Janne Askola
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Janne Askola has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Erkki Ikonen
Metrology Research Institute, Aalto University, Espoo, Finland
6 shared publicationsE Ikonen
Metrology Research Institute, Aalto University, Espoo, Finland
4 shared publications- Petri Kärhä
Metrology Research Institute, Aalto University, Espoo, Finland
4 shared publications - Tomi Pulli
Metrology Research Institute, Aalto University, Espoo, Finland
3 shared publications Tuomas Poikonen
MIKES Metrology, VTT Technical Research Centre of Finland Ltd, Espoo, Finland
3 shared publications- Alexander Kokka
Metrology Research Institute, Aalto University, Espoo, Finland
2 shared publications
Latest Publications
- Open Access
- 21 October 2024
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 56 (7) , 790-799
Improvement of temporal light artefact effects in commercial LED lamps
Temporal light modulation and its potential adverse visual effects on human observers, collectively known as temporal light artefacts (TLAs), have been limited by the European Union Ecodesign regulation. Limitations on two key TLA metrics, flicker and stroboscopic effect, were introduced in September 2021. This study analyses the impact of this regulation on commercial LED lamps by measuring multiple different consumer-grade LED E27 retrofit lamps by several manufacturers before and after the regulation. The lamps purchased after the Ecodesign regulation seem to favour a certain type of LED driver that provides the best TLA behaviour of all lamp types. The regulation, with respect to TLA, has resulted in the replacement of ill-behaving lamp types in the market by newer lamps with better TLA characteristics.
- 21 October 2024
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 56 (7) , 790-799
Open AccessImprovement of temporal light artefact effects in commercial LED lamps
Temporal light modulation and its potential adverse visual effects on human observers, collectively known as temporal light artefacts (TLAs), have been limited by the European Union Ecodesign regulation. Limitations on two key TLA metrics, flicker and stroboscopic effect, were introduced in September 2021. This study analyses the impact of this regulation on commercial LED lamps by measuring multiple different consumer-grade LED E27 retrofit lamps by several manufacturers before and after the regulation. The lamps purchased after the Ecodesign regulation seem to favour a certain type of LED driver that provides the best TLA behaviour of all lamp types. The regulation, with respect to TLA, has resulted in the replacement of ill-behaving lamp types in the market by newer lamps with better TLA characteristics.
- Open Access
- 29 November 2023
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 56 (7) , 734-743
Digital implementations for determination of temporal light artefacts of LED luminaires
Flicker and stroboscopic effects caused by a temporally modulated light source may be harmful for the human visual system. Standardized measurement methods have been developed for the related temporal light artefacts of LED luminaires. It was found out that the performance of the International Electrotechnical Commission (IEC) recommended flickermeter implementation is highly dependent on sampling frequency. Novel digital implementations for the flickermeter and stroboscopic effect visibility measure (SVM) were created to remove any inaccuracies. The performance of the novel Aalto implementations does not depend on the sampling frequency when running the test waveforms of the IEC standard through the implementations. As compared with the IEC recommended digital implementations, Aalto flickermeter decreases the average error related to the test waveforms from −0.05 to +0.003, and Aalto SVM meter also decreases the average error by almost two orders of magnitude.
- 29 November 2023
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 56 (7) , 734-743
Open AccessDigital implementations for determination of temporal light artefacts of LED luminaires
Flicker and stroboscopic effects caused by a temporally modulated light source may be harmful for the human visual system. Standardized measurement methods have been developed for the related temporal light artefacts of LED luminaires. It was found out that the performance of the International Electrotechnical Commission (IEC) recommended flickermeter implementation is highly dependent on sampling frequency. Novel digital implementations for the flickermeter and stroboscopic effect visibility measure (SVM) were created to remove any inaccuracies. The performance of the novel Aalto implementations does not depend on the sampling frequency when running the test waveforms of the IEC standard through the implementations. As compared with the IEC recommended digital implementations, Aalto flickermeter decreases the average error related to the test waveforms from −0.05 to +0.003, and Aalto SVM meter also decreases the average error by almost two orders of magnitude.
- Open Access
- 24 June 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (5) , 055008
Increased detector response in optical overfilled measurements due to gas lens formation by nitrogen flow through the entrance aperture
According to our experimental results, a nitrogen flow used to prevent dust and moisture entering a detector may influence measurements performed with trap detectors in overfilled conditions. A stable light source was measured with a wedged trap detector with 4 mm aperture, and the nitrogen flow rate was varied. The nitrogen flow was found to have the largest effect of up to 0.8% on the responsivity of the detector at around 1.0 l min−1 flow rate. The effect of nitrogen flow can be removed down to 0.02% by an added crossflow which removes the nitrogen out of the optical axis. In another experiment, the effect was removed almost completely by changing the flowing gas from nitrogen to synthetic dry air. We also present measurement results that indicate the responsivity changes with nitrogen to be smaller than 0.05% with underfilled beam geometry, even without the added crossflow. Based on simulations, the nitrogen flow through the detector forms a gradient-index type gas lens in front of the detector increasing the effective aperture area and thus the responsivity. In the underfilled measurement geometry there is no light close to the aperture edge which could be refracted inside the detector. Finally, we consider methods to ensure that the responsivity changes due to the gas flow remain below 0.05% in overfilled measurement geometry, without compromising the cleanliness of the detector with too small gas flow rate.
