Super-Iterative Image Reconstruction in PET
- 12 February 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 7 (25730436) , 248-257
Abstract
Despite its success in many biomedical applications, Positron Emission Tomography (PET) has the drawback of typically having lower spatial resolution and higher noise respect to other medical imaging techniques. The best achievable spatial resolution in PET scanners is limited by factors such as the positron range, non-collinearity and the size of the detector crystals. In this work, we present a novel method that uses series of image reconstructions (super-iterations) to go beyond the expected resolution-noise limits for a given PET acquisition. The image quality improvement is achieved using the projections of the previous image reconstruction to redistribute the measured counts of each line-of-response (LOR) into several subLORs, from which a new activity distribution with better quality is reconstructed. The method was evaluated with data from the preclinical scanner 4R-SuperArgus PET/CT, using the NEMA NU4-2008 image quality phantom, a cold Derenzo phantom, and an in-vivo FDG cardiac study on a rat. Resolution and recovery coefficient (RC) improvement of ~10% was achieved while keeping the same noise level. Qualitative results from the in-vivo study also confirm this improvement in image quality. The proposed method is able to achieve significantly better images at the expense of a modest increase of the computational time, and it could be also applied to other modalities, such as SPECT and Compton Cameras.Keywords
Funding Information
- European Commission (European Regional Development Fund, Horizon 2020 Framework Programme - 654002)
- Spanish Government (FPA2015-65035-P, RTC-2015-3772-1, RTI2018-095800-A-I00, RTI2018-098868-B-I00)
- National Institutes of Health (R01 CA215700-02)
- Ministerio de Economa y Competitividad (TEC2015-73064-EXP, TEC2016-78052-R)
- Comunidad de Madrid (B2017/BMD-3888, S2013/MIT-3024)
- Complutense University of Madrid Moncloa Campus of International Excellence and Banco Santander (CT27/16-CT28/16)
This publication has 42 references indexed in Scilit:
- Fundamental limits of spatial resolution in PETNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- Sinogram-based super-resolution in PETPhysics in Medicine & Biology, 2011
- Single scan parameterization of space-variant point spread functions in image space via a printed array: the impact for two PET/CT scannersPhysics in Medicine & Biology, 2011
- Iterative image reconstruction for positron emission tomography based on a detector response function estimated from point source measurementsPhysics in Medicine & Biology, 2009
- FIRST: Fast Iterative Reconstruction Software for (PET) tomographyPhysics in Medicine & Biology, 2006
- EM algorithm system modeling by image-space techniques for PET reconstructionIEEE Transactions on Nuclear Science, 2003
- List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular samplingIEEE Transactions on Medical Imaging, 2000
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correctionIEEE Transactions on Nuclear Science, 1991
- Constrained Fourier space method for compensation of missing data in emission computed tomographyIEEE Transactions on Medical Imaging, 1988