XLXiangqiang Li

Xiangqiang Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiangqiang Li has a total of 65 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Influence Mechanism of Incident-End Impedance Mismatch on Multi-Branch Positioning and the Design of Coupling Network

    by Hengliang Zheng, Yuhua Wang, Xiangqiang Li, Yanming Han, Jianqiong Zhang, Qingfeng Wang, Yanwei Han

    Aiming at the problem that insulation fault location in multi-branch cable networks of train DC medium-voltage power supply systems is disturbed by impedance mismatch at the injection end, this paper proposes an impedance matching method based on a resistance–capacitance composite coupling network to suppress false reflections and improve location accuracy. Firstly, the mechanism of multiple false reflections caused by injection-end mismatch is theoretically analyzed, and the expression of reflected waves and their influence on waveform superposition are derived. On this basis, an RC coupling network is designed to achieve effective matching between the measurement end and the cable characteristic impedance (about 97 Ω) within the 8–12 MHz frequency band, suppressing the amplitude of false reflections to less than 2% of the incident wave. Verification through MATLAB R2022b/ANSYS Q3D 2024R2 co-simulation and a 1:8 scaled experimental platform shows that the proposed coupling network reduces the absolute fault location error in a multi-branch network from 6.936 m to 0.188 m, decreases waveform distortion by about 40.8% and lowers the equivalent noise enhancement factor by about 55.2%. This study provides a reliable front-end matching solution for accurate fault location in complex cable networks, with clear value for engineering applications.

  • Open Access

    Impedance Mismatch Mechanism and Matching Network Design of Incident End in Single-Core Cable Fault Location of IT System

    by Yanming Han, Qingfeng Wang, Jianqiong Zhang, Xiangqiang Li

    The reliability of the Medium-Voltage Direct-Current (MVDC) power supply system is crucial for train operation, as it powers control, communication, and other critical onboard systems. Accurately locating insulation faults within this system can significantly reduce troubleshooting difficulty and prevent major operational losses. This study addresses a key challenge in applying Time-Domain Reflectometry (TDR) for fault location in single-core cables of IT systems: the incident-end impedance mismatch caused by the variable characteristic impedance of such cables, which fluctuates with installation distance from a ground plane. First, the mechanism through which this mismatch attenuates the primary fault reflection and generates secondary reflections is theoretically modeled. A resistive-capacitive (RC) coupling network is then designed to achieve bidirectional impedance matching between the test equipment and the cable under test while maintaining essential DC isolation. Simulation and experimental results demonstrate that the proposed network effectively mitigates the mismatch issue. In experiments, it increased the proportion of the primary reflected wave entering the receiver by over 30 percentage points and suppressed the secondary reflection by approximately 80%. These improvements enhance waveform clarity and signal strength, directly leading to more accurate fault location. The proposed solution, validated in a railway context, also holds significant potential for improving insulation fault diagnosis in analogous high-voltage cable applications, such as electric vehicle powertrains.


  • Open Access

    A Study on Excitation Inrush Current and Overvoltage Mitigation Strategies Utilizing Phase Selection Control

    by Junting Yan, Qingfeng Wang, Jianqiong Zhang, Xiangqiang Li

    To address the challenges of system failures and equipment damage caused by excitation inrush currents and overvoltages during no-load energization of high-speed locomotive transformers, a simulation model was developed utilizing PSCAD electromagnetic transient simulation software. This study establishes a no-load switching simulation model for rolling stock transformers within PSCAD, analyzing variations in overvoltage and excitation inrush current amplitudes across different phase angles. Additionally, it compares excitation inrush current amplitudes under varying residual magnetism conditions. A phase-selective control strategy is proposed, integrating the hysteresis characteristics of the transformer core. The model’s accuracy is validated against empirical data obtained from a city train. Employing the Jiles–Atherton hysteresis model, the residual magnetism of the transformer core is quantified. Based on measured data, a relationship curve between switching phase and residual magnetism is fitted, enabling calculation of the optimal closing angle through the phase selection procedure. This approach effectively mitigates overvoltage and excitation inrush current hazards, thereby enhancing the operational safety of the train system.


  • Open Access

    Prediction Method of Closing Action Time of Vehicle Pneumatic Main Circuit Breaker Based on PCA and GBDT Algorithm

    by Ruoyu Li, Qingfeng Wang, Jianqiong Zhang, Xiangqiang Li

    The switching action of the main circuit breaker of the train will produce switching overvoltage. In order to suppress the switching overvoltage, the phase selection control of the circuit breaker is required. However, the mechanical structure of the train-mounted electronically controlled pneumatic vacuum main circuit breaker is too complicated, resulting in a large dispersion of its closing action time, which is not suitable for the traditional phase selection control system. In order to obtain the accurate closing action time, a method for predicting the closing action time of train electronically controlled pneumatic vacuum main circuit breaker based on the PCA and GBDT algorithm is proposed. The relationship between the closing phase of AC25 kV power supply train and the peak value of switching overvoltage is obtained by simulation and field test, and the accuracy requirement of the prediction model is determined, that is, the prediction error should be within ±3.3 ms. The final prediction results show that the prediction error of the on-board electronically controlled pneumatic vacuum main circuit breaker closing action time prediction model based on the PCA and GBDT algorithm is controlled within ±3.3 ms, and the probability is 92%, which meets the accuracy requirements of phase selection control.


