. Simulation and experimental results validate the effectiveness of the proposed strategy under fault-tolerant scenarios, demonstrating its suitability for resilient operation in CMI-based grid-connected applications.
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
A Novel Control Strategy for Grid-connected Cascaded Multilevel Inverters Improving Resilience with Flexible Neutral Shift
The asymmetric operation of a grid-connected three-phase cascaded multilevel inverter (CMI) system can significantly degrade grid current quality. Traditional solutions typically rely on hardware redundancy or complex zero-sequence injection to mitigate voltage imbalance, but these methods increase system cost or complexity. This paper proposes a flexible fault-tolerant control strategy based on adaptive shifting of the inverter’s output neutral point. After a fault, this strategy enables all phases to share the voltage deficit in the faulty phase, ensuring symmetric line-to-line voltages and balanced grid currents. A complete inner-loop current control is developed using internal modulation-based feedforward to improve steady-state tracking performance and reduce reliance on real-time PCC/grid voltage sensing. Theoretical modeling and closed-loop analysis are presented. Simulation and experimental results validate the effectiveness of the proposed strategy under fault-tolerant scenarios, demonstrating its suitability for resilient operation in CMI-based grid-connected applications.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 12118-12125
Resilient Operation for Grid-Connected Cascaded H-Bridge Multilevel Inverter Based on Neutral Offset
In power systems increasingly dominated by renewable energy generations, cascaded H-bridge (CHB) multilevel inverters are well-suited for high-power applications. However, CHB topologies are prone to unbalanced conditions due to submodule faults. While redundant submodules are commonly employed to mitigate these issues, they lower efficiency and increase the costs and complexity of circuits. This article addresses unbalanced grid currents caused by faulty submodules in CHB inverters through a neutral point-shifting control strategy. When submodules are bypassed due to faults, all remaining submodules, across both normal and faulty phases, share the lost voltage of the bypassed submodules. The corresponding control strategy is presented in this article, constraints and source voltage stress reduction are analyzed, and the effectiveness is verified by simulation and experimental tests. The proposed method can reduce system costs and downtime, thus enhancing the resilient operation of the entire system.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 12118-12125
Resilient Operation for Grid-Connected Cascaded H-Bridge Multilevel Inverter Based on Neutral Offset
In power systems increasingly dominated by renewable energy generations, cascaded H-bridge (CHB) multilevel inverters are well-suited for high-power applications. However, CHB topologies are prone to unbalanced conditions due to submodule faults. While redundant submodules are commonly employed to mitigate these issues, they lower efficiency and increase the costs and complexity of circuits. This article addresses unbalanced grid currents caused by faulty submodules in CHB inverters through a neutral point-shifting control strategy. When submodules are bypassed due to faults, all remaining submodules, across both normal and faulty phases, share the lost voltage of the bypassed submodules. The corresponding control strategy is presented in this article, constraints and source voltage stress reduction are analyzed, and the effectiveness is verified by simulation and experimental tests. The proposed method can reduce system costs and downtime, thus enhancing the resilient operation of the entire system.
- 30 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 33 (5) , 1851-1863
Robust Optimal Control of Inverter-Based Resources Under Grid-Forming Operation
In this article, we propose and solve a robust control problem (RCP) for inverter-based resources (IBRs) under grid-forming operation to regulate the voltage and frequency. One major challenge is to mitigate the effect of unmeasurable load current disturbance and grid and load parametric uncertainties. Moreover, strong coupling between the state variables on both the ac and dc sides, as well as between the modulating control input and the frequency impose additional challenges. To address these challenges, first, an RCP is solved at the high level via transformation into an equivalent, but more tractable, optimal control problem (OCP). Then, in the middle layer, a voltage control law is designed on the one side, and a frequency control law on the other side. Finally, an inverter filter current controller is designed to complete the controller design. Theoretical results are derived to provide stability guarantees for the resulting closed-loop system. Specifically, we show that the inverter current injection error is dissipative, the frequency error is semi-globally asymptotically stable, and the inverter terminal voltage error is globally asymptotically stable, all with provided sufficient conditions. Numerical simulation experiments are used to validate the theoretical claims. Furthermore, the developed controller is compared with existing work in the literature to show the efficacy of the proposed approach.
