Ian Galton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ian Galton has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Amr I. Eissa
Electrical and Computer Engineering Department, University of California at San Diego, La Jolla, CA, USA
5 shared publications - Enrique Alvarez-Fontecilla
Analog Devices Inc., Santiago, Chile
5 shared publications - Eslam Helal
Department of Electrical and Computer Engineering, University of California at San Diego, La Jolla, CA, USA
4 shared publications Colin Weltin-Wu
Aeonsemi, Inc., Santa Clara, CA, USA
3 shared publications- Derui Kong
Electrical and Computer Engineering Department, University of California at San Diego, La Jolla, CA 92093-0407 USA
3 shared publications - Shadi. A. Dayeh
Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, California 92093, USA
3 shared publications
Latest Publications
- 17 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 72  (9) , 4539-4549
Enhanced ISI Analysis and Fast Circuit Simulation of High-Speed Current-Steering DACs
High-linearity current-steering DACs are critical components in wireless and wireline communication systems, but are notoriously time-consuming to design. Nonlinearity from component mismatches and clock skew can be mitigated with DEM and calibration, but the remaining sources of nonlinearity must be managed by painstaking analog design iteration. Typically, exceedingly long circuit simulations, e.g., each on the order of many days, are required to guide the iteration process, which makes for long design cycles. This paper presents an enhanced analysis of DAC error from component mismatches, clock skew, and inter-symbol interference, and applies the results to enable a new circuit-level simulation technique to quantify nonlinearity that is significantly faster than conventional techniques without sacrificing accuracy. It demonstrates via analysis and simulation examples that the technique enables over an order of magnitude speed increase of circuit-level simulations of high-linearity, high-speed, current-steering DACs.
- 17 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 72  (9) , 4539-4549
Enhanced ISI Analysis and Fast Circuit Simulation of High-Speed Current-Steering DACs
High-linearity current-steering DACs are critical components in wireless and wireline communication systems, but are notoriously time-consuming to design. Nonlinearity from component mismatches and clock skew can be mitigated with DEM and calibration, but the remaining sources of nonlinearity must be managed by painstaking analog design iteration. Typically, exceedingly long circuit simulations, e.g., each on the order of many days, are required to guide the iteration process, which makes for long design cycles. This paper presents an enhanced analysis of DAC error from component mismatches, clock skew, and inter-symbol interference, and applies the results to enable a new circuit-level simulation technique to quantify nonlinearity that is significantly faster than conventional techniques without sacrificing accuracy. It demonstrates via analysis and simulation examples that the technique enables over an order of magnitude speed increase of circuit-level simulations of high-linearity, high-speed, current-steering DACs.
- 18 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60  (3) , 894-907
A 2.5–20 kS/s In-Pixel Direct Digitization ECoG Front End With Submillisecond Stimulation Artifact Recovery
Neural stimulation is used routinely to diagnose and treat neurological disorders. The stimulation artifacts are, however, problematic for closed-loop neuromodulation therapy, which dynamically adjusts the electrical stimulation parameters based on real-time feedback from the recorded neural activity because they can cause saturation or prolonged recovery times in traditional recording front ends. This article presents a per-pixel second-order$\Delta \Sigma $ analog-to-digital converter (ADC) for direct digitization of neural signals, which addresses the stimulation artifact recovery time in voltage-controlled oscillator (VCO)-based quantizers with a fast-recovery, overrange-detecting phase quantizer. The ADC uses a pseudo-virtual ground feedforwarding (PVG FF) technique and a complementary input${G} _{\text {m}}$ -C filter with per-pixel decimation. It supports four recording modes covering 2.5–20 kS/s through a power-efficient, bandwidth-scalable continuous time$\Delta \Sigma $ modulator. Fabricated in a 180-nm CMOS process, this$300\times 300~\mu $ m2 ADC achieves$\gt 250\times $ faster (0.05–0.4 ms) stimulation artifact recovery time, enabling in-stimulation recording. Recording with artifact tolerance was demonstrated through an in vivo whisker barrel rat experiment.- 18 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60  (3) , 894-907
