JMJason Mitchell

Jason Mitchell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jason Mitchell has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Clinical Validation Study of Percutaneous Cochlear Access Using Patient-Customized Microstereotactic Frames

    by Robert F. Labadie, Ramya Balachandran, Jason E. Mitchell, Jack H. Noble, Omid Majdani, David S. Haynes, Marc L. Bennett, Benoit M. Dawant, J. Michael Fitzpatrick

    Objective: Percutaneous cochlear implant (PCI) surgery consists of drilling a single trough from the lateral cranium to the cochlea avoiding vital anatomy. To accomplish PCI, we use a patient-customized microstereotactic frame, which we call a "microtable" because it consists of a small tabletop sitting on legs. The orientation of the legs controls the alignment of the tabletop such that it is perpendicular to a specified trajectory. Study Design: Prospective. Setting: Tertiary referral center. Patients: Thirteen patients (18 ears) undergoing traditional cochlear implant surgery. Interventions: With institutional review board approval, each patient had 3 fiducial markers implanted in bone surrounding the ear. Temporal bone computed tomographic scans were obtained, and the markers were localized, as was vital anatomy. A linear trajectory from the lateral cranium through the facial recess to the cochlea was planned. A microtable was fabricated to follow the specified trajectory. Main Outcome Measures: After mastoidectomy and posterior tympanotomy, accuracy of trajectories was validated by mounting the microtables on the bone-implanted markers and then passing sham drill bits across the facial recess to the cochlea. The distance from the drill to vital anatomy was measured. Results: Microtables were constructed on a computer-numeric-control milling machine in less than 5 minutes each. Successful access across the facial recess to the cochlea was achieved in all 18 cases. The mean ± SD distance was 1.20 ± 0.36 mm from midportion of the drill to the facial nerve and 1.25 ± 0.33 mm from the chorda tympani. Conclusion: These results demonstrate the feasibility of PCI access using customized microstereotactic frames.


    • 25 August 2009
      • p. 1-6

    Percutaneous access to the petrous apex in vitro using customized micro-stereotactic frames based on image-guided surgical technology.

    by George B Wanna, Ramya Balachandran, Omid Majdani, Jason Mitchell, Robert F Labadie

    Conclusion. Our study demonstrates (in cadavers) the ability to obtain a minimally invasive approach to access the petrous apex using patient-customized micro-stereotactic frames based on pre-intervention radiographic studies. Objective. To conduct in vitro studies to demonstrate the feasibility of percutaneous petrous apex access using customized, bone-mounted, micro-stereotactic frames. Methods. Cadaveric temporal bone specimens (n=10) were affixed with three bone-implanted fiducial markers. CT scans were obtained and used in planning, in reference to the fiducial markers, a straight transmastoid infralabyrinthine trajectory from the mastoid surface to the petrous apex without violating the basal turn of the cochlea or the carotid artery. A drill press was mounted on the customized frame and used to guide a 2 mm drill bit on the desired trajectory. The course of the drill bit and its relationship to surrounding vital anatomy (cochlea, carotid artery, facial nerve, and internal jugular vein) were determined by repeat CT scanning. Results. In 10 of 10 specimens, the drill bit trajectory was accurate with clearance (mean+/-standard deviation in mm) from the cochlea, facial nerve, carotid artery, and jugular vein of 3.43+/-1.57, 3.14+/-1.15, 4.57+/-1.52, and 6.05+/-2.98, respectively.


  • Customized, rapid-production microstereotactic table for surgical targeting: description of concept and in vitro validation

    by Robert F. Labadie, Jason Mitchell, Ramya Balachandran, J. Michael Fitzpatrick

    Purpose To introduce a novel microstereotactic frame, called the Microtable, consisting of a tabletop that mounts on bone-implanted spherical markers. The microtable is customized for individual patient anatomy to guide a surgical instrument to a specified target. Methods Fiducial markers are bone-implanted, and CT scanning is performed. A microtable is custom-designed for the location of the markers and the desired surgical trajectory and is constructed using a computer-numerical-control machine. Validation studies were performed on phantoms with geometry similar to that for cochlear implant surgery. Two designs were tested with two different types of fiducial markers. Results Mean targeting error of the microtables for the two designs were 0.37 ± 0.18 and 0.60 ± 0.21 mm (n = 5). Construction of each microtable required approximately 6 min. Conclusions The new frame achieves both high accuracy and rapid fabrication. We are currently using the microtable for clinical testing of the concept of percutaneous cochlear implant surgery.