Atul Srivastava
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Atul Srivastava has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Mohd Moiz
Department of Mechanical Engineering, Indian Institute of Technology 2 , Bombay, India
11 shared publications - Suneet Singh
Department of Energy Science and Engineering, Indian Institute of Technology Bombay, Mumbai, India
7 shared publications - Alok Kumar
Department of Mechanical Engineering, Indian Institute of Technology Bombay , Powai, Mumbai 400076, India
6 shared publications - Manish Kumar5 shared publications
- Mohammad Autif Shahdhaar
Center for Research in Nano Technology and Science, Indian Institute of Technology Bombay 1 , Mumbai 400076, India
5 shared publications - Sai Raja Gopal Vadlamudi
Helmholtz‐Zentrum Dresden‐Rossendorf (HZDR) Institute of Fluid Dynamics Dresden Germany
5 shared publications
Latest Publications
- Open Access
- 11 July 2026
- Published by Elsevier in SSRN Electronic Journal
Numerical investigation of interfacial thermal gradients during direct contact condensation of steam in subcooled water pool
Direct contact condensation (DCC) of steam bubble in subcooled water pool is numerically investigated to quantify the effects of key operating parameters-liquid subcooling, tank pressure, and vapor mass flux on interfacial temperature gradients, mass transfer rate, heat-transfer coefficient, and bubble volume. To the authors’ knowledge, this work presents the first CFD study of spatio-temporal evolution of interfacial temperature gradients and heat transfer coefficients during DCC, and determines the effect of operating pressure on interfacial heat transfer rates during DCC of vapor at subsonic conditions. The vapor–liquid interface is captured using Volume-of-Fluid framework, and phase change is modelled via the Hertz–Knudsen relation. The simulations show a periodic sequence of bubble growth, necking, detachment and collapse, accompanied by a thin interfacial layer across which large temperature gradients are localized. These gradients are non-uniformly distributed over the bubble surface, with elevated values at the leading front during bubble growth and reaching maximum near the constricted neck region prior to detachment. Increasing tank pressure or decreasing vapor mass flux suppresses the frequency of periodic evolution of bubble and leads to more spatially and temporally uniform temperature gradients, whereas increasing liquid subcooling enhances both interfacial gradients and condensation rate. The interfacial temperature gradients predicted by simulations show strong agreement with experimental visualizations reported in literature, confirming that the dominant condensation structures are accurately captured. The results provide mechanistic insight into how operating conditions control interfacial transport during DCC and offer physics-based trends for validating and improving predictive models used in the design of thermal–hydraulic systems.
- 11 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNumerical investigation of interfacial thermal gradients during direct contact condensation of steam in subcooled water pool
Direct contact condensation (DCC) of steam bubble in subcooled water pool is numerically investigated to quantify the effects of key operating parameters-liquid subcooling, tank pressure, and vapor mass flux on interfacial temperature gradients, mass transfer rate, heat-transfer coefficient, and bubble volume. To the authors’ knowledge, this work presents the first CFD study of spatio-temporal evolution of interfacial temperature gradients and heat transfer coefficients during DCC, and determines the effect of operating pressure on interfacial heat transfer rates during DCC of vapor at subsonic conditions. The vapor–liquid interface is captured using Volume-of-Fluid framework, and phase change is modelled via the Hertz–Knudsen relation. The simulations show a periodic sequence of bubble growth, necking, detachment and collapse, accompanied by a thin interfacial layer across which large temperature gradients are localized. These gradients are non-uniformly distributed over the bubble surface, with elevated values at the leading front during bubble growth and reaching maximum near the constricted neck region prior to detachment. Increasing tank pressure or decreasing vapor mass flux suppresses the frequency of periodic evolution of bubble and leads to more spatially and temporally uniform temperature gradients, whereas increasing liquid subcooling enhances both interfacial gradients and condensation rate. The interfacial temperature gradients predicted by simulations show strong agreement with experimental visualizations reported in literature, confirming that the dominant condensation structures are accurately captured. The results provide mechanistic insight into how operating conditions control interfacial transport during DCC and offer physics-based trends for validating and improving predictive models used in the design of thermal–hydraulic systems.
