Jianping Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jianping Shi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Huixin Liang
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
2 shared publications - Lan Li
State Key Laboratory of Pharmaceutical Biotechnology, Department of Sports Medicine and Adult Reconstructive Surgery, Drum Tower Hospital Affiliated to Medical School of Nanjing University, Nanjing, China
2 shared publications - Liya Zhu
Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing, School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing, 210023, China.
2 shared publications - Longfei Yang
School of Mechanical Engineering, Southeast University, Nanjing, China
2 shared publications - Qing Jiang
State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China
2 shared publications - Xianfeng Yang
Department of Radiology, Drum Tower Hospital affiliated to Medical School of Nanjing University, Nanjing, China
2 shared publications
Latest Publications
- Open Access
- 25 July 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-12
The biomechanical changes of load distribution with longitudinal tears of meniscal horns on knee joint: a finite element analysis
Meniscal horns are important structures of meniscus, and longitudinal tears of these places could significantly change the load distribution among the knee joint. Few studies concerned the stress concentrated on bones, which may induce the osteonecrosis of subchondral bone. The goal of this study was to construct a finite element (FE) model with high fidelity of the knee joint and evaluate the biomechanical changes of load distribution of components after longitudinal tears of the horns of meniscus. Computed tomography and magnetic resonance images were used to develop the FE model, and two different kinds of simulations, the vertical and the anterior load, mimicking the static stance and slight flexion simulations, were applied after longitudinal tears of the horns of meniscus. Significantly elevated peak compressive and shear stress was observed on the menisci, cartilages, and subchondral bones, and enlarged meniscus extrusion was noticed. Between all the four types of longitudinal tears investigated in this study, longitudinal tears at the posterior horn of the medial meniscus were found to be the most significant. These findings showed that longitudinal tears of the meniscal horns lead to increased magnitude and changed distribution of stress and indicated the important role of posterior horn of medial meniscus. This may contribute to the mechanism between meniscal tears and spontaneous subchondral bone osteonecrosis.
- 25 July 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-12
Open AccessThe biomechanical changes of load distribution with longitudinal tears of meniscal horns on knee joint: a finite element analysis
Meniscal horns are important structures of meniscus, and longitudinal tears of these places could significantly change the load distribution among the knee joint. Few studies concerned the stress concentrated on bones, which may induce the osteonecrosis of subchondral bone. The goal of this study was to construct a finite element (FE) model with high fidelity of the knee joint and evaluate the biomechanical changes of load distribution of components after longitudinal tears of the horns of meniscus. Computed tomography and magnetic resonance images were used to develop the FE model, and two different kinds of simulations, the vertical and the anterior load, mimicking the static stance and slight flexion simulations, were applied after longitudinal tears of the horns of meniscus. Significantly elevated peak compressive and shear stress was observed on the menisci, cartilages, and subchondral bones, and enlarged meniscus extrusion was noticed. Between all the four types of longitudinal tears investigated in this study, longitudinal tears at the posterior horn of the medial meniscus were found to be the most significant. These findings showed that longitudinal tears of the meniscal horns lead to increased magnitude and changed distribution of stress and indicated the important role of posterior horn of medial meniscus. This may contribute to the mechanism between meniscal tears and spontaneous subchondral bone osteonecrosis.
- Open Access
The Size Effect on Forming Quality of Ti–6Al–4V Solid Struts Fabricated via Laser Powder Bed Fusion
Laser powder bed fusion (LPBF) is useful for manufacturing complex structures; however, factors affecting the forming quality have not been clearly researched. This study aimed to clarify the influence of geometric characteristic size on the forming quality of solid struts. Ti–6Al–4V struts with a square section on the side length (0.4 to 1.4 mm) were fabricated with different scan speeds. Micro-computed tomography was used to detect the struts’ profile error and defect distribution. Scanning electron microscopy and light microscopy were used to characterize the samples’ microstructure. Nanoindentation tests were conducted to evaluate the mechanical properties. The experimental results illustrated that geometric characteristic size influenced the struts’ physical characteristics by affecting the cooling condition. This size effect became obvious when the geometric characteristic size and the scan speed were both relatively small. The solid struts with smaller geometric characteristic size had more obvious size error. When the geometric characteristic size was smaller than 1 mm, the nanohardness and elastic modulus increased with the increase in scan speed, and decreased with the decline of the geometric characteristic size. Therefore, a relatively high scan speed should be selected for LPBF—the manufacturing of a porous structure, whose struts have small geometric characteristic size.
Open AccessThe Size Effect on Forming Quality of Ti–6Al–4V Solid Struts Fabricated via Laser Powder Bed Fusion
Laser powder bed fusion (LPBF) is useful for manufacturing complex structures; however, factors affecting the forming quality have not been clearly researched. This study aimed to clarify the influence of geometric characteristic size on the forming quality of solid struts. Ti–6Al–4V struts with a square section on the side length (0.4 to 1.4 mm) were fabricated with different scan speeds. Micro-computed tomography was used to detect the struts’ profile error and defect distribution. Scanning electron microscopy and light microscopy were used to characterize the samples’ microstructure. Nanoindentation tests were conducted to evaluate the mechanical properties. The experimental results illustrated that geometric characteristic size influenced the struts’ physical characteristics by affecting the cooling condition. This size effect became obvious when the geometric characteristic size and the scan speed were both relatively small. The solid struts with smaller geometric characteristic size had more obvious size error. When the geometric characteristic size was smaller than 1 mm, the nanohardness and elastic modulus increased with the increase in scan speed, and decreased with the decline of the geometric characteristic size. Therefore, a relatively high scan speed should be selected for LPBF—the manufacturing of a porous structure, whose struts have small geometric characteristic size.
- Open Access
- 18 June 2018
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 16 (1) , 167
3D printing individualized heel cup for improving the self-reported pain of plantar fasciitis
To explore the therapeutic effect and the biomechanical mechanism of 3D printing individualized heel cup in treating of plantar heel pain. The clinical effect was evaluated by plantar pressure analysis and pain assessment in participants. Its biomechanical mechanism of protecting the plantar heel was explored using finite element simulation. The individualized heel cup could support and protect the osseous structure and soft tissue of plantar heel while walking and jogging, as well as significantly reduce the self-reported pain after being worn for 4 weeks. The nylon heel cup could alter the load concentration of the heel as well as decrease the load affected on plantar fascia and calcaneus bone. It also provided an obvious support for heel pad. To summarize, the 3D printed individualized heel cup can be used as an effective method for the treatment of plantar heel pain.
- 18 June 2018
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 16 (1) , 167
Open Access3D printing individualized heel cup for improving the self-reported pain of plantar fasciitis
To explore the therapeutic effect and the biomechanical mechanism of 3D printing individualized heel cup in treating of plantar heel pain. The clinical effect was evaluated by plantar pressure analysis and pain assessment in participants. Its biomechanical mechanism of protecting the plantar heel was explored using finite element simulation. The individualized heel cup could support and protect the osseous structure and soft tissue of plantar heel while walking and jogging, as well as significantly reduce the self-reported pain after being worn for 4 weeks. The nylon heel cup could alter the load concentration of the heel as well as decrease the load affected on plantar fascia and calcaneus bone. It also provided an obvious support for heel pad. To summarize, the 3D printed individualized heel cup can be used as an effective method for the treatment of plantar heel pain.