Takamitsu Terasaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takamitsu Terasaki has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Tamaki Takano
Department of Cardiovascular Surgery, Shinshu University School of Medicine, Matsumoto, Nagano, Japan
4 shared publications - Yuko Wada
Division of Cardiovascular Surgery, Department of Surgery, Shinshu University School of Medicine, Matsumoto, Japan
4 shared publications - Daisuke Fukui
Department of Cardiovascular Surgery, Shinshu University, Matsumoto, Japan
3 shared publications - Jun Amano
Department of Cardiovascular Surgery, Shinshu University School of Medicine, Matsumoto, Nagano, Japan
2 shared publications - Tatsuichiro Seto
Department of Surgery, Shinshu University School of Medicine, Matsumoto, Nagano, Japan
2 shared publications - Toshihito Gomibuchi
Department of Cardiovascular Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto Nagano, 390-8621, Japan
2 shared publications
Latest Publications
- Open Access
- 5 November 2015
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 10 (1) , 152
Pseudoaneurysm of graft–graft anastomosis of a hand-sewn branched graft: a case report
Pseudoaneurysm of graft–graft anastomosis is an extremely rare but potentially fatal complication after thoracic aorta replacement with a prosthetic graft. We report a case of pseudoaneurysm at the graft–graft anastomosis of a hand-sewn branched graft. A 65-year-old man underwent total arch replacement with a hand-sewn branched graft for Stanford type A acute aortic dissection 22 years ago. During follow-up, serial CT scans showed a pseudoaneurysm on the branched graft which warranted reintervention. Surgical repair involved direct suture of multiple bleeding points which were found at the sites of the hand-sewn branches anastomosis. The postoperative course was uneventful, and no signs of bleeding were observed by CT after the reoperation. Long-term follow-up is essential to detect late complications at the site of hand-sewn anastomosis.
- 5 November 2015
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 10 (1) , 152
Open AccessPseudoaneurysm of graft–graft anastomosis of a hand-sewn branched graft: a case report
Pseudoaneurysm of graft–graft anastomosis is an extremely rare but potentially fatal complication after thoracic aorta replacement with a prosthetic graft. We report a case of pseudoaneurysm at the graft–graft anastomosis of a hand-sewn branched graft. A 65-year-old man underwent total arch replacement with a hand-sewn branched graft for Stanford type A acute aortic dissection 22 years ago. During follow-up, serial CT scans showed a pseudoaneurysm on the branched graft which warranted reintervention. Surgical repair involved direct suture of multiple bleeding points which were found at the sites of the hand-sewn branches anastomosis. The postoperative course was uneventful, and no signs of bleeding were observed by CT after the reoperation. Long-term follow-up is essential to detect late complications at the site of hand-sewn anastomosis.
- Open Access
- 12 September 2015
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 10 (1) , 1-3
Patch detachment after mitral valve repair with posterior leaflet augmentation: a case report
Mitral valve (MV) repair is indicated for patients with severe MR. We report a case of acute MR caused by patch detachment after posterior leaflet augmentation in MV repair. A 65-year-old male underwent MV repair with posterior leaflet augmentation and coronary artery bypass graft 1 month prior to this study. An inverted T-shaped incision was made on the posterior mitral leaflet (PML), and a piece of autologous fresh pericardium was sewn in the PML defect. Seven days after hospital discharge, he started feeling chest pain and presented with pulseless electrical activity. Ultrasonic cardiography showed severe mitral regurgitation (MR), which was suggestive of acute MR. We performed emergency reoperation. The edge of the autologous pericardial patch was detached from the anterior papillary muscle, and MV replacement was performed. He was discharged from the hospital 55 days after the reoperation and returned to his normal daily life. We conclude that avoidance of tension focalization during MV repair may be important.
- 12 September 2015
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 10 (1) , 1-3
Open AccessPatch detachment after mitral valve repair with posterior leaflet augmentation: a case report
Mitral valve (MV) repair is indicated for patients with severe MR. We report a case of acute MR caused by patch detachment after posterior leaflet augmentation in MV repair. A 65-year-old male underwent MV repair with posterior leaflet augmentation and coronary artery bypass graft 1 month prior to this study. An inverted T-shaped incision was made on the posterior mitral leaflet (PML), and a piece of autologous fresh pericardium was sewn in the PML defect. Seven days after hospital discharge, he started feeling chest pain and presented with pulseless electrical activity. Ultrasonic cardiography showed severe mitral regurgitation (MR), which was suggestive of acute MR. We performed emergency reoperation. The edge of the autologous pericardial patch was detached from the anterior papillary muscle, and MV replacement was performed. He was discharged from the hospital 55 days after the reoperation and returned to his normal daily life. We conclude that avoidance of tension focalization during MV repair may be important.
