XHXingli He

Xingli He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xingli He has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Spurious-Mode Suppression and Efficient Design of LiTaO3 XBAR Filters Using a FEM–COM–ABC Framework

    by Jiabao Tang, Zifan Miao, Yunjing Zhang, Xingli He

    Laterally excited bulk acoustic wave resonators (XBARs) on lithium tantalate (LiTaO3, LT) are promising for wideband radio-frequency filters, but spurious modes and costly full-wave optimization hinder development. Limited coupling-bandwidth flexibility in commercial LT cuts motivates exploring non-standard orientations. We present a numerical framework integrating the finite-element method (FEM), coupling-of-modes (COM) theory, and artificial bee colony (ABC) optimization, emphasizing non-commercial 120° YX-LT. Hierarchical FEM screens orientation and periodic-cell response and then resolves finite aperture, busbars, and membrane boundaries. Compared with rectangular boundaries, an irregular pentagonal membrane disrupts coherent edge reflections, suppressing in-band spurious glitches and slightly enhancing effective coupling. A thickness-dependent COM model calibrated across a broad SiO2 loading range reproduces FEM resonance and antiresonance frequencies within 1 MHz. The surrogate enables mixed-variable ABC optimization of finger-pair number, normalized aperture, and stage-specific wavelengths. Five-stage ladder filters are synthesized and verified by direct FEM reconstruction. Stage-dependent wavelengths improve simulated passband transmission and reduce ripple versus a common-wavelength baseline; COM–FEM stopband discrepancies indicate the need for full-wave verification. After calibration, ABC core search takes approximately 2.9 h without repeated full-wave solutions. This transferable framework provides a cost-effective pathway from full-wave physics to circuit-level filter synthesis on thin-film piezoelectric platforms.

  • Open Access

    First-Principles Calculations and PMUT Applications of Piezoelectric Thin-Film Materials

    by Chengwei Che, Shanqing Yi, Caishuo Zhang, Xinyi Zheng, Xingli He, Dacheng Xu

    High-performance piezoelectric micromachined ultrasonic transducers (PMUTs) are crucial for portable medical imaging and sensing. The efficiency of advanced PMUTs relies on high-quality piezoelectric thin films and optimized device designs. However, variability in common piezoelectric thin films like ScxAl1−xN (ScAlN) and PbZr1−xTixO3 (PZT) often leads to inaccurate material parameters—especially those derived from thick ceramics. To enhance simulation accuracy in standard designs affected by these inconsistencies, this work introduces an optimization framework combining first-principles calculations with multiphysics simulations. First, the intrinsic properties of PZT and ScAlN are analyzed through atomistic calculations, confirming that PZT, with its higher electromechanical coupling coefficient, is better suited for actuation. The parameters obtained from these calculations calibrate the finite-element model, addressing issues of missing or inaccurate data in commercial software libraries. Next, an efficient analytical acoustic-field model is developed. Compared to full-wave simulations in COMSOL, this model significantly reduces computational cost while maintaining accuracy, allowing for quicker scanning and optimization of large-array topologies. Additionally, results demonstrate that each individual hexagonal PMUT element outperforms a comparable circular element, achieving a peak SPL of 90.4 dB at 4.9 MHz versus 89.7 dB at 2.8 MHz. This higher acoustic output and operating frequency enable improved spatial resolution and sensitivity. This modeling approach, based on intrinsic material properties, provides a solid theoretical foundation for designing high-precision, low-power ultrasonic devices.


  • Ultra-high sensitive SAW pressure sensor based on anisotropic LiNbO 3 film

    by Chuan Xu, Shuyue Jin, Yunjing Zhang, Lingfeng Li, Linghui Kong, Peng Li, Dacheng Xu, Xingli He

    This study investigates resonant-type high-frequency (∼1.6 GHz) surface acoustic wave pressure sensors based on high-performance piezoelectric thin films, with a focus on optimizing the intrinsic properties of mechanical sensing elements. X-cut lithium niobate (LiNbO₃) single-crystalline thin films serve as the primary piezoelectric substrate. Through theoretical modeling and experimental validation, the mechanisms governing sensor sensitivity are elucidated, particularly concerning the placement of the interdigital transducer (IDT) and the direction of acoustic wave propagation. Devices featuring edge-positioned IDTs achieved a sensitivity of 1417.09kHz bar and a pressure coefficient of frequency ( PCF ) of 891.29 ppm bar −1 , representing a 21.8% improvement over devices with centrally positioned IDTs. At a propagation angle of θ = 70°, the PCF reached 766.10 ppm bar −1 , corresponding to a 13.8% enhancement compared to conventional designs. All fabricated devices exhibited excellent linearity and hysteresis, even without specialized optimization.

