ATAofei Tian

Aofei Tian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aofei Tian has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development of a Novel 2-DoF Wearable Ankle Angle Sensor With an Adjustable Rotation Center

    by Chaoyang Shi, Yupeng Hao, Aofei Tian, Yinan Zhao, Bo Zhang, Kaifeng Wang

    This paper presents a novel fiber Bragg grating (FBG)-based sensor for precise 2-degree-of-freedom (DoF) ankle angle monitoring. The proposed sensor primarily comprises two symmetric torsion springs, a planar spring, and three FBG-embedded optical fibers. Symmetric torsion springs are employed to measure plantarflexion/dorsiflexion (PF/DF) rotation, while a planar spring targets inversion/eversion (INV/EVE) motion, effectively minimizing cross-axis interference due to their distinct stiffness characteristics. Crucially, the sensor's high in-plane compliance accommodates the physiological shift of the ankle’s rotation center, enabling enhanced wearing comfort. Moreover, a symmetric differential fiber configuration compensates for rotation-axis variations and ensures high measurement accuracy. Structural optimization was conducted to maximize sensitivity and minimize crosstalk. Experimental results demonstrate high sensitivities of 37.09 pm/° (PF/DF) and 224.70 pm/° (INV/EVE) over ±55° and ±23°, respectively. The structural decoupling is validated by a low maximum crosstalk of 3.56%. Furthermore, the sensor maintains accuracy against rotation center offsets, with sensitivity deviations kept below 2.8% under a 2-mm misalignment. Dynamic tests at 50°/s and 300°/s yielded maximum root-mean-square errors (RMSEs) of 2.47° and 1.27° for PF/DF and INV/EVE, respectively. Finally, on-body validation, including seated range-of-motion tests, squat-to-stand exercises, and level walking, confirmed the sensor's ability to capture high-fidelity kinematic profiles for rehabilitation applications.


  • A High-Precision 3-D FBG-Based Force Sensor Utilizing Nested Orthoplanar Springs for Laparoscopic Palpation

    by Yupeng Hao, Aofei Tian, Zeyi Huang, Shumin Lan, Zhengbao Yang, Chengzhi Hu, Chaoyang Shi

    This paper introduces a compact and high-precision three-dimensional fiber Bragg grating-based force sensor for palpation in robotic laparoscopic surgery. An innovative force-sensitive flexure is developed by incorporating two radial-type orthoplanar spring leaves (ROPSLs) nested within a side-type orthoplanar spring structure (SOPSS), resulting in a compact sensor design with a length of 12 mm. Two ROPSLs with a thickness of 0.2 mm are designed to achieve high axial force sensitivity and are connected in series via a coupling shaft to improve bending stiffness. The SOPSS, designated for radial force sensing, incorporates an increased thickness to enhance its axial stiffness. The distinct stiffness characteristic between ROPSLs and SOPSS results in a balanced 3-D force sensitivity and minimized crosstalk, facilitating improved accuracy. The performance evaluation and optimization were conducted employing finite element analysis. Calibration experiments demonstrated excellent resolutions of 1.2 mN, 1.1 mN, and 2.5 mN for Fx, Fy, and Fz, respectively, as well as superior linearity with the maximum error of 1.35%. Dynamic loading experiments validated the sensor’s high measurement precision, with average root mean square error (RMSE) values of 15 mN (Fx), 16 mN (Fy), and 72 mN (Fz). Finally, palpation experiments on silicone phantoms and ex vivo porcine tissues successfully confirmed the sensor’s efficacy in differentiating tumor tissue from normal tissue.


  • Design and Validation of a High-Sensitivity FBG-Based Triaxial Force Sensor With Serially Configured Flexures for Percutaneous Puncture

    by Peichen Xie, Yupeng Hao, Aofei Tian, Bo Zhang, Chengzhi Hu, Chaoyang Shi

    This article introduces an innovative fiber Bragg grating (FBG)-based triaxial force sensor with high sensitivity for percutaneous puncture applications. The proposed sensor employs the serially configured axial and radial force-sensitive flexures, incorporating tightly suspended optical fibers inscribed with FBG elements. Leveraging the rigid-body replacement method, the designed flexures exhibit selective sensitivities to axial and radial loads, enabling low-coupling triaxial force sensing. The axial force-sensitive flexure combined a semi-bridge mechanism with symmetrical L-shaped levers, amplifying output force while reversing deformation direction. This design maintains the measuring fiber in a purely tensile state, obviating the need for preload adhesion, thereby streamlining assembly and augmenting fiber durability. Finite element method (FEM)-based simulation and structural parameter optimization have been implemented to further enhance the sensitivity. The sensor prototype has been calibrated employing a nonlinear decoupling algorithm based on a backpropagation neural network (BPNN), achieving high resolutions of 2.6 mN within the axial range of 8 N and 0.25 mN within the radial range of ±1 N, with the crosstalk limited to 4.36%. Puncture experiments demonstrated a root mean square error (RMSE) of 3-D resultant forces not exceeding 12.3 mN on ex-vivo tissues, validating the sensor's efficacy and potential in robotic puncture surgery.


  • Wearable Fiber Bragg Grating Sensors for Physiological Signal and Body Motion Monitoring: A Review

    by Feng Zhang, Yupeng Hao, Aofei Tian, Zhengbao Yang, Bo Zhang, Toshio Fukuda, Chaoyang Shi

    Wearable sensors play a crucial role in real-time physiological parameters and body motion monitoring, enabling early detection and prevention of potential health issues. However, conventional electrical sensors are susceptible to electromagnetic interference (EMI), limiting their application in magnetic resonance imaging (MRI), electrosurgery, and humid environments. Optical wearable devices based on fiber Bragg gratings (FBGs) offer distinct advantages such as miniaturization, immunity to EMI, high sensitivity, and multiplexing capabilities, making them promising for healthcare applications. Nevertheless, FBG sensors face challenges such as susceptibility to breakage and cross-sensitivity to temperature and multiple strain signals, creating obstacles in expanding strain monitoring range, reducing monitoring errors, and improving wear resistance. This review comprehensively introduces the latest advancements, technical challenges, and potential solutions associated with wearable FBG sensing devices for detecting physiological signals and body motion, particularly emphasizing their applications in monitoring small- and large-strain body movements. This article focuses on the sensing characteristics of FBG units in both soft and rigid substrate materials and tracks the advancement in sensing structure optimization for enhanced measurement capabilities. Future directions and opportunities for technological improvement in this field are also discussed.