Juan José Vaquero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Juan José Vaquero has a total of 230 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Desco
Universidad Carlos III de Madrid
40 shared publications - Jose Manuel Udias
Universidad Complutense de Madrid
10 shared publications - Joaquin Lopez Herraiz
Nuclear Physics Group and IPARCOS Complutense University of Madrid, Madrid, Spain, Madrid, Comunidad de Madrid, 28040, SPAIN
9 shared publications - María Luisa Soto-Montenegro
Instituto de Investigación Sanitaria Gregorio Marañón
9 shared publications - Javier Pascau
Departamento de Bioingeniería, Universidad Carlos III de Madrid, Leganés, Spain
6 shared publications - Monica Abella
Universidad Carlos III de Madrid
6 shared publications
Latest Publications
- Open Access
Exploring Mycobacterium tuberculosis rRNA Transcriptomic Signatures as Response to Anti-TB Treatment in Whole Blood RNA-seq Data
Current clinical tools for monitoring tuberculosis (TB) treatment response rely mostly on sputum culture and chest X-ray, which are unreliable in patients with low bacterial loads and lack the desirable promptness. There is a need for biomarkers able to provide earlier and more accurate insights into pathogen viability and response to therapy. We analyzed publicly available whole-blood RNA-seq data from 79 TB patients sampled at diagnosis, and weeks 1, 4, and 24 of standard anti-TB treatment. After aligning human reads and filtering, remaining reads were mapped to the Mycobacterium tuberculosis H37Rv genome to quantify rRNA subunit transcripts (16S, 23S, 5S, ITS1, ITS2). Microbiome profiles were assessed using Kraken2/Bracken, with alpha/beta diversity analyses and differential abundance (ANCOM-BC2). 16S and 23S rRNA transcripts were consistently detected across all treatment times, with 23S reads dominating in diagnosis and early stages of treatment shifting toward a significant predominance of 16S reads at week 24. 5S and ITS1 were inconsistently detected, whereas ITS2 was undetectable. Alpha diversity (Shannon index) increased during treatment (significant at weeks 1 and 4), while beta diversity showed significant shifts over time despite no significant differences in total M. tuberculosis abundance. Our findings suggest that it may be feasible to detect M. tuberculosis rRNA signatures in blood RNA-seq and suggest dynamic transcriptomic changes during treatment. The 16S/23S ratio and minor rRNA units may serve as complementary biomarkers for treatment monitoring and other transcriptomic-based biomarkers. Future work should validate these findings in larger cohorts using optimized RNA-seq protocols focusing on the pathogen.
Open AccessExploring Mycobacterium tuberculosis rRNA Transcriptomic Signatures as Response to Anti-TB Treatment in Whole Blood RNA-seq Data
Current clinical tools for monitoring tuberculosis (TB) treatment response rely mostly on sputum culture and chest X-ray, which are unreliable in patients with low bacterial loads and lack the desirable promptness. There is a need for biomarkers able to provide earlier and more accurate insights into pathogen viability and response to therapy. We analyzed publicly available whole-blood RNA-seq data from 79 TB patients sampled at diagnosis, and weeks 1, 4, and 24 of standard anti-TB treatment. After aligning human reads and filtering, remaining reads were mapped to the Mycobacterium tuberculosis H37Rv genome to quantify rRNA subunit transcripts (16S, 23S, 5S, ITS1, ITS2). Microbiome profiles were assessed using Kraken2/Bracken, with alpha/beta diversity analyses and differential abundance (ANCOM-BC2). 16S and 23S rRNA transcripts were consistently detected across all treatment times, with 23S reads dominating in diagnosis and early stages of treatment shifting toward a significant predominance of 16S reads at week 24. 5S and ITS1 were inconsistently detected, whereas ITS2 was undetectable. Alpha diversity (Shannon index) increased during treatment (significant at weeks 1 and 4), while beta diversity showed significant shifts over time despite no significant differences in total M. tuberculosis abundance. Our findings suggest that it may be feasible to detect M. tuberculosis rRNA signatures in blood RNA-seq and suggest dynamic transcriptomic changes during treatment. The 16S/23S ratio and minor rRNA units may serve as complementary biomarkers for treatment monitoring and other transcriptomic-based biomarkers. Future work should validate these findings in larger cohorts using optimized RNA-seq protocols focusing on the pathogen.
