Nikolaos-Georgios Vardaxis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nikolaos-Georgios Vardaxis has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Delphine Bard Hagberg
Division of Engineering Acoustics, Lund University, P.O. Box 118, 221 00 Lund, Sweden
7 shared publications Delphine Bard
Division of Engineering Acoustics, Department of Construction Sciences, Faculty of Engineering LTH, Lund University, Lund, Sweden
4 shared publications- Sylvain Ménard
Department of Applied Sciences, University of Québec at Chicoutimi, Saguenay, QC G7H2B1, Canada
4 shared publications - Erik Nilsson
Lund University
2 shared publications - Hanna Autio
Division of Engineering Acoustics, Lund University, P.O. Box 118, 221 00 Lund, Sweden
2 shared publications - Jean-Luc Kouyoumji
Technological Institute FCBA, All. de Boutaut, 33000 Bordeaux, France
2 shared publications
Latest Publications
- Open Access
An Iterative Ray Tracing Algorithm to Increase Simulation Speed While Maintaining Overall Precision
Ray tracing is a frequently used method for acoustic simulations, valued for its calculation speed and ease of use. Although it is fast, there are no fully ray tracing-based real-time simulation methods or engines. Under real-time restrictions, ray tracing simulations lose precision and the variance inherent in the random simulation method has too much impact on the outcome. In this paper, an algorithm called iterative ray tracing is presented that reduces the negative effects of real-time restrictions by iteratively improving the initial calculation and increasing the precision over time. In addition, new estimates of the expected value and variance of ray tracing simulations are presented and used to show the iteration steps in the new algorithm reduce variance, while maintaining the expected value. Simulations using iterative ray tracing are compared to measurements and simulations using the classical ray tracing method, and it is shown that iterative ray tracing can be used to improve precision over time. Although more testing is needed, iterative ray tracing can be used to extend most ray tracing algorithms, in order to decrease the adverse effects of real-time restrictions.
Open AccessAn Iterative Ray Tracing Algorithm to Increase Simulation Speed While Maintaining Overall Precision
Ray tracing is a frequently used method for acoustic simulations, valued for its calculation speed and ease of use. Although it is fast, there are no fully ray tracing-based real-time simulation methods or engines. Under real-time restrictions, ray tracing simulations lose precision and the variance inherent in the random simulation method has too much impact on the outcome. In this paper, an algorithm called iterative ray tracing is presented that reduces the negative effects of real-time restrictions by iteratively improving the initial calculation and increasing the precision over time. In addition, new estimates of the expected value and variance of ray tracing simulations are presented and used to show the iteration steps in the new algorithm reduce variance, while maintaining the expected value. Simulations using iterative ray tracing are compared to measurements and simulations using the classical ray tracing method, and it is shown that iterative ray tracing can be used to improve precision over time. Although more testing is needed, iterative ray tracing can be used to extend most ray tracing algorithms, in order to decrease the adverse effects of real-time restrictions.