A 2.5–20 kS/s In-Pixel Direct Digitization ECoG Front End With Submillisecond Stimulation Artifact Recovery
Neural stimulation is used routinely to diagnose and treat neurological disorders. The stimulation artifacts are, however, problematic for closed-loop neuromodulation therapy, which dynamically adjusts the electrical stimulation parameters based on real-time feedback from the recorded neural activity because they can cause saturation or prolonged recovery times in traditional recording front ends. This article presents a per-pixel second-order$\Delta \Sigma $ analog-to-digital converter (ADC) for direct digitization of neural signals, which addresses the stimulation artifact recovery time in voltage-controlled oscillator (VCO)-based quantizers with a fast-recovery, overrange-detecting phase quantizer. The ADC uses a pseudo-virtual ground feedforwarding (PVG FF) technique and a complementary input${G} _{\text {m}}$ -C filter with per-pixel decimation. It supports four recording modes covering 2.5–20 kS/s through a power-efficient, bandwidth-scalable continuous time$\Delta \Sigma $ modulator. Fabricated in a 180-nm CMOS process, this$300\times 300~\mu $ m2 ADC achieves$\gt 250\times $ faster (0.05–0.4 ms) stimulation artifact recovery time, enabling in-stimulation recording. Recording with artifact tolerance was demonstrated through an in vivo whisker barrel rat experiment.- 28 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 71  (10) , 4524-4537
A Duty-Cycle-Error-Immune Reference Frequency Doubling Technique for Fractional-N Digital PLLs
Increasing a PLL’s reference frequency offers significant performance advantages, but doing so by increasing the PLL’s crystal oscillator frequency is not a viable option in many applications. Instead, a frequency doubler can be used to derive a reference signal with twice the frequency of the crystal oscillator, but conventional PLLs are highly sensitive to the crystal oscillator’s duty cycle error in such cases. Prior solutions to this problem involve calibration techniques which impose convergence speed versus accuracy tradeoffs. In contrast, this paper proposes a system modification which makes a PLL immune to such duty cycle errors without the need for calibration. The technique is presented and analyzed in the context of a delta-sigma frequency-to-digital converter ( $\Delta \Sigma $ -FDC) based PLL. Analysis and behavioral simulations with nonideal circuit parameters show that the worst-case convergence time is at least 10 times faster than that of the prior techniques. Additionally, the proposed $\Delta \Sigma $ -FDC includes other modifications which improve its performance relative to comparable prior $\Delta \Sigma $ -FDCs.
- 28 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 71  (10) , 4524-4537
A Duty-Cycle-Error-Immune Reference Frequency Doubling Technique for Fractional-N Digital PLLs
Increasing a PLL’s reference frequency offers significant performance advantages, but doing so by increasing the PLL’s crystal oscillator frequency is not a viable option in many applications. Instead, a frequency doubler can be used to derive a reference signal with twice the frequency of the crystal oscillator, but conventional PLLs are highly sensitive to the crystal oscillator’s duty cycle error in such cases. Prior solutions to this problem involve calibration techniques which impose convergence speed versus accuracy tradeoffs. In contrast, this paper proposes a system modification which makes a PLL immune to such duty cycle errors without the need for calibration. The technique is presented and analyzed in the context of a delta-sigma frequency-to-digital converter ( $\Delta \Sigma $ -FDC) based PLL. Analysis and behavioral simulations with nonideal circuit parameters show that the worst-case convergence time is at least 10 times faster than that of the prior techniques. Additionally, the proposed $\Delta \Sigma $ -FDC includes other modifications which improve its performance relative to comparable prior $\Delta \Sigma $ -FDCs.
