Lukas Kiessner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lukas Kiessner has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Abdalrahman Sayed Herbawi
Microsystem Materials Laboratory, Department of Microsystems Engineering (IMTEK), University of Freiburg, D-79110 Freiburg im Breisgau, Germany, and also with the Cluster of Excellence BrainLinks-BrainTools, University of Freiburg, D-79110 Freiburg im Breisgau, Germany
1 shared publication - Olaf Christ
Department of Neurosurgery, Section of Neuroelectronic Systems, University Medical Center Freiburg, D-79108 Freiburg im Breisgau, Germany
1 shared publication - Oliver Paul
Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg, Germany
1 shared publication - Patrick Ruther
Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg, Germany
1 shared publication - Soheil Mottaghi
Neuroelectronic Systems, Department of Neurosurgery, Medical Center, University of Freiburg, Freiburg, Germany
1 shared publication - Ulrich G. Hofmann
University of Freiburg
1 shared publication
Latest Publications
- 19 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 27 (6) , 1023-1034
CMOS Neural Probe With 1600 Close-Packed Recording Sites and 32 Analog Output Channels
This paper reports on the development, characterization, and validation of neural probes serving the growing needs of neuroscience for miniaturized tools enabling simultaneous high-resolution recording of neural activity in multiple brain areas. The probes consist of a needle-shaped shaft with a cross-section of 100x 50,μm² and a length of 10 or 5 mm emerging from a base with dimensions of only 0.55x 1.8 mm². The shafts carry 1600 and 800 recording sites, respectively, grouped into 50 (respectively 25) blocks of 4x 8 electrodes with an area of 17x 17,μm² each, a pitch of 20 μm, and an electrode-to-electrode spacing of 3 μm. The probes are fabricated using a commercial 0.18 μm CMOS process followed by dedicated metallization, passivation, and microfabrication steps. Neural signals are accessible through 32 analog output channels via a hierarchical digital addressing scheme implementing an advanced electronic depth control concept giving the option of multiple scanning modes and offering a switching time of 416 μs at a clock frequency of 1 MHz. All output channels are shielded against each other, whereby crosstalk between neighboring channels is measured to be -58 dB at 1 kHz. Absolute impedance values at 1 kHz of single IrOₓ and Pt electrodes are 230± 38 kΩ and 2.2± 0.3 MΩ, respectively. In vivo recordings taking advantage of the new addressing concept for high-resolution recordings from multiple brain regions were successfully performed in anesthetized rats. [2018-0152]
- 19 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 27 (6) , 1023-1034
CMOS Neural Probe With 1600 Close-Packed Recording Sites and 32 Analog Output Channels
This paper reports on the development, characterization, and validation of neural probes serving the growing needs of neuroscience for miniaturized tools enabling simultaneous high-resolution recording of neural activity in multiple brain areas. The probes consist of a needle-shaped shaft with a cross-section of 100x 50,μm² and a length of 10 or 5 mm emerging from a base with dimensions of only 0.55x 1.8 mm². The shafts carry 1600 and 800 recording sites, respectively, grouped into 50 (respectively 25) blocks of 4x 8 electrodes with an area of 17x 17,μm² each, a pitch of 20 μm, and an electrode-to-electrode spacing of 3 μm. The probes are fabricated using a commercial 0.18 μm CMOS process followed by dedicated metallization, passivation, and microfabrication steps. Neural signals are accessible through 32 analog output channels via a hierarchical digital addressing scheme implementing an advanced electronic depth control concept giving the option of multiple scanning modes and offering a switching time of 416 μs at a clock frequency of 1 MHz. All output channels are shielded against each other, whereby crosstalk between neighboring channels is measured to be -58 dB at 1 kHz. Absolute impedance values at 1 kHz of single IrOₓ and Pt electrodes are 230± 38 kΩ and 2.2± 0.3 MΩ, respectively. In vivo recordings taking advantage of the new addressing concept for high-resolution recordings from multiple brain regions were successfully performed in anesthetized rats. [2018-0152]