Shahriar Mostufa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shahriar Mostufa has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Kai Wu
University of South Florida
19 shared publications - Bahareh Rezaei
Department of Electrical and Computer Engineering, Texas Tech University, 910 Boston Ave, Lubbock, Texas, 79409, UNITED STATES
10 shared publications - Jenifer Gómez-Pastora
Department of Chemical Engineering, Texas Tech University, 910 Boston Ave, Lubbock, Texas, 79409, United States
10 shared publications Bahareh Rezaei
Texas Tech University
8 shared publications- Ebrahim Azizi
Texas Tech University, Lubbock, TX 79409, United States, Lubbock, Texas, 79409, United States
7 shared publications - Rui He
Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA
6 shared publications
Latest Publications
- 29 July 2026
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 9 (16) , 7671-7681
Core Size and PEG Coating Govern the Dual Magnetic Particle Imaging and Hyperthermia Performance of Iron Oxide Nanoparticles
Magnetic particle imaging (MPI) and magnetic hyperthermia therapy (MHT) both rely strongly on the dynamic magnetic response of magnetic nanoparticles (MNPs), yet the particle design requirements for achieving strong imaging contrast and efficient heating are not always aligned. Here, we systematically investigate the effects of core size and PEG surface coating on the dual MPI−MHT performance of iron oxide MNPs. Six formulations with core sizes of 10, 20, and 30 nm, either uncoated Fe3O4 or PEG-coated Fe3O4 (Fe3O4@PEG), were systematically evaluated. MPI performance was assessed using magnetic particle spectroscopy (MPS) under an excitation field of 10 mT at 7.7 and 11.4 kHz. Harmonic analysis revealed that 20 nm Fe3O4@PEG nanoparticles generated the strongest MPI response, characterized by enhanced higher-order harmonic magnitudes and slower harmonic decay. MHT performance was then evaluated under various alternating magnetic field (AMF) conditions: 30 mT at 101.5 kHz, 15 mT at 434.4 kHz, 25 mT at 252.5 kHz, and 10 mT at 951.8 kHz. Results demonstrate that 20 nm Fe3O4@PEG nanoparticles also showed superior heating efficiency, especially under low-field, high-frequency excitation. These findings suggest that a 20 nm core size, combined with a PEG coating, provides an optimal balance between rapid magnetic response, colloidal stability, and energy dissipation. Furthermore, colloidal stability over seven days and cell viability assays confirm that the MNPs are colloidally stable and that 20 and 30 nm MNPs are biocompatible under the tested conditions for up to 48 h. This study provides a rational design framework for developing dual-functional iron oxide nanoparticles for image-guided magnetic hyperthermia and other integrated diagnostic−therapeutic biomedical applications.
- 29 July 2026
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 9 (16) , 7671-7681
Core Size and PEG Coating Govern the Dual Magnetic Particle Imaging and Hyperthermia Performance of Iron Oxide Nanoparticles
Magnetic particle imaging (MPI) and magnetic hyperthermia therapy (MHT) both rely strongly on the dynamic magnetic response of magnetic nanoparticles (MNPs), yet the particle design requirements for achieving strong imaging contrast and efficient heating are not always aligned. Here, we systematically investigate the effects of core size and PEG surface coating on the dual MPI−MHT performance of iron oxide MNPs. Six formulations with core sizes of 10, 20, and 30 nm, either uncoated Fe3O4 or PEG-coated Fe3O4 (Fe3O4@PEG), were systematically evaluated. MPI performance was assessed using magnetic particle spectroscopy (MPS) under an excitation field of 10 mT at 7.7 and 11.4 kHz. Harmonic analysis revealed that 20 nm Fe3O4@PEG nanoparticles generated the strongest MPI response, characterized by enhanced higher-order harmonic magnitudes and slower harmonic decay. MHT performance was then evaluated under various alternating magnetic field (AMF) conditions: 30 mT at 101.5 kHz, 15 mT at 434.4 kHz, 25 mT at 252.5 kHz, and 10 mT at 951.8 kHz. Results demonstrate that 20 nm Fe3O4@PEG nanoparticles also showed superior heating efficiency, especially under low-field, high-frequency excitation. These findings suggest that a 20 nm core size, combined with a PEG coating, provides an optimal balance between rapid magnetic response, colloidal stability, and energy dissipation. Furthermore, colloidal stability over seven days and cell viability assays confirm that the MNPs are colloidally stable and that 20 and 30 nm MNPs are biocompatible under the tested conditions for up to 48 h. This study provides a rational design framework for developing dual-functional iron oxide nanoparticles for image-guided magnetic hyperthermia and other integrated diagnostic−therapeutic biomedical applications.
