Increased detector response in optical overfilled measurements due to gas lens formation by nitrogen flow through the entrance aperture
Open Access
- 24 June 2021
- journal article
- research article
- Published by IOP Publishing in Metrologia
- Vol. 58 (5) , 055008
Abstract
According to our experimental results, a nitrogen flow used to prevent dust and moisture entering a detector may influence measurements performed with trap detectors in overfilled conditions. A stable light source was measured with a wedged trap detector with 4 mm aperture, and the nitrogen flow rate was varied. The nitrogen flow was found to have the largest effect of up to 0.8% on the responsivity of the detector at around 1.0 l min−1 flow rate. The effect of nitrogen flow can be removed down to 0.02% by an added crossflow which removes the nitrogen out of the optical axis. In another experiment, the effect was removed almost completely by changing the flowing gas from nitrogen to synthetic dry air. We also present measurement results that indicate the responsivity changes with nitrogen to be smaller than 0.05% with underfilled beam geometry, even without the added crossflow. Based on simulations, the nitrogen flow through the detector forms a gradient-index type gas lens in front of the detector increasing the effective aperture area and thus the responsivity. In the underfilled measurement geometry there is no light close to the aperture edge which could be refracted inside the detector. Finally, we consider methods to ensure that the responsivity changes due to the gas flow remain below 0.05% in overfilled measurement geometry, without compromising the cleanliness of the detector with too small gas flow rate.Keywords
Funding Information
- European Metrology Programme for Innovation and Research (15SIB07 PhotoLED)
- Research Council of Finland (320167)
This publication has 23 references indexed in Scilit:
- Advantages of white LED lamps and new detector technology in photometryLight: Science & Applications, 2015
- New source and detector technology for the realization of photometric unitsMetrologia, 2014
- Predictable quantum efficient detector: I. Photodiodes and predicted responsivityMetrologia, 2013
- Improved calibration of the spectral responsivity of interference filter radiometers in the visible and near infrared spectral range at PTBMetrologia, 2003
- Intercomparison of characterization techniques of filter radiometers in the ultraviolet regionMetrologia, 2003
- Spectral irradiance measurements of tungsten lamps with filter radiometers in the spectral range 290 nm to 900 nmMetrologia, 2000
- Characterization of a polarization-independent transmission trap detectorApplied Optics, 1997
- Optical power and transmittance measurements and their use in detector-based realization of the luminous intensity scaleOptical Engineering, 1995
- Trap Detectors and their PropertiesMetrologia, 1991
- Silicon photodiode device with 100% external quantum efficiencyApplied Optics, 1983