BRBahareh Rezaei

Bahareh Rezaei

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bahareh Rezaei has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Magnetic nanoparticle contrast agents for MRI: structure-property relationships, in vivo applications, and future theranostic directions

    by Bahareh Rezaei, Shahriar Mostufa, Karla Mercedes Paz González, Ebrahim Azizi, Changzhi Li, Jenifer Gómez-Pastora, Rui He, Kai Wu

    Magnetic resonance imaging (MRI) is a non-invasive and non-ionizing imaging modality that provides high-resolution images of internal organs such as the breast, brain, and cardiovascular system, enabling three-dimensional visualization of soft tissues. While MRI offers excellent soft tissue contrast, its sensitivity can be further enhanced using contrast agents, and many clinical applications rely on exogenous agents to improve detection and diagnostic accuracy. Two primary classes are used clinically: paramagnetic substances, exemplified by gadolinium (Gd), which predominantly shorten longitudinal ( T 1 ) relaxation, and superparamagnetic iron oxide nanoparticles (SPIONs), which exert strong effects on transverse ( T 2 ) relaxation. The performance and safety of these agents are strongly influenced by their pharmacokinetics and biodistribution, including rapid recognition and clearance by the reticuloendothelial system, which can both enable liver–spleen imaging and limit target-specific contrast in other organs. In this review, we first summarize the fundamental principles of MRI contrast generation, with an emphasis on relaxation mechanisms relevant to magnetic nanoparticles (MNPs). We then discuss the use of MNPs as contrast agents in representative biomedical applications, focusing on cardiac, breast, and brain MRI and illustrating how organ-specific physiology constrains nanoparticle design and performance. Finally, we examine biocompatibility and safety considerations for both Gd-based agents and SPIONs, highlighting current regulatory concerns, open questions regarding long-term toxicity, and key challenges that must be addressed to translate next-generation nanoparticle-based MRI contrast agents into routine clinical practice.


  • Open Access

    Magnetic nanoparticles for cancer theranostics

    by Jaiden Hart, Linh Nguyen T Tran, Tamara Faranaz Ena, Niranjan A Natekar, Bahareh Rezaei, Yipeng Jiao, Hansong Zuo, Hanlei Wang, Vinit Chugh, Ebrahim Azizi, et al.

    Magnetic nanoparticles (MNPs) have emerged as a powerful tool in cancer theranostics due to their unique size-dependent magnetic properties, surface functionalization capabilities, and responsiveness to external magnetic fields. This review outlines different types of MNPs, including those composed of pure metals, metal oxides, and metallic alloys, and highlights their size-dependent magnetic behavior, such as superparamagnetism and dynamic magnetizations. We also explore the critical role of surface modification strategies in enhancing MNPs’ biocompatibility, colloidal stability, and functional versatility for targeted biomedical applications. The applications of MNPs in cancer therapy are discussed, with a focus on magnetic hyperthermia, drug and gene delivery, and a combination of various therapies. Additionally, we examine their cancer diagnostic roles in imaging techniques such as magnetic resonance imaging (MRI) and magnetic particle imaging (MPI), and emerging magnetic biosensing technologies such as giant magnetoresistance (GMR), magnetic tunnel junction (MTJ), magnetic particle spectroscopy (MPS), and nuclear magnetic resonance (NMR)-based platforms. These advances collectively establish MNPs as key components in the future of personalized cancer diagnosis and treatment.


  • Open Access

    Characterizing the physicochemical properties of magnetic nanoparticles by a surface plasmon resonance approach

    by Shahriar Mostufa, Bahareh Rezaei, Ebrahim Azizi, Yongqiang Andrew Wang, Changzhi Li, Jenifer Gómez-Pastora, Rui He, Kai Wu

    Magnetic nanoparticles (MNPs) are widely recognized as effective signal amplifiers for surface plasmon resonance (SPR)-based biosensors. Herein, we report that SPR sensors can be a useful tool to characterize the physicochemical properties of surface-functionalized iron oxide MNPs. In this work, a Kretschmann configuration-based SPR sensing platform with a scanning angular range of up to 17° is employed to identify the resonance conditions of different MNP suspensions. We demonstrate the feasibility of SPR for differentiating different surface coatings on the iron oxide MNPs, such as amine, biotin, and streptavidin, as well as distinguishing different magnetic core sizes (from 15 nm to 30 nm) and nanoparticle concentrations (from 0.013 mg/ml to 2.5 mg/ml). The SPR resonance angle shift, Δθ, is used as a crucial parameter for characterizing these physicochemical properties of MNPs floating within the surface of the metal layer that can directly interact with the surface plasmons, and the variation of their physicochemical properties is the reason causing a shift in the SPR resonance angle.