- Open Access
- 15 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (22) , 12329
Optimizing Point Source Tracking in Awake Rat PET Imaging: A Comprehensive Study of Motion Detection and Best Correction Conditions
Preclinical PET animal studies require immobilization of the animal, typically accomplished through the administration of anesthesia, which may affect the radiotracer biodistribution. The use of F point sources attached to the rat head is one of the most promising methods for motion compensation in awake rat PET studies. However, the presence of radioactive markers may degrade image quality. In this study, we aimed to investigate the most favorable conditions for preclinical PET studies using awake rats with attached point sources. Firstly, we investigate the optimal activity conditions for the markers and rat-injected tracer using Monte Carlo simulations to determine the parameters of maximum detectability without compromising image quality. Additionally, we scrutinize the impact of delayed window correction for random events on marker detectability and overall image quality within these studies. Secondly, we present a method designed to mitigate the influence of rapid rat movements, which resulted in a medium loss of events of around 30%, primarily observed during the initial phase of the data acquisition. We validated our study with PET acquisitions from an awake rat within the acceptable conditions of activity and motion compensation parameters. This acquisition revealed an 8% reduction in resolution compared to a sedated animal, along with a 6% decrease in signal-to-noise ratio (SNR). These outcomes affirm the viability of our method for conducting awake preclinical brain studies.- 15 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (22) , 12329
Open AccessOptimizing Point Source Tracking in Awake Rat PET Imaging: A Comprehensive Study of Motion Detection and Best Correction Conditions
Preclinical PET animal studies require immobilization of the animal, typically accomplished through the administration of anesthesia, which may affect the radiotracer biodistribution. The use of F point sources attached to the rat head is one of the most promising methods for motion compensation in awake rat PET studies. However, the presence of radioactive markers may degrade image quality. In this study, we aimed to investigate the most favorable conditions for preclinical PET studies using awake rats with attached point sources. Firstly, we investigate the optimal activity conditions for the markers and rat-injected tracer using Monte Carlo simulations to determine the parameters of maximum detectability without compromising image quality. Additionally, we scrutinize the impact of delayed window correction for random events on marker detectability and overall image quality within these studies. Secondly, we present a method designed to mitigate the influence of rapid rat movements, which resulted in a medium loss of events of around 30%, primarily observed during the initial phase of the data acquisition. We validated our study with PET acquisitions from an awake rat within the acceptable conditions of activity and motion compensation parameters. This acquisition revealed an 8% reduction in resolution compared to a sedated animal, along with a 6% decrease in signal-to-noise ratio (SNR). These outcomes affirm the viability of our method for conducting awake preclinical brain studies. - 16 October 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (6) , 065018
Reconstruction of multi-animal PET acquisitions with anisotropically variant PSF
Among other factors such as random, attenuation and scatter corrections, uniform spatial resolution is key to performing accurate quantitative studies in Positron emission tomography (PET). Particularly in preclinical PET studies involving simultaneous acquisition of multiple animals, the degradation of image resolution due to the depth of interaction (DOI) effect far from the center of the Field of View (FOV) becomes a significant concern. In this work, we incorporated a spatially-variant resolution model into a real time iterative reconstruction code to obtain accurate images of multi-animal acquisition. We estimated the spatially variant point spread function (SV-PSF) across the FOV using measurements and Monte Carlo (MC) simulations. The SV-PSF obtained was implemented in a GPU-based Ordered subset expectation maximization (OSEM) reconstruction code, which includes scatter, attenuation and random corrections. The method was evaluated with acquisitions from two preclinical PET/CT scanners of the SEDECAL Argus family: a Derenzo phantom placed 2 cm off center in the 4R-SuperArgus, and a multi-animal study with 4 mice in the 6R-SuperArgus. The SV-PSF reconstructions showed uniform spatial resolution without significant increase in reconstruction time, with superior image quality compared to the uniform PSF model.