- Open Access
- 29 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (15) , 7642
Evaluating Laboratory Measurements for Sound Insulation of Cross-Laminated Timber (CLT) Floors: Configurations in Lightweight Buildings
Cross-laminated timber (CLT) floors with supplementary layers or floating floors comprise a common solution in new multistory timber structures. However, bare CLT components provide poor sound insulation, especially in low frequencies during structure-borne sound propagation. Thus, floor configurations in wooden buildings deploy more layers for improved acoustic behavior. Twelve contemporary CLT floors were analyzed after laboratory measurements of airborne sound reduction and impact sound transmission utilizing the following indicators: , , , , , and (per ISO 10140, ISO 717). An increase in sound insulation was achieved thanks to added total mass and thickness, testing layers of the following: elastic mat for vibration isolation, wool insulation, gypsum boards, plywood, concrete screed, and wooden parquet floor. The results indicate that multilayered CLT floors can provide improvements of up to 22 dB for airborne sound and 32 dB for impact sound indicators compared with the bare CLT slab. Floating floor configurations with dry floor solutions (concrete screed) and wooden parquet floors stand out as the optimal cases. The parquet floor provides a 1–2 dB improvement only for impact sound indicators in floating floor setups (or higher in three cases).- 29 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (15) , 7642
Open AccessEvaluating Laboratory Measurements for Sound Insulation of Cross-Laminated Timber (CLT) Floors: Configurations in Lightweight Buildings
Cross-laminated timber (CLT) floors with supplementary layers or floating floors comprise a common solution in new multistory timber structures. However, bare CLT components provide poor sound insulation, especially in low frequencies during structure-borne sound propagation. Thus, floor configurations in wooden buildings deploy more layers for improved acoustic behavior. Twelve contemporary CLT floors were analyzed after laboratory measurements of airborne sound reduction and impact sound transmission utilizing the following indicators: , , , , , and (per ISO 10140, ISO 717). An increase in sound insulation was achieved thanks to added total mass and thickness, testing layers of the following: elastic mat for vibration isolation, wool insulation, gypsum boards, plywood, concrete screed, and wooden parquet floor. The results indicate that multilayered CLT floors can provide improvements of up to 22 dB for airborne sound and 32 dB for impact sound indicators compared with the bare CLT slab. Floating floor configurations with dry floor solutions (concrete screed) and wooden parquet floors stand out as the optimal cases. The parquet floor provides a 1–2 dB improvement only for impact sound indicators in floating floor setups (or higher in three cases). - Open Access
- 10 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (14) , 6983
Prediction of Sound Insulation Using Artificial Neural Networks—Part II: Lightweight Wooden Façade Structures
A prediction model based on artificial neural networks is adapted to forecast the acoustic performance of airborne sound insulation of various lightweight wooden façade walls. A total of 100 insulation curves were used to develop the prediction model. The data are laboratory measurements of façade walls in one-third-octave bands (50 Hz–5 kHz). For each façade wall, geometric and physical information (material type, dimensions, thicknesses, densities, and more) are used as input parameters. The model shows a satisfactory predictive capability for airborne sound reduction. A higher accuracy is obtained at middle frequencies (250 Hz–1 kHz), while lower and higher frequency ranges often show higher deviations. The weighted airborne sound reduction index () of façades can be estimated with a maximum difference of 3 dB. Sometimes, the model shows high variations within fundamental and critical frequencies that influence the predictive precision. A sensitivity analysis is implemented to investigate the significance of parameters in insulation estimations. The material density (i.e., cross-laminated timber panel, gypsum board), thickness of the insulation materials, thickness and spacing between interior studs and the total density of façades are factors of significant weight on predictions. The results also emphasize the importance of façade thickness and the total density of the clustered exterior layers.- 10 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (14) , 6983
Open AccessPrediction of Sound Insulation Using Artificial Neural Networks—Part II: Lightweight Wooden Façade Structures
A prediction model based on artificial neural networks is adapted to forecast the acoustic performance of airborne sound insulation of various lightweight wooden façade walls. A total of 100 insulation curves were used to develop the prediction model. The data are laboratory measurements of façade walls in one-third-octave bands (50 Hz–5 kHz). For each façade wall, geometric and physical information (material type, dimensions, thicknesses, densities, and more) are used as input parameters. The model shows a satisfactory predictive capability for airborne sound reduction. A higher accuracy is obtained at middle frequencies (250 Hz–1 kHz), while lower and higher frequency ranges often show higher deviations. The weighted airborne sound reduction index () of façades can be estimated with a maximum difference of 3 dB. Sometimes, the model shows high variations within fundamental and critical frequencies that influence the predictive precision. A sensitivity analysis is implemented to investigate the significance of parameters in insulation estimations. The material density (i.e., cross-laminated timber panel, gypsum board), thickness of the insulation materials, thickness and spacing between interior studs and the total density of façades are factors of significant weight on predictions. The results also emphasize the importance of façade thickness and the total density of the clustered exterior layers. - Open Access
Acoustical Treatments on Ventilation Ducts through Walls: Experimental Results and Novel Models
Sound reduction is complex to estimate for acoustical treatments on ventilation ducts through walls. Various acoustical treatments are available for ventilation ducts, including internal lining (absorption along the inner perimeter), external lagging (external sound insulation), silencer, and suspended ceilings. Previous studies have examined how silencers and the internal lining affect the sound transmission of ventilation ducts. However, there are few theories to predict the effect of external lagging in combination with ventilation ducts and how the total sound reduction is affected. This article aims to investigate different acoustical treatments and develop theoretical models when external lagging with stone wool is used to reduce flanking sound transmission via the surface area of ventilation ducts. Theoretical models are developed for external lagging and compared with measurement data. Measurements and theory are generally in good agreement over the third-octave band range of 100–5000 Hz. The developed models clarify that the distance closest to the wall has the main impact on sound reduction for a combined system with a wall and a ventilation duct. Suspended ceilings and silencers are found to be enough as acoustical treatments for certain combinations of ventilation ducts and walls. However, external lagging seems to be the only effective solution in offices and schools when a large ventilation duct passes through a wall with high sound reduction.