- Top Cited PapersOpen Access
- 16 March 2026
- Published by IOP Publishing in Nanotechnology
- Vol. 37 (11) , 112001
Magnetic nanoparticle contrast agents for MRI: structure-property relationships, in vivo applications, and future theranostic directions
Magnetic resonance imaging (MRI) is a non-invasive and non-ionizing imaging modality that provides high-resolution images of internal organs such as the breast, brain, and cardiovascular system, enabling three-dimensional visualization of soft tissues. While MRI offers excellent soft tissue contrast, its sensitivity can be further enhanced using contrast agents, and many clinical applications rely on exogenous agents to improve detection and diagnostic accuracy. Two primary classes are used clinically: paramagnetic substances, exemplified by gadolinium (Gd), which predominantly shorten longitudinal ( T 1 ) relaxation, and superparamagnetic iron oxide nanoparticles (SPIONs), which exert strong effects on transverse ( T 2 ) relaxation. The performance and safety of these agents are strongly influenced by their pharmacokinetics and biodistribution, including rapid recognition and clearance by the reticuloendothelial system, which can both enable liver–spleen imaging and limit target-specific contrast in other organs. In this review, we first summarize the fundamental principles of MRI contrast generation, with an emphasis on relaxation mechanisms relevant to magnetic nanoparticles (MNPs). We then discuss the use of MNPs as contrast agents in representative biomedical applications, focusing on cardiac, breast, and brain MRI and illustrating how organ-specific physiology constrains nanoparticle design and performance. Finally, we examine biocompatibility and safety considerations for both Gd-based agents and SPIONs, highlighting current regulatory concerns, open questions regarding long-term toxicity, and key challenges that must be addressed to translate next-generation nanoparticle-based MRI contrast agents into routine clinical practice.
- 16 March 2026
- Published by IOP Publishing in Nanotechnology
- Vol. 37 (11) , 112001
Top Cited PapersOpen AccessMagnetic nanoparticle contrast agents for MRI: structure-property relationships, in vivo applications, and future theranostic directions
Magnetic resonance imaging (MRI) is a non-invasive and non-ionizing imaging modality that provides high-resolution images of internal organs such as the breast, brain, and cardiovascular system, enabling three-dimensional visualization of soft tissues. While MRI offers excellent soft tissue contrast, its sensitivity can be further enhanced using contrast agents, and many clinical applications rely on exogenous agents to improve detection and diagnostic accuracy. Two primary classes are used clinically: paramagnetic substances, exemplified by gadolinium (Gd), which predominantly shorten longitudinal ( T 1 ) relaxation, and superparamagnetic iron oxide nanoparticles (SPIONs), which exert strong effects on transverse ( T 2 ) relaxation. The performance and safety of these agents are strongly influenced by their pharmacokinetics and biodistribution, including rapid recognition and clearance by the reticuloendothelial system, which can both enable liver–spleen imaging and limit target-specific contrast in other organs. In this review, we first summarize the fundamental principles of MRI contrast generation, with an emphasis on relaxation mechanisms relevant to magnetic nanoparticles (MNPs). We then discuss the use of MNPs as contrast agents in representative biomedical applications, focusing on cardiac, breast, and brain MRI and illustrating how organ-specific physiology constrains nanoparticle design and performance. Finally, we examine biocompatibility and safety considerations for both Gd-based agents and SPIONs, highlighting current regulatory concerns, open questions regarding long-term toxicity, and key challenges that must be addressed to translate next-generation nanoparticle-based MRI contrast agents into routine clinical practice.