- 16 October 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (6) , 065018
Reconstruction of multi-animal PET acquisitions with anisotropically variant PSF
Among other factors such as random, attenuation and scatter corrections, uniform spatial resolution is key to performing accurate quantitative studies in Positron emission tomography (PET). Particularly in preclinical PET studies involving simultaneous acquisition of multiple animals, the degradation of image resolution due to the depth of interaction (DOI) effect far from the center of the Field of View (FOV) becomes a significant concern. In this work, we incorporated a spatially-variant resolution model into a real time iterative reconstruction code to obtain accurate images of multi-animal acquisition. We estimated the spatially variant point spread function (SV-PSF) across the FOV using measurements and Monte Carlo (MC) simulations. The SV-PSF obtained was implemented in a GPU-based Ordered subset expectation maximization (OSEM) reconstruction code, which includes scatter, attenuation and random corrections. The method was evaluated with acquisitions from two preclinical PET/CT scanners of the SEDECAL Argus family: a Derenzo phantom placed 2 cm off center in the 4R-SuperArgus, and a multi-animal study with 4 mice in the 6R-SuperArgus. The SV-PSF reconstructions showed uniform spatial resolution without significant increase in reconstruction time, with superior image quality compared to the uniform PSF model.
- 24 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (7) , 684-691
Scintillator Geometrical Considerations for Detectors Based on Hexagonal SiPMs
A truncated icosahedron system with hexagonal detectors has been previously proposed as an approach to the ideal spherical PET scanner. In this work, we explore by Monte Carlo simulations the role of hexagonal scintillator crystals in terms of light yield, scintillation pulse decay time and energy resolution by comparison with three geometries: square and triangular prisms and cylinder. The relevance of the reflector type (diffuse and specular) and finish (polished and rough) of the scintillation borders was also considered. The light yield for the hexagon is higher by approximately 2% and 4% depending on the finish and reflector type in comparison to the square. The energy resolution is between 0.2% and 1% better for the hexagon. Polished walls with specular reflector have the finest energy resolution. The difference in the pulse decay time among geometries is not determining. The light yield and energy resolution were validated experimentally for rough walls and diffuse reflector. A hexagonal scintillation array of 181 crystals of 1.25 mm of edge was finally manufactured. The flood field image read with four multiplexing channels is presented. The detector offers an excellent crystal identification with a mean peak-to-valley ratio over 13 and an energy resolution of 11.5%.
- 24 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (7) , 684-691
Scintillator Geometrical Considerations for Detectors Based on Hexagonal SiPMs
A truncated icosahedron system with hexagonal detectors has been previously proposed as an approach to the ideal spherical PET scanner. In this work, we explore by Monte Carlo simulations the role of hexagonal scintillator crystals in terms of light yield, scintillation pulse decay time and energy resolution by comparison with three geometries: square and triangular prisms and cylinder. The relevance of the reflector type (diffuse and specular) and finish (polished and rough) of the scintillation borders was also considered. The light yield for the hexagon is higher by approximately 2% and 4% depending on the finish and reflector type in comparison to the square. The energy resolution is between 0.2% and 1% better for the hexagon. Polished walls with specular reflector have the finest energy resolution. The difference in the pulse decay time among geometries is not determining. The light yield and energy resolution were validated experimentally for rough walls and diffuse reflector. A hexagonal scintillation array of 181 crystals of 1.25 mm of edge was finally manufactured. The flood field image read with four multiplexing channels is presented. The detector offers an excellent crystal identification with a mean peak-to-valley ratio over 13 and an energy resolution of 11.5%.