- 30 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 33 (5) , 1851-1863
Robust Optimal Control of Inverter-Based Resources Under Grid-Forming Operation
In this article, we propose and solve a robust control problem (RCP) for inverter-based resources (IBRs) under grid-forming operation to regulate the voltage and frequency. One major challenge is to mitigate the effect of unmeasurable load current disturbance and grid and load parametric uncertainties. Moreover, strong coupling between the state variables on both the ac and dc sides, as well as between the modulating control input and the frequency impose additional challenges. To address these challenges, first, an RCP is solved at the high level via transformation into an equivalent, but more tractable, optimal control problem (OCP). Then, in the middle layer, a voltage control law is designed on the one side, and a frequency control law on the other side. Finally, an inverter filter current controller is designed to complete the controller design. Theoretical results are derived to provide stability guarantees for the resulting closed-loop system. Specifically, we show that the inverter current injection error is dissipative, the frequency error is semi-globally asymptotically stable, and the inverter terminal voltage error is globally asymptotically stable, all with provided sufficient conditions. Numerical simulation experiments are used to validate the theoretical claims. Furthermore, the developed controller is compared with existing work in the literature to show the efficacy of the proposed approach.
- Open Access
- 10 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 8169
Spacetime pq theory for AC and DC electric power systems
The 50/60 Hz alternating current (AC) electric power has been the standard and most flexible energy source powering our modern societies for one and a half centuries since the war of the currents: AC versus direct current (DC). A reactive power concept that was introduced at the beginning of the AC power was very useful for circuit/system analysis, design, control, optimization, and ultimately for more efficient and stable generation, transmission, distribution, and consumption. The initial reactive power theory was based on single-phase sinusoidal AC power to capture inductive and capacitive power that yields to net-zero average power over one fundamental cycle. Soon it was expanded to non-sinusoidal AC power and finally to instantaneous three-phase AC power. However, these reactive power theories remain separate and limited to special cases and have never been consolidated and made valid to all cases. Today, more widespread adoption of power electronics and renewable energy is bringing back DC power into the electric grids. The reactive power concept has never been applied to DC power systems. There is no reactive power in DC power systems according to the existing reactive power theories. Do DC power systems really have no reactive power? Capacitors and inductors are widely used in DC just like in AC power systems. Are they not reactive power components? Why are they different from their AC counterparts? Furthermore, are batteries active or reactive power components? What about active devices like power converters (or inverters) with AC (or DC) on one side and DC (or AC) on the other? Do they generate or consume reactive power? Finally, what about AC and DC hybrid power systems? How to define reactive power in such a complex power system that has a multitude of loads, buses, and sources? Is there reactive power between any two loads, any two buses, or any two sources in a power system and what is the total reactive power in such a complex power system as a whole? As the motivation and goal of this paper to answer the above basic questions, to unify the existing AC reactive power theories and to ultimately provide theoretical and insightful guidance for system analysis, design, control, efficiency, optimization, and operation of complex power systems, a concept of spacetime (both spatial and temporal) active and reactive power (pq) theory-the spatiotemporal aspect of active and reactive power-is developed for both AC and DC power systems. The theoretical definitions and physical meanings of the spacetime reactive power will be developed, and real applications and thought experiments/cases/exercises will be explored and discussed. The developed mathematics to define the active (or real) and reactive (or imaginary) power-p and q respectively by dot (scalar) and cross (vector) products of multi-dimension spacetime vectors and time-space mapping principle/law can have some fundamental implications as well.