- 24 April 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 16  (744) , eadj7257
An electroencephalogram microdisplay to visualize neuronal activity on the brain surface
Functional mapping during brain surgery is applied to define brain areas that control critical functions and cannot be removed. Currently, these procedures rely on verbal interactions between the neurosurgeon and electrophysiologist, which can be time-consuming. In addition, the electrode grids that are used to measure brain activity and to identify the boundaries of pathological versus functional brain regions have low resolution and limited conformity to the brain surface. Here, we present the development of an intracranial electroencephalogram (iEEG)–microdisplay that consists of freestanding arrays of 2048 GaN light-emitting diodes laminated on the back of micro-electrocorticography electrode grids. With a series of proof-of-concept experiments in rats and pigs, we demonstrate that these iEEG-microdisplays allowed us to perform real-time iEEG recordings and display cortical activities by spatially corresponding light patterns on the surface of the brain in the surgical field. Furthermore, iEEG-microdisplays allowed us to identify and display cortical landmarks and pathological activities from rat and pig models. Using a dual-color iEEG-microdisplay, we demonstrated coregistration of the functional cortical boundaries with one color and displayed the evolution of electrical potentials associated with epileptiform activity with another color. The iEEG-microdisplay holds promise to facilitate monitoring of pathological brain activity in clinical settings.
- 24 April 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 16  (744) , eadj7257
An electroencephalogram microdisplay to visualize neuronal activity on the brain surface
Functional mapping during brain surgery is applied to define brain areas that control critical functions and cannot be removed. Currently, these procedures rely on verbal interactions between the neurosurgeon and electrophysiologist, which can be time-consuming. In addition, the electrode grids that are used to measure brain activity and to identify the boundaries of pathological versus functional brain regions have low resolution and limited conformity to the brain surface. Here, we present the development of an intracranial electroencephalogram (iEEG)–microdisplay that consists of freestanding arrays of 2048 GaN light-emitting diodes laminated on the back of micro-electrocorticography electrode grids. With a series of proof-of-concept experiments in rats and pigs, we demonstrate that these iEEG-microdisplays allowed us to perform real-time iEEG recordings and display cortical activities by spatially corresponding light patterns on the surface of the brain in the surgical field. Furthermore, iEEG-microdisplays allowed us to identify and display cortical landmarks and pathological activities from rat and pig models. Using a dual-color iEEG-microdisplay, we demonstrated coregistration of the functional cortical boundaries with one color and displayed the evolution of electrical potentials associated with epileptiform activity with another color. The iEEG-microdisplay holds promise to facilitate monitoring of pathological brain activity in clinical settings.
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 70  (11) , 4309-4322
Adaptive Cancellation of Inter-Symbol Interference in High-Speed Continuous-Time DACs
Inter-symbol interference (ISI) often limits the performance of high-speed continuous-time digital-to-analog converters (DACs) such as Nyquist-rate current-steering DACs. The most effective previously-published means of mitigating ISI is return-to-zero (RZ) pulse shaping. Unfortunately, such RZ DACs are significantly more sensitive to clock jitter than their non-return-to-zero (NRZ) counterparts, particularly at high clock rates, and they typically consume more than twice the power of comparable NRZ DACs. This paper proposes, demonstrates via simulation, and rigorously analyzes a calibration technique which circumvents the need for RZ pulse shaping by adaptively measuring and cancelling ISI over the DAC’s first Nyquist band. It can be operated in both foreground and background calibration modes, and is compatible and can share circuitry with a recently-published calibration technique that similarly cancels error from component mismatches and clock skew.
