An investigation into potential improvements in the design of lead glasses for protecting the eyes of interventional cardiologists
- 6 July 2022
- journal article
- research article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 42 (3) , 031501
Abstract
The lens of the eye can be damaged by ionising radiation, so individuals whose eyes are exposed to radiation during their work may need to protect their eyes from exposure. Lead glasses are widely available, but there are questions about their efficiency in providing eye protection. In this study, Monte Carlo simulations are used to assess the efficiency of lead glasses in protecting the sensitive volume of the eye lens. Two designs currently available for interventional cardiologists are a wraparound (WA) style and ones with flat frontal lenses with side shielding. These designs were considered together with four modifications that would impact upon their efficiency: changing the lead equivalent thickness, adding lead to the frames, elongating the frontal lenses, and adding a closing shield to the bottom rim. For the eye closest to the source, standard models of lead glasses only decrease the radiation reaching the most sensitive region of the eye lens by 22% or less. Varying the lead thickness between 0.4 mm and 0.75 mm had little influence on the protection provided in the simulation of clinical use, neither did adding lead to the frames. Improved shielding was obtained by elongating the frontal lens, which could reduce radiation reaching the eye lens by up to 76%. Glasses with lenses that had a rim at the base, extending towards the face of the user, also provided better shielding than current models, decreasing the dose by up to 80%. In conclusion, elongating the frontal lens of lead glasses, especially of the WA design, could provide a three-fold increase in shielding efficiency and this is still valid for lenses with 0.4 mm lead equivalence.Keywords
This publication has 15 references indexed in Scilit:
- ICRP Publication 139: Occupational Radiological Protection in Interventional ProceduresAnnals of the ICRP, 2018
- Shielding Effect of Lead Glasses on Radiologists’ Eye Lens Exposure in Interventional ProceduresRadiation Protection Dosimetry, 2016
- The effectiveness of lead glasses in reducing the doses to eye lenses during cardiac implantation procedures performed using x-ray tubes above the patient tableJournal of Radiological Protection, 2016
- Derivation and application of dose reduction factors for protective eyewear worn in interventional radiology and cardiologyJournal of Radiological Protection, 2014
- Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body dosesJournal of Radiological Protection, 2014
- Efficacy of Radiation Safety Glasses in Interventional RadiologyCardioVascular and Interventional Radiology, 2013
- ICRP PUBLICATION 118: ICRP Statement on Tissue Reactions and Early and Late Effects of Radiation in Normal Tissues and Organs — Threshold Doses for Tissue Reactions in a Radiation Protection ContextAnnals of the ICRP, 2012
- Eye lens dosimetry for interventional procedures – Relation between the absorbed dose to the lens and dose at measurement positionsRadiation Measurements, 2011
- Dose conversion coefficients for photon exposure of the human eye lensPhysics in Medicine & Biology, 2010
- Dose conversion coefficients for electron exposure of the human eye lensPhysics in Medicine & Biology, 2009