  • Open Access

    Applying stochastic Langevin function with coupled Brownian–Néel relaxations to study the dynamic magnetizations of nanoparticle tracers in magnetic particle imaging

    by Ebrahim Azizi, Shahriar Mostufa, Bahareh Rezaei, Shumin Xin, Jiajia Sun, Zongqian Shi, Jenifer Gómez-Pastora, Kai Wu

    Magnetic particle imaging (MPI) is a new imaging technique that utilizes biologically safe iron oxide nanoparticle tracers for medical imaging. Although in the preclinical stage, MPI has shown strong potential for applications such as cell tracking, angiography, cancer imaging, etc. With the ever-growing research interest in MPI and the increasing desire to apply it in clinical medical imaging, the design of tracers, MPI systems, image reconstruction algorithms, and other related components has become increasingly critical. To date, most of the theoretical studies in MPI rely on the static Langevin function to describe the magnetization responses of superparamagnetic iron oxide nanoparticle (SPION) tracers. However, under a fast-changing excitation field (usually tens of kHz), the magnetic relaxation time of SPION tracers is no longer negligible, thus, the static Langevin function is inaccurate in explaining the tracers’ magnetic signals in MPI. Herein, we apply a stochastic Langevin function with coupled Brownian–Néel relaxation models to study the dynamic magnetization responses of SPION tracers in MPI. The time domain magnetization responses (M–t curve), dynamic magnetization-field hysteresis loops (M–H curve), and point spread functions are modeled for different SPION tracer designs with varying physical and magnetic properties. Our results show that larger magnetic core sizesreduce the MPI spatial resolution. Conversely, thicker non-magnetic coatings on tracers do not significantly affect the spatial resolution. The increased anisotropy diminishes the MPI resolution, and a higher saturation magnetization favors higher MPI resolution.


  • Computational Predictions on the Magnetic Particle Imaging Performance of Tracers Subjected to Magnetic Dipole–Dipole Interactions

    by Ebrahim Azizi, Shahriar Mostufa, Bahareh Rezaei, Shumin Xin, Jiajia Sun, Zongqian Shi, Jenifer Gómez-Pastora, Kai Wu

    Magnetic particle imaging (MPI) is a tracer-based tomographic imaging technique recognized for its tissue-depth-independent sensitivity, quantitative accuracy, and high spatial and temporal resolution. Superparamagnetic iron oxide nanoparticle (SPION) tracers are widely used in MPI research for applications such as cancer imaging, cardiovascular imaging, stem cell tracking, drug delivery monitoring. As MPI transitions toward clinical use, several challenges remain to be addressed, including tracer design, image reconstruction algorithms, and optimized field configurations, to achieve improved imaging performance. The magnetic dipole-dipole interactions (dipolar interactions) between magnetized tracers are often overlooked in applications such as magnetic sensing, imaging, and separation. However, in imaging scenarios where tracers target tumors, stem cells, or similar applications, surface-functionalized tracers tend to aggregate at target sites, leading to reduced interparticle distances where dipolar fields from neighboring tracers become significant. This study investigates the impact of magnetic dipolar interactions among SPION tracers on MPI imaging performance by tuning the inter-particle distances. Using the stochastic Langevin function, we modeled an ensemble of 1000 SPION tracers within a field-free region (FFR). Key magnetization dynamics such as time-domain magnetization responses, magnetization-field response (M–H) curves, voltage signals recorded by receiver coils, higher harmonics, and point spread functions (PSFs) were analyzed. Here, higher harmonics and the full width at half maximum (FWHM) of the PSFs serve as indicators for evaluating the impact of dipolar interactions on MPI performance.


  • Open Access

    Effect of tracer size distribution on magnetic particle imaging performance

    by Ebrahim Azizi, Bahareh Rezaei, Shahriar Mostufa, Shuang Liang, Yongqiang Andrew Wang, Vinit Kumar Chugh, Jian-Ping Wang, Changzhi Li, Jenifer Gómez-Pastora, Rui He, et al.

