Delphine Bard Hagberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Delphine Bard Hagberg has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Nikolaos-Georgios Vardaxis
Division of Engineering Acoustics, Lund University, P.O. Box 118, 221 00 Lund, Sweden
7 shared publications - Sylvain Ménard
Department of Applied Sciences, University of Québec at Chicoutimi, Saguenay, QC G7H2B1, Canada
5 shared publications - Emma Arvidsson
Engineering Acoustics, Lund University, John Ericssons väg 1, 221 00 Lund, Sweden
4 shared publications - Erik Nilsson
Lund University
4 shared publications - Erling Nilsson
Saint-Gobain Ecophon AB, Yttervägen 1, 265 75 Hyllinge, Sweden
4 shared publications - Juan Negreira
Lund University
4 shared publications
Latest Publications
- Open Access
Effects of Building Height on the Sound Transmission in Cross-Laminated Timber Buildings—Vibration Reduction Index
High-rise wooden buildings are increasing in popularity, and they typically include cross-laminated timber in the structure. Taller buildings result in higher loads on the junctions lower down in the building, which are suggested in the literature to negatively affect the sound insulation. This study involved measurement of the vibration reduction index in four different CLT buildings, varying in height and junction details. A total of 12 junctions were measured at both high and low levels in the buildings. Among these, 10 junctions had resilient interlayers with different stiffnesses dependent on the designed quasi-permanent load, while 2 junctions lacked resilient interlayers. The results indicated that the vibration reduction index decreases lower down in the building mainly for the Wall–Wall path. The findings were consistent for all measured junctions above 400 Hz for the Wall–Wall path and for the majority of the measurements of the remaining frequency range, 400 Hz and below. The observed difference in the vibration reduction index could significantly impact the final result if a high-rise building has several flanking paths that affect the sound insulation between two apartments, and this needs to be considered during the design phase. Similar effects were shown for buildings both with and without resilient interlayers in the junctions.
Open AccessEffects of Building Height on the Sound Transmission in Cross-Laminated Timber Buildings—Vibration Reduction Index
High-rise wooden buildings are increasing in popularity, and they typically include cross-laminated timber in the structure. Taller buildings result in higher loads on the junctions lower down in the building, which are suggested in the literature to negatively affect the sound insulation. This study involved measurement of the vibration reduction index in four different CLT buildings, varying in height and junction details. A total of 12 junctions were measured at both high and low levels in the buildings. Among these, 10 junctions had resilient interlayers with different stiffnesses dependent on the designed quasi-permanent load, while 2 junctions lacked resilient interlayers. The results indicated that the vibration reduction index decreases lower down in the building mainly for the Wall–Wall path. The findings were consistent for all measured junctions above 400 Hz for the Wall–Wall path and for the majority of the measurements of the remaining frequency range, 400 Hz and below. The observed difference in the vibration reduction index could significantly impact the final result if a high-rise building has several flanking paths that affect the sound insulation between two apartments, and this needs to be considered during the design phase. Similar effects were shown for buildings both with and without resilient interlayers in the junctions.
- Open Access
- 28 June 2023
- Published by Elsevier in Building and Environment
- Vol. 242
Modeling field measurements of sound insulation for multi-layered CLT-based floor systems: A means of a prediction model using artificial neural networks
- 28 June 2023
- Published by Elsevier in Building and Environment
- Vol. 242
Open AccessModeling field measurements of sound insulation for multi-layered CLT-based floor systems: A means of a prediction model using artificial neural networks
- Open Access
An Iterative Ray Tracing Algorithm to Increase Simulation Speed While Maintaining Overall Precision
Ray tracing is a frequently used method for acoustic simulations, valued for its calculation speed and ease of use. Although it is fast, there are no fully ray tracing-based real-time simulation methods or engines. Under real-time restrictions, ray tracing simulations lose precision and the variance inherent in the random simulation method has too much impact on the outcome. In this paper, an algorithm called iterative ray tracing is presented that reduces the negative effects of real-time restrictions by iteratively improving the initial calculation and increasing the precision over time. In addition, new estimates of the expected value and variance of ray tracing simulations are presented and used to show the iteration steps in the new algorithm reduce variance, while maintaining the expected value. Simulations using iterative ray tracing are compared to measurements and simulations using the classical ray tracing method, and it is shown that iterative ray tracing can be used to improve precision over time. Although more testing is needed, iterative ray tracing can be used to extend most ray tracing algorithms, in order to decrease the adverse effects of real-time restrictions.