- 1 April 2023
- Published by Springer Nature
- p. 117-137
The Role of Diagnostic Microdevices in the Fight Against Tuberculosis
- 1 April 2023
- Published by Springer Nature
- p. 117-137
The Role of Diagnostic Microdevices in the Fight Against Tuberculosis
- Open Access
- 30 November 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (12) , 2666
Determination of the Pharmacokinetics and Pharmacodynamics of Isoniazid, Rifampicin, Pyrazinamide and Ethambutol in a Cross-Over Cynomolgus Macaque Model of Mycobacterium tuberculosis Infection
Innovative cross-over study designs were explored in non-human primate (NHP) studies to determine the value of this approach for the evaluation of drug efficacy against tuberculosis (TB). Firstly, the pharmacokinetics (PK) of each of the drugs Isoniazid (H), Rifampicin (R), Pyrazinamide (Z) and Ethambutol (E), that are standardly used for the treatment of tuberculosis, was established in the blood of macaques after oral dosing as a monotherapy or in combination. Two studies were conducted to evaluate the pharmacokinetics and pharmacodynamics of different drug combinations using cross-over designs. The first employed a balanced, three-period Pigeon design with an extra period; this ensured that treatment by period interactions and carry-over could be detected comparing the treatments HR, HZ and HRZ using H37Rv as the challenge strain of Mycobacterium tuberculosis (M. tb). Although the design accounted for considerable variability between animals, the three regimens evaluated could not be distinguished using any of the alternative endpoints assessed. However, the degree of pathology achieved using H37Rv in the model during this study was less than expected. Based on these findings, a second experiment using a classical AB/BA design comparing HE with HRZ was conducted using the M. tb Erdman strain. More extensive pathology was observed, and differences in computerized tomography (CT) scores and bacteriology counts in the lungs were detected, although due to the small group sizes, clearer differences were not distinguished. Type 1 T helper (Th1) cell response profiles were characterized using the IFN-γ ELISPOT assay and revealed differences between drug treatments that corresponded to decreases in disease burden. Therefore, the studies performed support the utility of the NHP model for the determination of PK/PD of TB drugs, although further work is required to optimize the use of cross-over study designs.
- 30 November 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (12) , 2666
Open AccessDetermination of the Pharmacokinetics and Pharmacodynamics of Isoniazid, Rifampicin, Pyrazinamide and Ethambutol in a Cross-Over Cynomolgus Macaque Model of Mycobacterium tuberculosis Infection
Innovative cross-over study designs were explored in non-human primate (NHP) studies to determine the value of this approach for the evaluation of drug efficacy against tuberculosis (TB). Firstly, the pharmacokinetics (PK) of each of the drugs Isoniazid (H), Rifampicin (R), Pyrazinamide (Z) and Ethambutol (E), that are standardly used for the treatment of tuberculosis, was established in the blood of macaques after oral dosing as a monotherapy or in combination. Two studies were conducted to evaluate the pharmacokinetics and pharmacodynamics of different drug combinations using cross-over designs. The first employed a balanced, three-period Pigeon design with an extra period; this ensured that treatment by period interactions and carry-over could be detected comparing the treatments HR, HZ and HRZ using H37Rv as the challenge strain of Mycobacterium tuberculosis (M. tb). Although the design accounted for considerable variability between animals, the three regimens evaluated could not be distinguished using any of the alternative endpoints assessed. However, the degree of pathology achieved using H37Rv in the model during this study was less than expected. Based on these findings, a second experiment using a classical AB/BA design comparing HE with HRZ was conducted using the M. tb Erdman strain. More extensive pathology was observed, and differences in computerized tomography (CT) scores and bacteriology counts in the lungs were detected, although due to the small group sizes, clearer differences were not distinguished. Type 1 T helper (Th1) cell response profiles were characterized using the IFN-γ ELISPOT assay and revealed differences between drug treatments that corresponded to decreases in disease burden. Therefore, the studies performed support the utility of the NHP model for the determination of PK/PD of TB drugs, although further work is required to optimize the use of cross-over study designs.