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 70  (11) , 4309-4322
Adaptive Cancellation of Inter-Symbol Interference in High-Speed Continuous-Time DACs
Inter-symbol interference (ISI) often limits the performance of high-speed continuous-time digital-to-analog converters (DACs) such as Nyquist-rate current-steering DACs. The most effective previously-published means of mitigating ISI is return-to-zero (RZ) pulse shaping. Unfortunately, such RZ DACs are significantly more sensitive to clock jitter than their non-return-to-zero (NRZ) counterparts, particularly at high clock rates, and they typically consume more than twice the power of comparable NRZ DACs. This paper proposes, demonstrates via simulation, and rigorously analyzes a calibration technique which circumvents the need for RZ pulse shaping by adaptively measuring and cancelling ISI over the DAC’s first Nyquist band. It can be operated in both foreground and background calibration modes, and is compatible and can share circuitry with a recently-published calibration technique that similarly cancels error from component mismatches and clock skew.
- 15 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 69  (12) , 4993-5006
DTC Linearization via Mismatch-Noise Cancellation for Digital Fractional-N PLLs
Digital-to-time converter (DTC) based quantization noise cancellation (QNC) has recently been shown to enable excellent fractional- $N$ PLL performance, but it requires a highly-linear DTC. Known DTC linearization strategies include analog-domain techniques which involve performance tradeoffs and digital predistortion techniques which converge slowly relative to typical required PLL settling times. Alternatively, a DTC implemented as a cascade of 1-bit DTC stages can be made highly linear without special techniques, but such DTCs typically introduce excessive error from component mismatches which has so far hindered their use in low-jitter PLLs. This paper presents a background calibration technique that addresses this issue by adaptively canceling error from DTC component mismatches. The technique is entirely digital, is compatible with a large class of digital fractional- $N$ PLLs, and has at least an order of magnitude lower convergence time than the above-mentioned predistortion techniques. The paper presents a rigorous theoretical analysis closely supported by simulation results which quantifies the calibration technique’s convergence time and noise performance.
- 15 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 69  (12) , 4993-5006
DTC Linearization via Mismatch-Noise Cancellation for Digital Fractional-N PLLs
Digital-to-time converter (DTC) based quantization noise cancellation (QNC) has recently been shown to enable excellent fractional- $N$ PLL performance, but it requires a highly-linear DTC. Known DTC linearization strategies include analog-domain techniques which involve performance tradeoffs and digital predistortion techniques which converge slowly relative to typical required PLL settling times. Alternatively, a DTC implemented as a cascade of 1-bit DTC stages can be made highly linear without special techniques, but such DTCs typically introduce excessive error from component mismatches which has so far hindered their use in low-jitter PLLs. This paper presents a background calibration technique that addresses this issue by adaptively canceling error from DTC component mismatches. The technique is entirely digital, is compatible with a large class of digital fractional- $N$ PLLs, and has at least an order of magnitude lower convergence time than the above-mentioned predistortion techniques. The paper presents a rigorous theoretical analysis closely supported by simulation results which quantifies the calibration technique’s convergence time and noise performance.
- Top Cited Papers
- 19 January 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 14  (628) , eabj1441
Human brain mapping with multithousand-channel PtNRGrids resolves spatiotemporal dynamics
Electrophysiological devices are critical for mapping eloquent and diseased brain regions and for therapeutic neuromodulation in clinical settings and are extensively used for research in brain-machine interfaces. However, the existing clinical and experimental devices are often limited in either spatial resolution or cortical coverage. Here, we developed scalable manufacturing processes with a dense electrical connection scheme to achieve reconfigurable thin-film, multithousand-channel neurophysiological recording grids using platinum nanorods (PtNRGrids). With PtNRGrids, we have achieved a multithousand-channel array of small (30 μm) contacts with low impedance, providing high spatial and temporal resolution over a large cortical area. We demonstrated that PtNRGrids can resolve submillimeter functional organization of the barrel cortex in anesthetized rats that captured the tissue structure. In the clinical setting, PtNRGrids resolved fine, complex temporal dynamics from the cortical surface in an awake human patient performing grasping tasks. In addition, the PtNRGrids identified the spatial spread and dynamics of epileptic discharges in a patient undergoing epilepsy surgery at 1-mm spatial resolution, including activity induced by direct electrical stimulation. Collectively, these findings demonstrated the power of the PtNRGrids to transform clinical mapping and research with brain-machine interfaces.