Open AccessAcoustical Treatments on Ventilation Ducts through Walls: Experimental Results and Novel Models
Sound reduction is complex to estimate for acoustical treatments on ventilation ducts through walls. Various acoustical treatments are available for ventilation ducts, including internal lining (absorption along the inner perimeter), external lagging (external sound insulation), silencer, and suspended ceilings. Previous studies have examined how silencers and the internal lining affect the sound transmission of ventilation ducts. However, there are few theories to predict the effect of external lagging in combination with ventilation ducts and how the total sound reduction is affected. This article aims to investigate different acoustical treatments and develop theoretical models when external lagging with stone wool is used to reduce flanking sound transmission via the surface area of ventilation ducts. Theoretical models are developed for external lagging and compared with measurement data. Measurements and theory are generally in good agreement over the third-octave band range of 100–5000 Hz. The developed models clarify that the distance closest to the wall has the main impact on sound reduction for a combined system with a wall and a ventilation duct. Suspended ceilings and silencers are found to be enough as acoustical treatments for certain combinations of ventilation ducts and walls. However, external lagging seems to be the only effective solution in offices and schools when a large ventilation duct passes through a wall with high sound reduction.
- Open Access
Prediction of Sound Insulation Using Artificial Neural Networks—Part I: Lightweight Wooden Floor Structures
The artificial neural networks approach is applied to estimate the acoustic performance for airborne and impact sound insulation curves of different lightweight wooden floors. The prediction model is developed based on 252 standardized laboratory measurement curves in one-third octave bands (50–5000 Hz). Physical and geometric characteristics of each floor structure (materials, thickness, density, dimensions, mass and more) are utilized as network parameters. The predictive capability is satisfactory, and the model can estimate airborne sound better than impact sound cases especially in the middle-frequency range (250–1000 Hz), while higher frequency bands often show high errors. The forecast of the weighted airborne sound reduction index was calculated with a maximum error of 2 dB. However, the error increased up to 5 dB in the worse case prediction of the weighted normalized impact sound pressure level . The model showed high variations near the fundamental and critical frequency areas which affect the accuracy. A feature attribution analysis explored the essential parameters on estimation of sound insulation. The thickness of the insulation materials, the density of cross-laminated timber slab and the concrete floating floors and the total density of floor structures seem to affect predictions the most. A comparison between wet and dry floor solution systems indicated the importance of the upper part of floors to estimate airborne and impact sound in low frequencies.Open AccessPrediction of Sound Insulation Using Artificial Neural Networks—Part I: Lightweight Wooden Floor Structures
The artificial neural networks approach is applied to estimate the acoustic performance for airborne and impact sound insulation curves of different lightweight wooden floors. The prediction model is developed based on 252 standardized laboratory measurement curves in one-third octave bands (50–5000 Hz). Physical and geometric characteristics of each floor structure (materials, thickness, density, dimensions, mass and more) are utilized as network parameters. The predictive capability is satisfactory, and the model can estimate airborne sound better than impact sound cases especially in the middle-frequency range (250–1000 Hz), while higher frequency bands often show high errors. The forecast of the weighted airborne sound reduction index was calculated with a maximum error of 2 dB. However, the error increased up to 5 dB in the worse case prediction of the weighted normalized impact sound pressure level . The model showed high variations near the fundamental and critical frequency areas which affect the accuracy. A feature attribution analysis explored the essential parameters on estimation of sound insulation. The thickness of the insulation materials, the density of cross-laminated timber slab and the concrete floating floors and the total density of floor structures seem to affect predictions the most. A comparison between wet and dry floor solution systems indicated the importance of the upper part of floors to estimate airborne and impact sound in low frequencies. - Open Access
Sound Reduction of Ventilation Ducts through Walls: Experimental Results and Updated Models