  • Open Access

    An Overmoded-Waveguide-Based Permittivity Measurement Method with High Accuracy and Ultra-Broadband over 8–110 GHz

    by Weijie Wang, Yingjian Cao, Tieyang Wang, Fangfang Song, Shuanzhu Fang, Xianfeng Tang, Xiangqiang Li, Guoxiang Shu, Guo Liu

    An overmoded-waveguide-based kit operating in 8–110 GHz for material complex permittivity measurement is proposed and designed in this paper. It overcomes the significant errors caused by air gaps in the conventional standard waveguide method (SWM), especially for millimeter-wave frequency bands. Furthermore, it avoids the problem of SWM requiring different samples in broadband measurements. The proposed kit consists of an overmoded-waveguide sample fixture with cross dimensions of 22.86 mm × 10.16 mm, seven pairs of standard-overmoded waveguide transition structures for different frequency bands, and thru-reflect-line calibration kits. The air gap problem, a major error source in millimeter-wave measurement, is quantitatively investigated. Compared with the SWM method, the proposed kit can decrease errors from over 68% to below 8%. The proposed method was verified by measuring the polytetrafluoroethylene sample. Then, it was applied to measure the BeO-TiO2 ceramic, which is widely used in vacuum devices. The measured data are valuable for applying BeO-TiO2 ceramics in relevant devices and developing its dielectric relaxation model.


  • Metamaterial-Inspired Slow Wave Structure for Enhanced Characteristics at Low Beam Voltages

    by Xianfeng Tang, Haosong Tang, Che Xu, Xiangqiang Li, Zhaoyun Duan

    Comb-type complementary electric split ring resonators (CeSRRs) are proposed to construct metamaterial (MTM)-inspired slow wave structures (SWSs). The proposed MTM-inspired SWS can significantly shift the dispersion curve downwards and move the operating point far from the cut-off frequency. The characteristics demonstrated by simulations and experiments lead to two advantages. Firstly, with the dispersion curve shifting downwards, the sizes of the MTM-inspired SWS relative to the operating wavelength would be correspondingly reduced. This can further enhance the miniaturization of the MTM-inspired SWS. Secondly, with the operating point far from the cut-off frequency, the output powers of the MTM-inspired BWOs can be enhanced at lower beam voltages compared to the initial one, which are predicted by particle-in-cell simulations. Thus, the proposed SWS can lower the beam voltages of the MTM-inspired BWOs, promoting their miniaturization and enhancing their performance.


  • Open Access

    A Metamaterial Bandpass Filter with End-Fire Coaxial Coupling

    by Xianfeng Tang, Yemin Zang, Xiangqiang Li, Che Xu

    A miniaturized metamaterial (MTM) bandpass filter (BPF) based on end-fire coaxial coupling is proposed. End-fire coaxial coupling is achieved by using the coaxial cavity to connect with the SubMiniature version A connector. The subwavelength characteristics of the MTM lead to the miniaturization advantages of the filter in transverse dimensions. Moreover, the longitudinal length of the coaxial cavity can be sharply reduced by introducing matched blocks. As a result, the proposed filter has miniaturization merit both in transverse and longitudinal dimensions. The full-wave simulation results further reveal that the MTM BPF exhibits the advantages of low loss, low reflection, and low group delay. Additionally, the fractional bandwidth is approximately 13% when |S11| is less than −15 dB. The MTM BPF might have potential applications to array antennas for easily being expanded to two dimensional arrays.


  • Electromagnetic-Transparent-Structure-Based Quad-Band Shared-Aperture Antenna With Multibeam in Millimeter Wave

    by Jinran Yin, Xiangqiang Li, Shucheng Ni, Jianqiong Zhang, Qingfeng Wang

    In this letter, a quad-band shared-aperture antenna with multi-beam in millimeter-wave (MMW) is proposed. The antenna is realized by integrating a microwave (MW) electromagnetic transparent tri-band filtering antenna with a MMW multi-beam substrate integrated waveguide (SIW) slot array antenna. By stacking the low-band (LB) and high-band (HB) antennas, the quad-band shared-aperture antenna is achieved. The LB antenna is realized by embedding a dual-band U-slot patch into a perforated patch, and the filtering function is achieved by introducing a stub-loaded resonator (SLR) into the feeding layer. To achieve electromagnetic transparency in MMW, the LB radiator is discretized by bandpass frequency selective surface (FSS) cells. The HB antenna is formed by a 4 × 5 SIW slot array and a 4 × 4 stacked Butler matrix, which achieves four independent beams in MMW. For verification, a prototype is fabricated and measured. In MW band, the antenna operates well at 2.55, 3.5, and 4.9 GHz, with peak gains of 6.8, 7.7, and 8.5 dBi, respectively. In MMW band, the beam directions of the antenna at 26 GHz are ±14° and ±44°, with peak gains of 15.2 and 14.1 dBi, respectively.