Open AccessAn Iterative Ray Tracing Algorithm to Increase Simulation Speed While Maintaining Overall Precision
Ray tracing is a frequently used method for acoustic simulations, valued for its calculation speed and ease of use. Although it is fast, there are no fully ray tracing-based real-time simulation methods or engines. Under real-time restrictions, ray tracing simulations lose precision and the variance inherent in the random simulation method has too much impact on the outcome. In this paper, an algorithm called iterative ray tracing is presented that reduces the negative effects of real-time restrictions by iteratively improving the initial calculation and increasing the precision over time. In addition, new estimates of the expected value and variance of ray tracing simulations are presented and used to show the iteration steps in the new algorithm reduce variance, while maintaining the expected value. Simulations using iterative ray tracing are compared to measurements and simulations using the classical ray tracing method, and it is shown that iterative ray tracing can be used to improve precision over time. Although more testing is needed, iterative ray tracing can be used to extend most ray tracing algorithms, in order to decrease the adverse effects of real-time restrictions.
- Open Access
- 4 January 2023
- Published by Elsevier in Building and Environment
- Vol. 229
Effects of building height on the sound transmission in cross-laminated timber buildings – Airborne sound insulation
- 4 January 2023
- Published by Elsevier in Building and Environment
- Vol. 229
Open AccessEffects of building height on the sound transmission in cross-laminated timber buildings – Airborne sound insulation
- Open Access
- 29 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (15) , 7642
Evaluating Laboratory Measurements for Sound Insulation of Cross-Laminated Timber (CLT) Floors: Configurations in Lightweight Buildings
Cross-laminated timber (CLT) floors with supplementary layers or floating floors comprise a common solution in new multistory timber structures. However, bare CLT components provide poor sound insulation, especially in low frequencies during structure-borne sound propagation. Thus, floor configurations in wooden buildings deploy more layers for improved acoustic behavior. Twelve contemporary CLT floors were analyzed after laboratory measurements of airborne sound reduction and impact sound transmission utilizing the following indicators: , , , , , and (per ISO 10140, ISO 717). An increase in sound insulation was achieved thanks to added total mass and thickness, testing layers of the following: elastic mat for vibration isolation, wool insulation, gypsum boards, plywood, concrete screed, and wooden parquet floor. The results indicate that multilayered CLT floors can provide improvements of up to 22 dB for airborne sound and 32 dB for impact sound indicators compared with the bare CLT slab. Floating floor configurations with dry floor solutions (concrete screed) and wooden parquet floors stand out as the optimal cases. The parquet floor provides a 1–2 dB improvement only for impact sound indicators in floating floor setups (or higher in three cases).- 29 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (15) , 7642
Open AccessEvaluating Laboratory Measurements for Sound Insulation of Cross-Laminated Timber (CLT) Floors: Configurations in Lightweight Buildings
Cross-laminated timber (CLT) floors with supplementary layers or floating floors comprise a common solution in new multistory timber structures. However, bare CLT components provide poor sound insulation, especially in low frequencies during structure-borne sound propagation. Thus, floor configurations in wooden buildings deploy more layers for improved acoustic behavior. Twelve contemporary CLT floors were analyzed after laboratory measurements of airborne sound reduction and impact sound transmission utilizing the following indicators: , , , , , and (per ISO 10140, ISO 717). An increase in sound insulation was achieved thanks to added total mass and thickness, testing layers of the following: elastic mat for vibration isolation, wool insulation, gypsum boards, plywood, concrete screed, and wooden parquet floor. The results indicate that multilayered CLT floors can provide improvements of up to 22 dB for airborne sound and 32 dB for impact sound indicators compared with the bare CLT slab. Floating floor configurations with dry floor solutions (concrete screed) and wooden parquet floors stand out as the optimal cases. The parquet floor provides a 1–2 dB improvement only for impact sound indicators in floating floor setups (or higher in three cases). - Open Access
- 10 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (14) , 6983