- Open Access
- 1 June 2026
- Published by Elsevier in SSRN Electronic Journal
Vapor evolution and condensation dynamics in a differentially-heated immiscible DCM-Water layer system: High speed videography and IR measurements
The present study is concerned with the experimental investigation of boiling and condensation characteristics of one of the high volatile fluids as it undergoes phase change in a differentially-heated two-fluids system. The vertically stratified immiscible-fluids system is realized with dichloromethane (DCM), the more volatile component, as the (heavier) bottom fluid and water as the top fluid layer. Phase change in the bottom DCM layer is affected through localized heating using a transparent ITO-coated borofloat glass substrate, triggering nucleate boiling. The resulting vapor bubbles rise through the overlying water layer and condense on a horizontally placed top plate. Synchronized high-speed videography and infrared thermography are employed to resolve key interfacial processes including nucleation, interface deformation, neck formation, pinch-off of entrapped vapor volume, and its condensation at the top plate. An energy balance framework is developed to quantify local heat storage, lateral conduction, natural convection, radiation at the top plate. The analysis shows that lateral conduction within the copper plate constitutes the dominant heat dissipation pathway during condensation. Spatio-temporal variations in surface heat flux around the impact region highlight the influence of localized phase-change events on transient thermal transport. Comparison of the total estimated dissipated energy with the theoretical latent energy corresponding to a pure vapor bubble reveals that the entrapped volume carries a lower effective vapor content. It is thus inferred that the entrapped vapor bubble therefore consists of a composite liquid–vapor mixture, with the liquid fraction estimated to be approximately 45–58% across the tested heat flux range. The presence of this encapsulated liquid layer explains the stability of the rising entrapped volume, which undergoes almost negligible condensation while traversing through the water layer. The insights obtained enhance the understanding of vapor transport and condensation mechanisms in immiscible fluid systems and offer guidance for the development of passive, high-performance thermal management schemes.
- 1 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessVapor evolution and condensation dynamics in a differentially-heated immiscible DCM-Water layer system: High speed videography and IR measurements
The present study is concerned with the experimental investigation of boiling and condensation characteristics of one of the high volatile fluids as it undergoes phase change in a differentially-heated two-fluids system. The vertically stratified immiscible-fluids system is realized with dichloromethane (DCM), the more volatile component, as the (heavier) bottom fluid and water as the top fluid layer. Phase change in the bottom DCM layer is affected through localized heating using a transparent ITO-coated borofloat glass substrate, triggering nucleate boiling. The resulting vapor bubbles rise through the overlying water layer and condense on a horizontally placed top plate. Synchronized high-speed videography and infrared thermography are employed to resolve key interfacial processes including nucleation, interface deformation, neck formation, pinch-off of entrapped vapor volume, and its condensation at the top plate. An energy balance framework is developed to quantify local heat storage, lateral conduction, natural convection, radiation at the top plate. The analysis shows that lateral conduction within the copper plate constitutes the dominant heat dissipation pathway during condensation. Spatio-temporal variations in surface heat flux around the impact region highlight the influence of localized phase-change events on transient thermal transport. Comparison of the total estimated dissipated energy with the theoretical latent energy corresponding to a pure vapor bubble reveals that the entrapped volume carries a lower effective vapor content. It is thus inferred that the entrapped vapor bubble therefore consists of a composite liquid–vapor mixture, with the liquid fraction estimated to be approximately 45–58% across the tested heat flux range. The presence of this encapsulated liquid layer explains the stability of the rising entrapped volume, which undergoes almost negligible condensation while traversing through the water layer. The insights obtained enhance the understanding of vapor transport and condensation mechanisms in immiscible fluid systems and offer guidance for the development of passive, high-performance thermal management schemes.
