    Dosimetric investigation of small fields in radiotherapy measurements using Monte Carlo simulations, CC04 ionization chamber, and razor diode

    by Mina M. Habib, Mahmoud H. Abdelgawad, Albert Guirguis, Majed Alharbi, Kareem El-Maraghy, Abdelsattar M. Sallam

    The motivation of this study is to check the dosimetry of small field sizes used in various treatment techniques using different methods (Monte Carlo simulations and detectors). We created two Monte Carlo models for Elekta Versa HD linear accelerators using EGSnrc (BEAMnrc-DOSXYZnrc) codes. Previous studies led us to define one model with an ideal symmetry full‐width‐half‐maximum (FWHM) of 0.15 cm in the x and y directions for the Gaussian distribution of the primary electron source and redefine the other with a larger asymmetry FWHM of 0.35 cm in the X and 0.6 cm in the Y directions. We calculated the penumbra width using both models. We measured output factors using two different detectors including Razor Diode which is designed especially for small field size measurements and compared them with both models. Using these detectors aims to investigate different detector sensitivities for dose measurements. In addition, patient-specific planning quality assurance (PSQA) for four fictional cases using Elekta Versa HD with Nasopharyngeal, Astrocytoma, right cerebellum, and right breast cancers were done using an IBA—2D array and compared to the minimum segment width parameter in Monaco Treatment planning system (TPS) for (0.5 and 1) cm segment width. The results indicated that Monte Carlo simulation shows increasing in the values of penumbra width with increasing the size of FWHM for field size range 0.5 × 0.5 to 3 × 3 (in-plane: 0.33 to 0.45 for model 1 and 0.46 to 0.65 for model 2, cross-plane: 0.29 to 0.38 for model 1 and 0.44 to 0.62 for model 2). The results indicate that output factors decrease as FWHM increases. The Razor Diode and CC04 detectors show consistent results up until a field size of 1 × 1 cm2. Additionally, plans with a minimum segment width of 0.5 cm demonstrate a lower gamma passing rate (GPR) compared to those with a 1 cm segment width. In conclusion, Inaccurate modeling of the FWHM of the primary source can lead to a significant error in the calculation when using a Monte Carlo model of the beam; Accordingly, this may lead to inaccurate delivery of treatment dose for cancer patients, in addition, this error increases as we go down field size 1 × 1 cm2 to reach an unacceptable level in field size 0.5 × 0.5 cm2. Thus, and as found, we can conclude that: to produce a more accurate radiotherapy treatment plan which in turn will lead to high-quality treatment for cancer patients, It is recommended that, during the beam-shaping process in IMRT or VMAT optimization, the minimum dimensions of any individual beamlet or segment within the treatment field should not be smaller than 1 × 1 cm2.


  • Performance Characterization of an Inorganic Scintillation Dosimeter Under 6 MV Photon Beam With Temporal Separation of Cerenkov Radiation

    by Majed Alharbi, Mina M. Habib, Faisal Alrehily, Martin Santiago, Mark Foley, Nahuel Martinez

    This study aimed to evaluate the performance of an inorganic scintillation dosimeter (ISD) based on the Gd₂O₂S:Tb scintillator, when employing the temporal filtration technique for Cerenkov radiation elimination. The investigation includes physical measurements such as repeatability of the output signal, angular dependence and percentage depth dose (PDD) profiles across varying field sizes and Monte Carlo (MC) simulation of the measured PDDs. Very good output signal stability was calculated across different radiation doses, with maximum deviations of 1.10% and 0.55% at 20 MU and 100 MU, respectively. However, the geometrical design of the dosimeter sensitive volume resulted in a pronounced angular dependence with a maximum deviation of 19% at a gantry angle of 90° in the azimuthal configuration. The results of the MC simulation show discrepancies between the measured and simulated profiles, even after accounting for Cerenkov radiation and absorbed dose energy dependence, suggesting that factors related to the intrinsic energy dependence of the Gd₂O₂S:Tb material influence the ISD’s response at depth. These findings highlight the system potential for radiotherapy applications while stressing the need for further design optimization to reduce angular dependence, and for a deeper understanding of material-specific scintillation behavior affecting dosimetric performance.

