Penghui Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Penghui Wang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Gance Dai
State Key Laboratory of Chemical Engineering East China University of Science and Technology Shanghai China
3 shared publications Gance Dai
2 shared publications- Liwei Zhuang
School of Chemical Engineering, East China University of Science and Technology, Shanghai, China
2 shared publications - Can Wang
China Three Gorges University
1 shared publication Hanfei Guo
1 shared publication- Weitong Pan
East China University of Science and Technology
1 shared publication
Latest Publications
- 21 December 2019
- Published by Wiley in AIChE Journal
- Vol. 66 (5)
A CFD‐based design scheme for the perforated distributor with the control of radial flow
In the present study, flow homogenization by distributors in chemical apparatus is studied as a process of flow control and its mechanism is reconsidered from the model of resistance to the model of radial flow. This process is composed of four consecutive behaviors: the generation, distribution, conversion of the radial flow and the momentum transfer of axial flow. Based on these flow behaviors, the novel distributor is designed as the combination of perforated plate in the center area and vertical guiding baffles around. Taking the wire‐screen catalytic reactor as a case study, numerical simulation is employed to optimize the structure of distributor and a CFD‐based design scheme called “flow field analysis scheme” is proposed. Numerical simulation is conducted in the apparatus with a diffuser (inlet D0 = 500 mm, main part D1 = 3,000 mm) under the gas velocity of 3.6 m/s (corresponding Re ≈ 12,000). The numerical results from optimized distributor show that compared with the traditional perforated plate, the flow field adjusted by the novel distributor can achieve a better flow uniformity with lower energy consumption. The theoretical analysis and numerical results are also validated and proved by the experimental results.
- 21 December 2019
- Published by Wiley in AIChE Journal
- Vol. 66 (5)
A CFD‐based design scheme for the perforated distributor with the control of radial flow
In the present study, flow homogenization by distributors in chemical apparatus is studied as a process of flow control and its mechanism is reconsidered from the model of resistance to the model of radial flow. This process is composed of four consecutive behaviors: the generation, distribution, conversion of the radial flow and the momentum transfer of axial flow. Based on these flow behaviors, the novel distributor is designed as the combination of perforated plate in the center area and vertical guiding baffles around. Taking the wire‐screen catalytic reactor as a case study, numerical simulation is employed to optimize the structure of distributor and a CFD‐based design scheme called “flow field analysis scheme” is proposed. Numerical simulation is conducted in the apparatus with a diffuser (inlet D0 = 500 mm, main part D1 = 3,000 mm) under the gas velocity of 3.6 m/s (corresponding Re ≈ 12,000). The numerical results from optimized distributor show that compared with the traditional perforated plate, the flow field adjusted by the novel distributor can achieve a better flow uniformity with lower energy consumption. The theoretical analysis and numerical results are also validated and proved by the experimental results.
- 6 November 2018
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 13 (6)
Synergistic effect between spraying layers on the performance of the WFGD spray column
In a WFGD spray column, spraying droplets have dual duties of optimizing flow uniformity and providing interfacial area for mass transfer but have contradiction in selection of diameter. In this paper, a synergistic effect between smaller and bigger droplets is proposed to improve the performance of the column, which is to enlarge the interfacial area and optimize the flow uniformity in different layers, and it is used to create a novel design scheme. Through the study of the flow uniformity in the spray column, the detail of this design scheme is proposed as followed: The minimum flow rate and proper droplet diameter should be selected in the bottom layer to achieve the flow uniformity, and smaller droplets can be used in the rest layer to enlarge the interfacial area as much as possible. Compared with the traditional scheme, the liquid hold‐up has increased 16%–30%, and the interfacial area has increased 32%–56% in novel scheme. In practice, this novel design scheme can provide reference and guidance for large scale spray columns.
- 6 November 2018
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 13 (6)
Synergistic effect between spraying layers on the performance of the WFGD spray column
In a WFGD spray column, spraying droplets have dual duties of optimizing flow uniformity and providing interfacial area for mass transfer but have contradiction in selection of diameter. In this paper, a synergistic effect between smaller and bigger droplets is proposed to improve the performance of the column, which is to enlarge the interfacial area and optimize the flow uniformity in different layers, and it is used to create a novel design scheme. Through the study of the flow uniformity in the spray column, the detail of this design scheme is proposed as followed: The minimum flow rate and proper droplet diameter should be selected in the bottom layer to achieve the flow uniformity, and smaller droplets can be used in the rest layer to enlarge the interfacial area as much as possible. Compared with the traditional scheme, the liquid hold‐up has increased 16%–30%, and the interfacial area has increased 32%–56% in novel scheme. In practice, this novel design scheme can provide reference and guidance for large scale spray columns.
- 3 September 2018
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 57 (37) , 12531-12542
Field Synergy of the Rod Bank on the Enhancement of Mass Transfer in a Spray Column
- 3 September 2018
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 57 (37) , 12531-12542
Field Synergy of the Rod Bank on the Enhancement of Mass Transfer in a Spray Column
- 1 April 2017
- Published by Elsevier in Chemical Engineering Science
- Vol. 162, 227-244
Synergistic effect of droplet self-adjustment and rod bank internal on fluid distribution in a WFGD spray column
- 1 April 2017
- Published by Elsevier in Chemical Engineering Science
- Vol. 162, 227-244
Synergistic effect of droplet self-adjustment and rod bank internal on fluid distribution in a WFGD spray column
- 1 May 2016
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 77, 19-24
Synthetic fault factor features under Weibull stochastic interference
- 1 May 2016
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 77, 19-24
Synthetic fault factor features under Weibull stochastic interference
- 1 December 2015
- Published by Elsevier in Journal of Membrane Science
- Vol. 495, 372-383
Study on the flux distribution in a dead-end outside-in hollow fiber membrane module
- 1 December 2015
- Published by Elsevier in Journal of Membrane Science
- Vol. 495, 372-383
Study on the flux distribution in a dead-end outside-in hollow fiber membrane module