- 10 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 8169
Open AccessSpacetime pq theory for AC and DC electric power systems
The 50/60 Hz alternating current (AC) electric power has been the standard and most flexible energy source powering our modern societies for one and a half centuries since the war of the currents: AC versus direct current (DC). A reactive power concept that was introduced at the beginning of the AC power was very useful for circuit/system analysis, design, control, optimization, and ultimately for more efficient and stable generation, transmission, distribution, and consumption. The initial reactive power theory was based on single-phase sinusoidal AC power to capture inductive and capacitive power that yields to net-zero average power over one fundamental cycle. Soon it was expanded to non-sinusoidal AC power and finally to instantaneous three-phase AC power. However, these reactive power theories remain separate and limited to special cases and have never been consolidated and made valid to all cases. Today, more widespread adoption of power electronics and renewable energy is bringing back DC power into the electric grids. The reactive power concept has never been applied to DC power systems. There is no reactive power in DC power systems according to the existing reactive power theories. Do DC power systems really have no reactive power? Capacitors and inductors are widely used in DC just like in AC power systems. Are they not reactive power components? Why are they different from their AC counterparts? Furthermore, are batteries active or reactive power components? What about active devices like power converters (or inverters) with AC (or DC) on one side and DC (or AC) on the other? Do they generate or consume reactive power? Finally, what about AC and DC hybrid power systems? How to define reactive power in such a complex power system that has a multitude of loads, buses, and sources? Is there reactive power between any two loads, any two buses, or any two sources in a power system and what is the total reactive power in such a complex power system as a whole? As the motivation and goal of this paper to answer the above basic questions, to unify the existing AC reactive power theories and to ultimately provide theoretical and insightful guidance for system analysis, design, control, efficiency, optimization, and operation of complex power systems, a concept of spacetime (both spatial and temporal) active and reactive power (pq) theory-the spatiotemporal aspect of active and reactive power-is developed for both AC and DC power systems. The theoretical definitions and physical meanings of the spacetime reactive power will be developed, and real applications and thought experiments/cases/exercises will be explored and discussed. The developed mathematics to define the active (or real) and reactive (or imaginary) power-p and q respectively by dot (scalar) and cross (vector) products of multi-dimension spacetime vectors and time-space mapping principle/law can have some fundamental implications as well.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 1053-1068
From Active Resistor to Lossless and Virtual Resistors: A Review, Insights, and Broader Applications to Energy Grids
More-electric and pure-electric ship and aircraft, and electric-grid power systems include three subsystems: generation (generators and inverter-based renewable energy sources), delivery (transmission & distribution lines and cables, transformers, capacitor banks, inductors), and energy storage. Therefore, power systems are dominantly inductive and capacitive. Resistors are rarely used, and circuits are designed and built with minimal resistance to minimize power loss and maximize efficiency. Due to this nature, however, there have been problematic resonances, instability, and prolonged transients. To solve these problems, power converters/inverters were first presented in the 1980s as active, lossless, and virtual resistors to suppress/damp resonances, instability, and transients. In this paper, we provide a comprehensive review of this innovative power converter/inverter-based technology from the active resistor to lossless and virtual resistors. We present theoretical analysis and insights about their interrelationship and physical meanings; discuss their implementation constraints; and examine broader applications and renewed potentials to revolutionize today’s power/energy grids.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 1053-1068
From Active Resistor to Lossless and Virtual Resistors: A Review, Insights, and Broader Applications to Energy Grids
More-electric and pure-electric ship and aircraft, and electric-grid power systems include three subsystems: generation (generators and inverter-based renewable energy sources), delivery (transmission & distribution lines and cables, transformers, capacitor banks, inductors), and energy storage. Therefore, power systems are dominantly inductive and capacitive. Resistors are rarely used, and circuits are designed and built with minimal resistance to minimize power loss and maximize efficiency. Due to this nature, however, there have been problematic resonances, instability, and prolonged transients. To solve these problems, power converters/inverters were first presented in the 1980s as active, lossless, and virtual resistors to suppress/damp resonances, instability, and transients. In this paper, we provide a comprehensive review of this innovative power converter/inverter-based technology from the active resistor to lossless and virtual resistors. We present theoretical analysis and insights about their interrelationship and physical meanings; discuss their implementation constraints; and examine broader applications and renewed potentials to revolutionize today’s power/energy grids.
- Open Access
- 12 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 1404-1418
Low Frequency Versus High Frequency PWM in Medium Voltage, High Power, Higher Level Inverters: THD, Harmonic Filtering, and Efficiency Comparison
One of the main advantages of multi-level inverters (MLI) is their ability to achieve high power quality and high efficiency power conversion. With the emergence of wide-band-gap (WBG) devices, the tendency has grown towards using high switching frequencies to improve converters' output power quality and minimize switching harmonic filters footprint. While high-frequency switching finds significant success in low and medium-power applications, it is not the best practice to reduce the filter size when applied to medium voltage (MV) high power (HP) inverters implemented with high voltage levels. In this paper, we show that the least filtering requirements for MV HP higher level inverters is achieved using the modulation strategy with the least switching, i.e., the staircase modulation. The paper compares the harmonic filter requirements and power losses for low-frequency and high-frequency pulse-width-modulated MLI. The analysis shows that low-frequency switching not only achieves the lowest losses, but also produces the lowest line-to-line voltage total harmonic distortion (THD), which allows eliminating both voltage and current harmonic filters in higher level inverters. Simulation results are provided to verify the theoretical analysis on the THD, and experiments on a 1 kW, 600Vdc MLI are presented to compare efficiency for low- and high-frequency modulation.
