Michael Jüptner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Jüptner has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Maaz Zuhayra
Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Campus Kiel, Karl Lennert Cancer Center North, Kiel, Germany
5 shared publications - Yi Zhao
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
5 shared publications - Alexander Helm
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
3 shared publications - Ammar Alfteimi
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
3 shared publications - Ulf Lützen
Department of Nuclear Medicine, Molecular Diagnostic, Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Camous Kiel, Karl Lennert Cancer Center North, Kiel, Germany
3 shared publications - Carsten Maik Naumann
Department of Urology and Pediatric Urology, University Hospital Schleswig Holstein, Kiel, Germany
2 shared publications
Latest Publications
- Open Access
- 17 February 2026
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 11 (1)
Increasing the activity output and optimization of automated radiosynthesis [68Ga]Ga-DOTATATE, [68Ga]Ga-Pentixafor, and [68Ga]Ga-FAPI-64 using two [68Ge]Ge/[68Ga]Ga iThemba generators in series
Background: The rapidly increasing clinical demand for 68 Ga-labelled radiopharmaceuticals continues to challenge current production capacities, particularly in high-throughput nuclear medicine departments. Although dual-generator concepts have previously been explored, all reported approaches to date have required either pre-purification, fractionated elution, or additional cartridge-based concentration steps, which add complexity and limit routine clinical implementation. In the present study, we report for the first time a fully automated, GMP-compliant synthesis protocol using two iThemba 68 Ge/ 68 Ga generators connected in series on a standard EasyOne module applicable to three clinically relevant tracers. We successfully established robust GMP production of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-FAPI-46, and [ 68 Ga]Ga-PentixaFor without any pre-purification or fractional elution. A key mechanistic finding of this work is the critical role of direct ascorbic acid addition to the reaction medium, which effectively suppresses radiolysis and metal-ion interference under high-activity conditions. Results: We established a Good Manufacturing Practice (GMP)-compliant, fully automated synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46 using two 68 Ge/ 68 Ga iThemba generators connected in series, of which the older generator is replaced with a new one every 6 months. This configuration enabled elution of maximum activity of 3750 MBq and minimum activity of 2345 MBq, exceeding the elution activity achieved with a single generator by 2300 and 901 MBq respectively. The corrected yield of the labelled products was 91 ± 5% (72 ± 5% non-decay corrected). The additional activity of the labeled products obtained through the two generator configuration enables the examination of 2–4 additional patients per batch and thus resulting in significant cost savings. The direct addition of ascorbic acid to the reaction medium was essential, as it suppressed radiolysis and minimized the impact of metallic impurities. This innovation enabled reproducible labeling without pre-purification, which has not previously been demonstrated with SnO 2 -based generators. Conclusions: Dual-generator elution on the EasyOne module without modification of Trasis single-use cassettes provides a robust and scalable approach for high-yield production of 68 Ga radiopharmaceuticals. The integration of series-connected iThemba generators with in-situ radiolysis control by ascorbic acid ensures consistent GMP-compliant synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46. This method improves production efficiency, reduces costs, and expands clinical accessibility.
- 17 February 2026
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 11 (1)
Open AccessIncreasing the activity output and optimization of automated radiosynthesis [68Ga]Ga-DOTATATE, [68Ga]Ga-Pentixafor, and [68Ga]Ga-FAPI-64 using two [68Ge]Ge/[68Ga]Ga iThemba generators in series
Background: The rapidly increasing clinical demand for 68 Ga-labelled radiopharmaceuticals continues to challenge current production capacities, particularly in high-throughput nuclear medicine departments. Although dual-generator concepts have previously been explored, all reported approaches to date have required either pre-purification, fractionated elution, or additional cartridge-based concentration steps, which add complexity and limit routine clinical implementation. In the present study, we report for the first time a fully automated, GMP-compliant synthesis protocol using two iThemba 68 Ge/ 68 Ga generators connected in series on a standard EasyOne module applicable to three clinically relevant tracers. We successfully established robust GMP production of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-FAPI-46, and [ 68 Ga]Ga-PentixaFor without any pre-purification or fractional elution. A key mechanistic finding of this work is the critical role of direct ascorbic acid addition to the reaction medium, which effectively suppresses radiolysis and metal-ion interference under high-activity conditions. Results: We established a Good Manufacturing Practice (GMP)-compliant, fully automated synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46 using two 68 Ge/ 68 Ga iThemba generators connected in series, of which the older generator is replaced with a new one every 6 months. This configuration enabled elution of maximum activity of 3750 MBq and minimum activity of 2345 MBq, exceeding the elution activity achieved with a single generator by 2300 and 901 MBq respectively. The corrected yield of the labelled products was 91 ± 5% (72 ± 5% non-decay corrected). The additional activity of the labeled products obtained through the two generator configuration enables the examination of 2–4 additional patients per batch and thus resulting in significant cost savings. The direct addition of ascorbic acid to the reaction medium was essential, as it suppressed radiolysis and minimized the impact of metallic impurities. This innovation enabled reproducible labeling without pre-purification, which has not previously been demonstrated with SnO 2 -based generators. Conclusions: Dual-generator elution on the EasyOne module without modification of Trasis single-use cassettes provides a robust and scalable approach for high-yield production of 68 Ga radiopharmaceuticals. The integration of series-connected iThemba generators with in-situ radiolysis control by ascorbic acid ensures consistent GMP-compliant synthesis of [ 68 Ga]Ga-DOTATATE, [ 68 Ga]Ga-Pentixafor, and [ 68 Ga]Ga-FAPI-46. This method improves production efficiency, reduces costs, and expands clinical accessibility.