- 1 June 2026
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 18 (10) , 1-27
Experimental Investigation of Cylindrical Topology-Based Exhaust Thermoelectric Generator for Potential Marine Application
Waste heat recovery systems harness thermal energy that would otherwise be lost to the surroundings, converting it into useful power without additional fuel consumption. In marine vessels, nearly 50% of the total fuel energy supplied to onboard diesel power plants is wasted, with engine exhaust being the primary contributor. While the energy potential in exhaust gases is significant, the relatively low exhaust temperatures limit the effectiveness of conventional waste heat recovery systems. Thermoelectric waste heat recovery presents a promising solution for such applications, offering a compact and maintenance-free design. However, its widespread adoption is hindered by relatively low conversion efficiency and high material costs. Despite advancements in thermoelectric materials, optimizing the thermal design of exhaust heat exchangers remains a key challenge. Rectangular heat exchangers are often favored for these applications because maintaining effective thermal contact is more challenging on curved surfaces typical of cylindrical designs. This study presents the performance evaluation of a novel, scalable, cylindrical thermoelectric generator (TEG) designed to overcome some of these challenges. The proposed design enables seamless installation of a flat thermoelectric module (TEM) on a curved surface while preserving cylindrical flow, leading to enhanced thermal uniformity and improved overall efficiency of the TEG system. The performance evaluation of the test rig was carried out on a 3.5 kW diesel engine operating at a constant rpm under varying engine loads (no load, 25%, 50%, 75%, and 90%). The optimized three-row cylindrical TEG with 12 thermoelectric modules achieved a maximum matched power output of 18.7 W at 42.1 V with an efficiency of 2%. The findings underscore the potential of cylindrical TEG systems as a viable replacement for exhaust gas coolers on marine platforms, offering a sustainable and efficient approach to waste heat recovery.
- 1 June 2026
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 18 (10) , 1-27
Experimental Investigation of Cylindrical Topology-Based Exhaust Thermoelectric Generator for Potential Marine Application
Waste heat recovery systems harness thermal energy that would otherwise be lost to the surroundings, converting it into useful power without additional fuel consumption. In marine vessels, nearly 50% of the total fuel energy supplied to onboard diesel power plants is wasted, with engine exhaust being the primary contributor. While the energy potential in exhaust gases is significant, the relatively low exhaust temperatures limit the effectiveness of conventional waste heat recovery systems. Thermoelectric waste heat recovery presents a promising solution for such applications, offering a compact and maintenance-free design. However, its widespread adoption is hindered by relatively low conversion efficiency and high material costs. Despite advancements in thermoelectric materials, optimizing the thermal design of exhaust heat exchangers remains a key challenge. Rectangular heat exchangers are often favored for these applications because maintaining effective thermal contact is more challenging on curved surfaces typical of cylindrical designs. This study presents the performance evaluation of a novel, scalable, cylindrical thermoelectric generator (TEG) designed to overcome some of these challenges. The proposed design enables seamless installation of a flat thermoelectric module (TEM) on a curved surface while preserving cylindrical flow, leading to enhanced thermal uniformity and improved overall efficiency of the TEG system. The performance evaluation of the test rig was carried out on a 3.5 kW diesel engine operating at a constant rpm under varying engine loads (no load, 25%, 50%, 75%, and 90%). The optimized three-row cylindrical TEG with 12 thermoelectric modules achieved a maximum matched power output of 18.7 W at 42.1 V with an efficiency of 2%. The findings underscore the potential of cylindrical TEG systems as a viable replacement for exhaust gas coolers on marine platforms, offering a sustainable and efficient approach to waste heat recovery.
- Open Access
- 26 May 2026
- Published by Elsevier in SSRN Electronic Journal
Gradients-Based Measurements to Elucidate the Pool Boiling Dynamics in Binary Mixtures of Ethylene Glycol and Water
This study investigates the dynamics of a single vapor bubble during saturated nucleate pool boiling of non-azeotropic ethylene glycol (EG)-water mixtures under atmospheric pressure. Experiments were performed using three EG grades, Mono-EG (MW = 62.07 g/mol), EG-400 (MW = ~400 g/mol), and EG-1500 (MW = ~1500 g/mol) at concentrations of 2, 5, and 10 wt.%. A high-speed gradients-based non-invasive imaging approach, namely the rainbow schlieren deflectometry technique, was employed to capture the bubble ebullition cycle with temporal and spatial resolution. Time-resolved image analysis enabled quantitative evaluation of some of the critical bubble dynamic parameters such as equivalent bubble diameter, departure frequency, base contact diameter and dynamic contact angle throughout the cycle of bubble from its nucleation, growth, and detachment. Additionally, the temporal evolution of dominant forces governing bubble dynamics including buoyancy, surface tension, interfacial pressure, and inertial growth forces was evaluated to understand the mechanistic influence of EG molecular weight and its concentration.The results show that increasing EG concentration and molecular weight suppresses bubble growth and reduces departure diameter due to enhanced interfacial mass transfer resistance and reduced thermal transport at the vapor-liquid interface. In contrast, bubble departure frequency increases significantly compared to pure water, indicating accelerated nucleation departure cycles. These changes are attributed to modifications in intermolecular interactions and hydrogen-bonding networks, as confirmed by FTIR and TGA analyses. The findings provide new mechanistic insights into diffusion-controlled bubble dynamics in multicomponent systems and offer a scientific basis for designing optimized working fluids for advanced thermal management and energy applications.