- 24 June 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (5) , 055008
Open AccessIncreased detector response in optical overfilled measurements due to gas lens formation by nitrogen flow through the entrance aperture
According to our experimental results, a nitrogen flow used to prevent dust and moisture entering a detector may influence measurements performed with trap detectors in overfilled conditions. A stable light source was measured with a wedged trap detector with 4 mm aperture, and the nitrogen flow rate was varied. The nitrogen flow was found to have the largest effect of up to 0.8% on the responsivity of the detector at around 1.0 l min−1 flow rate. The effect of nitrogen flow can be removed down to 0.02% by an added crossflow which removes the nitrogen out of the optical axis. In another experiment, the effect was removed almost completely by changing the flowing gas from nitrogen to synthetic dry air. We also present measurement results that indicate the responsivity changes with nitrogen to be smaller than 0.05% with underfilled beam geometry, even without the added crossflow. Based on simulations, the nitrogen flow through the detector forms a gradient-index type gas lens in front of the detector increasing the effective aperture area and thus the responsivity. In the underfilled measurement geometry there is no light close to the aperture edge which could be refracted inside the detector. Finally, we consider methods to ensure that the responsivity changes due to the gas flow remain below 0.05% in overfilled measurement geometry, without compromising the cleanliness of the detector with too small gas flow rate.
- Open Access
- 3 May 2021
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 54 (1) , 75-89
Effect of adaptive control on the LED street luminaire lifetime and on the lifecycle costs of a lighting installation
We report for the first time the effect of ageing due to adaptive control of lighting on the lifecycle costs of luminaire installations. Two types of LED street luminaire were aged (1) as the luminaire lit for 9 hours and then switched off for 3 hours and (2) under intensive ageing using adaptive control conditions mimicking presence of vehicles, where the luminaires were switched with 30-second interval between 100% and 20% power within the cycle of (1). The test continued for 32,000 hours. Luminaire lifetime was found to decrease by 10% due to the intensive adaptive control, which exaggerates the ageing as compared to real traffic conditions. We estimate that a realistic rate of dimming cycles would decrease the luminaire lifetime by 0–2%, increasing the lifecycle costs of a lighting installation by 0–0.7%. With a traffic-aware control system, capable of 50% energy saving in lighting, the lifecycle costs are estimated to reduce by 25% as compared to a similar LED luminaire installation without traffic-aware control, outweighing the costs due to the reduced lifetime. The smart controlling of lighting is considered as a useful way to meet future energy saving targets.
- 3 May 2021
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 54 (1) , 75-89
Open AccessEffect of adaptive control on the LED street luminaire lifetime and on the lifecycle costs of a lighting installation
We report for the first time the effect of ageing due to adaptive control of lighting on the lifecycle costs of luminaire installations. Two types of LED street luminaire were aged (1) as the luminaire lit for 9 hours and then switched off for 3 hours and (2) under intensive ageing using adaptive control conditions mimicking presence of vehicles, where the luminaires were switched with 30-second interval between 100% and 20% power within the cycle of (1). The test continued for 32,000 hours. Luminaire lifetime was found to decrease by 10% due to the intensive adaptive control, which exaggerates the ageing as compared to real traffic conditions. We estimate that a realistic rate of dimming cycles would decrease the luminaire lifetime by 0–2%, increasing the lifecycle costs of a lighting installation by 0–0.7%. With a traffic-aware control system, capable of 50% energy saving in lighting, the lifecycle costs are estimated to reduce by 25% as compared to a similar LED luminaire installation without traffic-aware control, outweighing the costs due to the reduced lifetime. The smart controlling of lighting is considered as a useful way to meet future energy saving targets.
- Open Access
- 1 October 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 352 (1) , 012043
Influence of smart lighting control on the lifetime of high power LED luminaires
LED lighting and smart controlling can decrease the consumption of electric power in zero or positive energy buildings. This study demonstrates that cyclic dimming, which appears in smart controlling, e.g. through occupancy sensing, might have an effect on the luminaire lifetimes and failure rates. Two different types of LED luminaires were aged in 30-s cycled dimming and undimmed modes. The manufacturer-specified lifetimes for both luminaire types were 100 000 hours. For one of the luminaire types, four out of five cycled units failed before 30 000 operating hours. For the uncycled luminaires, the lifetimes estimated from the measurements were over 100 000 hours. For the other type, the estimated lifetimes were 75 000 hours and 64 000 hours for uncycled and cycled luminaires, respectively.