- Open Access
- 1 March 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (3)
Computational design of a 3D magnetic particle imaging (MPI) prototype
Magnetic particle imaging (MPI) is an emerging imaging modality that exploits the magnetization response of magnetic nanoparticle tracers. While MPI offers substantially higher resolution compared to magnetic resonance imaging, its translation to human-scale applications remains limited. These challenges stem from the requirement of high-intensity electric currents to generate strong magnetic fields, as well as reduced field uniformity with increasing coil spacing. To overcome these barriers, comprehensive simulation studies are essential for guiding MPI prototype design and performance optimization. In this work, we present a finite element method (FEM)-based design of a three-dimensional (3D) MPI prototype. The system integrates electromagnetic coils for the selection, drive, and focus fields, along with a gradiometer configuration for signal reception. Each coil’s geometry and magnetic field were first simulated independently to validate its ability to generate the desired magnetic field and subsequently combined into a full-system design with time-domain input excitation signals. This framework achieved 3D field-free point (FFP) scanning within a 20 mm3 field of view. The selection field provided a gradient of 4, 2, and 2 T/m in z axis, y axis, and x axis, respectively, the drive field produced 20 mT, and the focus fields generated 40 mT (z-axis) and 20 mT (y-axis), enabling controlled spatial movement of the FFP. Overall, this study establishes a complete 3D FEM simulation framework for MPI system design and lays the foundation for future optimization toward clinical-scale applications.
- 1 March 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (3)
Open AccessComputational design of a 3D magnetic particle imaging (MPI) prototype
Magnetic particle imaging (MPI) is an emerging imaging modality that exploits the magnetization response of magnetic nanoparticle tracers. While MPI offers substantially higher resolution compared to magnetic resonance imaging, its translation to human-scale applications remains limited. These challenges stem from the requirement of high-intensity electric currents to generate strong magnetic fields, as well as reduced field uniformity with increasing coil spacing. To overcome these barriers, comprehensive simulation studies are essential for guiding MPI prototype design and performance optimization. In this work, we present a finite element method (FEM)-based design of a three-dimensional (3D) MPI prototype. The system integrates electromagnetic coils for the selection, drive, and focus fields, along with a gradiometer configuration for signal reception. Each coil’s geometry and magnetic field were first simulated independently to validate its ability to generate the desired magnetic field and subsequently combined into a full-system design with time-domain input excitation signals. This framework achieved 3D field-free point (FFP) scanning within a 20 mm3 field of view. The selection field provided a gradient of 4, 2, and 2 T/m in z axis, y axis, and x axis, respectively, the drive field produced 20 mT, and the focus fields generated 40 mT (z-axis) and 20 mT (y-axis), enabling controlled spatial movement of the FFP. Overall, this study establishes a complete 3D FEM simulation framework for MPI system design and lays the foundation for future optimization toward clinical-scale applications.
- 19 January 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 18 (9) , 4568-4580
Non-traditional granular magnetoresistive devices: a short review
This review is focused on non-traditional granular magnetoresistive (MR) sensors. It discusses the underlying physical mechanisms, material configurations, fabrication strategies, and MR device performance evolution over the past two decades.
- 19 January 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 18 (9) , 4568-4580
Non-traditional granular magnetoresistive devices: a short review
This review is focused on non-traditional granular magnetoresistive (MR) sensors. It discusses the underlying physical mechanisms, material configurations, fabrication strategies, and MR device performance evolution over the past two decades.
- 13 May 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (11) , 2521-2565
Blood cell separation with magnetic techniques: a critical review
Blood cell separation is a critical process for many clinical and research applications. Among the various techniques employed for blood cell isolation, magnetic techniques are very attractive due to their multiple benefits, i.e. high efficiency, simplicity, low-cost, and no need for expensive equipment or trained operators. Microfluidic devices integrating magnetophoresis have demonstrated promising results for high-throughput separation, with some achieving separation rates of over 108 cells per hour. However, there are many different approaches that can be used for blood magnetic separations, with the selection depending on the sample properties, target cells and purpose of the isolated fractions. This critical review examines recent advances (2014–2025) in magnetic techniques for separating blood cells. Both labeled and label-free approaches are analyzed, with a focus on their performance and impact on cellular function, highlighting their strengths, limitations, and potential for future development in clinical research applications. Among the labeled approaches, positive selection methods have been shown to achieve high purities for various cell types; nevertheless, these techniques might affect cell functionality after separation. Therefore, negative selection can be used for the separation of cells when cellular functionality needs to be preserved. Moreover, label-free techniques, primarily focused on red blood cells (RBCs) separation, can be used for blood cell isolation by leveraging the cells' intrinsic magnetic properties. These methods showed potential for continuous, high-purity RBCs separation, with some devices achieving over 95% recovery and purity. This work aims to provide valuable guidelines for the appropriate selection of magnetic technologies for blood separations to accomplish the successful implementation of magnetophoresis in clinical practice.
