Krzysztof Kantyka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Krzysztof Kantyka has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Władysław Kryłłowicz
Institute of Turbomachinery, Lodz University of Technology, Poland
2 shared publications - Filip Grapow
Institute of Turbomachinery, Lodz University of Technology, 90 - 924 Lodz, 219/223 Wolczanska Street, Poland
1 shared publication - Paweł Pełczyński
Centre of Papermaking and Printing, Lodz University of Technology, Wólczańska 221, 95-003 Łódź, Poland
1 shared publication - Piotr Bogusław Jasiński
Institute of Turbomachinery, Lodz University of Technology, Wólczańska Str. 217/221, 93-005 Łódź, Poland
1 shared publication - Piotr Szymczak
Institute of Turbomachinery, Lodz University of Technology, Wólczańska Str. 217/221, 93-005 Łódź, Poland
1 shared publication - Włodzimierz Szewczyk
Centre of Papermaking and Printing, Lodz University of Technology, Wólczańska 221, 95-003 Łódź, Poland
1 shared publication
Latest Publications
- Open Access
Comparative Numerical Analysis of Thermal–FlowCharacteristics of Heat Exchanger Channels with Different Flow Turbulization Methods Using Performance Evaluation Criteria
This article presents the results of a numerical CFD study of heat exchanger channels with passive heat transfer enhancement methods. Two types of channel geometry were analyzed with different flow turbulization methods. In case I, internal micro-fins were applied to the tube wall, which disturbed the flow directly in the boundary layer; the investigated relative fin heights ranged from 0.01 h/D to 0.08 h/D, and the dimensionless longitudinal spacing varied from 0.92 L/D to 3.27 L/D. In case II, an insert with repeating drop-shaped elements was used, causing fluid turbulization in the tube core; the relative droplet diameter ranged from 0.38 d/D to 0.73 d/D, with the same longitudinal spacing as for the fins. The influence of the geometry and longitudinal spacing of the disturbance elements on the thermal–flow characteristics of such channels, namely, the friction factor, Nusselt number, and thermal efficiency evaluated using the PEC, was investigated over a Reynolds number range of 5000 to 400,000. The results show that the insert produces a larger increase in the Nusselt number, whereas the micro-finned tube generally achieves higher PEC values due to lower hydraulic losses. The results clearly indicate that, in most cases, the PEC is higher for the finned tube, particularly at low Reynolds numbers not exceeding 50,000. In turn, for the insert, the longitudinal distance between the elements, L, has a significant influence on the PEC; as L increases, the PEC also increase, reaching its maximum value for the largest L.
Open AccessComparative Numerical Analysis of Thermal–FlowCharacteristics of Heat Exchanger Channels with Different Flow Turbulization Methods Using Performance Evaluation Criteria
This article presents the results of a numerical CFD study of heat exchanger channels with passive heat transfer enhancement methods. Two types of channel geometry were analyzed with different flow turbulization methods. In case I, internal micro-fins were applied to the tube wall, which disturbed the flow directly in the boundary layer; the investigated relative fin heights ranged from 0.01 h/D to 0.08 h/D, and the dimensionless longitudinal spacing varied from 0.92 L/D to 3.27 L/D. In case II, an insert with repeating drop-shaped elements was used, causing fluid turbulization in the tube core; the relative droplet diameter ranged from 0.38 d/D to 0.73 d/D, with the same longitudinal spacing as for the fins. The influence of the geometry and longitudinal spacing of the disturbance elements on the thermal–flow characteristics of such channels, namely, the friction factor, Nusselt number, and thermal efficiency evaluated using the PEC, was investigated over a Reynolds number range of 5000 to 400,000. The results show that the insert produces a larger increase in the Nusselt number, whereas the micro-finned tube generally achieves higher PEC values due to lower hydraulic losses. The results clearly indicate that, in most cases, the PEC is higher for the finned tube, particularly at low Reynolds numbers not exceeding 50,000. In turn, for the insert, the longitudinal distance between the elements, L, has a significant influence on the PEC; as L increases, the PEC also increase, reaching its maximum value for the largest L.
- Open Access
- 3 December 2018
- Published by EDP Sciences
- Vol. 70, 03006
Technical problems with compression units in mechanical vapour recompression systems
The evidence gathered during works on two prototype heat recovery systems is summarised. The first installation is a low-temperature vapour recompression system, whereas the second is a high-temperature (from an industrial viewpoint) installation. Vapour-contaminated air is the working medium. The authors focused their attention on machine issues mainly. All compressors described below were designed at the Lodz University of Technology.
- 3 December 2018
- Published by EDP Sciences
- Vol. 70, 03006
Open AccessTechnical problems with compression units in mechanical vapour recompression systems
The evidence gathered during works on two prototype heat recovery systems is summarised. The first installation is a low-temperature vapour recompression system, whereas the second is a high-temperature (from an industrial viewpoint) installation. Vapour-contaminated air is the working medium. The authors focused their attention on machine issues mainly. All compressors described below were designed at the Lodz University of Technology.
- Open Access
- 1 June 2018
- Published by Walter de Gruyter GmbH in Mechanics and Mechanical Engineering
- Vol. 22 (2) , 455-464
Modernization of Centrifugal Chlorine Compressor
In this paper modernization of a three-stage chlorine centrifugal compressor, in which chlorine is pressurized has been described. Machine nominal mass flow has been increased by 20% and the pressure rise has remained almost unchanged. New construction concept has been chosen basing on analysis of different design variants. Calculations were conducted with one-dimensional method with usage of in-house developed code. Algorithms implemented to this program are based on empirical studies and wide experience in compressor modernization and design. Moreover, results of modified machine acceptance test results, which satisfies VDI norm 2045/ISO 5389 has been presented.
- 1 June 2018
- Published by Walter de Gruyter GmbH in Mechanics and Mechanical Engineering
- Vol. 22 (2) , 455-464
Open AccessModernization of Centrifugal Chlorine Compressor
In this paper modernization of a three-stage chlorine centrifugal compressor, in which chlorine is pressurized has been described. Machine nominal mass flow has been increased by 20% and the pressure rise has remained almost unchanged. New construction concept has been chosen basing on analysis of different design variants. Calculations were conducted with one-dimensional method with usage of in-house developed code. Algorithms implemented to this program are based on empirical studies and wide experience in compressor modernization and design. Moreover, results of modified machine acceptance test results, which satisfies VDI norm 2045/ISO 5389 has been presented.