J N K Carlson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
J N K Carlson has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jong Min Park
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
4 shared publications - Jung-In Kim
Department of Radiation Oncology Seoul National University Hospital Seoul Republic of Korea
3 shared publications - Hong-Gyun Wu
Department of Radiation Oncology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
2 shared publications - Jin Ho Kim
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
2 shared publications - Kyubo Kim
Department of Radiation Oncology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, South Korea
2 shared publications - Chang Heon Choi
Department of Radiation Oncology Seoul National University Hospital Seoul Republic of Korea
1 shared publication
Latest Publications
- 8 December 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1070) , 20160652
Quality of tri-Co-60 MR-IGRT treatment plans in comparison with VMAT treatment plans for spine SABR
Objective: To investigate the plan quality of tri-Co-60 intensity-modulated radiation therapy (IMRT) plans for spine stereotactic ablative radiotherapy (SABR). Methods: A total of 20 patients with spine metastasis were retrospectively selected. For each patient, a tri-Co-60 IMRT plan and a volumetric-modulated arc therapy (VMAT) plan were generated. The spinal cords were defined based on MR images for the tri-Co-60 IMRT, while isotropic 1-mm margins were added to the spinal cords for the VMAT plans. The VMAT plans were generated with 10-MV flattening filter-free photon beams of TrueBeam STx™ (Varian Medical Systems, Palo Alto, CA), while the tri-Co-60 IMRT plans were generated with the ViewRay™ system (ViewRay inc., Cleveland, OH). The initial prescription dose was 18 Gy (1 fraction). If the tolerance dose of the spinal cord was not met, the prescription dose was reduced until the spinal cord tolerance dose was satisfied. Results: The mean dose to the target volumes, conformity index and homogeneity index of the VMAT and tri-Co-60 IMRT were 17.8 ± 0.8 vs 13.7 ± 3.9 Gy, 0.85 ± 0.20 vs 1.58 ± 1.29 and 0.09 ± 0.04 vs 0.24 ± 0.19, respectively. The integral doses and beam-on times were 16,570 ± 1768 vs 22,087 ± 2.986 Gy cm3 and 3.95 ± 1.13 vs 48.82 ± 10.44 min, respectively. Conclusion: The tri-Co-60 IMRT seems inappropriate for spine SABR compared with VMAT. Advances in knowledge: For spine SABR, the tri-Co-60 IMRT is inappropriate owing to the large penumbra, large leaf width and low dose rate of the ViewRay system.
- 8 December 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1070) , 20160652
Quality of tri-Co-60 MR-IGRT treatment plans in comparison with VMAT treatment plans for spine SABR
Objective: To investigate the plan quality of tri-Co-60 intensity-modulated radiation therapy (IMRT) plans for spine stereotactic ablative radiotherapy (SABR). Methods: A total of 20 patients with spine metastasis were retrospectively selected. For each patient, a tri-Co-60 IMRT plan and a volumetric-modulated arc therapy (VMAT) plan were generated. The spinal cords were defined based on MR images for the tri-Co-60 IMRT, while isotropic 1-mm margins were added to the spinal cords for the VMAT plans. The VMAT plans were generated with 10-MV flattening filter-free photon beams of TrueBeam STx™ (Varian Medical Systems, Palo Alto, CA), while the tri-Co-60 IMRT plans were generated with the ViewRay™ system (ViewRay inc., Cleveland, OH). The initial prescription dose was 18 Gy (1 fraction). If the tolerance dose of the spinal cord was not met, the prescription dose was reduced until the spinal cord tolerance dose was satisfied. Results: The mean dose to the target volumes, conformity index and homogeneity index of the VMAT and tri-Co-60 IMRT were 17.8 ± 0.8 vs 13.7 ± 3.9 Gy, 0.85 ± 0.20 vs 1.58 ± 1.29 and 0.09 ± 0.04 vs 0.24 ± 0.19, respectively. The integral doses and beam-on times were 16,570 ± 1768 vs 22,087 ± 2.986 Gy cm3 and 3.95 ± 1.13 vs 48.82 ± 10.44 min, respectively. Conclusion: The tri-Co-60 IMRT seems inappropriate for spine SABR compared with VMAT. Advances in knowledge: For spine SABR, the tri-Co-60 IMRT is inappropriate owing to the large penumbra, large leaf width and low dose rate of the ViewRay system.