- 13 May 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (11) , 2521-2565
Blood cell separation with magnetic techniques: a critical review
Blood cell separation is a critical process for many clinical and research applications. Among the various techniques employed for blood cell isolation, magnetic techniques are very attractive due to their multiple benefits, i.e. high efficiency, simplicity, low-cost, and no need for expensive equipment or trained operators. Microfluidic devices integrating magnetophoresis have demonstrated promising results for high-throughput separation, with some achieving separation rates of over 108 cells per hour. However, there are many different approaches that can be used for blood magnetic separations, with the selection depending on the sample properties, target cells and purpose of the isolated fractions. This critical review examines recent advances (2014–2025) in magnetic techniques for separating blood cells. Both labeled and label-free approaches are analyzed, with a focus on their performance and impact on cellular function, highlighting their strengths, limitations, and potential for future development in clinical research applications. Among the labeled approaches, positive selection methods have been shown to achieve high purities for various cell types; nevertheless, these techniques might affect cell functionality after separation. Therefore, negative selection can be used for the separation of cells when cellular functionality needs to be preserved. Moreover, label-free techniques, primarily focused on red blood cells (RBCs) separation, can be used for blood cell isolation by leveraging the cells' intrinsic magnetic properties. These methods showed potential for continuous, high-purity RBCs separation, with some devices achieving over 95% recovery and purity. This work aims to provide valuable guidelines for the appropriate selection of magnetic technologies for blood separations to accomplish the successful implementation of magnetophoresis in clinical practice.
- Open Access
- 1 March 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (3)
Characterizing the physicochemical properties of magnetic nanoparticles by a surface plasmon resonance approach
Magnetic nanoparticles (MNPs) are widely recognized as effective signal amplifiers for surface plasmon resonance (SPR)-based biosensors. Herein, we report that SPR sensors can be a useful tool to characterize the physicochemical properties of surface-functionalized iron oxide MNPs. In this work, a Kretschmann configuration-based SPR sensing platform with a scanning angular range of up to 17° is employed to identify the resonance conditions of different MNP suspensions. We demonstrate the feasibility of SPR for differentiating different surface coatings on the iron oxide MNPs, such as amine, biotin, and streptavidin, as well as distinguishing different magnetic core sizes (from 15 nm to 30 nm) and nanoparticle concentrations (from 0.013 mg/ml to 2.5 mg/ml). The SPR resonance angle shift, Δθ, is used as a crucial parameter for characterizing these physicochemical properties of MNPs floating within the surface of the metal layer that can directly interact with the surface plasmons, and the variation of their physicochemical properties is the reason causing a shift in the SPR resonance angle.
- 1 March 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (3)
Open AccessCharacterizing the physicochemical properties of magnetic nanoparticles by a surface plasmon resonance approach
Magnetic nanoparticles (MNPs) are widely recognized as effective signal amplifiers for surface plasmon resonance (SPR)-based biosensors. Herein, we report that SPR sensors can be a useful tool to characterize the physicochemical properties of surface-functionalized iron oxide MNPs. In this work, a Kretschmann configuration-based SPR sensing platform with a scanning angular range of up to 17° is employed to identify the resonance conditions of different MNP suspensions. We demonstrate the feasibility of SPR for differentiating different surface coatings on the iron oxide MNPs, such as amine, biotin, and streptavidin, as well as distinguishing different magnetic core sizes (from 15 nm to 30 nm) and nanoparticle concentrations (from 0.013 mg/ml to 2.5 mg/ml). The SPR resonance angle shift, Δθ, is used as a crucial parameter for characterizing these physicochemical properties of MNPs floating within the surface of the metal layer that can directly interact with the surface plasmons, and the variation of their physicochemical properties is the reason causing a shift in the SPR resonance angle.
