MFMark Foley

Mark Foley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mark Foley has a total of 75 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigation of naturally-occurring radioactive materials (NORM) in building materials in Ireland

    by R. E. Djabou, M. Dodek, C. Sainz, I. Fuente, L. L. Vintró, O. Hanley, J. Goggins, M. Foley

    Naturally-occurring radioactive materials (NORM), primarily from the decay chains of uranium (U-238) and thorium (Th-232), as well 1as potassium (K-40), are commonly found in raw materials used in the construction industry. These radionuclides contribute to indoor radiation exposure, particularly in enclosed environments. As part of the NORM-BMI project, this study evaluated the activity concentrations of Ra-226, Th-232, and K-40 in commonly used building materials in Ireland, specifically tiles, cement, and concrete. The assessment focused on calculating the Gamma Index (Iγ) to determine radiation safety, using high-resolution gamma spectrometry in three independent laboratories (University of Cantabria, University College Dublin, and the Environmental Protection Agency Laboratory). The results indicated that tile samples exhibited the highest concentrations of radionuclides, particularly Ra-226 and K-40, with Gamma Index values approaching the recommended threshold (Iγ ≈ 1). In contrast, cement and demolition concrete samples showed low activity concentrations and Gamma Index values well below 1, indicating minimal radiological risk. Comparison with European datasets confirmed the relative safety of these building materials, particularly concrete and cement. These findings support the development of national screening protocols and contribute to safer, more sustainable construction practices, while also informing EU initiatives focused on the recycling and reuse of building materials.


  • Open Access

    NORM-BMI: Investigation of naturally occurring radioactive material (NORM) in building materials in Ireland.

    by Mateusz Dodek, Rihab El Houd, Mark Foley, Jamie Goggins

    The NORM-BMI project is an Environmental Protection Agency (EPA) funded study designed to (i) investigate activity concentrations of naturally occurring radionuclides in key building-material categories used in Ireland, and (ii) develop recommendations on how Ireland should adopt the EU Basic Safety Standards (EU-BSS, 2013/59/Euratom) for building materials. A three-batch sampling strategy was adopted. Batch 1 covered common bulk materials (concrete, cement, aggregates, gypsum products, plaster and tiles) to enable comparison with recent European datasets. Batch 2 targeted aggregates, construction sands and demolition materials, extending the sample range to legacy and recycled products. Batch 3 included aggregates from different geological locations (influenced by Tellus data), industrial by-products and imported tiles. The radiological assessment is based on the activity concentration Gamma Index (Iγ) defined in the EU-BSS, a screening quantity derived solely from the activity concentrations of Ra-226, Th-232 and K-40, with Iγ = 1 corresponding to the reference level of 1 mSv·y⁻¹ for bulk building materials. Samples are measured by high-resolution HPGe gamma spectrometry in three laboratories: the EPA Laboratory (Dublin), University College Dublin (UCD) and the University of Cantabria (Spain). EPA and UCD employ closely harmonised procedures, including identical container geometries, whereas the Spanish laboratory (the only one of the three accredited for building-material measurements) uses different sealing protocols, count times and geometries, providing a realistic interlaboratory comparison under non-identical but operationally relevant conditions. Preliminary results show that all bulk construction materials investigated (concretes, cements, aggregates and sands) exhibit Iγ values below the EU-BSS screening level of 1, while some tiles yield indices slightly above 1 but within the higher limit applicable to superficial materials. Together with a review of regulatory practice in other EU Member States, these results underpin practical recommendations for how Ireland could phase in EU-BSS compliant control of NORM in construction materials and design a scalable national monitoring programme.