    Magnetic particle imaging (MPI) is a tracer-based tomographic imaging technique utilized in applications such as lung perfusion imaging, cancer diagnosis, stem cell tracking, etc. The goal of translating MPI to clinical use has prompted studies on further improving the spatial-temporal resolutions of MPI through various methods, including image reconstruction algorithm, scanning trajectory design, magnetic field profile design, and tracer design. Iron oxide magnetic nanoparticles (MNPs) are favored for MPI and magnetic resonance imaging (MRI) over other materials due to their high biocompatibility, low cost, and ease of preparation and surface modification. For core–shell MNPs, the tracers’ magnetic core size and non-magnetic coating layer characteristics can significantly affect MPI signals through dynamic magnetization relaxations. Most works to date have assumed an ensemble of MNP tracers with identical sizes, ignoring that artificially synthesized MNPs typically follow a log-normal size distribution, which can deviate theoretical results from experimental data. In this work, we first characterize the size distributions of four commercially available iron oxide MNP products and then model the collective magnetic responses of these MNPs for MPI applications. For an ensemble of MNP tracers with size standard deviations of σ, we applied a stochastic Langevin model to study the effect of size distribution on MPI imaging performance. Under an alternating magnetic field (AMF), i.e., the excitation field in MPI, we collected the time domain dynamic magnetizations (M-t curves), magnetization-field hysteresis loops (M-H curves), point-spread functions (PSFs), and higher harmonics from these MNP tracers. The intrinsic MPI spatial resolution, which is related to the full width at half maximum (FWHM) of the PSF profile, along with the higher harmonics, serve as metrics to provide insights into how the size distribution of MNP tracers affects MPI performance.


  • Investigation on the Magnetic Hyperthermia Performance of Commercial Iron Oxide Magnetic Nanoparticles

    by Bahareh Rezaei, Shahriar Mostufa, Ebrahim Azizi, Yongqiang Andrew Wang, Changzhi Li, Jenifer Gómez-Pastora, Rui He, Kai Wu

    Magnetic hyperthermia therapy is an evolving treatment for tumors where magnetic nanoparticles (MNPs) are directed to the tumor and exposed to an alternating magnetic field (AMF). This induces localized heating, causing the apoptosis of cancer cells. Monitoring heat delivery in a noninvasive, real-time manner is crucial for predicting clinical outcomes. This precise control over the hyperthermia process allows for targeted temperature adjustments in the range of 42 °C–46 °C, effectively targeting cancer cells while minimizing damage to surrounding healthy tissue. Factors, such as MNP size, medium viscosity, and AMF frequency and amplitude, influence the hyperthermia performance. Optimizing these factors enhances heat dissipation through mechanisms, such as hysteresis loss and Néel and Brownian relaxations, improving the intrinsic loss power (ILP) of the MNPs. In this study, we meticulously measure the temperature–time curves (T–t curves) and ILP values of several commercially available iron oxide MNP products. By systematically varying the concentration and magnetic core size of the MNPs and tuning the frequency and amplitude of the AMF, we aim to elucidate how these factors collectively influence heat dissipation. This, in turn, enhances our understanding of the optimal conditions for in vivo hyperthermia treatment. Our results indicate that among the MNP products tested, the 30 nm single-core MNPs exhibited the highest ILP. Additionally, for different MNP concentrations, the 50 nm multi-core MNPs show the highest ILP at a concentration of 2 mg/mL.


  • Open Access

    Roadmap on magnetic nanoparticles in nanomedicine

    by Kai Wu, Jian-Ping Wang, Niranjan A Natekar, Stefano Ciannella, Cristina González-Fernández, Jenifer Gomez-Pastora, Yuping Bao, Jinming Liu, Shuang Liang, Xian Wu, et al.