- Open Access
- 1 March 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (3)
Numerical analysis of hybrid electromagnetic coil designs for efficient gradient field generation in magnetic particle imaging
Magnetic particle imaging (MPI) is an emerging tomographic imaging modality that has shown great potential for cell tracking, tumor imaging, gut bleeding, etc. As MPI moves towards clinical applications, one challenge faced by this technology is the increasing power consumption for field generation as the bore size increases. Joining the efforts in transitioning MPI to clinical applications, especially for human-sized MPI. Herein, using COMSOL Multiphysics, we numerically studied three coil designs for generating high gradient fields with high field uniformity at lower power consumption. Specifically, the Maxwell electromagnetic (EM) coils, the hybrid EM coils with an NdFeB magnet core, and the hybrid EM coils with an NdFeB magnet core designed as a magnetic flux concentrator (MFC). We first compared the efficiency of these three coil designs in generating gradient fields by evaluating the maximum gradient field strength and field uniformity. With the same current applied to these coils, the hybrid EM coils with a NdFeB MFC core show the best gradient field profiles, achieving a maximum gradient field strength of 5 T/m. The current supplied to these EM coils and the coil winding layers are varied to study their effects on the gradient field profiles. Additionally, the geometrical parameter of the MFC structure is optimized, and we have achieved a maximum gradient field strength of 5 T/m over a 14.3 cm space, with a tolerance of 98%.
- 1 March 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (3)
Open AccessNumerical analysis of hybrid electromagnetic coil designs for efficient gradient field generation in magnetic particle imaging
Magnetic particle imaging (MPI) is an emerging tomographic imaging modality that has shown great potential for cell tracking, tumor imaging, gut bleeding, etc. As MPI moves towards clinical applications, one challenge faced by this technology is the increasing power consumption for field generation as the bore size increases. Joining the efforts in transitioning MPI to clinical applications, especially for human-sized MPI. Herein, using COMSOL Multiphysics, we numerically studied three coil designs for generating high gradient fields with high field uniformity at lower power consumption. Specifically, the Maxwell electromagnetic (EM) coils, the hybrid EM coils with an NdFeB magnet core, and the hybrid EM coils with an NdFeB magnet core designed as a magnetic flux concentrator (MFC). We first compared the efficiency of these three coil designs in generating gradient fields by evaluating the maximum gradient field strength and field uniformity. With the same current applied to these coils, the hybrid EM coils with a NdFeB MFC core show the best gradient field profiles, achieving a maximum gradient field strength of 5 T/m. The current supplied to these EM coils and the coil winding layers are varied to study their effects on the gradient field profiles. Additionally, the geometrical parameter of the MFC structure is optimized, and we have achieved a maximum gradient field strength of 5 T/m over a 14.3 cm space, with a tolerance of 98%.
- Open Access
- 6 February 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (13) , 135002
Applying stochastic Langevin function with coupled Brownian–Néel relaxations to study the dynamic magnetizations of nanoparticle tracers in magnetic particle imaging
Magnetic particle imaging (MPI) is a new imaging technique that utilizes biologically safe iron oxide nanoparticle tracers for medical imaging. Although in the preclinical stage, MPI has shown strong potential for applications such as cell tracking, angiography, cancer imaging, etc. With the ever-growing research interest in MPI and the increasing desire to apply it in clinical medical imaging, the design of tracers, MPI systems, image reconstruction algorithms, and other related components has become increasingly critical. To date, most of the theoretical studies in MPI rely on the static Langevin function to describe the magnetization responses of superparamagnetic iron oxide nanoparticle (SPION) tracers. However, under a fast-changing excitation field (usually tens of kHz), the magnetic relaxation time of SPION tracers is no longer negligible, thus, the static Langevin function is inaccurate in explaining the tracers’ magnetic signals in MPI. Herein, we apply a stochastic Langevin function with coupled Brownian–Néel relaxation models to study the dynamic magnetization responses of SPION tracers in MPI. The time domain magnetization responses (M–t curve), dynamic magnetization-field hysteresis loops (M–H curve), and point spread functions are modeled for different SPION tracer designs with varying physical and magnetic properties. Our results show that larger magnetic core sizesreduce the MPI spatial resolution. Conversely, thicker non-magnetic coatings on tracers do not significantly affect the spatial resolution. The increased anisotropy diminishes the MPI resolution, and a higher saturation magnetization favors higher MPI resolution.