- 1 November 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1055) , 20140862
Dosimetric effects of roll rotational setup errors on lung stereotactic ablative radiotherapy using volumetric modulated arc therapy
To evaluate the dosimetric effects of roll-rotational setup errors of stereotactic ablative radiotherapy (SABR) for lung cancer using volumetric modulated arc therapy (VMAT). A total of 23 lung SABR cases were evaluated retrospectively. Each of the planning CT images was intentionally rotated by ±1°, ±2° and ±3°. After that, to simulate the translational couch correction, rotated CT images were moved along the x, y and z axis to match the centroid of the target volume in the rotated CT images with that in the original CT images. The differences in D95% and V100% of the target volume, D0.35cc of spinal cord, D0.35cc and D5cc of oesophagus and V20Gy of lung between the original and the rotated CT images were calculated. The average differences in D95% and V100% of target volume, D0.35cc of spinal cord, D0.35cc and D5cc of oesophagus and V20Gy of lung were −0.3% ± 0.4% and −0.7% ± 2.4%, 1.6 ± 27.9 cGy, −1.6 ± 37.6 cGy, 15.9 ± 25.3 cGy and 0.0% ± 0.1%, respectively. The dosimetric changes in organs at risk (OARs) near the target volume were sometimes considerable due to roll-rotational setup errors, despite the translational correction, and those were patient specific. In the case of coplanar VMAT for lung SABR, dosimetric changes to the target volume due to roll-rotational setup errors could be compensated by translational correction, whereas those to the OARs could not in some cases. Roll-rotational setup errors would increase the dose to OARs despite the translational correction.
- 1 November 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1055) , 20140862
Dosimetric effects of roll rotational setup errors on lung stereotactic ablative radiotherapy using volumetric modulated arc therapy
To evaluate the dosimetric effects of roll-rotational setup errors of stereotactic ablative radiotherapy (SABR) for lung cancer using volumetric modulated arc therapy (VMAT). A total of 23 lung SABR cases were evaluated retrospectively. Each of the planning CT images was intentionally rotated by ±1°, ±2° and ±3°. After that, to simulate the translational couch correction, rotated CT images were moved along the x, y and z axis to match the centroid of the target volume in the rotated CT images with that in the original CT images. The differences in D95% and V100% of the target volume, D0.35cc of spinal cord, D0.35cc and D5cc of oesophagus and V20Gy of lung between the original and the rotated CT images were calculated. The average differences in D95% and V100% of target volume, D0.35cc of spinal cord, D0.35cc and D5cc of oesophagus and V20Gy of lung were −0.3% ± 0.4% and −0.7% ± 2.4%, 1.6 ± 27.9 cGy, −1.6 ± 37.6 cGy, 15.9 ± 25.3 cGy and 0.0% ± 0.1%, respectively. The dosimetric changes in organs at risk (OARs) near the target volume were sometimes considerable due to roll-rotational setup errors, despite the translational correction, and those were patient specific. In the case of coplanar VMAT for lung SABR, dosimetric changes to the target volume due to roll-rotational setup errors could be compensated by translational correction, whereas those to the OARs could not in some cases. Roll-rotational setup errors would increase the dose to OARs despite the translational correction.
- 1 August 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1052) , 20140536
Evaluation of a commercial orthopaedic metal artefact reduction tool in radiation therapy of patients with head and neck cancer
To assess the image quality and dosimetric effects of the Philips orthopaedic metal artefact reduction (OMAR) (Philips Healthcare System, Cleveland, OH) function for reducing metal artefacts on CT images of head and neck (H&N) patients. 11 patients and a custom-built phantom with metal bead inserts (alumina, titanium, zirconia and chrome) were scanned. The image was reconstructed in two ways: with and without OMAR (OMAR and non-OMAR image). The mean and standard deviation values of CT Hounsfield unit (HU) for selected regions of interest of each case were investigated for both images. Volumetric modulated arc therapy plans were generated for all cases. Gamma analysis of each dose distribution pair in the patient (1%/1 mm criteria) and phantom (2%/2 mm and 3%/3 mm criteria) images was performed. The film measurements in phantom for two metal beads were conducted for evaluating the calculated dose on both OMAR and non-OMAR images. In the OMAR images, noise values were generally reduced, and the mean HU became closer to the reference value (measured from patients without metal implants) in both patient and phantom cases. Although dosimetric difference was insignificant for the eight closed-mouth patients (γ = 99.4 ± 0.5%), there was a large discrepancy in dosimetric calculation between OMAR and non-OMAR images for the three opened-mouth patients (γ = 91.1%, 94.8% and 96.6%). Moreover, the calculated dose on the OMAR image is closer to the real delivered dose on a radiochromic film than was the dose from the non-OMAR image. The OMAR algorithm increases the accuracy of CT HU and reduces the noise such that the entire radiation treatment planning process can be improved, especially for contouring and segmentation. OMAR reconstruction is appropriate for the radiotherapy planning process of H&N patients, particularly of patients who use a bite block.
