César Barajas-Olalde
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
César Barajas-Olalde has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Donald C. Adams
Univ. of North Dakota, Grand Forks, ND (United States). Energy & Environmental Research Center
8 shared publications USDOE Office of Fossil Energy and Carbon Management (FECM)
8 shared publications- Ryan J. Klapperich
Univ. of North Dakota, Grand Forks, ND (United States). Energy and Environmental Research Center
6 shared publications - Wesley D. Peck
Univ. of North Dakota, Grand Forks, ND (United States). Energy & Environmental Research Center
6 shared publications - Kris MacLennan
Univ. of North Dakota, Grand Forks, ND (United States). Energy & Environmental Research Center
5 shared publications - John A. Hamling
Univ. of North Dakota, Grand Forks, ND (United States). Energy & Environmental Research Center
4 shared publications
Latest Publications
- Open Access
- 29 October 2024
- Published by Office of Scientific and Technical Information (OSTI)
Novel Carbon Storage Monitoring Methods
Conference presentation at American Institute of Chemical Engineers (AIChE) Annual Meeting, San Diego, California, October 27–31, 2024. We presented a high-level overview of many novel and sustainable carbon storage monitoring methods that are at various stages of planning or demonstration to accelerate the deployment of CCS technologies at future CCS sites across the United States. Our work impacts the general CCS industry by providing novel and more sustainable methods for tracking CO2 plume migration and performing assurance monitoring. Our work primarily benefits three parties: 1) CCS community members through knowledge sharing of lessons learned; 2) CCS operators through commercialization of additional methods, including improvements on workflows and simplification of fieldwork; and 3) stakeholders of CCS projects through implementation of low-impact and more autonomous monitoring solutions.
- 29 October 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessNovel Carbon Storage Monitoring Methods
Conference presentation at American Institute of Chemical Engineers (AIChE) Annual Meeting, San Diego, California, October 27–31, 2024. We presented a high-level overview of many novel and sustainable carbon storage monitoring methods that are at various stages of planning or demonstration to accelerate the deployment of CCS technologies at future CCS sites across the United States. Our work impacts the general CCS industry by providing novel and more sustainable methods for tracking CO2 plume migration and performing assurance monitoring. Our work primarily benefits three parties: 1) CCS community members through knowledge sharing of lessons learned; 2) CCS operators through commercialization of additional methods, including improvements on workflows and simplification of fieldwork; and 3) stakeholders of CCS projects through implementation of low-impact and more autonomous monitoring solutions.
- 12 March 2024
- Published by Office of Scientific and Technical Information (OSTI)
Active Seismoelectric Monitoring of CO2 Injection
- 12 March 2024
- Published by Office of Scientific and Technical Information (OSTI)
Active Seismoelectric Monitoring of CO2 Injection
- Open Access
- 11 March 2024
- Published by Office of Scientific and Technical Information (OSTI)
Enhancing CO2 Storage Complex Characterization in the Williston Basin: An Integrated Approach of Petrophysical Evaluation and Core Analysis
Conference presentation at Carbon Capture, Utilization, and Storage (CCUS) Conference 2024, Houston, Texas, March 11–13, 2024. Petrophysics and core analysis are pivotal in carbon capture and storage (CCS). An integrated workflow including conventional and advanced well logs and core analysis (CCAL and SCAL) was developed to characterize the Broom Creek Formation as the target reservoir to store CO2 in a CCS project in North Dakota.
- 11 March 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessEnhancing CO2 Storage Complex Characterization in the Williston Basin: An Integrated Approach of Petrophysical Evaluation and Core Analysis
Conference presentation at Carbon Capture, Utilization, and Storage (CCUS) Conference 2024, Houston, Texas, March 11–13, 2024. Petrophysics and core analysis are pivotal in carbon capture and storage (CCS). An integrated workflow including conventional and advanced well logs and core analysis (CCAL and SCAL) was developed to characterize the Broom Creek Formation as the target reservoir to store CO2 in a CCS project in North Dakota.