- 19 January 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 14  (628) , eabj1441
Top Cited PapersHuman brain mapping with multithousand-channel PtNRGrids resolves spatiotemporal dynamics
Electrophysiological devices are critical for mapping eloquent and diseased brain regions and for therapeutic neuromodulation in clinical settings and are extensively used for research in brain-machine interfaces. However, the existing clinical and experimental devices are often limited in either spatial resolution or cortical coverage. Here, we developed scalable manufacturing processes with a dense electrical connection scheme to achieve reconfigurable thin-film, multithousand-channel neurophysiological recording grids using platinum nanorods (PtNRGrids). With PtNRGrids, we have achieved a multithousand-channel array of small (30 μm) contacts with low impedance, providing high spatial and temporal resolution over a large cortical area. We demonstrated that PtNRGrids can resolve submillimeter functional organization of the barrel cortex in anesthetized rats that captured the tissue structure. In the clinical setting, PtNRGrids resolved fine, complex temporal dynamics from the cortical surface in an awake human patient performing grasping tasks. In addition, the PtNRGrids identified the spatial spread and dynamics of epileptic discharges in a patient undergoing epilepsy surgery at 1-mm spatial resolution, including activity induced by direct electrical stimulation. Collectively, these findings demonstrated the power of the PtNRGrids to transform clinical mapping and research with brain-machine interfaces.
- 15 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57  (2) , 465-479
An ISI Scrambling Technique for Dynamic Element Matching Current-Steering DACs
The linearity of high-resolution current-steering digital-to-analog converters (DACs) is often limited by inter-symbol interference (ISI). While dynamic element matching (DEM) can be applied to convert a portion of the ISI to uncorrelated noise instead of nonlinear distortion, DEM alone fails to prevent ISI from at least introducing strong second-order nonlinear distortion. This paper addresses this problem by proposing, analyzing, and experimentally demonstrating a low-cost add-on technique, called ISI scrambling, that, in conjunction with DEM, causes a DAC’s ISI to be free of nonlinear distortion. The ISI scrambling technique is demonstrated in a 1-GS/s, 14-bit DEM DAC implemented in 90 nm CMOS technology. The DAC’s measured linearity is in line with the state-of-the-art and its measured output power spectra closely match those predicted by this paper’s theoretical results.
- 15 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57  (2) , 465-479
An ISI Scrambling Technique for Dynamic Element Matching Current-Steering DACs
The linearity of high-resolution current-steering digital-to-analog converters (DACs) is often limited by inter-symbol interference (ISI). While dynamic element matching (DEM) can be applied to convert a portion of the ISI to uncorrelated noise instead of nonlinear distortion, DEM alone fails to prevent ISI from at least introducing strong second-order nonlinear distortion. This paper addresses this problem by proposing, analyzing, and experimentally demonstrating a low-cost add-on technique, called ISI scrambling, that, in conjunction with DEM, causes a DAC’s ISI to be free of nonlinear distortion. The ISI scrambling technique is demonstrated in a 1-GS/s, 14-bit DEM DAC implemented in 90 nm CMOS technology. The DAC’s measured linearity is in line with the state-of-the-art and its measured output power spectra closely match those predicted by this paper’s theoretical results.
