YNYusuke Nakano

Yusuke Nakano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yusuke Nakano has a total of 85 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Transient extinction dynamics of ablation plasmas generated from PAA-H 2 O composite gels: combined numerical and experimental analysis

    by Yusuke Nakano, Masao Shibayama, Yasunori Tanaka, Tatsuo Ishijima

    Ablation-generated plasmas interacting with mixed polymer-water vapors exhibit rapid temporal changes in temperature, ionization, and electrical conductivity. Such transient behavior is governed by strong cooling, vapor-driven heat transport, and electron recombination, and is of fundamental importance in highly quenched arcs and stagnation-type plasma flows. This study investigates the extinction dynamics of plasmas formed from polyacrylic acid (PAA) gels containing absorbed water (PAA-H 2 O). A two-dimensional thermofluid model under local thermodynamic equilibrium was developed, incorporating separate ablation of PAA and H 2 O via a space-division method to reproduce selective evaporation. Experiments using a controlled capacitor-discharge plasma device provided synchronized electrical and optical diagnostics during the free-decay phase after current removal. Both simulation and experiment reveal a universal two-stage extinction process consisting of (i) radial contraction of the hot, conductive core and (ii) abrupt collapse of electrical conductivity. Increasing the H 2 O fraction significantly accelerates cooling through enhanced thermal conductivity, high heat capacity, and endothermic dissociation of H/O species, leading to shorter decay times. These results provide fundamental insight into the physics of vapor-controlled plasma extinction and clarify how composite ablation sources determine thermal and electrical relaxation in strongly cooled ablation plasmas.

  • Influence of O 2 content ratio on the properties of CO 2 / O 2 / C 4 F 7 N Mixtures and Arc Behaviors. -Equilibrium composition, thermodynamic and transport properties, and arc behavior

    by Tat Htut Aung, Yasunori Tanaka, Yusuke Nakano, Tatsuo Ishijima

    This study investigates the effect of oxygen (O 2 ) content on the behavior of CO 2 /O 2 /C 4 F 7 N gas mixtures, which have recently been proposed as environmentally sustainable alternatives to SF 6 for application in gas circuit breakers. Numerical thermofluid simulations of steady-state arcs were carried out using equilibrium particle compositions together with thermodynamic and transport properties such as specific heat capacity, thermal conductivity, and electrical conductivity. The results show that increasing the O 2 fraction strongly alters arc characteristics, most notably the temperature distribution, which exhibits a clear correlation with arc voltage. A higher O 2 concentration enhances arc constriction, reduces the plasma cross-sectional area during current interruption, and improves both arc stability and cooling performance.


  • Breakdown Characteristics of CO 2 Gas and CO 2 /O 2 Gas Mixtures at Temperatures above 3000 K

    by Yusuke Nakano, Yasunori Tanaka, Tatsuo Ishijima

    In gas circuit breakers (GCBs), high-temperature insulation gas remains between the electrodes after current interruption. If the dielectric withstand voltage of this residual gas is insufficient against the transient recovery voltage (TRV) from the circuit, a re-ignition arc may occur, potentially leading to an unsuccessful interruption. Therefore, understanding the dielectric breakdown characteristics of high-temperature gases is essential for evaluating the reliability of SF6-free GCBs in the future. However, experimental measurements of these characteristics have been challenging due to the difficulty of maintaining stable high-temperature gas conditions. This study investigates the dielectric breakdown properties of high-temperature CO2/O2 gas mixtures, a potential SF6-alternative insulation gas, by employing an inductively coupled thermal plasma (ICTP) method. This method enables controlled heating of insulation gases to temperatures exceeding 3000 K, ensuring a stable gas supply between the electrodes. Direct measurements of the breakdown voltage (BDV) were conducted under these extreme temperature conditions, supported by the temperature estimation of electrode region with electromagnetic thermofluid simulation. Experimental results revealed that, at room temperature, the BDV of CO2/O2 gas mixtures was higher than that of pure CO2 gas. However, in high-temperature conditions, this relationship reversed, with pure CO2 exhibiting a higher BDV than CO2/O2 gas mixtures.

  • Improving the Practicality of Innovative DC Circuit Breakers Using Linear Motors

    by Reon Sasaki, Wataru Ohnishi, Naoto Kodama, Yusuke Nakano, Shungo Zen, Yasushi Yamano, Yuki Inada