Prediction of Sound Insulation Using Artificial Neural Networks—Part II: Lightweight Wooden Façade Structures
A prediction model based on artificial neural networks is adapted to forecast the acoustic performance of airborne sound insulation of various lightweight wooden façade walls. A total of 100 insulation curves were used to develop the prediction model. The data are laboratory measurements of façade walls in one-third-octave bands (50 Hz–5 kHz). For each façade wall, geometric and physical information (material type, dimensions, thicknesses, densities, and more) are used as input parameters. The model shows a satisfactory predictive capability for airborne sound reduction. A higher accuracy is obtained at middle frequencies (250 Hz–1 kHz), while lower and higher frequency ranges often show higher deviations. The weighted airborne sound reduction index () of façades can be estimated with a maximum difference of 3 dB. Sometimes, the model shows high variations within fundamental and critical frequencies that influence the predictive precision. A sensitivity analysis is implemented to investigate the significance of parameters in insulation estimations. The material density (i.e., cross-laminated timber panel, gypsum board), thickness of the insulation materials, thickness and spacing between interior studs and the total density of façades are factors of significant weight on predictions. The results also emphasize the importance of façade thickness and the total density of the clustered exterior layers.- 10 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (14) , 6983
Open AccessPrediction of Sound Insulation Using Artificial Neural Networks—Part II: Lightweight Wooden Façade Structures
A prediction model based on artificial neural networks is adapted to forecast the acoustic performance of airborne sound insulation of various lightweight wooden façade walls. A total of 100 insulation curves were used to develop the prediction model. The data are laboratory measurements of façade walls in one-third-octave bands (50 Hz–5 kHz). For each façade wall, geometric and physical information (material type, dimensions, thicknesses, densities, and more) are used as input parameters. The model shows a satisfactory predictive capability for airborne sound reduction. A higher accuracy is obtained at middle frequencies (250 Hz–1 kHz), while lower and higher frequency ranges often show higher deviations. The weighted airborne sound reduction index () of façades can be estimated with a maximum difference of 3 dB. Sometimes, the model shows high variations within fundamental and critical frequencies that influence the predictive precision. A sensitivity analysis is implemented to investigate the significance of parameters in insulation estimations. The material density (i.e., cross-laminated timber panel, gypsum board), thickness of the insulation materials, thickness and spacing between interior studs and the total density of façades are factors of significant weight on predictions. The results also emphasize the importance of façade thickness and the total density of the clustered exterior layers. - Open Access
Acoustical Treatments on Ventilation Ducts through Walls: Experimental Results and Novel Models
Sound reduction is complex to estimate for acoustical treatments on ventilation ducts through walls. Various acoustical treatments are available for ventilation ducts, including internal lining (absorption along the inner perimeter), external lagging (external sound insulation), silencer, and suspended ceilings. Previous studies have examined how silencers and the internal lining affect the sound transmission of ventilation ducts. However, there are few theories to predict the effect of external lagging in combination with ventilation ducts and how the total sound reduction is affected. This article aims to investigate different acoustical treatments and develop theoretical models when external lagging with stone wool is used to reduce flanking sound transmission via the surface area of ventilation ducts. Theoretical models are developed for external lagging and compared with measurement data. Measurements and theory are generally in good agreement over the third-octave band range of 100–5000 Hz. The developed models clarify that the distance closest to the wall has the main impact on sound reduction for a combined system with a wall and a ventilation duct. Suspended ceilings and silencers are found to be enough as acoustical treatments for certain combinations of ventilation ducts and walls. However, external lagging seems to be the only effective solution in offices and schools when a large ventilation duct passes through a wall with high sound reduction.