- Open Access
- 12 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56  (10) , 3191-3201
Spectral Breathing and Its Mitigation in Digital Fractional-N PLLs
Although digital phase-locked loops (PLLs) offer several advantages over their analog counterparts, they suffer from a major disadvantage that is rarely mentioned in published articles. The disadvantage, known as spectral breathing, is caused by component mismatches among the frequency control elements within a PLL’s digitally controlled oscillator (DCO). The mismatches introduce DCO frequency modulation nonlinearity which fluctuates and, therefore, causes erratic variations in the PLL’s measured phase noise spectrum as the DCO’s free-running frequency drifts. The phenomenon is called spectral breathing because the measured phase noise spectrum tends to slowly swell and contract over time as if taking breaths of air. During these breaths, the PLL’s phase noise often becomes severely degraded. This article presents an experimental demonstration of the spectral breathing phenomenon and its solution in a digital fractional- $N$ PLL. The demonstrated solution is a multi-rate dynamic element matching technique and a mismatch-noise cancellation technique that together eliminate spectral breathing.
- 12 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56  (10) , 3191-3201
Open AccessSpectral Breathing and Its Mitigation in Digital Fractional-N PLLs
Although digital phase-locked loops (PLLs) offer several advantages over their analog counterparts, they suffer from a major disadvantage that is rarely mentioned in published articles. The disadvantage, known as spectral breathing, is caused by component mismatches among the frequency control elements within a PLL’s digitally controlled oscillator (DCO). The mismatches introduce DCO frequency modulation nonlinearity which fluctuates and, therefore, causes erratic variations in the PLL’s measured phase noise spectrum as the DCO’s free-running frequency drifts. The phenomenon is called spectral breathing because the measured phase noise spectrum tends to slowly swell and contract over time as if taking breaths of air. During these breaths, the PLL’s phase noise often becomes severely degraded. This article presents an experimental demonstration of the spectral breathing phenomenon and its solution in a digital fractional- $N$ PLL. The demonstrated solution is a multi-rate dynamic element matching technique and a mismatch-noise cancellation technique that together eliminate spectral breathing.
- 2 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56  (9) , 2711-2723
A Time Amplifier Assisted Frequency-to-Digital Converter Based Digital Fractional-N PLL
This article presents a wide input-range delay chain based time amplifier (TA) and its application to a 6.5-GHz digital fractional- N phase-locked loop (PLL). The TA includes a delay-averaging linearity enhancement technique and the PLL is based on an improved dual-mode ring oscillator (DMRO) delta-sigma (ΔΣ) frequency-to-digital converter (FDC). The TA mitigates contributions to the PLL's phase noise from DMRO flicker noise, which would otherwise degrade the PLL's in-band phase noise, and from ΔΣ FDC quantization error, which would otherwise degrade the PLL's phase noise at high bandwidth settings. This paper also presents a delay-free asynchronous DMRO phase sampling scheme, and the first experimental demonstration of a recently-proposed ΔΣ FDC digital gain calibration technique. The TA-assisted PLL achieves a random jitter of 145 fs rms , a total jitter that ranges from 151 to 270 fs rms as a result of fractional spurs, and a worst-case fractional spur of -49 dBc without requiring nonlinearity calibration.
- 2 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56  (9) , 2711-2723
A Time Amplifier Assisted Frequency-to-Digital Converter Based Digital Fractional-N PLL
This article presents a wide input-range delay chain based time amplifier (TA) and its application to a 6.5-GHz digital fractional- N phase-locked loop (PLL). The TA includes a delay-averaging linearity enhancement technique and the PLL is based on an improved dual-mode ring oscillator (DMRO) delta-sigma (ΔΣ) frequency-to-digital converter (FDC). The TA mitigates contributions to the PLL's phase noise from DMRO flicker noise, which would otherwise degrade the PLL's in-band phase noise, and from ΔΣ FDC quantization error, which would otherwise degrade the PLL's phase noise at high bandwidth settings. This paper also presents a delay-free asynchronous DMRO phase sampling scheme, and the first experimental demonstration of a recently-proposed ΔΣ FDC digital gain calibration technique. The TA-assisted PLL achieves a random jitter of 145 fs rms , a total jitter that ranges from 151 to 270 fs rms as a result of fractional spurs, and a worst-case fractional spur of -49 dBc without requiring nonlinearity calibration.