NGNing Guo

Ning Guo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ning Guo has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Patellar thickness can critically impact knee joint biomechanics after total knee arthroplasty

    by Ning Guo, Allan Maas, Thomas M. Grupp, Pascal Schütz, Henning Windhagen, William R. Taylor, Seyyed Hamed Hosseini Nasab

    Aims: Despite the potential benefits of an increased moment arm of the knee extensor mechanism with a thicker patellar button in patients undergoing total knee arthroplasty (TKA), many surgeons are reluctant to alter the natural patellar thickness (PTh) during resurfacing. Clinically, this hesitation stems from concerns about straining the extensor apparatus under passive motion exercises and the potential consequences on postoperative joint biomechanics, but also because many patients with a thinner patella experience improved functionality, range of motion, and possibly also reduced soft-tissue pain in the short term postoperatively. However, the biomechanical relationships underlying such short- and long-term consequences remain unexplored. Our aim was to investigate the influence of PTh on knee biomechanics after TKA. Methods: This study used advanced computational modelling techniques to undertake a systematic exploration of the influence of PTh variation on knee joint kinematics, contact mechanics, and muscle and soft-tissue loading patterns during level walking and squatting. Results: Our results indicate that increased PTh efficiency enhances the extensor mechanism, which is consistent with previous studies, but our investigation additionally demonstrates the reduction in tibiofemoral loading conditions, especially at higher flexion angles. Conversely, a thinner patella induces reduced patellofemoral contact forces and pressure, and may offer increased joint range of motion. Conclusion: PTh was found to influence knee biomechanics in clinically relevant ways. A modest increase in thickness improved quadriceps efficiency and reduced tibiofemoral forces by up to ~10%, but also raised patellofemoral pressures by up to ~5 MPa. Conversely, thinner buttons lowered patellofemoral loading and may facilitate early comfort and flexion. These trade-offs were consistent across implant congruency designs, highlighting the need for patient-specific resurfacing strategies. Cite this article: Bone Joint Res 2026;15(5):472–481.

  • Open Access

    Knee contact force alone is insufficient to validate joint mechanics in musculoskeletal models

    by Ning Guo, Allan Maas, Thomas M. Grupp, Adam Trepczynski, Philipp Damm, William R. Taylor, Seyyed Hamed Hosseini Nasab


  • Open Access

    Effect of Constraint Loading on the Lower Limb Muscle Forces in Weightless Treadmill Exercise

    by Ning Guo, Xingyu Fan, Yuting Wu, Zhili Li, Shujuan Liu, Linjie Wang, Jie Yao, Yinghui Li

    Long exposure to the microgravity will lead to muscle atrophy and bone loss. Treadmill exercise could mitigate the musculoskeletal decline. But muscle atrophy remains inevitable. The constraint loading applied on astronauts could affect the muscle force and its atrophy severity. However, the quantitative correlation between constraint loading mode and muscle forces remains unclear. This study aimed to characterize the influence of constraint loading mode on the lower limb muscle forces in weightless treadmill exercise. The muscle forces in the full gait cycle were calculated with the inverse dynamic model of human musculoskeletal system. The calculated muscle forces at gravity were validated with the EMG data. Muscle forces increased at weightlessness compared with those at the earth’s gravity. The increasing percentage from high to low is as follows: biceps femoris, gastrocnemius, soleus, vastus, and rectus femoris, which was in agreement with the muscle atrophy observed in astronauts. The constraint loading mode had an impact on the muscle forces in treadmill exercise and thus could be manipulated to enhance the effect of the muscle training in spaceflight. The findings could provide biomechanical basis for the optimization of treadmill constraint system and training program and improve the countermeasure efficiency in spaceflight.