Zirui Rong has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Neng Jin
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, China
5 shared publications - Zhengtian Li
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, China
5 shared publications - Le Chen
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, China
3 shared publications - Ning Tong
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, China
3 shared publications - Xiangning Lin
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, China
3 shared publications Haibo Xu
EAST Group Company Ltd., Dongguan, China
2 shared publications
Latest Publications
- Open Access
- 30 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 130212-130220
A Novel DC Bias Suppression Method Considering the Cooperation of Multiple Devices
The dc bias phenomenon caused by the excessive current of the neutral point will pose significant threats to the transformers. The conventional suppression method based on capacitive dc blocking device (BD) can prevent dc bias current from penetrating the transformer winding and is the most widely used. However, due to the high investment cost of the BD, it is not appropriate to install the BD for all transformers around the grounding electrode. Thus the BD may redirect the dc flow from one transformer with a BD to the peripheral transformers without BDs, causing the neutral current to exceed undesirably. To address the problems above, a new type of current balancing device (CBD) is introduced, which can lead to flexible suppression of neutral current. Based on coordination between the BD and CBD, a global optimization configuration method is proposed. Unlike the existing suppression strategy based on dc bias suppression devices, the proposed method optimizes the configuration of suppression devices for each transformer from a global perspective in the planning stage, which is an effective supplement to the current suppression method. MATLAB-based simulation results verify the effectiveness and superiority of the proposed method by numerous comparative case studies.
- 30 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 130212-130220
Open AccessA Novel DC Bias Suppression Method Considering the Cooperation of Multiple Devices
The dc bias phenomenon caused by the excessive current of the neutral point will pose significant threats to the transformers. The conventional suppression method based on capacitive dc blocking device (BD) can prevent dc bias current from penetrating the transformer winding and is the most widely used. However, due to the high investment cost of the BD, it is not appropriate to install the BD for all transformers around the grounding electrode. Thus the BD may redirect the dc flow from one transformer with a BD to the peripheral transformers without BDs, causing the neutral current to exceed undesirably. To address the problems above, a new type of current balancing device (CBD) is introduced, which can lead to flexible suppression of neutral current. Based on coordination between the BD and CBD, a global optimization configuration method is proposed. Unlike the existing suppression strategy based on dc bias suppression devices, the proposed method optimizes the configuration of suppression devices for each transformer from a global perspective in the planning stage, which is an effective supplement to the current suppression method. MATLAB-based simulation results verify the effectiveness and superiority of the proposed method by numerous comparative case studies.
- Open Access
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 126967-126975
A System-Level Suppression Method for DC Bias Based on Reverse Unbalanced Currents in the Same Transmission Section
Conventional dc bias suppression strategies mainly rely on a single type of device, such as blocking capacitor or blocking resistance. However, these methods are passive palliatives and cannot restrain dc bias currents from the sources. In the light of this, a system-level suppression method for dc bias is proposed in this paper. The average value of currents flowing through the earth is offset by actively generating unbalanced current through other dc projects in the same transmission section, which will reduce the currents flowing into the neutral transformers and alleviate the negative impacts of dc bias. First, the feasibility of the same section dc continuous power support is analyzed. Then the dc bias suppression strategy based on reverse unbalanced currents is elaborated. By scanning all the theoretical operable solutions of unbalanced current generation modes and the possible switching combinations of blocking capacitors, the optimal dc bias suppression solution is output considering the number of adjusted dc projects, the overload margin of dc projects and neutral dc currents of transformers. The effectiveness and superiority of the proposed method are verified by comparative case studies of the East China power grid.
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 126967-126975
Open AccessA System-Level Suppression Method for DC Bias Based on Reverse Unbalanced Currents in the Same Transmission Section
Conventional dc bias suppression strategies mainly rely on a single type of device, such as blocking capacitor or blocking resistance. However, these methods are passive palliatives and cannot restrain dc bias currents from the sources. In the light of this, a system-level suppression method for dc bias is proposed in this paper. The average value of currents flowing through the earth is offset by actively generating unbalanced current through other dc projects in the same transmission section, which will reduce the currents flowing into the neutral transformers and alleviate the negative impacts of dc bias. First, the feasibility of the same section dc continuous power support is analyzed. Then the dc bias suppression strategy based on reverse unbalanced currents is elaborated. By scanning all the theoretical operable solutions of unbalanced current generation modes and the possible switching combinations of blocking capacitors, the optimal dc bias suppression solution is output considering the number of adjusted dc projects, the overload margin of dc projects and neutral dc currents of transformers. The effectiveness and superiority of the proposed method are verified by comparative case studies of the East China power grid.
- 14 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (3) , 1476-1487
Countermeasure on Preventing Line Zero-Sequence Overcurrent Protection From Mal-Operation Due to Magnetizing Inrush
With the capability of limiting the increasing short-circuit current of power grid, high voltage built-in high-impedance transformer has been widely used in recent years. However, due to its special structure, the magnetizing inrush with high magnitude and slow decay is likely to occur during no-load energization, which may lead to the mal-operation of zero-sequence overcurrent protection of the upstream transmission line. This phenomenon has become a serious problem in the actual production in China. To solve this problem, a modified time difference method is proposed based on the substation area information, so as to accurately identify the magnetizing inrush, internal fault as well as current transformer saturation. Subsequently, a countermeasure on preventing line zero-sequence overcurrent protection from mal-operation due to HV built-in high-impedance transformer energization is proposed. Simulation results based on PSCAD indicate that the proposed protection scheme can cope with various kinds of energization and fault situations effectively. Thus, the correct operation of zero-sequence overcurrent protection can be ensured. Compared with other existing identification methods of magnetizing inrush, the proposed method shows great superiority.