Ventilation ducts can have a negative effect on the sound reduction index between two rooms if they pass through the dividing structure without treatments. The overall sound reduction of a ventilation duct is dependent on several factors including the transmission loss when sound is breaking in and out from the duct. This study aims to model the sound reduction of a combined system with a separating wall and a ventilation duct through it. Three walls, characterized according to ISO 717-1, are combined with three different ventilation ducts, two circular and one rectangular with different dimensions. Laboratory measurement data are used to determine the sound reduction of the different configurations and the type of treatments needed for each configuration. A proposed model with existing theory for describing sound transmission losses of circular and rectangular ventilation ducts predicts the shape of the measurement data for many frequency bands. A new theory part is developed through an iterative process for circular ducts, which is based on measurements with previous methods and studies as a guide because the existing prediction scheme is somewhat perplexing. For rectangular ducts, the existing theory has been updated to better match measurement data. The application of the proposed theory and model in this article shows similar results when compared to measurements. The difference in weighted sound reduction index between developed theories and measurement data is 0–1 dB for every configuration.
Open AccessSound Reduction of Ventilation Ducts through Walls: Experimental Results and Updated Models
Ventilation ducts can have a negative effect on the sound reduction index between two rooms if they pass through the dividing structure without treatments. The overall sound reduction of a ventilation duct is dependent on several factors including the transmission loss when sound is breaking in and out from the duct. This study aims to model the sound reduction of a combined system with a separating wall and a ventilation duct through it. Three walls, characterized according to ISO 717-1, are combined with three different ventilation ducts, two circular and one rectangular with different dimensions. Laboratory measurement data are used to determine the sound reduction of the different configurations and the type of treatments needed for each configuration. A proposed model with existing theory for describing sound transmission losses of circular and rectangular ventilation ducts predicts the shape of the measurement data for many frequency bands. A new theory part is developed through an iterative process for circular ducts, which is based on measurements with previous methods and studies as a guide because the existing prediction scheme is somewhat perplexing. For rectangular ducts, the existing theory has been updated to better match measurement data. The application of the proposed theory and model in this article shows similar results when compared to measurements. The difference in weighted sound reduction index between developed theories and measurement data is 0–1 dB for every configuration.
- Open Access
The Influence of Different Scattering Algorithms on Room Acoustic Simulations in Rectangular Rooms
Raytracing is a widespread tool for room acoustic simulations, and one of its main advantages is the inclusion of surface scattering. Although surface scattering has been acknowledged as a central aspect of accurate raytracing simulations for many years, there is ongoing research into its effects and how to implement it better. This study evaluates three different algorithms for surface scattering in raytracers, referred to as on–off scattering, perturbation scattering, and diffuse field scattering. Their theoretical foundation is discussed, and the physical accuracy of the resulting simulations is evaluated by comparing simulated room acoustic parameters to measurements. It is found that the choice of surface scattering algorithm has a significant impact on the simulation outcomes, both in terms of physical accuracy and in terms of usability. Additionally, there are differences in the parametrization of surface scattering depending on the algorithm chosen. Of the three tested algorithms, the most commonly used algorithm (on–off scattering) seems to have the best properties for simulations.
Open AccessThe Influence of Different Scattering Algorithms on Room Acoustic Simulations in Rectangular Rooms
Raytracing is a widespread tool for room acoustic simulations, and one of its main advantages is the inclusion of surface scattering. Although surface scattering has been acknowledged as a central aspect of accurate raytracing simulations for many years, there is ongoing research into its effects and how to implement it better. This study evaluates three different algorithms for surface scattering in raytracers, referred to as on–off scattering, perturbation scattering, and diffuse field scattering. Their theoretical foundation is discussed, and the physical accuracy of the resulting simulations is evaluated by comparing simulated room acoustic parameters to measurements. It is found that the choice of surface scattering algorithm has a significant impact on the simulation outcomes, both in terms of physical accuracy and in terms of usability. Additionally, there are differences in the parametrization of surface scattering depending on the algorithm chosen. Of the three tested algorithms, the most commonly used algorithm (on–off scattering) seems to have the best properties for simulations.