- 26 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessGradients-Based Measurements to Elucidate the Pool Boiling Dynamics in Binary Mixtures of Ethylene Glycol and Water
This study investigates the dynamics of a single vapor bubble during saturated nucleate pool boiling of non-azeotropic ethylene glycol (EG)-water mixtures under atmospheric pressure. Experiments were performed using three EG grades, Mono-EG (MW = 62.07 g/mol), EG-400 (MW = ~400 g/mol), and EG-1500 (MW = ~1500 g/mol) at concentrations of 2, 5, and 10 wt.%. A high-speed gradients-based non-invasive imaging approach, namely the rainbow schlieren deflectometry technique, was employed to capture the bubble ebullition cycle with temporal and spatial resolution. Time-resolved image analysis enabled quantitative evaluation of some of the critical bubble dynamic parameters such as equivalent bubble diameter, departure frequency, base contact diameter and dynamic contact angle throughout the cycle of bubble from its nucleation, growth, and detachment. Additionally, the temporal evolution of dominant forces governing bubble dynamics including buoyancy, surface tension, interfacial pressure, and inertial growth forces was evaluated to understand the mechanistic influence of EG molecular weight and its concentration.The results show that increasing EG concentration and molecular weight suppresses bubble growth and reduces departure diameter due to enhanced interfacial mass transfer resistance and reduced thermal transport at the vapor-liquid interface. In contrast, bubble departure frequency increases significantly compared to pure water, indicating accelerated nucleation departure cycles. These changes are attributed to modifications in intermolecular interactions and hydrogen-bonding networks, as confirmed by FTIR and TGA analyses. The findings provide new mechanistic insights into diffusion-controlled bubble dynamics in multicomponent systems and offer a scientific basis for designing optimized working fluids for advanced thermal management and energy applications.
- Open Access
- 10 March 2026
- Published by Elsevier in SSRN Electronic Journal
Mitigating diffusion limited heat transfer effects through controlled bubble departure during buoyancy-opposed nucleate pool boiling: Whole field measurements
Downward-facing pool boiling with buoyancy-opposed conditions holds importance in nuclear safety applications such as external reactor vessel cooling (ERVC). Despite extensive research, existing studies have primarily focused on film boiling, elongated vapor slug dynamics, and nucleate boiling involving multiple interacting bubbles, largely relying on high-speed visualization and providing limited insight into the associated thermal field. In the present work, a comprehensive experimental investigation of single bubble dynamics and coupled thermal transport on a downward facing heated surface is carried out using Rainbow Schlieren Deflectometry (RSD). This optical technique enables simultaneous, non-intrusive and time-resolved measurements of vapor bubble dynamics and two-dimensional temperature gradients near the heater surface and around the vapor bubble. Experiments were performed under subcooled pool conditions (ΔTsub = 3 K) at heat fluxes of 10 and 20 kW/m². Time-resolved measurements of bubble equivalent diameter, base diameter and aspect ratio are obtained to characterize bubble growth and deformation under buoyancy-opposed conditions. The reconstructed temperature and its gradient fields reveal pronounced thermal boundary layer development near the heater surface, with maximum near wall temperature gradients increasing from 15,000 °C/m at 10 kW/m² to 20,000 °C/m at 20 kW/m². Heat partitioning analysis indicates that both evaporative and condensation heat transfer components increase with heat flux, with the evaporative contribution showing an enhancement of nearly 150% at higher heat flux. Furthermore, a noticeable enhancement in the local heat transfer coefficient is observed after bubble departure compared to before bubble nucleation. The heat transfer coefficient attains higher values after the bubble leaves the heater surface due to turbulence, with average increases of approximately 9% and 13% at heat fluxes of 10 and 20 kW/m², respectively.