- 1 August 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1052) , 20140536
Evaluation of a commercial orthopaedic metal artefact reduction tool in radiation therapy of patients with head and neck cancer
To assess the image quality and dosimetric effects of the Philips orthopaedic metal artefact reduction (OMAR) (Philips Healthcare System, Cleveland, OH) function for reducing metal artefacts on CT images of head and neck (H&N) patients. 11 patients and a custom-built phantom with metal bead inserts (alumina, titanium, zirconia and chrome) were scanned. The image was reconstructed in two ways: with and without OMAR (OMAR and non-OMAR image). The mean and standard deviation values of CT Hounsfield unit (HU) for selected regions of interest of each case were investigated for both images. Volumetric modulated arc therapy plans were generated for all cases. Gamma analysis of each dose distribution pair in the patient (1%/1 mm criteria) and phantom (2%/2 mm and 3%/3 mm criteria) images was performed. The film measurements in phantom for two metal beads were conducted for evaluating the calculated dose on both OMAR and non-OMAR images. In the OMAR images, noise values were generally reduced, and the mean HU became closer to the reference value (measured from patients without metal implants) in both patient and phantom cases. Although dosimetric difference was insignificant for the eight closed-mouth patients (γ = 99.4 ± 0.5%), there was a large discrepancy in dosimetric calculation between OMAR and non-OMAR images for the three opened-mouth patients (γ = 91.1%, 94.8% and 96.6%). Moreover, the calculated dose on the OMAR image is closer to the real delivered dose on a radiochromic film than was the dose from the non-OMAR image. The OMAR algorithm increases the accuracy of CT HU and reduces the noise such that the entire radiation treatment planning process can be improved, especially for contouring and segmentation. OMAR reconstruction is appropriate for the radiotherapy planning process of H&N patients, particularly of patients who use a bite block.
- 1 May 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1049) , 20140698
The effect of MLC speed and acceleration on the plan delivery accuracy of VMAT
To determine a new metric utilizing multileaf collimator (MLC) speeds and accelerations to predict plan delivery accuracy of volumetric modulated arc therapy (VMAT). To verify VMAT delivery accuracy, gamma evaluations, analysis of mechanical parameter difference between plans and log files, and analysis of changes in dose-volumetric parameters between plans and plans reconstructed with log files were performed with 40 VMAT plans. The average proportion of leaf speeds ranging from l to h cm s(-1) (Sl-h and l-h = 0-0.4, 0.4-0.8, 0.8-1.2, 1.2-1.6 and 1.6-2.0), mean and standard deviation of MLC speeds were calculated for each VMAT plan. The same was carried out for accelerations in centimetre per second squared (Al-h and l-h = 0-4, 4-8, 8-12, 12-16 and 16-20). The correlations of those indicators to plan delivery accuracy were analysed with Spearman's correlation coefficient (rs). The S1.2-1.6 and mean acceleration of MLCs showed generally higher correlations to plan delivery accuracy than did others. The highest rs values were observed between S1.2-1.6 and global 1%/2 mm (rs = -0.698 with p < 0.001) as well as mean acceleration and global 1%/2 mm (rs = -0.650 with p < 0.001). As the proportion of MLC speeds and accelerations >0.4 and 4 cm s(-2) increased, the plan delivery accuracy of VMAT decreased. The variations in MLC speeds and accelerations showed considerable correlations to VMAT delivery accuracy. As the MLC speeds and accelerations increased, VMAT delivery accuracy reduced.
- 1 May 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1049) , 20140698
The effect of MLC speed and acceleration on the plan delivery accuracy of VMAT
To determine a new metric utilizing multileaf collimator (MLC) speeds and accelerations to predict plan delivery accuracy of volumetric modulated arc therapy (VMAT). To verify VMAT delivery accuracy, gamma evaluations, analysis of mechanical parameter difference between plans and log files, and analysis of changes in dose-volumetric parameters between plans and plans reconstructed with log files were performed with 40 VMAT plans. The average proportion of leaf speeds ranging from l to h cm s(-1) (Sl-h and l-h = 0-0.4, 0.4-0.8, 0.8-1.2, 1.2-1.6 and 1.6-2.0), mean and standard deviation of MLC speeds were calculated for each VMAT plan. The same was carried out for accelerations in centimetre per second squared (Al-h and l-h = 0-4, 4-8, 8-12, 12-16 and 16-20). The correlations of those indicators to plan delivery accuracy were analysed with Spearman's correlation coefficient (rs). The S1.2-1.6 and mean acceleration of MLCs showed generally higher correlations to plan delivery accuracy than did others. The highest rs values were observed between S1.2-1.6 and global 1%/2 mm (rs = -0.698 with p < 0.001) as well as mean acceleration and global 1%/2 mm (rs = -0.650 with p < 0.001). As the proportion of MLC speeds and accelerations >0.4 and 4 cm s(-2) increased, the plan delivery accuracy of VMAT decreased. The variations in MLC speeds and accelerations showed considerable correlations to VMAT delivery accuracy. As the MLC speeds and accelerations increased, VMAT delivery accuracy reduced.