- 12 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 7 (25730436) , 248-257
Super-Iterative Image Reconstruction in PET
Despite its success in many biomedical applications, Positron Emission Tomography (PET) has the drawback of typically having lower spatial resolution and higher noise respect to other medical imaging techniques. The best achievable spatial resolution in PET scanners is limited by factors such as the positron range, non-collinearity and the size of the detector crystals. In this work, we present a novel method that uses series of image reconstructions (super-iterations) to go beyond the expected resolution-noise limits for a given PET acquisition. The image quality improvement is achieved using the projections of the previous image reconstruction to redistribute the measured counts of each line-of-response (LOR) into several subLORs, from which a new activity distribution with better quality is reconstructed. The method was evaluated with data from the preclinical scanner 4R-SuperArgus PET/CT, using the NEMA NU4-2008 image quality phantom, a cold Derenzo phantom, and an in-vivo FDG cardiac study on a rat. Resolution and recovery coefficient (RC) improvement of ~10% was achieved while keeping the same noise level. Qualitative results from the in-vivo study also confirm this improvement in image quality. The proposed method is able to achieve significantly better images at the expense of a modest increase of the computational time, and it could be also applied to other modalities, such as SPECT and Compton Cameras.
- 12 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 7 (25730436) , 248-257
Super-Iterative Image Reconstruction in PET
Despite its success in many biomedical applications, Positron Emission Tomography (PET) has the drawback of typically having lower spatial resolution and higher noise respect to other medical imaging techniques. The best achievable spatial resolution in PET scanners is limited by factors such as the positron range, non-collinearity and the size of the detector crystals. In this work, we present a novel method that uses series of image reconstructions (super-iterations) to go beyond the expected resolution-noise limits for a given PET acquisition. The image quality improvement is achieved using the projections of the previous image reconstruction to redistribute the measured counts of each line-of-response (LOR) into several subLORs, from which a new activity distribution with better quality is reconstructed. The method was evaluated with data from the preclinical scanner 4R-SuperArgus PET/CT, using the NEMA NU4-2008 image quality phantom, a cold Derenzo phantom, and an in-vivo FDG cardiac study on a rat. Resolution and recovery coefficient (RC) improvement of ~10% was achieved while keeping the same noise level. Qualitative results from the in-vivo study also confirm this improvement in image quality. The proposed method is able to achieve significantly better images at the expense of a modest increase of the computational time, and it could be also applied to other modalities, such as SPECT and Compton Cameras.
- Open Access
Development of an Inverted Epifluorescence Microscope for Long-Term Monitoring of Bacteria in Multiplexed Microfluidic Devices
Developing more efficient methods for antibiotic susceptibility testing is a pressing issue in novel drug development as bacterial resistance to antibiotics becomes increasingly common. Microfluidic devices have been demonstrated to be powerful platforms that allow researchers to perform multiplexed antibiotic testing. However, the level of multiplexing within microdevices is limited, evidencing the need of creating simple, low-cost and high-resolution imaging systems that can be integrated in antibiotic development pipelines. This paper describes the design and development of an epifluorescence inverted microscope that enables long-term monitoring of bacteria inside multiplexed microfluidic devices. The goal of this work is to provide a simple microscope powerful enough to allow single-cell analysis of bacteria at a reduced cost. This facilitates increasing the number of microscopes that are simultaneously used for antibiotic testing. We prove that the designed system is able to accurately detect fluorescent beads of 100 nm, demonstrating comparable features to high-end commercial microscopes and effectively achieving the resolution required for single-cell analysis of bacteria. The proposed microscope could thus increase the efficiency in antibiotic testing while reducing cost, size, weight, and power requirements, contributing to the successful development of new antibiotic drugs.
