Hyunkyu Ouh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hyunkyu Ouh has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Matthew L. Johnston
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
3 shared publications - Boyu Shen
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
1 shared publication - Jinyong Kim
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
1 shared publication
Latest Publications
- 17 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (6) , 1419-1429
Multi-Channel Biopotential Acquisition System Using Frequency-Division Multiplexing With Cable Motion Artifact Suppression
A multi-channel, CMOS-based biopotential acquisition system is presented that uses amplitude modulated, frequency division multiplexing (AM-FDM) to decrease wire count and provide resilience against motion artifacts and cable noise. Differential active electrode (AE) pairs capture surface biopotential signals, each modulated by a different carrier frequency and combined via current-domain summing. The presented approach requires only a single wire for signal transmission between AEs and back-end readout, along with clock and ground wires, to support multiple active electrodes using a 3-wire cable. Frequency modulation prior to transmission mitigates the effect of low-frequency cable motion artifacts and 50/60 Hz mains interference in the cable. A prototype FDM-based biopotential acquisition system was implemented in a 180 nm CMOS process, including a four-channel front-end active electrode IC for signal conditioning and modulation, and a back-end IC for demodulation and digitization. Each channel occupies 0.75 mm$^\text{2}$ and consumes 43.8$\mu$ W, inclusive of ADC power. Using both AE and BE ICs, a four-channel biopotential recording system is demonstrated using a 3-wire interface, where the system achieves attenuation of low-frequency cable motion artifacts by 15X and 60 Hz mains noise coupled into the cable by 62X.- 17 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (6) , 1419-1429
Multi-Channel Biopotential Acquisition System Using Frequency-Division Multiplexing With Cable Motion Artifact Suppression
A multi-channel, CMOS-based biopotential acquisition system is presented that uses amplitude modulated, frequency division multiplexing (AM-FDM) to decrease wire count and provide resilience against motion artifacts and cable noise. Differential active electrode (AE) pairs capture surface biopotential signals, each modulated by a different carrier frequency and combined via current-domain summing. The presented approach requires only a single wire for signal transmission between AEs and back-end readout, along with clock and ground wires, to support multiple active electrodes using a 3-wire cable. Frequency modulation prior to transmission mitigates the effect of low-frequency cable motion artifacts and 50/60 Hz mains interference in the cable. A prototype FDM-based biopotential acquisition system was implemented in a 180 nm CMOS process, including a four-channel front-end active electrode IC for signal conditioning and modulation, and a back-end IC for demodulation and digitization. Each channel occupies 0.75 mm$^\text{2}$ and consumes 43.8$\mu$ W, inclusive of ADC power. Using both AE and BE ICs, a four-channel biopotential recording system is demonstrated using a 3-wire interface, where the system achieves attenuation of low-frequency cable motion artifacts by 15X and 60 Hz mains noise coupled into the cable by 62X.- 14 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 55 (2) , 392-403
Combined In-Pixel Linear and Single-Photon Avalanche Diode Operation With Integrated Biasing for Wide-Dynamic-Range Optical Sensing
This article presents a fully integrated, wide linear dynamic range (DR) optical sensor array combining linear and single-photon avalanche diode (SPAD) operation within each pixel. A pulse-counting readout scheme provides in-pixel digitization in an area-efficient manner for both the operation modes, enabling fully parallel measurement across the array. The proposed dual-mode optical sensor array alternately requires high-voltage (10-20 V) and low-voltage supply (2-5 V) for reverse bias of the photodiodes, which is provided by a reconfigurable, closed-loop high-voltage charge pump in the same substrate. An 8 x 8 array architecture along with the dual-mode bias generator is fabricated in a general purpose 180-nm CMOS process and demonstrates 129-dB DR while maintaining linear photoresponse operating with a dual-mode frame rate of 20 Hz. We present a pixel design methodology for implementing a dual-mode optical sensor scalable to an array format, as well as high-voltage dc-dc conversion in a low-voltage CMOS process.
- 14 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 55 (2) , 392-403
Combined In-Pixel Linear and Single-Photon Avalanche Diode Operation With Integrated Biasing for Wide-Dynamic-Range Optical Sensing
This article presents a fully integrated, wide linear dynamic range (DR) optical sensor array combining linear and single-photon avalanche diode (SPAD) operation within each pixel. A pulse-counting readout scheme provides in-pixel digitization in an area-efficient manner for both the operation modes, enabling fully parallel measurement across the array. The proposed dual-mode optical sensor array alternately requires high-voltage (10-20 V) and low-voltage supply (2-5 V) for reverse bias of the photodiodes, which is provided by a reconfigurable, closed-loop high-voltage charge pump in the same substrate. An 8 x 8 array architecture along with the dual-mode bias generator is fabricated in a general purpose 180-nm CMOS process and demonstrates 129-dB DR while maintaining linear photoresponse operating with a dual-mode frame rate of 20 Hz. We present a pixel design methodology for implementing a dual-mode optical sensor scalable to an array format, as well as high-voltage dc-dc conversion in a low-voltage CMOS process.
- 12 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 1 (5) , 118-121
Code-Division Multiplex Encoding Analog Front End for Current-Mode Sensor Arrays
This paper presents a new approach for applying orthogonal code-division multiplex encoding to current-mode sensor arrays with analog-domain encoding directly in the column readout circuitry, which enables simultaneous readout for multiple sensors. The approach is applied to a 8 x 16 array of CMOS-integrated photodetectors and implemented in a general purpose 180 nm CMOS process. The sensor array demonstrates 63 dB SNR with an array-wide sampling rate of 100 Hz with 16-channel encoding, an improvement of more than 12 dB compared with time-division multiplexing at the same sampling rate. The complete photodetector array consumes 5 mW total power. This work represents the first reported code-division multiplexed sensing architecture with analog-encoding front end, and the orthogonal coding scheme is broadly applicable to electronic current-mode sensor arrays for physical, chemical, and biological sensing applications without requiring sensor input encoding.
- 12 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 1 (5) , 118-121
Code-Division Multiplex Encoding Analog Front End for Current-Mode Sensor Arrays
This paper presents a new approach for applying orthogonal code-division multiplex encoding to current-mode sensor arrays with analog-domain encoding directly in the column readout circuitry, which enables simultaneous readout for multiple sensors. The approach is applied to a 8 x 16 array of CMOS-integrated photodetectors and implemented in a general purpose 180 nm CMOS process. The sensor array demonstrates 63 dB SNR with an array-wide sampling rate of 100 Hz with 16-channel encoding, an improvement of more than 12 dB compared with time-division multiplexing at the same sampling rate. The complete photodetector array consumes 5 mW total power. This work represents the first reported code-division multiplexed sensing architecture with analog-encoding front end, and the orthogonal coding scheme is broadly applicable to electronic current-mode sensor arrays for physical, chemical, and biological sensing applications without requiring sensor input encoding.