Qin Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qin Li has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Falk Poenisch
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
1 shared publication Gang Liu
Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
1 shared publication- Gang Wu
Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
1 shared publication - Heng Li
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
1 shared publication - Hongyuan Liu
Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
1 shared publication - Kunyu Yang
Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
1 shared publication
Latest Publications
- Open Access
- 19 July 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-9
Statistical evaluation of worst-case robust optimization intensity-modulated proton therapy plans using an exhaustive sampling approach
To assess the worst-case robust optimization IMPT plans with setup and range uncertainties and to test the hypothesis that the worst-case robust optimization strategies could cover most possible setup and range uncertainties in the real scenarios. We analyzed the nominal and worst-case robust optimization IMPT plans of seven patients with head and neck cancer patients. To take uncertainties into account for the dose calculation, we performed a comprehensive simulation in which the dose was recalculated 625 times per given plan using Gaussian systematic setup and proton range uncertainties. Subsequently, based on the simulation results, we calculated the target coverage in all perturbation scenarios, as well as the ratios of target coverage located within the threshold of eight worst-case scenarios. We set the criteria for the optimized plan to be the ratios of 1) the dose delivered to 95% (D95%) of clinical target volumes 1 and 2 (CTV1 and CTV2) above 95% of the prescribed dose, and 2) the D95% of clinical target volume 3 (CTV3) above 90% of the prescribed dose in worst-case situations. The probability that the perturbed-dose indices of the CTVs in each scenario were within the worst-case scenario limits ranged from 89.51 to 91.22% for both the nominal and worst-case robust optimization IMPT plans. A quartile analysis showed that the selective robust optimization IMPT plans all had higher D95% values for CTV1, CTV2, and CTV3 than did the nominal IMPT plans. The worst-case strategy for robust optimization is adequately models and covers most of the setup and range uncertainties for the IMPT treatment of head and neck patients in our center.
- 19 July 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-9
Open AccessStatistical evaluation of worst-case robust optimization intensity-modulated proton therapy plans using an exhaustive sampling approach
To assess the worst-case robust optimization IMPT plans with setup and range uncertainties and to test the hypothesis that the worst-case robust optimization strategies could cover most possible setup and range uncertainties in the real scenarios. We analyzed the nominal and worst-case robust optimization IMPT plans of seven patients with head and neck cancer patients. To take uncertainties into account for the dose calculation, we performed a comprehensive simulation in which the dose was recalculated 625 times per given plan using Gaussian systematic setup and proton range uncertainties. Subsequently, based on the simulation results, we calculated the target coverage in all perturbation scenarios, as well as the ratios of target coverage located within the threshold of eight worst-case scenarios. We set the criteria for the optimized plan to be the ratios of 1) the dose delivered to 95% (D95%) of clinical target volumes 1 and 2 (CTV1 and CTV2) above 95% of the prescribed dose, and 2) the D95% of clinical target volume 3 (CTV3) above 90% of the prescribed dose in worst-case situations. The probability that the perturbed-dose indices of the CTVs in each scenario were within the worst-case scenario limits ranged from 89.51 to 91.22% for both the nominal and worst-case robust optimization IMPT plans. A quartile analysis showed that the selective robust optimization IMPT plans all had higher D95% values for CTV1, CTV2, and CTV3 than did the nominal IMPT plans. The worst-case strategy for robust optimization is adequately models and covers most of the setup and range uncertainties for the IMPT treatment of head and neck patients in our center.
- Open Access
- 7 September 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-11
Target margin design for real-time lung tumor tracking stereotactic body radiation therapy using CyberKnife Xsight Lung Tracking System
The objective of this study is to quantify the clinical accuracy of the Cyberknife Xsight Lung Tracking System (XLTS) in our center and calculate the PTV margin of XLTS treated lung tumors. Data from the treatment log files of 22 lung cancer patients treated with the CyberKnife XLTS were analyzed and the PTV margin was calculated. Segmentation, deformation, correlation, prediction and targeting errors were calculated from the log files of XLTS treatments. Two different methods were used to calculate anisotropic treatment margin. The relationships between tumor motion ranges and the correlation and prediction errors were also analyzed. Based on our estimation of a 4 mm global margin, 95% coverage in the S-I direction and 100% coverage in the L-R and A-P directions were obtained. Strong correlations between tumor motion range and the standard deviation (SD) of correlation and prediction errors were also found. Tumor position motion caused by respiration can be compensated using the Xsight Lung Tracking System. We found total tracking errors to be less than 4 mm in all three directions. This result could provide a reference for the selection of PTV margin for treatment with the CyberKnife XLTS.
- 7 September 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-11
Open AccessTarget margin design for real-time lung tumor tracking stereotactic body radiation therapy using CyberKnife Xsight Lung Tracking System
The objective of this study is to quantify the clinical accuracy of the Cyberknife Xsight Lung Tracking System (XLTS) in our center and calculate the PTV margin of XLTS treated lung tumors. Data from the treatment log files of 22 lung cancer patients treated with the CyberKnife XLTS were analyzed and the PTV margin was calculated. Segmentation, deformation, correlation, prediction and targeting errors were calculated from the log files of XLTS treatments. Two different methods were used to calculate anisotropic treatment margin. The relationships between tumor motion ranges and the correlation and prediction errors were also analyzed. Based on our estimation of a 4 mm global margin, 95% coverage in the S-I direction and 100% coverage in the L-R and A-P directions were obtained. Strong correlations between tumor motion range and the standard deviation (SD) of correlation and prediction errors were also found. Tumor position motion caused by respiration can be compensated using the Xsight Lung Tracking System. We found total tracking errors to be less than 4 mm in all three directions. This result could provide a reference for the selection of PTV margin for treatment with the CyberKnife XLTS.