Hui Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hui Li has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Zhehui Guo
Milan M. Jovanovi Power Electronics Laboratory, Delta Electronics (Americas) Ltd., Research Triangle Park, NC, USA
9 shared publications - Yanjun Shi
Center for Advanced Power Systems, Florida State University, Tallahassee, FL, USA
7 shared publications - Fang Zheng Peng
Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA
4 shared publications - Yu Zhang
Xidian University
4 shared publications - Lu Wang
Center for Advanced Power Systems, Florida State University, 7823 Tallahassee, Florida United States
3 shared publications Qing Ye
Department of Electrical and Computer Engineering, Florida State University, Tallahassee, FL, USA
3 shared publications
Latest Publications
- Open Access
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 683-721
Towards Digital Twin Driven High-Reliability Power Electronic Converters
Power electronic converters (PECs) are fundamental components in various safety-critical applications such as electrified transportation and renewable energy generation. Therefore, ensuring the reliability of PECs throughout their entire life cycle has become increasingly important. In this context, owing to the ongoing digitalization and data engineering trends, digital twin (DT) technology has become a promising tool to improve the reliability and performance of PECs through online health monitoring and intelligent decision-making. This paper presents a comprehensive and in-depth review of DT development for high-reliability PECs. A four-stage systematic framework is proposed to review the development of DT: 1) converter-level and system-level application types, 2) implementation objectives, 3) modeling methodologies, and 4) supporting mathematical algorithms. In addition, the paper explores the concept of active versus passive DT decisions based on their objectives and interaction with the physical controller of PECs. To provide more insight into health monitoring objectives, a topology-oriented classification of DT implementations is presented, which enables readers to locate and understand relevant DT solutions based on various converter types with electrical and thermal modeling. This paper aims to serve as a practical guide for researchers and engineers involved in the development or analysis of DT models for PECs.
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 683-721
Open AccessTowards Digital Twin Driven High-Reliability Power Electronic Converters
Power electronic converters (PECs) are fundamental components in various safety-critical applications such as electrified transportation and renewable energy generation. Therefore, ensuring the reliability of PECs throughout their entire life cycle has become increasingly important. In this context, owing to the ongoing digitalization and data engineering trends, digital twin (DT) technology has become a promising tool to improve the reliability and performance of PECs through online health monitoring and intelligent decision-making. This paper presents a comprehensive and in-depth review of DT development for high-reliability PECs. A four-stage systematic framework is proposed to review the development of DT: 1) converter-level and system-level application types, 2) implementation objectives, 3) modeling methodologies, and 4) supporting mathematical algorithms. In addition, the paper explores the concept of active versus passive DT decisions based on their objectives and interaction with the physical controller of PECs. To provide more insight into health monitoring objectives, a topology-oriented classification of DT implementations is presented, which enables readers to locate and understand relevant DT solutions based on various converter types with electrical and thermal modeling. This paper aims to serve as a practical guide for researchers and engineers involved in the development or analysis of DT models for PECs.
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (9) , 12031-12032
Editorial: Special Section on Highly Robust Power Electronics in the Era of DC Grid
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (9) , 12031-12032
Editorial: Special Section on Highly Robust Power Electronics in the Era of DC Grid
- Open Access
- 19 June 2025
- Published by Office of Scientific and Technical Information (OSTI)
Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant
As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.