  • Performance Characterization of an Inorganic Scintillation Dosimeter Under 6 MV Photon Beam With Temporal Separation of Cerenkov Radiation

    by Majed Alharbi, Mina M. Habib, Faisal Alrehily, Martin Santiago, Mark Foley, Nahuel Martinez

    This study aimed to evaluate the performance of an inorganic scintillation dosimeter (ISD) based on the Gd₂O₂S:Tb scintillator, when employing the temporal filtration technique for Cerenkov radiation elimination. The investigation includes physical measurements such as repeatability of the output signal, angular dependence and percentage depth dose (PDD) profiles across varying field sizes and Monte Carlo (MC) simulation of the measured PDDs. Very good output signal stability was calculated across different radiation doses, with maximum deviations of 1.10% and 0.55% at 20 MU and 100 MU, respectively. However, the geometrical design of the dosimeter sensitive volume resulted in a pronounced angular dependence with a maximum deviation of 19% at a gantry angle of 90° in the azimuthal configuration. The results of the MC simulation show discrepancies between the measured and simulated profiles, even after accounting for Cerenkov radiation and absorbed dose energy dependence, suggesting that factors related to the intrinsic energy dependence of the Gd₂O₂S:Tb material influence the ISD’s response at depth. These findings highlight the system potential for radiotherapy applications while stressing the need for further design optimization to reduce angular dependence, and for a deeper understanding of material-specific scintillation behavior affecting dosimetric performance.

  • Open Access

    Radon mitigation by soil depressurisation case study: radon concentration and pressure field extension monitoring in a pilot house in Spain

    by Marta Fuente, Jamie Goggins, Daniel Rabago, Ismael Fuente, Carlos Sainz, Mark Foley

    A one-year monitoring study was conducted in a pilot house with high radon levels to investigate the ability and efficiency of radon mitigation by soil depressurisation (SD) both active and passive. The study included monitoring of radon concentration, pressure field extension (pfe) under the slab and some atmospheric parameters for different testing phases. Periods in which the house remained closed to foster radon accumulation were alternated with phases of active and passive soil depressurisation under different conditions. The behaviour of the radon concentration in the pilot house was analysed along with the influence of atmospheric variables, significant correlations were found for the radon concentration with atmospheric pressure, outdoor temperature and wind. From the pfe analysis it was proven that the pressure drop with distance from the suction point of the SD system is proportional to the depressurisation generated. It was found also that the permeability characterisation of the pilot house agrees with the literature about granular fill materials characterisation for radon SD systems across Europe. Radon reductions in excess of 85% were achieved for the different testing phases in all cases. Finally, from the results it was stated that a fan power of 23 W is sufficient to ensure radon reductions over 85% for dwellings with similar aggregate layer and soil permeability.

  • Open Access

    Analysis of CyberKnife intracranial treatment plans using ICRU 91 dose reporting: A retrospective study

    by Dion Conlon, James Connolly, Mohamed Galal, Ismail Ahmed, Mark Foley, Christoph Kleefeld

    ICRU 91, published in 2017, is an international standard for prescribing, recording, and reporting stereotactic treatments. Since its release, there has been limited research published on the implementation and impact of ICRU 91 on clinical practice. This work provides an assessment of the recommended ICRU 91 dose reporting metrics for their use in clinical treatment planning. A set of 180 intracranial stereotactic treatment plans for patients treated by the CyberKnife (CK) system were analyzed retrospectively using the ICRU 91 reporting metrics. The 180 plans comprised 60 trigeminal neuralgia (TGN), 60 meningioma (MEN), and 60 acoustic neuroma (AN) cases. The reporting metrics included the planning target volume (PTV) near‐minimum dose (), near‐maximum dose (), and median dose (), as well as the gradient index (GI) and conformity index (CI). The metrics were assessed for statistical correlation with several treatment plan parameters. In the TGN plan group, owing to the small targets, was greater than in 42 plans, whereas both metrics were not applicable in 17 plans. The metric was predominantly influenced by the prescription isodose line (PIDL). The GI was significantly dependent on target volume in all analyses performed, where the variables were inversely related. The CI was only dependent on target volume in treatment plans for small targets. The ICRU 91 and metrics breakdown in plans for small target volumes below 1 cm3; the Min and Max pixel should be reported in such cases. The metric is of limited use for treatment planning. Given their volume dependence, the GI and CI metrics could potentially serve as plan evaluation tools in the planning of the sites analyzed in this study, which would ultimately improve treatment plan quality.