- 12 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 1404-1418
Open AccessLow Frequency Versus High Frequency PWM in Medium Voltage, High Power, Higher Level Inverters: THD, Harmonic Filtering, and Efficiency Comparison
One of the main advantages of multi-level inverters (MLI) is their ability to achieve high power quality and high efficiency power conversion. With the emergence of wide-band-gap (WBG) devices, the tendency has grown towards using high switching frequencies to improve converters' output power quality and minimize switching harmonic filters footprint. While high-frequency switching finds significant success in low and medium-power applications, it is not the best practice to reduce the filter size when applied to medium voltage (MV) high power (HP) inverters implemented with high voltage levels. In this paper, we show that the least filtering requirements for MV HP higher level inverters is achieved using the modulation strategy with the least switching, i.e., the staircase modulation. The paper compares the harmonic filter requirements and power losses for low-frequency and high-frequency pulse-width-modulated MLI. The analysis shows that low-frequency switching not only achieves the lowest losses, but also produces the lowest line-to-line voltage total harmonic distortion (THD), which allows eliminating both voltage and current harmonic filters in higher level inverters. Simulation results are provided to verify the theoretical analysis on the THD, and experiments on a 1 kW, 600Vdc MLI are presented to compare efficiency for low- and high-frequency modulation.
- 30 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (4) , 7894-7906
Analysis, Modeling, and Experiments of a Nonlinear Inductor-Based Fault Current Commutation Strategy for a Hybrid DC Circuit Breaker
Medium voltage dc (MVdc) power system offers a potent solution for the high power density, agility, and robustness required by electric ships with escalating power needs. However, the dc power systems suffer from short-circuit fault managing issues. To solve the issue, a hybrid dc circuit breaker has been developed, featuring a novel piezoelectric actuated fast mechanical switch (FMS) and a sequential metal-oxide varistor insertion scheme. A key innovation is its nonlinear inductor-based fault current commutation strategy, designed for fast fault current extinguishment and ensuring arc-less operation of the FMS. By utilizing the saturation phenomenon properly, the inductor with variable inductance can hold current around zero to enable arc-less open of the FMS without slowing down the fault current commutation speed. The paper analyzes the features of the nonlinear inductor, presents a fractal RL circuit to model the frequency-related inductance variance and the saturation phenomenon in the time domain. Based on the model of the circuit breaker, including the nonlinear inductor, a genetic algorithm based multi-objective optimization method is developed to design the fault current commutation circuit. Experimental results with 4 kV dc voltage are presented to confirm the accuracy of the model of the nonlinear inductor and the optimized design method.
- 30 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (4) , 7894-7906
Analysis, Modeling, and Experiments of a Nonlinear Inductor-Based Fault Current Commutation Strategy for a Hybrid DC Circuit Breaker
Medium voltage dc (MVdc) power system offers a potent solution for the high power density, agility, and robustness required by electric ships with escalating power needs. However, the dc power systems suffer from short-circuit fault managing issues. To solve the issue, a hybrid dc circuit breaker has been developed, featuring a novel piezoelectric actuated fast mechanical switch (FMS) and a sequential metal-oxide varistor insertion scheme. A key innovation is its nonlinear inductor-based fault current commutation strategy, designed for fast fault current extinguishment and ensuring arc-less operation of the FMS. By utilizing the saturation phenomenon properly, the inductor with variable inductance can hold current around zero to enable arc-less open of the FMS without slowing down the fault current commutation speed. The paper analyzes the features of the nonlinear inductor, presents a fractal RL circuit to model the frequency-related inductance variance and the saturation phenomenon in the time domain. Based on the model of the circuit breaker, including the nonlinear inductor, a genetic algorithm based multi-objective optimization method is developed to design the fault current commutation circuit. Experimental results with 4 kV dc voltage are presented to confirm the accuracy of the model of the nonlinear inductor and the optimized design method.
