Zahoor Ahmad
Research Subjects
Zahoor Ahmad has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Abdul Qayyum
National Tokamak Fusion Program, Islamabad, Pakistan
3 shared publications - Asad Yaqoob Mian
Pakistan Tokamak Plasma Research Institute, Islamabad, Pakistan
3 shared publications - Azam Hussain
National Tokamak Fusion Program
3 shared publications - Kamran Ahmad
Pakistan Tokamak Plasma Research Institute, P.O. Box 3329, Islamabad, Pakistan
2 shared publications M A Naveed
2 shared publicationsS Hussain
2 shared publications
Latest Publications
- 16 June 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (26)
Plasma radiation simulation and tomographic reconstruction methods for multi-array bolometer system design on the MT-I spherical tokamak
Radiative losses from impurity species play a decisive role in determining the energy balance, performance and stability in fusion plasma devices. This article presents a comprehensive end-to-end simulation framework for the preliminary design of a multi-array Absolute Extreme Ultraviolet (AXUV) photodiode bolometry system for the MT-I spherical tokamak. The proposed configuration employs 48 viewing chords distributed across three poloidal arrays at ±45° and 90°, providing enhanced spatial coverage for elongated plasma geometries. The framework integrates impurity radiation modelling based on ADAS coronal equilibrium cooling coefficients for carbon, oxygen, and iron with a forward diagnostic model incorporating line-of-sight integration, etendue-based signal estimation, and detector response characteristics. Tomographic reconstruction is performed using Minimum Fisher Information regularization (MFR) and Phillips–Tikhonov regularization (PTR). Under 3% Gaussian noise, a conservative lower bound for realistic AXUV system uncertainties, both methods achieve stable and comparable accuracy; however, MFR demonstrates improved preservation of edge gradients, while PTR yields smoother and more robust solutions in noise-affected regions. Reconstruction fidelity is significantly enhanced by multi-angle coverage, reducing the root-mean-square error from approximately 18% in two-array configurations to approximately 11–12% with three arrays. Regularization parameters are optimized using L-curve analysis and the discrepancy principle, with the latter showing greater reliability for sparse-view conditions. This evaluated framework provides quantitative guidance for diagnostic design and establishes a reliable basis for radiant emission coefficient reconstruction and data interpretation in spherical tokamaks and other compact fusion devices.
- 16 June 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (26)
Plasma radiation simulation and tomographic reconstruction methods for multi-array bolometer system design on the MT-I spherical tokamak
Radiative losses from impurity species play a decisive role in determining the energy balance, performance and stability in fusion plasma devices. This article presents a comprehensive end-to-end simulation framework for the preliminary design of a multi-array Absolute Extreme Ultraviolet (AXUV) photodiode bolometry system for the MT-I spherical tokamak. The proposed configuration employs 48 viewing chords distributed across three poloidal arrays at ±45° and 90°, providing enhanced spatial coverage for elongated plasma geometries. The framework integrates impurity radiation modelling based on ADAS coronal equilibrium cooling coefficients for carbon, oxygen, and iron with a forward diagnostic model incorporating line-of-sight integration, etendue-based signal estimation, and detector response characteristics. Tomographic reconstruction is performed using Minimum Fisher Information regularization (MFR) and Phillips–Tikhonov regularization (PTR). Under 3% Gaussian noise, a conservative lower bound for realistic AXUV system uncertainties, both methods achieve stable and comparable accuracy; however, MFR demonstrates improved preservation of edge gradients, while PTR yields smoother and more robust solutions in noise-affected regions. Reconstruction fidelity is significantly enhanced by multi-angle coverage, reducing the root-mean-square error from approximately 18% in two-array configurations to approximately 11–12% with three arrays. Regularization parameters are optimized using L-curve analysis and the discrepancy principle, with the latter showing greater reliability for sparse-view conditions. This evaluated framework provides quantitative guidance for diagnostic design and establishes a reliable basis for radiant emission coefficient reconstruction and data interpretation in spherical tokamaks and other compact fusion devices.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (7) , 1-13
Impurity Radiation Simulation and Abel Inversion Methods for AXUV Bolometer Design for MT-I Tokamak
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (7) , 1-13
Impurity Radiation Simulation and Abel Inversion Methods for AXUV Bolometer Design for MT-I Tokamak
- 6 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (6) , 1-11
Development and Testing of Hybrid HTS Conductor for Steady-State High-Current Applications
Second-generation rare Earth REBCO high-temperature superconductors (HTSs) exhibit a high critical current density and a higher critical magnetic field. HTS materials have the potential to generate magnetic fields that overcome the limitations of low-temperature superconductors. A hybrid high-temperature superconductor (HHTS) was developed by soldering five HTS strips (GdBCO, SUNAM Korea, and 4 mm in width) without insulation (NI) into a copper stabilizer. In addition, five NI-HTS strips without stabilizers were tested at room temperature and in liquid nitrogen (LN2). For the HTS strips, a maximum stable current of 270 A (at LN2 temperature) was achieved at 0.08 V, beyond which the current dropped sharply. The critical electric field (Ec) calculated from the voltage drop was 14 μV/mm. The HHTS demonstrated a current-carrying capacity up to 1000 A at an applied voltage of just 0.2 V and a corresponding electric field of 6.8 μV/mm. The simulation of HHTS was performed by using H-formulation at the cross section, applying currents from 500 to 1000 A, while varying the stabilizer width to 7, 9, and 12 mm. The results indicate stable current conduction up to 1000 A. The copper matrix provides stability during interruption in the cooling system, and the electric field in the HHTS allows operation at higher currents, offering advantages in voltage control and cooling efficiency.