- 6 February 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (13) , 135002
Open AccessApplying stochastic Langevin function with coupled Brownian–Néel relaxations to study the dynamic magnetizations of nanoparticle tracers in magnetic particle imaging
Magnetic particle imaging (MPI) is a new imaging technique that utilizes biologically safe iron oxide nanoparticle tracers for medical imaging. Although in the preclinical stage, MPI has shown strong potential for applications such as cell tracking, angiography, cancer imaging, etc. With the ever-growing research interest in MPI and the increasing desire to apply it in clinical medical imaging, the design of tracers, MPI systems, image reconstruction algorithms, and other related components has become increasingly critical. To date, most of the theoretical studies in MPI rely on the static Langevin function to describe the magnetization responses of superparamagnetic iron oxide nanoparticle (SPION) tracers. However, under a fast-changing excitation field (usually tens of kHz), the magnetic relaxation time of SPION tracers is no longer negligible, thus, the static Langevin function is inaccurate in explaining the tracers’ magnetic signals in MPI. Herein, we apply a stochastic Langevin function with coupled Brownian–Néel relaxation models to study the dynamic magnetization responses of SPION tracers in MPI. The time domain magnetization responses (M–t curve), dynamic magnetization-field hysteresis loops (M–H curve), and point spread functions are modeled for different SPION tracer designs with varying physical and magnetic properties. Our results show that larger magnetic core sizesreduce the MPI spatial resolution. Conversely, thicker non-magnetic coatings on tracers do not significantly affect the spatial resolution. The increased anisotropy diminishes the MPI resolution, and a higher saturation magnetization favors higher MPI resolution.
- 4 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (9) , 1-5
Computational Predictions on the Magnetic Particle Imaging Performance of Tracers Subjected to Magnetic Dipole–Dipole Interactions
Magnetic particle imaging (MPI) is a tracer-based tomographic imaging technique recognized for its tissue-depth-independent sensitivity, quantitative accuracy, and high spatial and temporal resolution. Superparamagnetic iron oxide nanoparticle (SPION) tracers are widely used in MPI research for applications such as cancer imaging, cardiovascular imaging, stem cell tracking, drug delivery monitoring. As MPI transitions toward clinical use, several challenges remain to be addressed, including tracer design, image reconstruction algorithms, and optimized field configurations, to achieve improved imaging performance. The magnetic dipole-dipole interactions (dipolar interactions) between magnetized tracers are often overlooked in applications such as magnetic sensing, imaging, and separation. However, in imaging scenarios where tracers target tumors, stem cells, or similar applications, surface-functionalized tracers tend to aggregate at target sites, leading to reduced interparticle distances where dipolar fields from neighboring tracers become significant. This study investigates the impact of magnetic dipolar interactions among SPION tracers on MPI imaging performance by tuning the inter-particle distances. Using the stochastic Langevin function, we modeled an ensemble of 1000 SPION tracers within a field-free region (FFR). Key magnetization dynamics such as time-domain magnetization responses, magnetization-field response (M–H) curves, voltage signals recorded by receiver coils, higher harmonics, and point spread functions (PSFs) were analyzed. Here, higher harmonics and the full width at half maximum (FWHM) of the PSFs serve as indicators for evaluating the impact of dipolar interactions on MPI performance.
- 4 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (9) , 1-5
Computational Predictions on the Magnetic Particle Imaging Performance of Tracers Subjected to Magnetic Dipole–Dipole Interactions
Magnetic particle imaging (MPI) is a tracer-based tomographic imaging technique recognized for its tissue-depth-independent sensitivity, quantitative accuracy, and high spatial and temporal resolution. Superparamagnetic iron oxide nanoparticle (SPION) tracers are widely used in MPI research for applications such as cancer imaging, cardiovascular imaging, stem cell tracking, drug delivery monitoring. As MPI transitions toward clinical use, several challenges remain to be addressed, including tracer design, image reconstruction algorithms, and optimized field configurations, to achieve improved imaging performance. The magnetic dipole-dipole interactions (dipolar interactions) between magnetized tracers are often overlooked in applications such as magnetic sensing, imaging, and separation. However, in imaging scenarios where tracers target tumors, stem cells, or similar applications, surface-functionalized tracers tend to aggregate at target sites, leading to reduced interparticle distances where dipolar fields from neighboring tracers become significant. This study investigates the impact of magnetic dipolar interactions among SPION tracers on MPI imaging performance by tuning the inter-particle distances. Using the stochastic Langevin function, we modeled an ensemble of 1000 SPION tracers within a field-free region (FFR). Key magnetization dynamics such as time-domain magnetization responses, magnetization-field response (M–H) curves, voltage signals recorded by receiver coils, higher harmonics, and point spread functions (PSFs) were analyzed. Here, higher harmonics and the full width at half maximum (FWHM) of the PSFs serve as indicators for evaluating the impact of dipolar interactions on MPI performance.