- 19 June 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessUnified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant
As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (9) , 13965-13976
Integrated Model Predictive Control of Double-Stage Solid-State Transformers With Dynamic Reference
The dc-link voltage control is crucial for double-stage solid-state transformers. Due to differences in bandwidth and response speed between the two stages, overvoltage and undervoltage may occur in transient states, potentially leading to overmodulation in the rectifier stage and overcurrent in the dc stage. In extreme cases, the reliable operation of the entire system is threatened. Model predictive control (MPC) methods have been utilized to improve the dynamic performance of the dc-link in some previous works. However, they mainly work as the inner loop. While the inner loop is indeed enhanced, the overall dynamic remains limited by the employment of linear controllers in the outer voltage loop. To address this issue, this article proposes an integrated MPC with dynamic reference generation. Herein, the integrated cost functions for both stages account for all relevant variables. Following with it, the dynamic reference method generates real-time commands for the dc-link based on load estimation, eliminating the need for linear controllers in the outer loop. The response speed of the MPC is fully released, significantly improving the dynamic performance of the dc-link while maintaining a straightforward implementation. Finally, the experimental comparisons with other schemes verify the effectiveness and superiority of the proposed method.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (9) , 13965-13976
Integrated Model Predictive Control of Double-Stage Solid-State Transformers With Dynamic Reference
The dc-link voltage control is crucial for double-stage solid-state transformers. Due to differences in bandwidth and response speed between the two stages, overvoltage and undervoltage may occur in transient states, potentially leading to overmodulation in the rectifier stage and overcurrent in the dc stage. In extreme cases, the reliable operation of the entire system is threatened. Model predictive control (MPC) methods have been utilized to improve the dynamic performance of the dc-link in some previous works. However, they mainly work as the inner loop. While the inner loop is indeed enhanced, the overall dynamic remains limited by the employment of linear controllers in the outer voltage loop. To address this issue, this article proposes an integrated MPC with dynamic reference generation. Herein, the integrated cost functions for both stages account for all relevant variables. Following with it, the dynamic reference method generates real-time commands for the dc-link based on load estimation, eliminating the need for linear controllers in the outer loop. The response speed of the MPC is fully released, significantly improving the dynamic performance of the dc-link while maintaining a straightforward implementation. Finally, the experimental comparisons with other schemes verify the effectiveness and superiority of the proposed method.
- Open Access
- 9 May 2025
- Published by Elsevier in Applied Energy
- Vol. 393
Liquid hydrogen storage, thermal management, and transfer-control system for integrated zero emission aviation (IZEA)
- 9 May 2025
- Published by Elsevier in Applied Energy
- Vol. 393
Open AccessLiquid hydrogen storage, thermal management, and transfer-control system for integrated zero emission aviation (IZEA)
- Open Access
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (9) , 13919-13930
A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance
The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40  (9) , 13919-13930
Open AccessA Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance
The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.
- Open Access
- 12 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 1404-1418
Low Frequency Versus High Frequency PWM in Medium Voltage, High Power, Higher Level Inverters: THD, Harmonic Filtering, and Efficiency Comparison
One of the main advantages of multi-level inverters (MLI) is their ability to achieve high power quality and high efficiency power conversion. With the emergence of wide-band-gap (WBG) devices, the tendency has grown towards using high switching frequencies to improve converters' output power quality and minimize switching harmonic filters footprint. While high-frequency switching finds significant success in low and medium-power applications, it is not the best practice to reduce the filter size when applied to medium voltage (MV) high power (HP) inverters implemented with high voltage levels. In this paper, we show that the least filtering requirements for MV HP higher level inverters is achieved using the modulation strategy with the least switching, i.e., the staircase modulation. The paper compares the harmonic filter requirements and power losses for low-frequency and high-frequency pulse-width-modulated MLI. The analysis shows that low-frequency switching not only achieves the lowest losses, but also produces the lowest line-to-line voltage total harmonic distortion (THD), which allows eliminating both voltage and current harmonic filters in higher level inverters. Simulation results are provided to verify the theoretical analysis on the THD, and experiments on a 1 kW, 600Vdc MLI are presented to compare efficiency for low- and high-frequency modulation.
- 12 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 1404-1418
Open AccessLow Frequency Versus High Frequency PWM in Medium Voltage, High Power, Higher Level Inverters: THD, Harmonic Filtering, and Efficiency Comparison
One of the main advantages of multi-level inverters (MLI) is their ability to achieve high power quality and high efficiency power conversion. With the emergence of wide-band-gap (WBG) devices, the tendency has grown towards using high switching frequencies to improve converters' output power quality and minimize switching harmonic filters footprint. While high-frequency switching finds significant success in low and medium-power applications, it is not the best practice to reduce the filter size when applied to medium voltage (MV) high power (HP) inverters implemented with high voltage levels. In this paper, we show that the least filtering requirements for MV HP higher level inverters is achieved using the modulation strategy with the least switching, i.e., the staircase modulation. The paper compares the harmonic filter requirements and power losses for low-frequency and high-frequency pulse-width-modulated MLI. The analysis shows that low-frequency switching not only achieves the lowest losses, but also produces the lowest line-to-line voltage total harmonic distortion (THD), which allows eliminating both voltage and current harmonic filters in higher level inverters. Simulation results are provided to verify the theoretical analysis on the THD, and experiments on a 1 kW, 600Vdc MLI are presented to compare efficiency for low- and high-frequency modulation.