- 6 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (6) , 1-11
Development and Testing of Hybrid HTS Conductor for Steady-State High-Current Applications
Second-generation rare Earth REBCO high-temperature superconductors (HTSs) exhibit a high critical current density and a higher critical magnetic field. HTS materials have the potential to generate magnetic fields that overcome the limitations of low-temperature superconductors. A hybrid high-temperature superconductor (HHTS) was developed by soldering five HTS strips (GdBCO, SUNAM Korea, and 4 mm in width) without insulation (NI) into a copper stabilizer. In addition, five NI-HTS strips without stabilizers were tested at room temperature and in liquid nitrogen (LN2). For the HTS strips, a maximum stable current of 270 A (at LN2 temperature) was achieved at 0.08 V, beyond which the current dropped sharply. The critical electric field (Ec) calculated from the voltage drop was 14 μV/mm. The HHTS demonstrated a current-carrying capacity up to 1000 A at an applied voltage of just 0.2 V and a corresponding electric field of 6.8 μV/mm. The simulation of HHTS was performed by using H-formulation at the cross section, applying currents from 500 to 1000 A, while varying the stabilizer width to 7, 9, and 12 mm. The results indicate stable current conduction up to 1000 A. The copper matrix provides stability during interruption in the cooling system, and the electric field in the HHTS allows operation at higher currents, offering advantages in voltage control and cooling efficiency.
- 10 April 2022
- Published by Springer Nature in Reviews of Modern Plasma Physics
- Vol. 6 (1) , 1-25
Recent progress, liquid metal use as plasma facing component and vapor shielding of high heat flux
- 10 April 2022
- Published by Springer Nature in Reviews of Modern Plasma Physics
- Vol. 6 (1) , 1-25
Recent progress, liquid metal use as plasma facing component and vapor shielding of high heat flux
- 14 July 2020
- Published by IOP Publishing in Plasma Research Express
- Vol. 2 (3) , 035004
Development of magnetic diagnostics for Glass Spherical Tokamak (GLAST)
GLAST is a small spherical tokamak with an insulating vacuum vessel of pyrex. It has major and minor radii of 20 and 10 cm, respectively. Magnetic measurements play a fundamental role in plasma breakdown and start-up studies. This paper presents the development, fabrication, calibration, and installation of magnetic diagnostics on GLAST III Tokamak. Magnetic diagnostics consist of the flux loops, magnetic field pickup sensors, and Rogowski coil. The signals obtained from various coils are integrated with passive analog integrators. The experimental results obtained from these magnetic diagnostics are presented and discussed.
- 14 July 2020
- Published by IOP Publishing in Plasma Research Express
- Vol. 2 (3) , 035004
Development of magnetic diagnostics for Glass Spherical Tokamak (GLAST)
GLAST is a small spherical tokamak with an insulating vacuum vessel of pyrex. It has major and minor radii of 20 and 10 cm, respectively. Magnetic measurements play a fundamental role in plasma breakdown and start-up studies. This paper presents the development, fabrication, calibration, and installation of magnetic diagnostics on GLAST III Tokamak. Magnetic diagnostics consist of the flux loops, magnetic field pickup sensors, and Rogowski coil. The signals obtained from various coils are integrated with passive analog integrators. The experimental results obtained from these magnetic diagnostics are presented and discussed.
- 1 November 2019
- Published by Pleiades Publishing Ltd in High Temperature
- Vol. 57 (6) , 821-831
Optical Emission and Langmuir Probe Diagnostic Measurements in DC Electrode Pulse Discharge in Nitrogen
Optical emission of selected nitrogen bands is analyzed for different nitrogen fill pressure and input electrical power to find the changes in spectral intensities with changing discharge conditions....
- 1 November 2019
- Published by Pleiades Publishing Ltd in High Temperature
- Vol. 57 (6) , 821-831
Optical Emission and Langmuir Probe Diagnostic Measurements in DC Electrode Pulse Discharge in Nitrogen
Optical emission of selected nitrogen bands is analyzed for different nitrogen fill pressure and input electrical power to find the changes in spectral intensities with changing discharge conditions....