    Magnetic nanoparticles (MNPs) represent a class of small particles typically with diameters ranging from 1 to 100 nanometers. These nanoparticles are composed of magnetic materials such as iron, cobalt, nickel, or their alloys. The nanoscale size of MNPs gives them unique physicochemical (physical and chemical) properties not found in their bulk counterparts. Their versatile nature and unique magnetic behavior make them valuable in a wide range of scientific, medical, and technological fields. Over the past decade, there has been a significant surge in MNP-based applications spanning biomedical uses, environmental remediation, data storage, energy storage, and catalysis. Given their magnetic nature and small size, MNPs can be manipulated and guided using external magnetic fields. This characteristic is harnessed in biomedical applications, where these nanoparticles can be directed to specific targets in the body for imaging, drug delivery, or hyperthermia treatment. Herein, this roadmap offers an overview of the current status, challenges, and advancements in various facets of MNPs. It covers magnetic properties, synthesis, functionalization, characterization, and biomedical applications such as sample enrichment, bioassays, imaging, hyperthermia, neuromodulation, tissue engineering, and drug/gene delivery. However, as MNPs are increasingly explored for in vivo applications, concerns have emerged regarding their cytotoxicity, cellular uptake, and degradation, prompting attention from both researchers and clinicians. This roadmap aims to provide a comprehensive perspective on the evolving landscape of MNP research.


  • Top Cited Papers

    Magnetic Nanoparticles: A Review on Synthesis, Characterization, Functionalization, and Biomedical Applications

    by Bahareh Rezaei, Parsa Yari, Sean M. Sanders, Haotong Wang, Vinit Kumar Chugh, Shuang Liang, Shahriar Mostufa, Kanglin Xu, Jian‐Ping Wang, Jenifer Gómez‐Pastora, et al.

    Nowadays, magnetic nanoparticles (MNPs) are applied in numerous fields, especially in biomedical applications. Since biofluidic samples and biological tissues are nonmagnetic, negligible background signals can interfere with the magnetic signals from MNPs in magnetic biosensing and imaging applications. In addition, the MNPs can be remotely controlled by magnetic fields, which make it possible for magnetic separation and targeted drug delivery. Furthermore, due to the unique dynamic magnetizations of MNPs when subjected to alternating magnetic fields, MNPs are also proposed as a key tool in cancer treatment, an example is magnetic hyperthermia therapy. Due to their distinct surface chemistry, good biocompatibility, and inducible magnetic moments, the material and morphological structure design of MNPs has attracted enormous interest from a variety of scientific domains. Herein, a thorough review of the chemical synthesis strategies of MNPs, the methodologies to modify the MNPs surface for better biocompatibility, the physicochemical characterization techniques for MNPs, as well as some representative applications of MNPs in disease diagnosis and treatment are provided. Further portions of the review go into the diagnostic and therapeutic uses of composite MNPs with core/shell structures as well as a deeper analysis of MNP properties to learn about potential biomedical applications.


  • Metamaterial as perfect absorber for high sensitivity refractive index based biosensing applications at infrared frequencies

    by Shahriar Mostufa, Parsa Yari, Bahareh Rezaei, Kanglin Xu, Jiajia Sun, Zongqian Shi, Kai Wu

    In this paper, we introduce a novel design of a metamaterial unit cell absorber, which is based on a metal/insulator/metal sandwich structure. The design is subjected to comprehensive finite element method computational analysis to ensure accurate and reliable results. The proposed metamaterial sandwich structure demonstrates exceptional absorption performance, achieving a nearly perfect absorption rate of 99.996% at the resonance infrared frequency of 39.8 THz. To provide a detailed theoretical explanation of nearly perfect absorption, we employ the effective medium theory, impedance matching, and field distribution analysis. Additionally, we have optimized the structural parameters of the sensor to maximize its absorption peak. This includes optimizing the thickness of the gold (Au) layer (from 0.03 to 0.28 μm), the distance between the L shape corners (from 0.60 to 0.90 μm), and the thickness of SiC dielectric spacer (from 0.20 to 0.45 μm). Furthermore, we showcase the remarkable sensitivity of the proposed metamaterial unit cell in detecting subtle changes in the refractive index through the implementation of a sensing medium setup in our model. Remarkably, we achieve a frequency shift sensitivity of 3.74 THz/RIU, along with a quality factor of 10.33, for a wide range of refractive indices (1.0–2.0). Moreover, for cancer detection, we attain a sensitivity of 3.5 THz/RIU. These findings highlight the exceptional performance of our approach in accurately detecting changes in refractive index, making it a promising candidate for various sensing applications. The novelty of our work lies in the design of a metamaterial unit cell structure. This configuration exhibits several noteworthy features, including wide incident angle ( θ ) coverage up to 60°, polarization insensitivity, exceptional frequency shift sensitivity, high absorption peaks across a wide range of refractive indices, and the ability to distinguish cancer cells from healthy ones.