Stephan Westerdick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stephan Westerdick has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Musch
Institute of Electronic Circuits, Ruhr University Bochum, Bochum, Germany
2 shared publications - Benedikt Janßen
Embedded Systems for Information Technology, Ruhr University Bochum, 44801 Bochum, Germany
1 shared publication Martin Gevers
Institute of Electronic Circuits, Ruhr University Bochum, Bochum, Germany
1 shared publication- Michael Vogt
Institute of Electronic Circuits, Ruhr University Bochum, 44801 Bochum, Germany
1 shared publication - Patrick Hermanns
Electrical Engineering and Plasma Technology, Ruhr University Bochum, Ruhr-Universitaet, Gebauede ID, ID 1/537, Bochum, NRW, 44801, GERMANY
1 shared publication Patrik Gebhardt
Institute of Electronic Circuits, Ruhr University Bochum, Bochum, Germany
1 shared publication
Latest Publications
- Open Access
- 30 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 1071
Exchangeable Miniaturized Mass Spectrometer Chip Based on Silicon Structures
This paper reports a design of an exchangeable miniaturized mass spectrometry chip using spring-loaded pins and O-rings for electrical and fluidic connections. This planar microelectromechanical system (MEMS)-chip works with 300 µm high silicon structures between two borosilicate glasses and has a size of 13 mm × 7 mm. Because of its small size a small vacuum pump is sufficient, and it is suitable for mobile measurements and portable applications. Because of exchangeability of MEMS-chips with fluidic and electrical high voltage connections a direct comparison between chips is possible.
- 30 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 1071
Open AccessExchangeable Miniaturized Mass Spectrometer Chip Based on Silicon Structures
This paper reports a design of an exchangeable miniaturized mass spectrometry chip using spring-loaded pins and O-rings for electrical and fluidic connections. This planar microelectromechanical system (MEMS)-chip works with 300 µm high silicon structures between two borosilicate glasses and has a size of 13 mm × 7 mm. Because of its small size a small vacuum pump is sufficient, and it is suitable for mobile measurements and portable applications. Because of exchangeability of MEMS-chips with fluidic and electrical high voltage connections a direct comparison between chips is possible.
- 19 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 64 (5) , 1188-1195
Fast Electrical Impedance Tomography Based on Code-Division-Multiplexing Using Orthogonal Codes
Electrical impedance tomography (EIT) is used to determine the spatial conductivity distribution of a measurement environment that involves several applications in the areas of process engineering and medical diagnostics. In common EIT systems, the measurements are performed by means of current patterns which are injected into the measurement environment using a serial time-division-multiplexing (TDM) scheme for the excitation of different electrodes. The measurement rate can be increased by performing parallel excitation using orthogonal signals. In this paper, a code-division-multiplexing (CDM) measurement procedure is presented. To optimize the separation between different measurement channels and the dynamic range, orthogonal Walsh-Hadamard codes are used. The measurements are conducted with a fast EIT system with nine parallel excitation sources and 18 parallel measurement channels. The measured crosstalk rejection between different channels is larger than 98 dB. The maximum absolute deviation between different measurement sets for repeated measurements is less than 24 μV with a mean standard deviation of less than 8.2 μV. The dynamic range for impedance measurements based on different excitation procedures (TDM, frequency-division-multiplexing, and CDM) has been determined. Furthermore, reconstructed conductivity distributions based on measurements with the different excitation procedures have been compared with each other for different measurement scenarios (a root mean square difference of less than 1.2%). Finally, the influences of frequency-dependent measurement objects on the excitation procedures have been discussed.
- 19 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 64 (5) , 1188-1195
Fast Electrical Impedance Tomography Based on Code-Division-Multiplexing Using Orthogonal Codes
Electrical impedance tomography (EIT) is used to determine the spatial conductivity distribution of a measurement environment that involves several applications in the areas of process engineering and medical diagnostics. In common EIT systems, the measurements are performed by means of current patterns which are injected into the measurement environment using a serial time-division-multiplexing (TDM) scheme for the excitation of different electrodes. The measurement rate can be increased by performing parallel excitation using orthogonal signals. In this paper, a code-division-multiplexing (CDM) measurement procedure is presented. To optimize the separation between different measurement channels and the dynamic range, orthogonal Walsh-Hadamard codes are used. The measurements are conducted with a fast EIT system with nine parallel excitation sources and 18 parallel measurement channels. The measured crosstalk rejection between different channels is larger than 98 dB. The maximum absolute deviation between different measurement sets for repeated measurements is less than 24 μV with a mean standard deviation of less than 8.2 μV. The dynamic range for impedance measurements based on different excitation procedures (TDM, frequency-division-multiplexing, and CDM) has been determined. Furthermore, reconstructed conductivity distributions based on measurements with the different excitation procedures have been compared with each other for different measurement scenarios (a root mean square difference of less than 1.2%). Finally, the influences of frequency-dependent measurement objects on the excitation procedures have been discussed.