- 5 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (10) , 4729-4737
Start-Up Studies of GLAST-III Spherical Tokamak in the Presence of Poloidal Field
GLAST-III (glass spherical tokamak) is a small device having an aspect ratio of two (R/a= 2) with major radius R= 20 cm and minor radius a = 10 cm. Experiments are performed to examine the effect of increasing the poloidal field (PF) produced by poloidal coils as well as to study the effect of the inductance of PF coils on the plasma current formation. To investigate the GLAST-III plasma, several diagnostic tools such as Rogowski coil, loop voltage, photodiode, Optical emission spectroscopy, high-speed camera, and Langmuir probe are used. After optimizing the working pressure, the first experiment is performed using toroidal field coils and central solenoid along with radio frequency (RF) pre-ionization source. A plasma current of 1 kA is achieved for 1.2 ms. In later experiments, the effect of the poloidal magnetic field is also included. It is observed that with increasing the PF, the plasma current increases, attain a maximum value (5 kA) and then after a critical value of the applied poloidal magnetic field, the plasma current starts decreasing. Similarly, with the inclusion of inductor in series with the PF coils, the plasma current value is reduced and its pulse duration is increased. Both optical emission and Langmuir probe diagnostics results show a similar trend of the plasma current.
- 5 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (10) , 4729-4737
Start-Up Studies of GLAST-III Spherical Tokamak in the Presence of Poloidal Field
GLAST-III (glass spherical tokamak) is a small device having an aspect ratio of two (R/a= 2) with major radius R= 20 cm and minor radius a = 10 cm. Experiments are performed to examine the effect of increasing the poloidal field (PF) produced by poloidal coils as well as to study the effect of the inductance of PF coils on the plasma current formation. To investigate the GLAST-III plasma, several diagnostic tools such as Rogowski coil, loop voltage, photodiode, Optical emission spectroscopy, high-speed camera, and Langmuir probe are used. After optimizing the working pressure, the first experiment is performed using toroidal field coils and central solenoid along with radio frequency (RF) pre-ionization source. A plasma current of 1 kA is achieved for 1.2 ms. In later experiments, the effect of the poloidal magnetic field is also included. It is observed that with increasing the PF, the plasma current increases, attain a maximum value (5 kA) and then after a critical value of the applied poloidal magnetic field, the plasma current starts decreasing. Similarly, with the inclusion of inductor in series with the PF coils, the plasma current value is reduced and its pulse duration is increased. Both optical emission and Langmuir probe diagnostics results show a similar trend of the plasma current.
- 27 March 2017
- Published by IOP Publishing in Physica Scripta
- Vol. 92 (4) , 045601
Optimization of magnetic field system for glass spherical tokamak GLAST-III
GLAST-III (Glass Spherical Tokamak) is a spherical tokamak with aspect ratio A = 2. The mapping of its magnetic system is performed to optimize the GLAST-III tokamak for plasma initiation using a Hall probe. Magnetic field from toroidal coils shows 1/ R dependence which is typical with spherical tokamaks. Toroidal field (TF) coils can produce 875 Gauss field, an essential requirement for electron cyclotron resonance assisted discharge. The central solenoid (CS) of GLAST-III is an air core solenoid and requires compensation coils to reduce unnecessary magnetic flux inside the vessel region. The vertical component of magnetic field from the CS in the vacuum vessel region is reduced to 1.15 Gauss kA −1 with the help of a differential loop. The CS of GLAST can produce flux change up to 68 mVs. Theoretical and experimental results are compared for the current waveform of TF coils using a combination of fast and slow capacitor banks. Also the magnetic field produced by poloidal field (PF) coils is compared with theoretically predicted values. It is found that calculated results are in good agreement with experimental measurement. Consequently magnetic field measurements are validated. A tokamak discharge with 2 kA plasma current and pulse length 1 ms is successfully produced using different sets of coils.
- 27 March 2017
- Published by IOP Publishing in Physica Scripta
- Vol. 92 (4) , 045601
Optimization of magnetic field system for glass spherical tokamak GLAST-III
GLAST-III (Glass Spherical Tokamak) is a spherical tokamak with aspect ratio A = 2. The mapping of its magnetic system is performed to optimize the GLAST-III tokamak for plasma initiation using a Hall probe. Magnetic field from toroidal coils shows 1/ R dependence which is typical with spherical tokamaks. Toroidal field (TF) coils can produce 875 Gauss field, an essential requirement for electron cyclotron resonance assisted discharge. The central solenoid (CS) of GLAST-III is an air core solenoid and requires compensation coils to reduce unnecessary magnetic flux inside the vessel region. The vertical component of magnetic field from the CS in the vacuum vessel region is reduced to 1.15 Gauss kA −1 with the help of a differential loop. The CS of GLAST can produce flux change up to 68 mVs. Theoretical and experimental results are compared for the current waveform of TF coils using a combination of fast and slow capacitor banks. Also the magnetic field produced by poloidal field (PF) coils is compared with theoretically predicted values. It is found that calculated results are in good agreement with experimental measurement. Consequently magnetic field measurements are validated. A tokamak discharge with 2 kA plasma current and pulse length 1 ms is successfully produced using different sets of coils.