- 24 November 2023
- Published by Elsevier in International Journal of Greenhouse Gas Control
- Vol. 130
Assessing pore network heterogeneity across multiple scales to inform CO2 injection models
- 24 November 2023
- Published by Elsevier in International Journal of Greenhouse Gas Control
- Vol. 130
Assessing pore network heterogeneity across multiple scales to inform CO2 injection models
- Open Access
Application of Electromagnetic Methods for Reservoir Monitoring with Emphasis on Carbon Capture, Utilization, and Storage
The Controlled-Source ElectroMagnetic (CSEM) method provides crucial information about reservoir fluids and their spatial distribution. Carbon dioxide (CO2) storage, enhanced oil recovery (EOR), geothermal exploration, and lithium exploration are ideal applications for the CSEM method. The versatility of CSEM permits its customization to specific reservoir objectives by selecting the appropriate components of a multi-component system. To effectively tailor the CSEM approach, it is essential to determine whether the primary target reservoir is resistive or conductive. This task is relatively straightforward in CO2 monitoring, where the injected fluid is resistive. However, for scenarios involving brine-saturated (water-wet) or oil-wet (carbon capture, utilization, and storage—CCUS) reservoirs, consideration must also be given to conductive reservoir components. The optimization of data acquisition before the survey involves analyzing target parameters and the sensitivity of multi-component CSEM. This optimization process typically includes on-site noise measurements and 3D anisotropic modeling. Based on our experience, subsequent surveys tend to proceed smoothly, yielding robust measurements that align with scientific objectives. Other critical aspects to be considered are using magnetotelluric (MT) measurements to define the overall background resistivities and integrating real-time quality assurance during data acquisition with 3D modeling. This integration allows the fine tuning of acquisition parameters such as acquisition time and necessary repeats. As a result, data can be examined in real-time to assess subsurface information content while the acquisition is ongoing. Consequently, high-quality data sets are usually obtained for subsequent processing and initial interpretation with minimal user intervention. The implementation of sensitivity analysis during the inversion process plays a pivotal role in ensuring that the acquired data accurately respond to the target reservoirs’ expected depth range. To elucidate these concepts, we present an illustrative example from a CO2 storage site in North Dakota, USA, wherein the long-offset transient electromagnetic method (LOTEM), a variation of the CSEM method, and the MT method were utilized. This example showcases how surface measurements attain appropriately upscaled log-scale sensitivity. Furthermore, the sensitivity of the CSEM and MT methods was examined in other case histories, where the target reservoirs exhibited conductive properties, such as those encountered in enhanced oil recovery (EOR), geothermal, and lithium exploration applications. The same equipment specifications were utilized for CSEM and MT surveys across all case studies.
Open AccessApplication of Electromagnetic Methods for Reservoir Monitoring with Emphasis on Carbon Capture, Utilization, and Storage
The Controlled-Source ElectroMagnetic (CSEM) method provides crucial information about reservoir fluids and their spatial distribution. Carbon dioxide (CO2) storage, enhanced oil recovery (EOR), geothermal exploration, and lithium exploration are ideal applications for the CSEM method. The versatility of CSEM permits its customization to specific reservoir objectives by selecting the appropriate components of a multi-component system. To effectively tailor the CSEM approach, it is essential to determine whether the primary target reservoir is resistive or conductive. This task is relatively straightforward in CO2 monitoring, where the injected fluid is resistive. However, for scenarios involving brine-saturated (water-wet) or oil-wet (carbon capture, utilization, and storage—CCUS) reservoirs, consideration must also be given to conductive reservoir components. The optimization of data acquisition before the survey involves analyzing target parameters and the sensitivity of multi-component CSEM. This optimization process typically includes on-site noise measurements and 3D anisotropic modeling. Based on our experience, subsequent surveys tend to proceed smoothly, yielding robust measurements that align with scientific objectives. Other critical aspects to be considered are using magnetotelluric (MT) measurements to define the overall background resistivities and integrating real-time quality assurance during data acquisition with 3D modeling. This integration allows the fine tuning of acquisition parameters such as acquisition time and necessary repeats. As a result, data can be examined in real-time to assess subsurface information content while the acquisition is ongoing. Consequently, high-quality data sets are usually obtained for subsequent processing and initial interpretation with minimal user intervention. The implementation of sensitivity analysis during the inversion process plays a pivotal role in ensuring that the acquired data accurately respond to the target reservoirs’ expected depth range. To elucidate these concepts, we present an illustrative example from a CO2 storage site in North Dakota, USA, wherein the long-offset transient electromagnetic method (LOTEM), a variation of the CSEM method, and the MT method were utilized. This example showcases how surface measurements attain appropriately upscaled log-scale sensitivity. Furthermore, the sensitivity of the CSEM and MT methods was examined in other case histories, where the target reservoirs exhibited conductive properties, such as those encountered in enhanced oil recovery (EOR), geothermal, and lithium exploration applications. The same equipment specifications were utilized for CSEM and MT surveys across all case studies.