  • Multifrequency Microwave Liquid Identification Sensor Based on Interdigital Split Ring Resonators

    by Jing Lei Yong, Peng Li, Xing Li He, Mei Song Tong, Le Tian Guo, Yun Jing Zhang

    In this paper, a novel multifrequency microwave sensor comprising four interdigital split ring resonators (SRRs) coupled to a microstrip feed line is proposed for measuring types and volume fractions of liquids. The interdigital SRR is based on a traditional SRR with its split replaced by an interdigital capacitor (IDC) structure. The IDC in the SRR, serving as the sensing region, has strong electric fields, highly responsive to variations in the dielectric properties of the sample. To mitigate the influence of the sample on the microstrip feed line, a ground plane is inserted between the feed line and sensing region. Different samples exhibit distinct resonant frequencies and transmission magnitude of the sensor, which are used to invert their complex permittivity through a mathematical relationship model. Subsequently, liquid types and concentrations can be identified based on a pre-established knowledge database. Significantly, the four-resonance frequency measurement enables to determine the dielectric dispersion of the liquids over the 2–6 GHz range, enhancing identification accuracy through the nearest neighbor search principle. Experiments conducted with various liquid types and ethanol solutions of varying concentrations demonstrate the superior identification capability of the sensor. The sensor’s compact size, simple structure, and high identification accuracy highlight its potential for on-site, real-time, non-invasive detection applications.


  • Open Access

    Laterally Excited Resonators Based on Single-Crystalline LiTaO3 Thin Film for High-Frequency Applications

    by Chongrui Guan, Xingli He

    High-performance acoustic resonators based on single-crystalline piezoelectric thin films have great potential in wireless communication applications. This paper presents the modeling, fabrication, and characterization of laterally excited bulk resonators (XBARs) utilizing the suspended ultra-thin (~420 nm) LiTaO3 (LT, with 42° YX-cut) film. The finite element analysis (FEA) was performed to model the LT-based XBARs precisely and to gain further insight into the physical behaviors of the acoustic waves and the loss mechanisms. In addition, the temperature response of the devices was numerically calculated, showing relatively low temperature coefficients of frequency (TCF) of ~−38 ppm/K for the primary resonant mode. The LT-based XBARs were fabricated and characterized, which presents a multi-resonant mode over a wide frequency range (0.1~10 GHz). For the primary resonance around 4.1 GHz, the fabricated devices exhibited a high-quality factor (Bode-Q) ~ 600 and piezoelectric coupling (kt2) ~ 2.84%, while the higher-harmonic showed a greater value of kt2 ~ 3.49%. To lower the resonant frequency of the resonator, the thin SiO2 film (~20 nm) was sputtered on the suspended device, which created a frequency offset between the series and shunt resonators. Finally, a ladder-type narrow band filter employing five XBARs was developed and characterized. This work effectively demonstrates the performance and application potential of micro-acoustic resonators employing high-quality LT films.


  • Single-Crystalline LiNbO₃ Film-Based Piezoelectric Sensors for Ultra-Precision Pressure-Sensing Applications

    by Junwei Gu, Xingli He, Shuyue Jin, Yunjing Zhang, Lingfeng Li, Linghui Kong, Peng Li

    This work presents the fabrication and characterization of a sub-GHz plate-wave-based pressure sensor relying on an ultra-thin (360 nm) single-crystalline LiNbO 3 film. The proposed devices exhibit multiple resonant modes which are characterized and analyzed by a precise 3D plate wave resonator model based on finite element analysis (FEA). Generally, the main resonant modes correspond to the Shear-horizontal ( SH ) and anti-symmetric ( A ) Lamb waves. To overcome the high-temperature coefficient of LiNbO 3 thin film, a thick layer (~4 μm) of SiO 2 was used to compensate for the temperature drift of the devices; the calculated temperature coefficients of frequency ( TCFs ) for the multi-resonant modes are lower than -27 ppm/K. The frequency and return loss (S 11 ) shift of the plate wave devices, the pressure sensitivity, and the pressure coefficient of frequency ( PCF ) were experimentally evaluated and analyzed. All the resonant modes show high PCF even with relatively lower operating frequencies (< 1 GHz). Especially it has been observed that the first-order anti-symmetric (A1) Lamb wave is ultra-susceptible to pressure changes, which presented a record high value of ~600 ppm/Bar and excellent linearity over the tested 0.6 to 1.8 Bar pressure range. The results show that the developed sensor has sufficiently high sensitivity and can be used for precise absolute pressure sensing.