- 14 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (3) , 1476-1487
Countermeasure on Preventing Line Zero-Sequence Overcurrent Protection From Mal-Operation Due to Magnetizing Inrush
With the capability of limiting the increasing short-circuit current of power grid, high voltage built-in high-impedance transformer has been widely used in recent years. However, due to its special structure, the magnetizing inrush with high magnitude and slow decay is likely to occur during no-load energization, which may lead to the mal-operation of zero-sequence overcurrent protection of the upstream transmission line. This phenomenon has become a serious problem in the actual production in China. To solve this problem, a modified time difference method is proposed based on the substation area information, so as to accurately identify the magnetizing inrush, internal fault as well as current transformer saturation. Subsequently, a countermeasure on preventing line zero-sequence overcurrent protection from mal-operation due to HV built-in high-impedance transformer energization is proposed. Simulation results based on PSCAD indicate that the proposed protection scheme can cope with various kinds of energization and fault situations effectively. Thus, the correct operation of zero-sequence overcurrent protection can be ensured. Compared with other existing identification methods of magnetizing inrush, the proposed method shows great superiority.
- 29 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (2) , 654-664
Phase-Space-Based Pilot Main Protection for a Transmission Line Immune to Timing Attack and Controllable Shunt Reactors
Pilot current differential protection for transmission lines is an important part of ensuring the safety of the power grid. The loss of data synchronization due to cyberattacks and the uncertain compensation degree of controllable shunt reactors will evidently deteriorate the performance of pilot current differential protection and may lead to the maloperation of the protection if no effective countermeasure is implemented. To address the above problems, a novel line pilot protection criterion based on the recognition of the phase space trajectory is proposed. First, the basic principle of phase space and its parameter selection scheme are analyzed. Then, the fault component instantaneous power difference (FCIPD) is selected as the time series for phase space reconstruction, and the distribution characteristics of the phase space trajectory of the FCIPD under different conditions are analyzed. Subsequently, a novel pilot main protection criterion for a transmission line is proposed. PSCAD/EMTDC-based simulation results verify that the proposed criterion is immune to timing attack and controllable shunt reactors and has the advantages of free setting, high speed and high-fault-resistance tolerance capability.
- 29 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (2) , 654-664
Phase-Space-Based Pilot Main Protection for a Transmission Line Immune to Timing Attack and Controllable Shunt Reactors
Pilot current differential protection for transmission lines is an important part of ensuring the safety of the power grid. The loss of data synchronization due to cyberattacks and the uncertain compensation degree of controllable shunt reactors will evidently deteriorate the performance of pilot current differential protection and may lead to the maloperation of the protection if no effective countermeasure is implemented. To address the above problems, a novel line pilot protection criterion based on the recognition of the phase space trajectory is proposed. First, the basic principle of phase space and its parameter selection scheme are analyzed. Then, the fault component instantaneous power difference (FCIPD) is selected as the time series for phase space reconstruction, and the distribution characteristics of the phase space trajectory of the FCIPD under different conditions are analyzed. Subsequently, a novel pilot main protection criterion for a transmission line is proposed. PSCAD/EMTDC-based simulation results verify that the proposed criterion is immune to timing attack and controllable shunt reactors and has the advantages of free setting, high speed and high-fault-resistance tolerance capability.
- 16 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 3085-3094
Research on Multiterminal Current Differential Protection Criterion With High Sensitivity and Synchronization Error Tolerance Capability
As the most suitable main protection for multi-terminal transmission lines represented by T-connections, current differential protection exhibits great performance due to its high reliability and sensitivity. However, considering multiple substations geographically, there are more severe problems of data synchronization for multi-terminal current differential protection than for double-terminal types based on a typical channel. To solve the aforementioned problems, the operating characteristics of multi-terminal line differential protection under different synchronization errors on the - plane are first analyzed. Based on the influence of synchronization errors on the magnitude and phase of the protection operating value, a design method for the restraint current of multi-terminal current differential protection is proposed. To achieve the sensitivity of a high resistance internal fault, as well as the tolerance capability of the data phase-shift error, double restraint coefficients are introduced to optimize the shape and area of the restraint region. Subsequently, the setting method is inferred, which can be used as a reference for an engineering application and the promotion of multi-terminal line differential protection. Finally, the simulation results indicate that the proposed method can significantly improve the criterion security for the case of additional data synchronization errors while maintaining the sensitivity of the internal fault.
- 16 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 3085-3094
Research on Multiterminal Current Differential Protection Criterion With High Sensitivity and Synchronization Error Tolerance Capability
As the most suitable main protection for multi-terminal transmission lines represented by T-connections, current differential protection exhibits great performance due to its high reliability and sensitivity. However, considering multiple substations geographically, there are more severe problems of data synchronization for multi-terminal current differential protection than for double-terminal types based on a typical channel. To solve the aforementioned problems, the operating characteristics of multi-terminal line differential protection under different synchronization errors on the - plane are first analyzed. Based on the influence of synchronization errors on the magnitude and phase of the protection operating value, a design method for the restraint current of multi-terminal current differential protection is proposed. To achieve the sensitivity of a high resistance internal fault, as well as the tolerance capability of the data phase-shift error, double restraint coefficients are introduced to optimize the shape and area of the restraint region. Subsequently, the setting method is inferred, which can be used as a reference for an engineering application and the promotion of multi-terminal line differential protection. Finally, the simulation results indicate that the proposed method can significantly improve the criterion security for the case of additional data synchronization errors while maintaining the sensitivity of the internal fault.