- Open Access
- 29 July 2022
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 7 (1) , 1-16
Automated synthesis of [68Ga]Ga-FAPI-46 without pre-purification of the generator eluate on three common synthesis modules and two generator types
Background: The recent development of quinoline-based radiotracers, which act as fibroblast activation protein inhibitors (FAPIs), has shown promising preclinical and clinical advantages. [68Ga]Ga-FAPI-46 is a new radiotracer for in vivo detection of the fibroblast activation protein by positron emission tomography (PET). Recently, the automated synthesis of [68Ga]Ga-FAPI-46 was reported based on pre-concentration and purification of the generator eluate by using a cation exchange-cartridge. Our aim was to simplify the synthesis and shorten the automated synthesis of [68Ga]Ga-FAPI-46 to make it accessible and thus even more attractive to a broader clinical and scientific community. Results: We developed and evaluated the GMP compliant automatic synthesis of [68Ga]Ga-FAPI-46 using two different 68Ge/68Ga generators (an Eckert & Ziegler, GalliaPharm generator, 1.85 GBq/50 mCi and an iThemba generator, 1.85 GBq/50 mCi) Somerset West, South Africa) and three different commercial and customized systems: the EasyOne module from Trasis; the GaSy module from Synthra with a customized synthesis template and a customized single use cassette. Additionally, the automatic synthesis of [68Ga]Ga-FAPI-46 was established on a GallElut synthesis module from Scintomics with fixed tubing. Conclusions: Independent of the synthesis modules or the generators employed we were able to complete the synthesis of [68Ga]Ga-FAPI-46 in 12 min including the process of purification and formulation. In all cases, the final products showed more than 99.5% chemical purity and the radiochemical yield reached around 92.5% (decay corrected). All quality control parameters (e.g. sterility, stability and radiochemical purity) were conform to the European Pharmacopoeia.
- 29 July 2022
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 7 (1) , 1-16
Open AccessAutomated synthesis of [68Ga]Ga-FAPI-46 without pre-purification of the generator eluate on three common synthesis modules and two generator types
Background: The recent development of quinoline-based radiotracers, which act as fibroblast activation protein inhibitors (FAPIs), has shown promising preclinical and clinical advantages. [68Ga]Ga-FAPI-46 is a new radiotracer for in vivo detection of the fibroblast activation protein by positron emission tomography (PET). Recently, the automated synthesis of [68Ga]Ga-FAPI-46 was reported based on pre-concentration and purification of the generator eluate by using a cation exchange-cartridge. Our aim was to simplify the synthesis and shorten the automated synthesis of [68Ga]Ga-FAPI-46 to make it accessible and thus even more attractive to a broader clinical and scientific community. Results: We developed and evaluated the GMP compliant automatic synthesis of [68Ga]Ga-FAPI-46 using two different 68Ge/68Ga generators (an Eckert & Ziegler, GalliaPharm generator, 1.85 GBq/50 mCi and an iThemba generator, 1.85 GBq/50 mCi) Somerset West, South Africa) and three different commercial and customized systems: the EasyOne module from Trasis; the GaSy module from Synthra with a customized synthesis template and a customized single use cassette. Additionally, the automatic synthesis of [68Ga]Ga-FAPI-46 was established on a GallElut synthesis module from Scintomics with fixed tubing. Conclusions: Independent of the synthesis modules or the generators employed we were able to complete the synthesis of [68Ga]Ga-FAPI-46 in 12 min including the process of purification and formulation. In all cases, the final products showed more than 99.5% chemical purity and the radiochemical yield reached around 92.5% (decay corrected). All quality control parameters (e.g. sterility, stability and radiochemical purity) were conform to the European Pharmacopoeia.