  • Evaluating the temperature dependence of an inorganic scintillator detector using the HYPERSCINT research platform

    by Owen Mc Laughlin, Michael Martyn, Christoph Kleefeld, Mark J. Foley

    Optical fibre scintillation detectors have proven to be a viable alternative in clinical radiation dosimetry. By obtaining active readouts, scintillators can be used to give real time measurements for various clinical and pre-clinical applications from radiology to radiation therapy. Gd2O2S:Pr is of interest as a scintillator due to it offering a much higher light output than other scintillators, organic scintillators in particular. Temperature dependence is exhibited by a number of organic scintillators, such as BCF-60; this however needs to be established for the inorganic scintillator Gd2O2S:Pr. This study therefore aims to characterize the temperature dependence of Gd2O2S:Pr, using the HYPERSCINT Research Platform 200. The detector was immersed in water and the temperature varied from 22.7°C to 49.0°C using a hotplate and temperature controller. Five spectra were recorded and averaged at each of the seven temperatures, in approximately 5°C increments. A decrease in total photon count with temperature was observed of 0.22%/°C between 346 and 631 nm with a decrease of 0.38 in the full width at half maximum at the photopeak of 513 nm. A method of correcting for temperature is necessary in the use of Gd2O2S:Pr as a detection material in environments where the temperature differs significantly from the calibration temperature.

  • Open Access

    Review of recent radon research in Ireland, OPTI-SDS project and its impact on the National Radon Control Strategy

    by Marta Fuente, Stephanie Long, David Fenton, Le Chi Hung, Jamie Goggins, Mark Foley


  • Initial Evaluation of the Performance of Novel Inorganic Scintillating Detectors for Small Animal Irradiation Dosimetry

    by Kevin Byrne, Majed Alharbi, Nolan Esplen, Peter Woulfe, Sinead O'KEeffe, Magdalena Bazalova-Carter, Mark Foley

    The purpose of this study was to design and evaluate the performance of four novel inorganic scintillating detectors (ISDs) on the Small Animal Radiation Research Platform (SARRP). Relative scintillator output, measurement repeatability, setup uncertainty, linearity with dose rate, and signal reproducibility over time were investigated. The Gd 2 O 2 S:Tb detector had the highest relative signal output, generating up to 219 times more charge than a previously characterized BCF-60-based plastic scintillating detector (PSD). The Gd 2 O 2 S:Tb detector was then used to measure 220 kVp therapy beam profiles of 10 x 10 and 5 x 5 mm 2 fields. Beam profiles using the ZnS-based phosphor were also obtained and compared to investigate the performance of a lower density inorganic scintillator. 10 x 10 and 5 x 5 mm 2 therapy beam profile measurements made with the Gd 2 O 2 S:Tb and BCF-60 detectors differed, on average, by 1.1% and 1.9%, respectively. The ZnS:Ag measurements differed, on average, by 2.5% and 6% relative to BCF-60 measurements of the 10 x 10 and 5 x 5 mm 2 beam profiles, respectively. MicroCT imaging of the detector volumes was also performed, revealing poor packing of the ZnS:Ag crystalline phosphor in the deepest region of the cylindrical cavity. The Gd 2 O 2 S:Tb detector, in particular, has proven to be a promising candidate for real-time dosimetry of small fields in small animal irradiators, primarily because of the very large signal intensities observed, along with good repeatability, dose rate linearity, reproducibility and agreement with beam profile measurements made with a previously validated detector.


  • Benchmarking a novel inorganic scintillation detector for applications in radiation therapy

    by Majed Alharbi, Michael Martyn, Sinead O'KEeffe, François Therriault-Proulx, Luc Beaulieu, Mark Foley