- Open Access
- 21 August 2018
- Published by SAGE Publications in Building Acoustics
- Vol. 25 (4) , 289-305
Review of acoustic comfort evaluation in dwellings: Part III—airborne sound data associated with subjective responses in laboratory tests
Acoustic comfort has been used in engineering to refer to conditions of low noise levels or annoyance, while current standardized methods for airborne and impact sound reduction are used to assess acoustic comfort in dwellings. However, the results and descriptors acquired from acoustic measurements do not represent the human perception of sound or comfort levels. This article is a review of laboratory studies concerning airborne sound in dwellings. Specifically, this review presents studies that approach acoustic comfort via the association of objective and subjective data in laboratory listening tests, combining airborne sound acoustic data, and subjective ratings. The presented studies are tabulated and evaluated using Bradford Hill’s criteria. Many of them attempt to predict subjective noise annoyance and find the best single number quantity for that reason. The results indicate that subjective response to airborne sound is complicated and varies according to different sound stimuli. It can be associated sufficiently with airborne sound in general but different descriptors relate best to music sounds or speech stimuli. The inclusion of low frequencies down to 50 Hz in the measurements seems to weaken the association of self-reported responses to airborne sound types except for the cases of music stimuli.
- 21 August 2018
- Published by SAGE Publications in Building Acoustics
- Vol. 25 (4) , 289-305
Open AccessReview of acoustic comfort evaluation in dwellings: Part III—airborne sound data associated with subjective responses in laboratory tests
Acoustic comfort has been used in engineering to refer to conditions of low noise levels or annoyance, while current standardized methods for airborne and impact sound reduction are used to assess acoustic comfort in dwellings. However, the results and descriptors acquired from acoustic measurements do not represent the human perception of sound or comfort levels. This article is a review of laboratory studies concerning airborne sound in dwellings. Specifically, this review presents studies that approach acoustic comfort via the association of objective and subjective data in laboratory listening tests, combining airborne sound acoustic data, and subjective ratings. The presented studies are tabulated and evaluated using Bradford Hill’s criteria. Many of them attempt to predict subjective noise annoyance and find the best single number quantity for that reason. The results indicate that subjective response to airborne sound is complicated and varies according to different sound stimuli. It can be associated sufficiently with airborne sound in general but different descriptors relate best to music sounds or speech stimuli. The inclusion of low frequencies down to 50 Hz in the measurements seems to weaken the association of self-reported responses to airborne sound types except for the cases of music stimuli.
- Open Access
- 14 May 2018
- Published by SAGE Publications in Building Acoustics
- Vol. 25 (2) , 171-192
Review of acoustic comfort evaluation in dwellings: part II—impact sound data associated with subjective responses in laboratory tests
The concept of acoustic comfort is hardly defined and used to refer to conditions of low noise levels or annoyance based on standardized descriptors. Airborne and impact sound measurements are used to rate acoustic comfort in dwellings, but they often do not express human perception of noise or comfort. If the descriptors are statistically associated with self-reported responses, they can be used as prediction models and considered sufficient for acoustic comfort assessment. This review article presents studies that approach acoustic comfort in dwellings via the association of acoustic data and subjective responses in laboratory tests. Specifically, we investigate the cases of impact sound, since it is usually reported as the most disturbing noise source in dwellings. We also evaluated the reviewed studies with the Bradford Hill’s criteria. The reviewed studies indicate that self-reported annoyance to impact sound is an important issue and it can be predicted well in overall. Various standardized descriptors are studied and associate sufficiently with subjective responses. Inclusion of low frequencies down to 50 Hz in measurements improves the association of impact sound descriptors to subjective responses. Some impact noise stimuli associate only with some descriptors but not all. From the standardized impact sources, the tapping machine is the most efficient to predict overall annoyance and the impact ball for human walking or typical impact sounds in dwellings.