- Open Access
- 28 January 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (2) , 025529
Effect of tracer size distribution on magnetic particle imaging performance
Magnetic particle imaging (MPI) is a tracer-based tomographic imaging technique utilized in applications such as lung perfusion imaging, cancer diagnosis, stem cell tracking, etc. The goal of translating MPI to clinical use has prompted studies on further improving the spatial-temporal resolutions of MPI through various methods, including image reconstruction algorithm, scanning trajectory design, magnetic field profile design, and tracer design. Iron oxide magnetic nanoparticles (MNPs) are favored for MPI and magnetic resonance imaging (MRI) over other materials due to their high biocompatibility, low cost, and ease of preparation and surface modification. For core–shell MNPs, the tracers’ magnetic core size and non-magnetic coating layer characteristics can significantly affect MPI signals through dynamic magnetization relaxations. Most works to date have assumed an ensemble of MNP tracers with identical sizes, ignoring that artificially synthesized MNPs typically follow a log-normal size distribution, which can deviate theoretical results from experimental data. In this work, we first characterize the size distributions of four commercially available iron oxide MNP products and then model the collective magnetic responses of these MNPs for MPI applications. For an ensemble of MNP tracers with size standard deviations of σ, we applied a stochastic Langevin model to study the effect of size distribution on MPI imaging performance. Under an alternating magnetic field (AMF), i.e., the excitation field in MPI, we collected the time domain dynamic magnetizations (M-t curves), magnetization-field hysteresis loops (M-H curves), point-spread functions (PSFs), and higher harmonics from these MNP tracers. The intrinsic MPI spatial resolution, which is related to the full width at half maximum (FWHM) of the PSF profile, along with the higher harmonics, serve as metrics to provide insights into how the size distribution of MNP tracers affects MPI performance.
- 28 January 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (2) , 025529
Open AccessEffect of tracer size distribution on magnetic particle imaging performance
Magnetic particle imaging (MPI) is a tracer-based tomographic imaging technique utilized in applications such as lung perfusion imaging, cancer diagnosis, stem cell tracking, etc. The goal of translating MPI to clinical use has prompted studies on further improving the spatial-temporal resolutions of MPI through various methods, including image reconstruction algorithm, scanning trajectory design, magnetic field profile design, and tracer design. Iron oxide magnetic nanoparticles (MNPs) are favored for MPI and magnetic resonance imaging (MRI) over other materials due to their high biocompatibility, low cost, and ease of preparation and surface modification. For core–shell MNPs, the tracers’ magnetic core size and non-magnetic coating layer characteristics can significantly affect MPI signals through dynamic magnetization relaxations. Most works to date have assumed an ensemble of MNP tracers with identical sizes, ignoring that artificially synthesized MNPs typically follow a log-normal size distribution, which can deviate theoretical results from experimental data. In this work, we first characterize the size distributions of four commercially available iron oxide MNP products and then model the collective magnetic responses of these MNPs for MPI applications. For an ensemble of MNP tracers with size standard deviations of σ, we applied a stochastic Langevin model to study the effect of size distribution on MPI imaging performance. Under an alternating magnetic field (AMF), i.e., the excitation field in MPI, we collected the time domain dynamic magnetizations (M-t curves), magnetization-field hysteresis loops (M-H curves), point-spread functions (PSFs), and higher harmonics from these MNP tracers. The intrinsic MPI spatial resolution, which is related to the full width at half maximum (FWHM) of the PSF profile, along with the higher harmonics, serve as metrics to provide insights into how the size distribution of MNP tracers affects MPI performance.