  • Comparative analysis of measured and calculated radiation intensities in polymer ablated arcs

    by Yusuke Nakano, Yasunori Tanaka, Tatsuo Ishijima

    The accurate prediction of radiation intensities in polymer-ablated arcs is crucial for optimizing the design and performance of electrical devices, such as circuit breakers, which rely on polymer ablation for arc control. In this study, both experimental measurements and numerical simulations were conducted to evaluate the radiation intensities of polymer-ablated arcs using a one-side flow outlet model. The experiment focused on light intensity profiles, while the numerical simulations accounted for the distribution of radiation coefficients derived from temperature and mass fraction of vaporized polymers. To accurately capture the arc behavior, the radiation coefficient was calculated considering both molecular and atomic spectra, with particular attention to the C2 Swan bands and Hα/Hβ atomic lines. The model effectively reproduced the experimentally measured light intensity distributions for different polymers—PA6, POM, and PTFE—despite the complexity of the radiative transfer calculations. Significant variations in radiation intensity between the polymers were attributed to differences in molecular composition and ablation characteristics. This study demonstrates that even a simplified approach to calculating radiation coefficients, using mean absorption coefficients and axisymmetric assumptions, provides results in strong agreement with experimental data. The findings highlight the essential role of molecular spectra in predicting and diagnosing polymer-contaminated arc characteristics, such as plasma temperature and polymer vapor distributions. Comparison between experimental measurements of light intensity and the calculated intensity distributions enables the accurate estimation of number density distributions of each of species in the arc plasmas, significantly advancing the understanding of polymer-vapor contaminated arcs.


  • Development of Numerical Model for Small- Current Vacuum Arc Decay Process Using a Hybrid of Moving Particle Semi-Implicit Method and Finite Volume Method

    by Daisuke Kasui, Yusuke Nakano, Yasunori Tanaka, Tatsuo Ishijima, Shinji Yamamoto, Gaku Asanuma, Toshiyuki Onchi

    In this study, a hybrid numerical simulation model using the moving particle semi-implicit (MPS) method and the finite volume method (FVM) was constructed to analyze vacuum arc discharges. Vacuum arc discharges can be seen in vacuum circuit breakers (VCBs). The VCBs have been receiving much attention from their low environmental impact, because they do not use $\mathbf{SF_6}$ gas in the interrupter. In order to improve the current interruption performance of such VCBs, it is important to understand the behavior of vacuum arcs, such as the distribution of metal vapor and ionization and excitation states that affect electrical conductivity. In this article, the arc characteristics of the vacuum arc decay process and its dependence on the current decay rate were studied. Results indicated that the gradual decrease in current to 10 A maintained high evaporative vapor amount above 60 $\mathbf{~kg/(m^2\cdot s)}$ . This suppressed the decrease in the number of heavy particles between the electrodes.


  • Fault and Load Current Interruption in Low-Voltage System Using Fuse-Semiconductor Current-Limiting Circuit Breaker

    by Yuki Inada, Shungo Zen, Wataru Ohnishi, Naoto Kodama, Yusuke Nakano, Yasuhiro Takada, Reon Sasaki, Yuta Miyaoka, Kosuke Tsukamoto, Keiya Yamada, et al.

    For the realization of carbon neutrality and an advanced information society, we have previously developed a novel current-limiting circuit breaker composed of a fuse, a power semiconductor and a fuse exchanger. However, its feasibility has been confirmed only for fault current interruption in a low voltage range of 100-500V. In this paper, the current-limiting circuit breaker was successfully used for fault and load current interruption at DC 1.5kV, thus demonstrating the high versatility of the circuit breaker.


  • Open Access

    Experimental and Numerical Study on Polymer Ablated Arc Characteristics with One Side Flow Outlet Model

    by Yusuke Nakano, Yasunori Tanaka, Tatsuo Ishijima

    An experimental and numerical study was conducted on the polymer ablated arc with an electrode configuration of a one-side gas flow outlet model. The polymers used for molded case circuit breaker and gas circuit breaker, such as PA6, POM, and PTFE, were compared. In the experiment, the polymer ablated arc characteristics of arc voltage, arc energy, and mass loss of polymer by ablation were measured. In the numerical calculation, an electromagnetic thermofluid simulation for polymer ablated arc was conducted using a calculation model of similar structure but without using empirical values. In the model used, the polymer ablation was treated as the pyrolytic ablation rather the photodegraded ablation because the arc plasma was definitely in contact with the polymer. The comparison of both experiment and numerical simulation results revealed the relationship between arc energy and mass loss of polymer by ablation, and these values agreed well. Therefore, the numerical simulation model with pyrolytic ablation developed was indicated to be valid for predicting the polymer ablated arc with plasma-polymer contact.


  • Evaluation of Electrical Insulation Properties of High Temperature Gas Heated by Inductively Coupled Thermal Plasma

    by Yusuke Nakano, Koya Ishinokoshi, Rio Okano, Yasunori Tanaka, Tatsuo Ishijima

    The success or failure of interruption in a gas circuit breaker (GCB) is determined by a dielectric strength of high-temperature gas remaining between electrodes against a transient recovery voltage (TRV). To contribute for a high reliable interruption performance of SF 6 gas alternative circuit breakers being developed, we have developed a unique method to evaluate the insulation characteristics of high temperature gas. This paper presents a concept of a method for increasing the temperature of insulation gas using inductively coupled thermal plasma (ICTP). Then, the results of temperature estimation of high-temperature CO 2 gas by a spectroscopy and dielectric breakdown test results are presented. Finally, by the electromagnetic thermofluid simulation, the gas temperature in the electrode space calculated is shown, and we suggest the applicability of the unique method for the reliable dielectric test of high temperature insulation gas.