  • Initial Evaluation of the Performance of Novel Inorganic Scintillating Detectors for Small Animal Irradiation Dosimetry

    by Kevin Byrne, Majed Alharbi, Nolan Esplen, Peter Woulfe, Sinead O'KEeffe, Magdalena Bazalova-Carter, Mark Foley

    The purpose of this study was to design and evaluate the performance of four novel inorganic scintillating detectors (ISDs) on the Small Animal Radiation Research Platform (SARRP). Relative scintillator output, measurement repeatability, setup uncertainty, linearity with dose rate, and signal reproducibility over time were investigated. The Gd 2 O 2 S:Tb detector had the highest relative signal output, generating up to 219 times more charge than a previously characterized BCF-60-based plastic scintillating detector (PSD). The Gd 2 O 2 S:Tb detector was then used to measure 220 kVp therapy beam profiles of 10 x 10 and 5 x 5 mm 2 fields. Beam profiles using the ZnS-based phosphor were also obtained and compared to investigate the performance of a lower density inorganic scintillator. 10 x 10 and 5 x 5 mm 2 therapy beam profile measurements made with the Gd 2 O 2 S:Tb and BCF-60 detectors differed, on average, by 1.1% and 1.9%, respectively. The ZnS:Ag measurements differed, on average, by 2.5% and 6% relative to BCF-60 measurements of the 10 x 10 and 5 x 5 mm 2 beam profiles, respectively. MicroCT imaging of the detector volumes was also performed, revealing poor packing of the ZnS:Ag crystalline phosphor in the deepest region of the cylindrical cavity. The Gd 2 O 2 S:Tb detector, in particular, has proven to be a promising candidate for real-time dosimetry of small fields in small animal irradiators, primarily because of the very large signal intensities observed, along with good repeatability, dose rate linearity, reproducibility and agreement with beam profile measurements made with a previously validated detector.


  • Benchmarking a novel inorganic scintillation detector for applications in radiation therapy

    by Majed Alharbi, Michael Martyn, Sinead O'KEeffe, François Therriault-Proulx, Luc Beaulieu, Mark Foley


  • Dosimetric Characterization of an Inorganic Optical Fiber Sensor for External Beam Radiation Therapy

    by Majed Alharbi, Sean Gillespie, Peter Woulfe, Pat Mccavana, Sinead O'KEeffe, Mark Foley

    The aim of this study was to investigate the dosimetric performance of a novel optical fiber sensor for use in external beam radiation therapy. Repeatability and reproducibility of the output signal, linearity, dose rate and dose per pulse dependence were evaluated. Angular dependence was investigated in the axial and azimuthal planes. The percentage depth dose and lateral dose profiles were measured using the optical fiber sensor system and compared to commercially available detectors such as Exradin W1 plastic scintillator and a PTW-microdiamond detector. The result of this study show that the optical fiber sensor system has good repeatability and reproducibility of the output signal with a maximum deviation of 0.17% and 1.00%, respectively. The system also showed an excellent linearity with dose, and its signal was independent of dose rate. However, the system showed a strong dependence on dose per pulse with 27% deviation from the W1 result at the highest dose per pulse value that was achieved at 75 cm source to surface distance. The system also showed an angular dependence when the incident beam was in the azimuthal plane due to the geometry of the scintillator at the tip of the fiber. The optical fiber sensor over-responded when measuring percentage depth dose curves and lateral dose profiles due in part to the sensitivity of the scintillating material (Gd2O2S:Tb) to low energy scattered radiation. However, further investigation is needed to quantify the overall contribution of Cerenkov radiation to the over-response of the optical fiber sensor.


  • Performance of an inorganic optical fiber dosimeter for external beam radiation therapy

    by Majed Alharbi, Michael Martyn, Lingxia Chen, Sean Gillespie, Peter Woulfe, Sinead O’keeffe, Mark Foley


  • Novel optical fiber sensors and their applications in radiotherapy

    by Majed Alharbi, Michael Martyn, Lingxia Chen, Sean Gillespie, Peter Woulfe, Sinead O’Keeffe, Mark Foley

    The aim of this study was to investigate the over-response of an inorganic optical fibre sensor (OFS) when measuring percentage depth dose curves (PDDs) with respect to an ion chamber by means of physical measurements and Monte Carlo (MC) simulations. The sensor was constructed by filling a cavity (700 μm diameter and 7 mm deep), which was made in a PMMA (polymethyl methacrylate) plastic optical fibre, with an inorganic scintillating material: terbium doped gadolinium oxysulphide (Gd2O2S:Tb). The MC software packages BEAMnrc and DOSXYZnrc were used to develop a MC model of an Elekta Versa HD linear accelerator (linac), which was then used to simulate the Gd2O2S:Tb scintillator. The results of the PDD measurements showed a depth dependence of the OFS, however the percentage differences between the ion chamber and the OFS measurements showed that as the radiation field size decreases, the difference between the two measurements decreases from 16.5% to 5.1% for 10x10 cm2 and 2x2 cm2, respectively. The MC simulation of the sensor showed a good agreement compared to physical measurements at shallow depth in the phantom; however, discrepancies were observed at depth, which was less pronounced for 4x4 cm2 than for 10x10 cm2. The results of this study indicate that including Cerenkov radiation measurements is essential to accurately quantify the overresponse and the higher discrepancy between the measured and simulated PDD profiles of the OFS.


  • Novel optical fibre dosimeters and their applications in radiotherapy: A Monte Carlo study

    by Majed Alharbi, Michael Martyn, Peter Woulfe, Lingxia Chen, Sinead O’keeffe, Mark Foley