A 769 μW Battery-Powered Single-Chip SoC With BLE for Multi-Modal Vital Sign Monitoring Health Patches
Authors:
- Shuang SongShuang Song
- Peter VisPVPeter Vis
- Chris van LiempdCLChris van Liempd
- Chris van HoofCHChris van Hoof
- Nick van HelleputteNHNick van Helleputte
- Mario KonijnenburgMKMario Konijnenburg
- Roland van WegbergRWRoland van Wegberg
- Jiawei XuJXJiawei Xu
- Hyunsoo HaHHHyunsoo Ha
- Wim SijbersWSWim Sijbers
- Stefano StanzioneSSStefano Stanzione
- Dwaipayan BiswasDwaipayan Biswas
- 2 October 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1506-1517
Abstract
An all-in-one battery powered low-power SoC for measuring multiple vital signs with wearables is proposed. All functionality needed in a typical wearable use case scenario, including dedicated readouts, power management circuitry, digital signal processing and wireless communication (BLE) is integrated in a single die. This high level of integration allows an unprecedented level of miniaturization leading to smaller component count which reduces cost and improves comfort and signal integrity. The SoC includes an ECG, Bio-Impedance and a fully differential PPG readout and can interface with external sensors (like an IMU). In a typical application scenario where all sensor readouts are enabled and key features (like heart rate) are calculated on the chip and streamed over the radio, the SoC consumes only 769μW from the regulated 1.2V supply.Keywords
This publication has 16 references indexed in Scilit:
- A 1.55 μW Bio-Impedance Measurement System for Implantable Cardiac Pacemakers in 0.18 μm CMOSIEEE Transactions on Biomedical Circuits and Systems, 2018
- A survey of security in wireless sensor networks2017
- A Sub-60- $\mu \text{A}$ Multimodal Smart Biosensing SoC With >80-dB SNR, 35- $\mu \text{A}$ Photoplethysmography Signal ChainIEEE Journal of Solid-State Circuits, 2017
- A Multi(bio)sensor Acquisition System With Integrated Processor, Power Management, $8 \times 8$ LED Drivers, and Simultaneously Synchronized ECG, BIO-Z, GSR, and Two PPG ReadoutsIEEE Journal of Solid-State Circuits, 2016
- Security issues in Wireless Sensor Network — A review2016
- A Reconfigurable 5-to-14 bit SAR ADC for Battery-Powered Medical InstrumentationIEEE Transactions on Circuits and Systems I: Regular Papers, 2015
- A Low-Power, Dual-Wavelength Photoplethysmogram (PPG) SoC With Static and Time-Varying Interferer RemovalIEEE Transactions on Biomedical Circuits and Systems, 2014
- A 345 µW Multi-Sensor Biomedical SoC With Bio-Impedance, 3-Channel ECG, Motion Artifact Reduction, and Integrated DSPIEEE Journal of Solid-State Circuits, 2014
- Noise Limits of CMOS Current Interfaces for Biosensors: A ReviewIEEE Transactions on Biomedical Circuits and Systems, 2013
- A 10-bit Charge-Redistribution ADC Consuming 1.9 $\mu$W at 1 MS/sIEEE Journal of Solid-State Circuits, 2010