YWYuko Wada

Yuko Wada

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuko Wada has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Midterm results of aneurysmorrhaphy for enlargement after endovascular aneurysm repair

    by Yuko Wada, Yuki Takagi, Shuji Chino, Tohru Mikoshiba, Haruki Tanaka, Hajime Ichimura, Noburo Ohashi, Tatsuichiro Seto

  • Nontraumatic Proximal Ulnar Artery Pseudoaneurysm Mimicking a Soft Tissue Tumor in Image Modality

    by Hiromu Kehara, Yuko Wada, Daisuke Fukui, Kunihiko Shingu, Tatsuichiro Seto, Kenji Okada


  • Open Access

    Pseudoaneurysm of graft–graft anastomosis of a hand-sewn branched graft: a case report

    by Toshihito Gomibuchi, Tamaki Takano, Yuko Wada, Takamitsu Terasaki, Tatsuichiro Seto, Daisuke Fukui

    Pseudoaneurysm of graft–graft anastomosis is an extremely rare but potentially fatal complication after thoracic aorta replacement with a prosthetic graft. We report a case of pseudoaneurysm at the graft–graft anastomosis of a hand-sewn branched graft. A 65-year-old man underwent total arch replacement with a hand-sewn branched graft for Stanford type A acute aortic dissection 22 years ago. During follow-up, serial CT scans showed a pseudoaneurysm on the branched graft which warranted reintervention. Surgical repair involved direct suture of multiple bleeding points which were found at the sites of the hand-sewn branches anastomosis. The postoperative course was uneventful, and no signs of bleeding were observed by CT after the reoperation. Long-term follow-up is essential to detect late complications at the site of hand-sewn anastomosis.


  • Open Access

    Patch detachment after mitral valve repair with posterior leaflet augmentation: a case report

    by Toshihito Gomibuchi, Tamaki Takano, Yuko Wada, Takamitsu Terasaki, Tatsuichiro Seto, Daisuke Fukui

    Mitral valve (MV) repair is indicated for patients with severe MR. We report a case of acute MR caused by patch detachment after posterior leaflet augmentation in MV repair. A 65-year-old male underwent MV repair with posterior leaflet augmentation and coronary artery bypass graft 1 month prior to this study. An inverted T-shaped incision was made on the posterior mitral leaflet (PML), and a piece of autologous fresh pericardium was sewn in the PML defect. Seven days after hospital discharge, he started feeling chest pain and presented with pulseless electrical activity. Ultrasonic cardiography showed severe mitral regurgitation (MR), which was suggestive of acute MR. We performed emergency reoperation. The edge of the autologous pericardial patch was detached from the anterior papillary muscle, and MV replacement was performed. He was discharged from the hospital 55 days after the reoperation and returned to his normal daily life. We conclude that avoidance of tension focalization during MV repair may be important.


  • Open Access

    Early and midterm results of transapical and right axillary artery cannulation for acute aortic dissection

    by Takamitsu Terasaki, Tamaki Takano, Taishi Fujii, Tatsuichiro Seto, Yuko Wada, Yoshinori Ohtsu, Kazunori Komatsu

    We combined transapical cannulation and right axillary artery cannulation in the repair of acute type A aortic dissection in order to reduce mortality and morbidity in the presence of risk of malperfusion. Early and midterm outcomes were evaluated. Between October 2009 and March 2012, 23 aortic dissection patients (age, 54.3 ± 13.5 years) received graft replacement using a combination of transapical and right axillary artery cannulation. Preoperative malperfusion was present in 16 patients (69.6%). Cardiopulmonary bypass was initiated with axillary artery cannulation applied via the right axilla and right atrial drainage, then aotric cannulation applied via the left ventricular apex. We retrospectively investigated mortality and morbidity as well as cardiac function, which were evaluated echocardiographically during hospitalization and once a year postoperatively. All patients received total arch replacement. In-hospital mortality was 4.3%, and no patient developed intraoperative malperfusion. Intraoperative stroke occurred in one patient (4.3%), and three patients (13.0%) suffered from delayed stroke (10–24 days). These delayed strokes might have resulted from cardiogenic thrombus, although no intracardiac thrombus was found. Mean ejection fraction was 66.1 ± 10.9% in the early postoperative period and 73.1 ± 8.7% midterm. There was no left ventricular asynergy or intracardiac thrombus seen on either early or midterm echocardiography. Transapical cannulation with right axillary artery cannulation is a safe and effective procedure that can reduce operative risk associated with aortic dissection. Although transapical cannulation does not appear to impair cardiac function, it may confer a risk of delayed stroke.


  • Open Access

    Early bioprosthetic valve calcification with alfacalcidol supplementation

    by Tamaki Takano, Takamitsu Terasaki, Yuko Wada, Noburou Ohashi, Kazunori Komatsu, Daisuke Fukui, Jun Amano

    We report a case of early bioprosthetic valve calcification in a 76 year-old woman who had received supplementation with alfacalcidol, an analogue of vitamin D, for 3 years after her initial valve replacement. She underwent aortic valve replacement at the age of 71 and subsequently complained of shortness of breath. Ultrasonic cardiography revealed severe aortic stenosis and we performed a second aortic valve replacement with a bioprosthesis. Histopathologic and x-ray examination showed calcification on the explanted valve. She had not presented with any known risk for early bioprosthetic calcification, suggesting that vitamin D supplementation may accelerate calcification of bioprosthetic valves.


  • Open Access

    Prosthetic valve endocarditis caused by Staphylococcus capitis: report of 4 cases

    by Tamaki Takano, Yoshinori Ohtsu, Takamitsu Terasaki, Yuko Wada, Jun Amano

    Although Staphylococcus capitis is considered to be a rare causative organism for prosthetic valve endocarditis, we report 4 such cases that were encountered at our hospital over the past 2 years. Case 1 was a 79-year-old woman who underwent aortic valve replacement with a bioprosthetic valve and presented with fever 24 days later. Transesophageal echocardiography revealed an annular abscess in the aorto-mitral continuity and mild perivalvular regurgitation. We performed emergency surgery 5 days after the diagnosis of prosthetic valve endocarditis was made. Case 2 was a 79-year-old woman presenting with fever 40 days after aortic valve replacement with a bioprosthesis. Transesophageal echocardiography showed vegetation on the valve, and she underwent urgent surgery 2 days after prosthetic valve endocarditis was diagnosed. In case 3, a 76-year-old man presented with fever 53 days after aortic valve replacement with a bioprosthesis. Vegetation on the prosthetic leaflet could be seen by transesophageal echocardiography. He underwent emergency surgery 2 days after the diagnosis of prosthetic valve endocarditis was made. Case 4 was a 68-year-old woman who collapsed at her home 106 days after aortic and mitral valve replacement with bioprosthetic valves. Percutaneous cardiopulmonary support was started immediately after massive mitral regurgitation due to prosthetic valve detachment was revealed by transesophageal echocardiography. She was transferred to our hospital by helicopter and received surgery immediately on arrival. In all cases, we re-implanted another bioprosthesis after removal of the infected valve and annular debridement. All patients recovered without severe complications after 2 months of antibiotic treatment, and none experienced re-infection during 163 to 630 days of observation. Since the time interval between diagnosis of prosthetic valve endocarditis and valve re-replacement ranged from 0 to 5 days, early surgical removal of the infected prosthesis and an appropriate course of antibiotics were attributed to good clinical outcomes in our cases.