- Open Access
- 31 August 2023
- Published by Office of Scientific and Technical Information (OSTI)
2D Seismic Surveys as an Alternative for CO2 Monitoring in the North Dakota CarbonSAFE Project
Conference presentation for International Meeting for Applied Geoscience & Energy (IMAGE), Houston, TX, August 28 – September 1, 2023. As part of the North Dakota CarbonSAFE project, seismic, controlled-source electromagnetic, and microgravity baseline monitoring surveys were collected to assess the safe, permanent, commercial-scale geologic storage of CO2 generated by the Milton R. Young coal-fired power plant. Data from five 2D seismic lines were assessed as an alternative to 3D seismic for CO2 monitoring. 2D and 3D surveys were compared using wave equation-based (WEB)-AVO inversion. The encouraging WEB-AVO results demonstrated that 2D surveys could be included in CO2 monitoring programs as a cost-effective method.
- 31 August 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open Access2D Seismic Surveys as an Alternative for CO2 Monitoring in the North Dakota CarbonSAFE Project
Conference presentation for International Meeting for Applied Geoscience & Energy (IMAGE), Houston, TX, August 28 – September 1, 2023. As part of the North Dakota CarbonSAFE project, seismic, controlled-source electromagnetic, and microgravity baseline monitoring surveys were collected to assess the safe, permanent, commercial-scale geologic storage of CO2 generated by the Milton R. Young coal-fired power plant. Data from five 2D seismic lines were assessed as an alternative to 3D seismic for CO2 monitoring. 2D and 3D surveys were compared using wave equation-based (WEB)-AVO inversion. The encouraging WEB-AVO results demonstrated that 2D surveys could be included in CO2 monitoring programs as a cost-effective method.
- Open Access
- 13 November 2022
- Published by Office of Scientific and Technical Information (OSTI)
On the Feasibility of Geophysical Methods for CO2 Monitoring in the North Dakota CarbonSAFE Project
Conference presentation at American Institute of Chemical Engineers (AIChE) Annual Meeting, Phoenix, AZ, November 13–18, 2022. An analysis of rock physics crossplots and diagnostic models suggests that the baseline seismic data may be sensitive to changes in lithology and porosity of the Broom Creek Formation and that these changes may be detectable by prestack seismic inversion.
- 13 November 2022
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessOn the Feasibility of Geophysical Methods for CO2 Monitoring in the North Dakota CarbonSAFE Project
Conference presentation at American Institute of Chemical Engineers (AIChE) Annual Meeting, Phoenix, AZ, November 13–18, 2022. An analysis of rock physics crossplots and diagnostic models suggests that the baseline seismic data may be sensitive to changes in lithology and porosity of the Broom Creek Formation and that these changes may be detectable by prestack seismic inversion.
- Open Access
- 1 September 2022
- Published by Office of Scientific and Technical Information (OSTI)
Quality Analysis of Baseline Time-Lapse CSEM Data CarbonSAFE Project, North Dakota
Conference presentation at International Meeting for Applied Geoscience & Energy (IMAGE), Houston, TX, August 28 – September 2, 2022. When a series of time-lapse CSEM surveys are designed to measure the often-small variations in signal seen in CCUS projects, the primary concern must be collecting the highest-quality data and reducing as much noise as possible. This includes optimization during planning and feasibility, careful and consistent quality checks in the field, and transparent and repeatable postprocessing steps. We apply this practice to a baseline (prior to CO2 injection) CSEM data set collected for a time-lapse survey in Center, North Dakota, as a part of the North Dakota CarbonSAFE project, and describe the rigorous quality control and assessment methods used, including noise removal and data validation with 1D and 3D inversion to tie results to borehole logs. The final result is an accurate and representative CSEM data set and information that stakeholders can use to inform future time-lapse survey costs and designs.
- 1 September 2022
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessQuality Analysis of Baseline Time-Lapse CSEM Data CarbonSAFE Project, North Dakota
Conference presentation at International Meeting for Applied Geoscience & Energy (IMAGE), Houston, TX, August 28 – September 2, 2022. When a series of time-lapse CSEM surveys are designed to measure the often-small variations in signal seen in CCUS projects, the primary concern must be collecting the highest-quality data and reducing as much noise as possible. This includes optimization during planning and feasibility, careful and consistent quality checks in the field, and transparent and repeatable postprocessing steps. We apply this practice to a baseline (prior to CO2 injection) CSEM data set collected for a time-lapse survey in Center, North Dakota, as a part of the North Dakota CarbonSAFE project, and describe the rigorous quality control and assessment methods used, including noise removal and data validation with 1D and 3D inversion to tie results to borehole logs. The final result is an accurate and representative CSEM data set and information that stakeholders can use to inform future time-lapse survey costs and designs.