- 14 May 2018
- Published by SAGE Publications in Building Acoustics
- Vol. 25 (2) , 171-192
Open AccessReview of acoustic comfort evaluation in dwellings: part II—impact sound data associated with subjective responses in laboratory tests
The concept of acoustic comfort is hardly defined and used to refer to conditions of low noise levels or annoyance based on standardized descriptors. Airborne and impact sound measurements are used to rate acoustic comfort in dwellings, but they often do not express human perception of noise or comfort. If the descriptors are statistically associated with self-reported responses, they can be used as prediction models and considered sufficient for acoustic comfort assessment. This review article presents studies that approach acoustic comfort in dwellings via the association of acoustic data and subjective responses in laboratory tests. Specifically, we investigate the cases of impact sound, since it is usually reported as the most disturbing noise source in dwellings. We also evaluated the reviewed studies with the Bradford Hill’s criteria. The reviewed studies indicate that self-reported annoyance to impact sound is an important issue and it can be predicted well in overall. Various standardized descriptors are studied and associate sufficiently with subjective responses. Inclusion of low frequencies down to 50 Hz in measurements improves the association of impact sound descriptors to subjective responses. Some impact noise stimuli associate only with some descriptors but not all. From the standardized impact sources, the tapping machine is the most efficient to predict overall annoyance and the impact ball for human walking or typical impact sounds in dwellings.
- Open Access
- 19 March 2018
- Published by SAGE Publications in Building Acoustics
- Vol. 25 (2) , 151-170
Review of acoustic comfort evaluation in dwellings—part I: Associations of acoustic field data to subjective responses from building surveys
Acoustic comfort is a concept hardly described in the literature. But it has been used in engineering typically to refer to low noise or annoyance in order to invoke no discomfort. Current standardized methods for airborne and impact sound reduction are deployed to assess acoustic comfort in dwellings. However, the measured sound pressure levels do not represent comfort. The latter should include further the human perception of the acoustic environment. Therefore, this article reviews studies that approached acoustic comfort through the association of objective and subjective field data, combining in situ acoustic measurements and survey responses from residents. We evaluated the studies using Bradford Hill’s criteria. Most researches focus on self-reported noise annoyance while some others on satisfaction responses. Many studies were found incomprehensibly described: often vital data of statistical evaluation or study design are lacking. The results indicate that noise is a significant issue in living environments, especially certain impact noise types. The use of extended low-frequency spectra down to 50 Hz was suggested for impact measurements in order to predict better self-reported noise response. Greater problems with low-frequency transmission are displayed in lightweight structures which perform inefficiently compared to heavyweight components. Harmonization of presented results and study design details should be taken into account for future articles.
- 19 March 2018
- Published by SAGE Publications in Building Acoustics
- Vol. 25 (2) , 151-170
Open AccessReview of acoustic comfort evaluation in dwellings—part I: Associations of acoustic field data to subjective responses from building surveys
Acoustic comfort is a concept hardly described in the literature. But it has been used in engineering typically to refer to low noise or annoyance in order to invoke no discomfort. Current standardized methods for airborne and impact sound reduction are deployed to assess acoustic comfort in dwellings. However, the measured sound pressure levels do not represent comfort. The latter should include further the human perception of the acoustic environment. Therefore, this article reviews studies that approached acoustic comfort through the association of objective and subjective field data, combining in situ acoustic measurements and survey responses from residents. We evaluated the studies using Bradford Hill’s criteria. Most researches focus on self-reported noise annoyance while some others on satisfaction responses. Many studies were found incomprehensibly described: often vital data of statistical evaluation or study design are lacking. The results indicate that noise is a significant issue in living environments, especially certain impact noise types. The use of extended low-frequency spectra down to 50 Hz was suggested for impact measurements in order to predict better self-reported noise response. Greater problems with low-frequency transmission are displayed in lightweight structures which perform inefficiently compared to heavyweight components. Harmonization of presented results and study design details should be taken into account for future articles.