Open AccessAcoustical Treatments on Ventilation Ducts through Walls: Experimental Results and Novel Models
Sound reduction is complex to estimate for acoustical treatments on ventilation ducts through walls. Various acoustical treatments are available for ventilation ducts, including internal lining (absorption along the inner perimeter), external lagging (external sound insulation), silencer, and suspended ceilings. Previous studies have examined how silencers and the internal lining affect the sound transmission of ventilation ducts. However, there are few theories to predict the effect of external lagging in combination with ventilation ducts and how the total sound reduction is affected. This article aims to investigate different acoustical treatments and develop theoretical models when external lagging with stone wool is used to reduce flanking sound transmission via the surface area of ventilation ducts. Theoretical models are developed for external lagging and compared with measurement data. Measurements and theory are generally in good agreement over the third-octave band range of 100–5000 Hz. The developed models clarify that the distance closest to the wall has the main impact on sound reduction for a combined system with a wall and a ventilation duct. Suspended ceilings and silencers are found to be enough as acoustical treatments for certain combinations of ventilation ducts and walls. However, external lagging seems to be the only effective solution in offices and schools when a large ventilation duct passes through a wall with high sound reduction.
- Open Access
Prediction of Sound Insulation Using Artificial Neural Networks—Part I: Lightweight Wooden Floor Structures
The artificial neural networks approach is applied to estimate the acoustic performance for airborne and impact sound insulation curves of different lightweight wooden floors. The prediction model is developed based on 252 standardized laboratory measurement curves in one-third octave bands (50–5000 Hz). Physical and geometric characteristics of each floor structure (materials, thickness, density, dimensions, mass and more) are utilized as network parameters. The predictive capability is satisfactory, and the model can estimate airborne sound better than impact sound cases especially in the middle-frequency range (250–1000 Hz), while higher frequency bands often show high errors. The forecast of the weighted airborne sound reduction index was calculated with a maximum error of 2 dB. However, the error increased up to 5 dB in the worse case prediction of the weighted normalized impact sound pressure level . The model showed high variations near the fundamental and critical frequency areas which affect the accuracy. A feature attribution analysis explored the essential parameters on estimation of sound insulation. The thickness of the insulation materials, the density of cross-laminated timber slab and the concrete floating floors and the total density of floor structures seem to affect predictions the most. A comparison between wet and dry floor solution systems indicated the importance of the upper part of floors to estimate airborne and impact sound in low frequencies.Open AccessPrediction of Sound Insulation Using Artificial Neural Networks—Part I: Lightweight Wooden Floor Structures
The artificial neural networks approach is applied to estimate the acoustic performance for airborne and impact sound insulation curves of different lightweight wooden floors. The prediction model is developed based on 252 standardized laboratory measurement curves in one-third octave bands (50–5000 Hz). Physical and geometric characteristics of each floor structure (materials, thickness, density, dimensions, mass and more) are utilized as network parameters. The predictive capability is satisfactory, and the model can estimate airborne sound better than impact sound cases especially in the middle-frequency range (250–1000 Hz), while higher frequency bands often show high errors. The forecast of the weighted airborne sound reduction index was calculated with a maximum error of 2 dB. However, the error increased up to 5 dB in the worse case prediction of the weighted normalized impact sound pressure level . The model showed high variations near the fundamental and critical frequency areas which affect the accuracy. A feature attribution analysis explored the essential parameters on estimation of sound insulation. The thickness of the insulation materials, the density of cross-laminated timber slab and the concrete floating floors and the total density of floor structures seem to affect predictions the most. A comparison between wet and dry floor solution systems indicated the importance of the upper part of floors to estimate airborne and impact sound in low frequencies. - Open Access
Quantification of the Absorption and Scattering Effects of Diffusers in a Room with Absorbent Ceiling
In ordinary public rooms, such as classrooms and offices, an absorbent ceiling is the typical first acoustic action. This treatment provides a good acoustic baseline. However, an improvement of specific room acoustic parameters, operating for specific frequencies, can be needed. It has been seen that diffusing elements can be effective additional treatment. In order to choose the right design, placement, and quantity of diffusers, a model to estimate the effect on the acoustics is necessary. This study evaluated whether an SEA model could be used for that purpose, particularly for the cases where diffusers are used in combination with an absorbent ceiling. It was investigated whether the model could handle different quantities of diffusing elements, varied diffusion characteristics, and varied installation patterns. It was found that the model was sensitive to these changes, given that the output from the model in terms of acoustic properties will be reflected by the change of diffuser configuration design. It was also seen that the absorption and scattering of the diffusers could be quantified in a laboratory environment: a reverberation chamber. Through the SEA model, these quantities could be transformed to a full-scale room for estimation of the room acoustic parameters.