Open AccessDevelopment of an Inverted Epifluorescence Microscope for Long-Term Monitoring of Bacteria in Multiplexed Microfluidic Devices
Developing more efficient methods for antibiotic susceptibility testing is a pressing issue in novel drug development as bacterial resistance to antibiotics becomes increasingly common. Microfluidic devices have been demonstrated to be powerful platforms that allow researchers to perform multiplexed antibiotic testing. However, the level of multiplexing within microdevices is limited, evidencing the need of creating simple, low-cost and high-resolution imaging systems that can be integrated in antibiotic development pipelines. This paper describes the design and development of an epifluorescence inverted microscope that enables long-term monitoring of bacteria inside multiplexed microfluidic devices. The goal of this work is to provide a simple microscope powerful enough to allow single-cell analysis of bacteria at a reduced cost. This facilitates increasing the number of microscopes that are simultaneously used for antibiotic testing. We prove that the designed system is able to accurately detect fluorescent beads of 100 nm, demonstrating comparable features to high-end commercial microscopes and effectively achieving the resolution required for single-cell analysis of bacteria. The proposed microscope could thus increase the efficiency in antibiotic testing while reducing cost, size, weight, and power requirements, contributing to the successful development of new antibiotic drugs.
- Open Access
- 19 April 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (8) , 2829
Real-Time 3D PET Image with Pseudoinverse Reconstruction
Real-time positron emission tomography (PET) may provide information from first-shot images, enable PET-guided biopsies, and allow awake animal studies. Fully-3D iterative reconstructions yield the best images in PET, but they are too slow for real-time imaging. Analytical methods such as Fourier back projection (FBP) are very fast, but yield images of poor quality with artifacts due to noise or data incompleteness. In this work, an image reconstruction based on the pseudoinverse of the system response matrix (SRM) is presented. w. To implement the pseudoinverse method, the reconstruction problem is separated into two stages. First, the axial part of the SRM is pseudo-inverted (PINV) to rebin the 3D data into 2D datasets. Then, the resulting 2D slices can be reconstructed with analytical methods or by applying the pseudoinverse algorithm again. The proposed two-step PINV reconstruction yielded good-quality images at a rate of several frames per second, compatible with real time applications. Furthermore, extremely fast direct PINV reconstruction of projections of the 3D image collapsed along specific directions can be implemented.
- 19 April 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (8) , 2829
Open AccessReal-Time 3D PET Image with Pseudoinverse Reconstruction
Real-time positron emission tomography (PET) may provide information from first-shot images, enable PET-guided biopsies, and allow awake animal studies. Fully-3D iterative reconstructions yield the best images in PET, but they are too slow for real-time imaging. Analytical methods such as Fourier back projection (FBP) are very fast, but yield images of poor quality with artifacts due to noise or data incompleteness. In this work, an image reconstruction based on the pseudoinverse of the system response matrix (SRM) is presented. w. To implement the pseudoinverse method, the reconstruction problem is separated into two stages. First, the axial part of the SRM is pseudo-inverted (PINV) to rebin the 3D data into 2D datasets. Then, the resulting 2D slices can be reconstructed with analytical methods or by applying the pseudoinverse algorithm again. The proposed two-step PINV reconstruction yielded good-quality images at a rate of several frames per second, compatible with real time applications. Furthermore, extremely fast direct PINV reconstruction of projections of the 3D image collapsed along specific directions can be implemented.
- Open Access
- 3 January 2020
- Published by Wiley in Computer Applications in Engineering Education
- Vol. 28 (1) , 1-4
Issue Information
- 3 January 2020
- Published by Wiley in Computer Applications in Engineering Education
- Vol. 28 (1) , 1-4
Open AccessIssue Information