- Open Access
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 1030-1044
Staircase Matrix Modulation for the Switched-Capacitor Modular Multilevel Converter With Sensor-Less Capacitor Voltage Balancing
Staircase modulation is a switching technique ubiquitous in multilevel inverters utilizing large number of output voltage levels. With tens of levels, the output of a multilevel inverter employing staircase modulation approaches a sinusoid without requiring switching harmonics filters. Out of various multilevel inverter topologies, the modular multilevel converter (MMC) became prominent due to its modularity, scalability, and efficiency. However, balancing the submodule (SM) capacitor voltages poses a significant challenge in MMC operation. In this work, a staircase matrix modulation (SMM) strategy, which achieves sensor-less capacitor voltage balancing, is proposed for the switched – capacitor MMC (SCMMC), an MMC topology with a very small arm inductor. The proposed SMM utilizes a full rank, symmetric switching matrix, where specific switching patterns are assigned for each voltage level. The structure of the proposed matrix, its unique features, and the process of populating its entries for any converter voltage level are described. Theoretical analysis on the operation of the proposed SMM, simulations for an 11-level SCMMC, and experimental results on a single-phase, 2kW, 425V, 4-level SCMMC prototype are presented to illustrate the voltage balancing capability of the proposed SMM. The resulting switching frequency of the SCMMC under SMM is also analyzed.
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 1030-1044
Open AccessStaircase Matrix Modulation for the Switched-Capacitor Modular Multilevel Converter With Sensor-Less Capacitor Voltage Balancing
Staircase modulation is a switching technique ubiquitous in multilevel inverters utilizing large number of output voltage levels. With tens of levels, the output of a multilevel inverter employing staircase modulation approaches a sinusoid without requiring switching harmonics filters. Out of various multilevel inverter topologies, the modular multilevel converter (MMC) became prominent due to its modularity, scalability, and efficiency. However, balancing the submodule (SM) capacitor voltages poses a significant challenge in MMC operation. In this work, a staircase matrix modulation (SMM) strategy, which achieves sensor-less capacitor voltage balancing, is proposed for the switched – capacitor MMC (SCMMC), an MMC topology with a very small arm inductor. The proposed SMM utilizes a full rank, symmetric switching matrix, where specific switching patterns are assigned for each voltage level. The structure of the proposed matrix, its unique features, and the process of populating its entries for any converter voltage level are described. Theoretical analysis on the operation of the proposed SMM, simulations for an 11-level SCMMC, and experimental results on a single-phase, 2kW, 425V, 4-level SCMMC prototype are presented to illustrate the voltage balancing capability of the proposed SMM. The resulting switching frequency of the SCMMC under SMM is also analyzed.
- Open Access
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 513-533
A Survey of Hybrid Circuit Breakers: Component-Level Insights to System-Wide Integration
This survey provides a comprehensive review of hybrid circuit breakers and their applications in 1 kV to 800 kV, both alternating current and direct current systems. The paper introduces the research motivation and key applications of hybrid circuit breakers, followed by a detailed analysis on the generic structure and operation principles of four core components: the mechanical switch, the semiconductor devices, the energy absorbers, and the commutation switch. Critical challenges on the optimization of each component are identified and potential solutions are suggested. Moreover, the paper innovatively summarizes the system-level considerations that are critical for the holistic development of hybrid circuit breakers, such as current sensing, control latency, hardware in the loop validation, and integration of multiple HCBs for multi-terminal DC system protections. This review seeks to provide design considerations and streamline the prototyping process of hybrid circuit breakers from the component, topology and system integration perspectives, which will benefit the advanced protection equipment in emerging systems such as renewable energy integration, electrified transportation, and multi-port power systems.
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 513-533
Open AccessA Survey of Hybrid Circuit Breakers: Component-Level Insights to System-Wide Integration
This survey provides a comprehensive review of hybrid circuit breakers and their applications in 1 kV to 800 kV, both alternating current and direct current systems. The paper introduces the research motivation and key applications of hybrid circuit breakers, followed by a detailed analysis on the generic structure and operation principles of four core components: the mechanical switch, the semiconductor devices, the energy absorbers, and the commutation switch. Critical challenges on the optimization of each component are identified and potential solutions are suggested. Moreover, the paper innovatively summarizes the system-level considerations that are critical for the holistic development of hybrid circuit breakers, such as current sensing, control latency, hardware in the loop validation, and integration of multiple HCBs for multi-terminal DC system protections. This review seeks to provide design considerations and streamline the prototyping process of hybrid circuit breakers from the component, topology and system integration perspectives, which will benefit the advanced protection equipment in emerging systems such as renewable energy integration, electrified transportation, and multi-port power systems.