- Open Access
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 1030-1044
Staircase Matrix Modulation for the Switched-Capacitor Modular Multilevel Converter With Sensor-Less Capacitor Voltage Balancing
Staircase modulation is a switching technique ubiquitous in multilevel inverters utilizing large number of output voltage levels. With tens of levels, the output of a multilevel inverter employing staircase modulation approaches a sinusoid without requiring switching harmonics filters. Out of various multilevel inverter topologies, the modular multilevel converter (MMC) became prominent due to its modularity, scalability, and efficiency. However, balancing the submodule (SM) capacitor voltages poses a significant challenge in MMC operation. In this work, a staircase matrix modulation (SMM) strategy, which achieves sensor-less capacitor voltage balancing, is proposed for the switched – capacitor MMC (SCMMC), an MMC topology with a very small arm inductor. The proposed SMM utilizes a full rank, symmetric switching matrix, where specific switching patterns are assigned for each voltage level. The structure of the proposed matrix, its unique features, and the process of populating its entries for any converter voltage level are described. Theoretical analysis on the operation of the proposed SMM, simulations for an 11-level SCMMC, and experimental results on a single-phase, 2kW, 425V, 4-level SCMMC prototype are presented to illustrate the voltage balancing capability of the proposed SMM. The resulting switching frequency of the SCMMC under SMM is also analyzed.
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 1030-1044
Open AccessStaircase Matrix Modulation for the Switched-Capacitor Modular Multilevel Converter With Sensor-Less Capacitor Voltage Balancing
Staircase modulation is a switching technique ubiquitous in multilevel inverters utilizing large number of output voltage levels. With tens of levels, the output of a multilevel inverter employing staircase modulation approaches a sinusoid without requiring switching harmonics filters. Out of various multilevel inverter topologies, the modular multilevel converter (MMC) became prominent due to its modularity, scalability, and efficiency. However, balancing the submodule (SM) capacitor voltages poses a significant challenge in MMC operation. In this work, a staircase matrix modulation (SMM) strategy, which achieves sensor-less capacitor voltage balancing, is proposed for the switched – capacitor MMC (SCMMC), an MMC topology with a very small arm inductor. The proposed SMM utilizes a full rank, symmetric switching matrix, where specific switching patterns are assigned for each voltage level. The structure of the proposed matrix, its unique features, and the process of populating its entries for any converter voltage level are described. Theoretical analysis on the operation of the proposed SMM, simulations for an 11-level SCMMC, and experimental results on a single-phase, 2kW, 425V, 4-level SCMMC prototype are presented to illustrate the voltage balancing capability of the proposed SMM. The resulting switching frequency of the SCMMC under SMM is also analyzed.
- Open Access
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71  (9) , 10854-10863
A Fiber-Optic-Less 50-MHz Single Transformer Isolated Gate Driver With Fault Feedback for 10-kV SiC MOSFETs
This article presents a novel fiber-optic-less 50-MHz single transformer isolated gate driver (GD) for medium voltage (MV) SiC mosfet s. A unique edge-interval-OFF modulation scheme is proposed to allow signal and power simultaneously transmitted through a single transformer with minimal power switches and voltage sources. The proposed GD can also transmit the fault signal from the GD secondary side to primary side, eliminating the requirement for fiber-optic (FO) communication for fault feedback. The proposed GD offers a low propagation delay and can respond to short pulsewidths, as well as supports an ultra-wide duty-cycle range including 0% and 100% duty-cycle operation. Furthermore, it utilizes solid dielectrics to achieve a compact footprint of 61 mm Ă— 24 mm Ă— 30 mm and meet MV insulation requirements with a partial discharge (PD) inception voltage > 13.5 kV RMS under 60-Hz ac voltage and a PD-free operation under 100-kHz, 5-kV PWM voltage with a dv/dt of 100 V/ns. The proposed GD achieves an ultra-low coupling capacitance of 1.9 pF and a common-mode transient immunity (CMTI) > 100 V/ns, making it preferable to drive MV SiC mosfet s with high dv/dt . The proposed GD eliminates the need for both FOs and bulky GD power supplies, resulting in a more than 10-fold reduction in size compared to conventional 10-kV isolated GDs and has the potential to be integrated into MV SiC device packages. Experimental results on 10-kV SiC mosfet s validate the effectiveness of the proposed GD.