- Open Access
- 17 March 2022
- Published by Elsevier in Physica Medica
- Vol. 96, 157-165
A simple, reliable and accurate approach for assessing [131I]-capsule activity leading to significant reduction of radiation exposure of medical staff during radioiodine therapy
- 17 March 2022
- Published by Elsevier in Physica Medica
- Vol. 96, 157-165
Open AccessA simple, reliable and accurate approach for assessing [131I]-capsule activity leading to significant reduction of radiation exposure of medical staff during radioiodine therapy
- Open Access
- 7 September 2016
- Published by Springer Nature in Cancer Imaging
- Vol. 16 (1) , 1-16
A study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure
Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.
- 7 September 2016
- Published by Springer Nature in Cancer Imaging
- Vol. 16 (1) , 1-16
Open AccessA study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure
Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.
- Open Access
- 2 August 2016
- Published by Springer Nature in BMC Urology
- Vol. 16 (1) , 1-10
10-Year experience regarding the reliability and morbidity of radio guided lymph node biopsy in penile cancer patients and the associated radiation exposure of medical staff in this procedure
The guidelines of the European Association of Urologists (EAU), of the German Society of Nuclear Medicine (DGN), and the European Society for Medical Oncology (ESMO) recommend sentinel lymph node biopsy (SLNB) for lymph node staging in penile cancer with non-palpable inguinal lymph nodes as one diagnostic method. Despite this, the method is neither widely nor regularly applied in Germany – the same applies to many other countries, which may be due to insecurity in dealing with open radioactive tracers. This study aims to assess the reliability and morbidity of this method, as well as the associated radioactive burden for clinical staff. Between 2006 and 2016, 34 patients with an invasive penile carcinoma and inconspicuous inguinal lymph node status underwent SLNB in 57 groins after application of a radiotracer (Tc-99 m nanocolloid). We collected the results prospectively. The reliability of the method was assessed by determining the false-negative rate. In addition, we evaluated complication rates and determined the radioactive burden for the clinical staff both pre- and intraoperatively. SLNB was performed in 34 patients with penile cancer with non-palpable inguinal lymph nodes in 57 groins. In two patients inguinal lymph node metastases were detected by means of SLNB. In one patient recurrent inguinal lymph node disease was found after negative SLNB in both groins. Thus, the false negative rate was 3.13 % per patient (1/32 patients) and 3.51 % per groin (2/57 groins). The morbidity rate was 2.94 % per patient (1/34 patients) and 1.75 % per groin (1/57 groins). Radiation exposure for the clinical staff during this procedure was low at a maximum of ca. four μSV per intervention. SLNB is a reliable method with low morbidity that is associated with a low radiation burden for clinical staff. Due to the enhanced methodological and logistic demands, this intervention should be performed in specialized centres and in an interdisciplinary approach.
- 2 August 2016
- Published by Springer Nature in BMC Urology
- Vol. 16 (1) , 1-10
Open Access10-Year experience regarding the reliability and morbidity of radio guided lymph node biopsy in penile cancer patients and the associated radiation exposure of medical staff in this procedure
The guidelines of the European Association of Urologists (EAU), of the German Society of Nuclear Medicine (DGN), and the European Society for Medical Oncology (ESMO) recommend sentinel lymph node biopsy (SLNB) for lymph node staging in penile cancer with non-palpable inguinal lymph nodes as one diagnostic method. Despite this, the method is neither widely nor regularly applied in Germany – the same applies to many other countries, which may be due to insecurity in dealing with open radioactive tracers. This study aims to assess the reliability and morbidity of this method, as well as the associated radioactive burden for clinical staff. Between 2006 and 2016, 34 patients with an invasive penile carcinoma and inconspicuous inguinal lymph node status underwent SLNB in 57 groins after application of a radiotracer (Tc-99 m nanocolloid). We collected the results prospectively. The reliability of the method was assessed by determining the false-negative rate. In addition, we evaluated complication rates and determined the radioactive burden for the clinical staff both pre- and intraoperatively. SLNB was performed in 34 patients with penile cancer with non-palpable inguinal lymph nodes in 57 groins. In two patients inguinal lymph node metastases were detected by means of SLNB. In one patient recurrent inguinal lymph node disease was found after negative SLNB in both groins. Thus, the false negative rate was 3.13 % per patient (1/32 patients) and 3.51 % per groin (2/57 groins). The morbidity rate was 2.94 % per patient (1/34 patients) and 1.75 % per groin (1/57 groins). Radiation exposure for the clinical staff during this procedure was low at a maximum of ca. four μSV per intervention. SLNB is a reliable method with low morbidity that is associated with a low radiation burden for clinical staff. Due to the enhanced methodological and logistic demands, this intervention should be performed in specialized centres and in an interdisciplinary approach.