- Open Access
- 11 September 2013
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 8 (1) , O42
Early and mid-term results of transapical and right axillary artery cannulation for acute aortic dissection
- 11 September 2013
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 8 (1) , O42
Open AccessEarly and mid-term results of transapical and right axillary artery cannulation for acute aortic dissection
- Open Access
- 16 January 2013
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 8 (1) , 11
Early bioprosthetic valve calcification with alfacalcidol supplementation
We report a case of early bioprosthetic valve calcification in a 76 year-old woman who had received supplementation with alfacalcidol, an analogue of vitamin D, for 3 years after her initial valve replacement. She underwent aortic valve replacement at the age of 71 and subsequently complained of shortness of breath. Ultrasonic cardiography revealed severe aortic stenosis and we performed a second aortic valve replacement with a bioprosthesis. Histopathologic and x-ray examination showed calcification on the explanted valve. She had not presented with any known risk for early bioprosthetic calcification, suggesting that vitamin D supplementation may accelerate calcification of bioprosthetic valves.
- 16 January 2013
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 8 (1) , 11
Open AccessEarly bioprosthetic valve calcification with alfacalcidol supplementation
We report a case of early bioprosthetic valve calcification in a 76 year-old woman who had received supplementation with alfacalcidol, an analogue of vitamin D, for 3 years after her initial valve replacement. She underwent aortic valve replacement at the age of 71 and subsequently complained of shortness of breath. Ultrasonic cardiography revealed severe aortic stenosis and we performed a second aortic valve replacement with a bioprosthesis. Histopathologic and x-ray examination showed calcification on the explanted valve. She had not presented with any known risk for early bioprosthetic calcification, suggesting that vitamin D supplementation may accelerate calcification of bioprosthetic valves.
- Open Access
- 7 October 2011
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 6 (1) , 131
Prosthetic valve endocarditis caused by Staphylococcus capitis: report of 4 cases
Although Staphylococcus capitis is considered to be a rare causative organism for prosthetic valve endocarditis, we report 4 such cases that were encountered at our hospital over the past 2 years. Case 1 was a 79-year-old woman who underwent aortic valve replacement with a bioprosthetic valve and presented with fever 24 days later. Transesophageal echocardiography revealed an annular abscess in the aorto-mitral continuity and mild perivalvular regurgitation. We performed emergency surgery 5 days after the diagnosis of prosthetic valve endocarditis was made. Case 2 was a 79-year-old woman presenting with fever 40 days after aortic valve replacement with a bioprosthesis. Transesophageal echocardiography showed vegetation on the valve, and she underwent urgent surgery 2 days after prosthetic valve endocarditis was diagnosed. In case 3, a 76-year-old man presented with fever 53 days after aortic valve replacement with a bioprosthesis. Vegetation on the prosthetic leaflet could be seen by transesophageal echocardiography. He underwent emergency surgery 2 days after the diagnosis of prosthetic valve endocarditis was made. Case 4 was a 68-year-old woman who collapsed at her home 106 days after aortic and mitral valve replacement with bioprosthetic valves. Percutaneous cardiopulmonary support was started immediately after massive mitral regurgitation due to prosthetic valve detachment was revealed by transesophageal echocardiography. She was transferred to our hospital by helicopter and received surgery immediately on arrival. In all cases, we re-implanted another bioprosthesis after removal of the infected valve and annular debridement. All patients recovered without severe complications after 2 months of antibiotic treatment, and none experienced re-infection during 163 to 630 days of observation. Since the time interval between diagnosis of prosthetic valve endocarditis and valve re-replacement ranged from 0 to 5 days, early surgical removal of the infected prosthesis and an appropriate course of antibiotics were attributed to good clinical outcomes in our cases.
- 7 October 2011
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 6 (1) , 131
Open AccessProsthetic valve endocarditis caused by Staphylococcus capitis: report of 4 cases
Although Staphylococcus capitis is considered to be a rare causative organism for prosthetic valve endocarditis, we report 4 such cases that were encountered at our hospital over the past 2 years. Case 1 was a 79-year-old woman who underwent aortic valve replacement with a bioprosthetic valve and presented with fever 24 days later. Transesophageal echocardiography revealed an annular abscess in the aorto-mitral continuity and mild perivalvular regurgitation. We performed emergency surgery 5 days after the diagnosis of prosthetic valve endocarditis was made. Case 2 was a 79-year-old woman presenting with fever 40 days after aortic valve replacement with a bioprosthesis. Transesophageal echocardiography showed vegetation on the valve, and she underwent urgent surgery 2 days after prosthetic valve endocarditis was diagnosed. In case 3, a 76-year-old man presented with fever 53 days after aortic valve replacement with a bioprosthesis. Vegetation on the prosthetic leaflet could be seen by transesophageal echocardiography. He underwent emergency surgery 2 days after the diagnosis of prosthetic valve endocarditis was made. Case 4 was a 68-year-old woman who collapsed at her home 106 days after aortic and mitral valve replacement with bioprosthetic valves. Percutaneous cardiopulmonary support was started immediately after massive mitral regurgitation due to prosthetic valve detachment was revealed by transesophageal echocardiography. She was transferred to our hospital by helicopter and received surgery immediately on arrival. In all cases, we re-implanted another bioprosthesis after removal of the infected valve and annular debridement. All patients recovered without severe complications after 2 months of antibiotic treatment, and none experienced re-infection during 163 to 630 days of observation. Since the time interval between diagnosis of prosthetic valve endocarditis and valve re-replacement ranged from 0 to 5 days, early surgical removal of the infected prosthesis and an appropriate course of antibiotics were attributed to good clinical outcomes in our cases.