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71  (9) , 10854-10863
Open AccessA Fiber-Optic-Less 50-MHz Single Transformer Isolated Gate Driver With Fault Feedback for 10-kV SiC MOSFETs
This article presents a novel fiber-optic-less 50-MHz single transformer isolated gate driver (GD) for medium voltage (MV) SiC mosfet s. A unique edge-interval-OFF modulation scheme is proposed to allow signal and power simultaneously transmitted through a single transformer with minimal power switches and voltage sources. The proposed GD can also transmit the fault signal from the GD secondary side to primary side, eliminating the requirement for fiber-optic (FO) communication for fault feedback. The proposed GD offers a low propagation delay and can respond to short pulsewidths, as well as supports an ultra-wide duty-cycle range including 0% and 100% duty-cycle operation. Furthermore, it utilizes solid dielectrics to achieve a compact footprint of 61 mm Ă— 24 mm Ă— 30 mm and meet MV insulation requirements with a partial discharge (PD) inception voltage > 13.5 kV RMS under 60-Hz ac voltage and a PD-free operation under 100-kHz, 5-kV PWM voltage with a dv/dt of 100 V/ns. The proposed GD achieves an ultra-low coupling capacitance of 1.9 pF and a common-mode transient immunity (CMTI) > 100 V/ns, making it preferable to drive MV SiC mosfet s with high dv/dt . The proposed GD eliminates the need for both FOs and bulky GD power supplies, resulting in a more than 10-fold reduction in size compared to conventional 10-kV isolated GDs and has the potential to be integrated into MV SiC device packages. Experimental results on 10-kV SiC mosfet s validate the effectiveness of the proposed GD.
- Open Access
- 29 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 4, 498-511
Data-Driven Cyberphysical Anomaly Detection for Microgrids With GFM Inverters
Microgrids (MGs) have gained significant attention considering their enhanced capability to integrate increasing distributed energy resources (DERs). The application of grid forming (GFM) inverters in a MG can control voltage/frequency, enable both islanded and grid-connected operation, and achieve 100% penetration. However, cyberphysical anomaly detection for a MG with GFM inverters has not been investigated before. In this paper, the cyberphysical security of an ac MG with multiple GFM inverters is comprehensively assessed by considering short-circuit high-impedance faults (HIFs) as well as firstly exploiting False Data Injection Attacks (FDIAs) against centralized communication networks. Although the applied IEEE 1547-2018 based protection function could detect abnormal conditions, there exist cyberphysical anomalies could bypass it. In order to accomplish the detection and classification of such anomaly cases, a novel LSTM-based approach is proposed to identify the multi-class pattern regarding normal, cyberphysical threats during islanded and grid-connected by utilizing time series point of common coupling (PCC) frequency data as the paramount feature to effectively reflect the system operation status. The simulation is conducted in OPAL-RT real-time environment and the effectiveness of the proposed strategy is verified with an average detection accuracy of 94.72%.
- 29 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 4, 498-511
Open AccessData-Driven Cyberphysical Anomaly Detection for Microgrids With GFM Inverters
Microgrids (MGs) have gained significant attention considering their enhanced capability to integrate increasing distributed energy resources (DERs). The application of grid forming (GFM) inverters in a MG can control voltage/frequency, enable both islanded and grid-connected operation, and achieve 100% penetration. However, cyberphysical anomaly detection for a MG with GFM inverters has not been investigated before. In this paper, the cyberphysical security of an ac MG with multiple GFM inverters is comprehensively assessed by considering short-circuit high-impedance faults (HIFs) as well as firstly exploiting False Data Injection Attacks (FDIAs) against centralized communication networks. Although the applied IEEE 1547-2018 based protection function could detect abnormal conditions, there exist cyberphysical anomalies could bypass it. In order to accomplish the detection and classification of such anomaly cases, a novel LSTM-based approach is proposed to identify the multi-class pattern regarding normal, cyberphysical threats during islanded and grid-connected by utilizing time series point of common coupling (PCC) frequency data as the paramount feature to effectively reflect the system operation status. The simulation is conducted in OPAL-RT real-time environment and the effectiveness of the proposed strategy is verified with an average detection accuracy of 94.72%.