Open AccessQuantification of the Absorption and Scattering Effects of Diffusers in a Room with Absorbent Ceiling
In ordinary public rooms, such as classrooms and offices, an absorbent ceiling is the typical first acoustic action. This treatment provides a good acoustic baseline. However, an improvement of specific room acoustic parameters, operating for specific frequencies, can be needed. It has been seen that diffusing elements can be effective additional treatment. In order to choose the right design, placement, and quantity of diffusers, a model to estimate the effect on the acoustics is necessary. This study evaluated whether an SEA model could be used for that purpose, particularly for the cases where diffusers are used in combination with an absorbent ceiling. It was investigated whether the model could handle different quantities of diffusing elements, varied diffusion characteristics, and varied installation patterns. It was found that the model was sensitive to these changes, given that the output from the model in terms of acoustic properties will be reflected by the change of diffuser configuration design. It was also seen that the absorption and scattering of the diffusers could be quantified in a laboratory environment: a reverberation chamber. Through the SEA model, these quantities could be transformed to a full-scale room for estimation of the room acoustic parameters.
- Open Access
- 23 November 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (23) , 12274
Subjective Experience of Speech Depending on the Acoustic Treatment in an Ordinary Room
In environments such as classrooms and offices, complex tasks are performed. A satisfactory acoustic environment is critical for the performance of such tasks. To ensure a good acoustic environment, the right acoustic treatment must be used. The relation between different room acoustic treatments and how they affect speech perception in these types of rooms is not yet fully understood. In this study, speech perception was evaluated for three different configurations using absorbers and diffusers. Twenty-nine participants reported on their subjective experience of speech in respect of different configurations in different positions in a room. They judged sound quality and attributes related to speech perception. In addition, the jury members ranked the different acoustic environments. The subjective experience was related to the different room acoustic treatments and the room acoustic parameters of speech clarity, reverberation time and sound strength. It was found that people, on average, rated treatments with a high degree of absorption as best. This configuration had the highest speech clarity value and lowest values for reverberation time and sound strength. The perceived sound quality could be correlated to speech clarity, while attributes related to speech perception had the strongest association with reverberation time.
- 23 November 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (23) , 12274
Open AccessSubjective Experience of Speech Depending on the Acoustic Treatment in an Ordinary Room
In environments such as classrooms and offices, complex tasks are performed. A satisfactory acoustic environment is critical for the performance of such tasks. To ensure a good acoustic environment, the right acoustic treatment must be used. The relation between different room acoustic treatments and how they affect speech perception in these types of rooms is not yet fully understood. In this study, speech perception was evaluated for three different configurations using absorbers and diffusers. Twenty-nine participants reported on their subjective experience of speech in respect of different configurations in different positions in a room. They judged sound quality and attributes related to speech perception. In addition, the jury members ranked the different acoustic environments. The subjective experience was related to the different room acoustic treatments and the room acoustic parameters of speech clarity, reverberation time and sound strength. It was found that people, on average, rated treatments with a high degree of absorption as best. This configuration had the highest speech clarity value and lowest values for reverberation time and sound strength. The perceived sound quality could be correlated to speech clarity, while attributes related to speech perception had the strongest association with reverberation time.