  • Open Access

    SH-BAW devices with abnormal mass-loading effect for chemical sensing

    by Junjie Shen, Haibo Chen, Zimeng Shi, Linghui Kong, Yunjing Zhang, Lingfeng Li, Peng Li, Xingli He

    Surface acoustic wave (SAW) devices are promising for chemical and biological sensing applications. This work studies the basic operating principles and the physical behaviors of the “Rayleigh”-SAW and the “Shear Horizontal (SH-)” bulk acoustic wave (BAW), particularly in relation to the chemisorption process. A complete 3D delay line SAW model is developed and performed by the finite element analysis, and a methodology was introduced for characterizing the transmission characteristics (S21) of these devices. Notably, our investigation unveils an intriguing phenomenon in the behavior of SH-BAW in response to loading mass. We observed an anomalous shift in the central frequency, which increases as the chemical adsorbate concentration rises. Leveraging these insights, we designed and constructed a SAW-based gas sensor, and the vinyl-terminated polydimethylsiloxane was synthesized for the detection of chloroform, a challenging pollutant to identify. Through a comparative study, we illustrate distinct responses of Rayleigh-SAW and SH-BAW devices to accumulated loading mass and gaseous contaminants. These experimental results validate and corroborate our simulations. This work demonstrates a unique mass-loading effect exhibited by SH-BAW devices, which differs from the existing theories. These findings offer the opportunity to refine and enhance models for accurately describing the functionality of delay line SAW sensors, thereby contributing to improved sensor reliability.


  • Enhanced Sensitivity of Wired and Wireless Measurement for Liquid Concentration Based on a Modified Cylindrical Cavity

    by Ying Tian, Xing Li He, Ling Feng Li, Peng Li, Yun Jing Zhang

    This paper presents a miniaturized microwave sensor based on a cylindrical cavity for detecting the concentration of water-glucose solutions. To enhance the sensitivity, the cavity is modified in which two symmetrical metal wires with respect to its center are embedded. Compared with the conventional cavity, in the wired measurement, the modified sensor has increased sensitivities by 53% and 44% in terms of shifts of reflection and transmission resonant frequencies f 11 and f 21 , which are 17.86 MHz and 14.16 MHz per 1% concentration, respectively. In addition, semi-wireless and passive full-wireless measurement methods are proposed. With a measuring distance of 30 cm, experimental results show that the sensitivities of the semi-wireless measurement are 8.82 MHz/1% and 6.11 MHz/1% for f 11 and f 21 , which are increased by 50% and 35% respectively compared with the conventional cavity. The proposed full-wireless measurement with advantages including passivity, long-distance, and low-cost has high sensitivity of 2.74 MHz/1% with the reading distance of 30 cm. Compared with other microwave glucose sensors, the proposed sensor has better performance and the wireless methods are novel, which are expected to be used in biological and chemical sensors.


  • Open Access

    Detection of Trace Explosives Using a Novel Sample Introduction and Ionization Method

    by Lingfeng Li, Tianyi Zhang, Wei Ge, Xingli He, Yunjing Zhang, Xiaozhi Wang, Peng Li

    A novel sample introduction and ionization method for trace explosives detection is proposed and investigated herein, taking into consideration real-world application requirements. A thermal desorption sampling method and dielectric barrier discharge ionization (DBDI) source, with air as the discharge gas, were developed. The counter flow method was adopted firstly into the DBDI source to remove the interference of ozone and other reactive nitrogen oxides. A separated reaction region with an ion guiding electric field was developed for ionization of the sample molecules. Coupled with a homemade miniature digital linear ion trap mass spectrometer, this compact and robust design, with further optimization, has the advantages of soft ionization, a low detection limit, is free of reagent and consumable gas, and is an easy sample introduction. A range of common nitro-based explosives including TNT, 2,4-DNT, NG, RDX, PETN, and HMX has been studied. A linear response in the range of two orders of magnitude with a limit of detection (LOD) of 0.01 ng for TNT has been demonstrated. Application to the detection of real explosives and simulated mixed samples has also been explored. The work paves the path to developing next generation mass spectrometry (MS) based explosive trace detectors (ETDs).


  • Open Access

    Ultra-Fast Polarity Switching, Non-Radioactive Drift Tube for the Miniaturization of Drift-Time Ion Mobility Spectrometer

    by Lingfeng Li, Hao Gu, Yanzhen Lv, Yunjing Zhang, Xingli He, Peng Li

    Drift-time ion mobility spectrometer (DT-IMS) is a promising technology for gas detection and analysis in the form of miniaturized instrument. Analytes may exist in the form of positively or negatively charged ions according to their chemical composition and ionization condition, and therefore require both polarity of electric field for the detection. In this work the polarity switching of a drift-time ion mobility spectrometer based on a direct current (DC) corona discharge ionization source was investigated, with novel solutions for both the control of ion shutter and the stabilization of aperture grid. The drift field is established by employing a switchable high voltage power supply and a serial of voltage regulator diode, with optocouplers to drive the ion shutter when the polarity is switched. The potential of aperture grid is stabilized during the polarity switching by the use of four diodes to avoid unnecessary charging cycle of the aperture grid capacitor. Based on the proposed techniques, the developed DT-IMS with 50 mm drift path is able to switch its polarity in 10 ms and acquire mobility spectrum after 10 ms of stabilization. Coupled with a thermal desorption sampler, limit of detection (LoD) of 0.1 ng was achieved for ketamine and TNT. Extra benefits include single calibration substance for both polarities and largely simplified pneumatic design, together with the reduction of second drift tube and its accessories. This work paved the way towards further miniaturization of DT-IMS without compromise of performance.