- 1 October 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 352 (1) , 012043
Open AccessInfluence of smart lighting control on the lifetime of high power LED luminaires
LED lighting and smart controlling can decrease the consumption of electric power in zero or positive energy buildings. This study demonstrates that cyclic dimming, which appears in smart controlling, e.g. through occupancy sensing, might have an effect on the luminaire lifetimes and failure rates. Two different types of LED luminaires were aged in 30-s cycled dimming and undimmed modes. The manufacturer-specified lifetimes for both luminaire types were 100 000 hours. For one of the luminaire types, four out of five cycled units failed before 30 000 operating hours. For the uncycled luminaires, the lifetimes estimated from the measurements were over 100 000 hours. For the other type, the estimated lifetimes were 75 000 hours and 64 000 hours for uncycled and cycled luminaires, respectively.
- 18 December 2018
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 51 (8) , 1263-1274
Accelerated ageing of organic LED panels using ultraviolet exposure
Two different types of commercial organic LED panels were aged with ultraviolet light. One type was aged in an over-filled and open circuit condition with broadband ultraviolet radiation, and the other in an under-filled and closed circuit condition with spectrally dispersed light. Both the luminance values and the spectral power distributions of the panels were measured for both types. The results show that the light output and the spectrum of the panel decay faster when the panels are exposed to ultraviolet radiation when compared to natural ageing. For the panels aged using the under-filled method, the wavelength that reduces the output most is between 320 nm and 340 nm, and the ultraviolet exposure with wavelengths longer than 350 nm did not accelerate the ageing. The ultraviolet radiation exposure increased the ageing by a factor of eight as compared to natural ageing, when the used ultraviolet levels corresponded to one year of exposure on a clear summer day condition. Based on the results, the under-filled method is a valid option for accelerated ageing, especially for studying simultaneously accelerated and natural ageing.
- 18 December 2018
- Published by SAGE Publications in Lighting Research & Technology
- Vol. 51 (8) , 1263-1274
Accelerated ageing of organic LED panels using ultraviolet exposure
Two different types of commercial organic LED panels were aged with ultraviolet light. One type was aged in an over-filled and open circuit condition with broadband ultraviolet radiation, and the other in an under-filled and closed circuit condition with spectrally dispersed light. Both the luminance values and the spectral power distributions of the panels were measured for both types. The results show that the light output and the spectrum of the panel decay faster when the panels are exposed to ultraviolet radiation when compared to natural ageing. For the panels aged using the under-filled method, the wavelength that reduces the output most is between 320 nm and 340 nm, and the ultraviolet exposure with wavelengths longer than 350 nm did not accelerate the ageing. The ultraviolet radiation exposure increased the ageing by a factor of eight as compared to natural ageing, when the used ultraviolet levels corresponded to one year of exposure on a clear summer day condition. Based on the results, the under-filled method is a valid option for accelerated ageing, especially for studying simultaneously accelerated and natural ageing.
- Open Access
- 24 July 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (4) , 577-583
Fisheye camera method for spatial non-uniformity corrections in luminous flux measurements with integrating spheres
- 24 July 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (4) , 577-583
Open AccessFisheye camera method for spatial non-uniformity corrections in luminous flux measurements with integrating spheres
- 6 April 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (11) , 3077-3086
Nonlinearity characterization of array spectroradiometers for the solar UV measurements
Array spectroradiometers are attractive alternatives to scanning spectroradiometers in solar ultraviolet measurements. However, the measurement of solar spectral irradiance imposes stringent requirements for the linearity of the instruments. In this article, two array spectroradiometers were characterized for nonlinearity. Significant nonlinearities, in excess of 10%, as a function of analog-to-digital converter counts were discovered. Additional nonlinearities as a function of integration time were observed at very long integration times. No clear residual nonlinearity as a function of spectral irradiance was witnessed despite the characterization spanning four orders of magnitude of spectral irradiance. The characterizations were carried out with three measurement setups that are briefly compared.
- 6 April 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (11) , 3077-3086
Nonlinearity characterization of array spectroradiometers for the solar UV measurements
Array spectroradiometers are attractive alternatives to scanning spectroradiometers in solar ultraviolet measurements. However, the measurement of solar spectral irradiance imposes stringent requirements for the linearity of the instruments. In this article, two array spectroradiometers were characterized for nonlinearity. Significant nonlinearities, in excess of 10%, as a function of analog-to-digital converter counts were discovered. Additional nonlinearities as a function of integration time were observed at very long integration times. No clear residual nonlinearity as a function of spectral irradiance was witnessed despite the characterization spanning four orders of magnitude of spectral irradiance. The characterizations were carried out with three measurement setups that are briefly compared.