- 10 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMitigating diffusion limited heat transfer effects through controlled bubble departure during buoyancy-opposed nucleate pool boiling: Whole field measurements
Downward-facing pool boiling with buoyancy-opposed conditions holds importance in nuclear safety applications such as external reactor vessel cooling (ERVC). Despite extensive research, existing studies have primarily focused on film boiling, elongated vapor slug dynamics, and nucleate boiling involving multiple interacting bubbles, largely relying on high-speed visualization and providing limited insight into the associated thermal field. In the present work, a comprehensive experimental investigation of single bubble dynamics and coupled thermal transport on a downward facing heated surface is carried out using Rainbow Schlieren Deflectometry (RSD). This optical technique enables simultaneous, non-intrusive and time-resolved measurements of vapor bubble dynamics and two-dimensional temperature gradients near the heater surface and around the vapor bubble. Experiments were performed under subcooled pool conditions (ΔTsub = 3 K) at heat fluxes of 10 and 20 kW/m². Time-resolved measurements of bubble equivalent diameter, base diameter and aspect ratio are obtained to characterize bubble growth and deformation under buoyancy-opposed conditions. The reconstructed temperature and its gradient fields reveal pronounced thermal boundary layer development near the heater surface, with maximum near wall temperature gradients increasing from 15,000 °C/m at 10 kW/m² to 20,000 °C/m at 20 kW/m². Heat partitioning analysis indicates that both evaporative and condensation heat transfer components increase with heat flux, with the evaporative contribution showing an enhancement of nearly 150% at higher heat flux. Furthermore, a noticeable enhancement in the local heat transfer coefficient is observed after bubble departure compared to before bubble nucleation. The heat transfer coefficient attains higher values after the bubble leaves the heater surface due to turbulence, with average increases of approximately 9% and 13% at heat fluxes of 10 and 20 kW/m², respectively.
- Open Access
- 12 February 2026
- Published by Elsevier in AI Thermal Fluids
- Vol. 5
Two-stage machine learning framework for investigating vapor bubble dynamics in nucleate flow boiling
- 12 February 2026
- Published by Elsevier in AI Thermal Fluids
- Vol. 5
Open AccessTwo-stage machine learning framework for investigating vapor bubble dynamics in nucleate flow boiling
- Open Access
- 6 February 2026
- Published by Elsevier in SSRN Electronic Journal
On the coupled investigation of spatio-temporal thermal signatures of thin metallic substrate and vapor bubble dynamics in nucleate flow boiling regime
Flow boiling has emerged as a crucial heat transfer mechanism for advanced thermal management systems owing to its ability to combine nucleate boiling efficiency with forced convection. However, detailed understanding of localized heat transfer mechanisms, particularly the interplay between microlayer evaporation, condensation, and superheated liquid evaporation, remains limited due to the challenges of simultaneous thermal and vapor bubble dynamics measurements. In this study, a comprehensive experimental investigation of subcooled flow boiling is performed in a vertically oriented small length scale channel using a stainless-steel foil heater at a Reynolds number of 1200 and subcooling of 6 K. The experiments integrate rainbow schlieren deflectometry (RSD) and infrared (IR) thermography to simultaneously visualize bubble dynamics and capture spatiotemporal surface temperature distributions beneath the vapor bubble. The results reveal significant asymmetry in temperature and heat flux fields induced by the flow inertia, with the peak local heat flux reaching approximately 1.8 MW/m2. Detailed energy balance analysis further quantifies the individual contributions of microlayer evaporation, superheated liquid evaporation, and condensation to the total heat transfer. The findings demonstrate that microlayer evaporation remains the dominant mechanism at high heat flux levels, while condensation effects become increasingly important during the late growth phase under subcooled conditions. This integrated RSD–IR thermography approach provides new insights into the transient two-phase heat transfer mechanisms during flow boiling on metallic substrates and establishes a framework for future model validation and design optimization of high heat flux thermal systems.
- 6 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOn the coupled investigation of spatio-temporal thermal signatures of thin metallic substrate and vapor bubble dynamics in nucleate flow boiling regime
Flow boiling has emerged as a crucial heat transfer mechanism for advanced thermal management systems owing to its ability to combine nucleate boiling efficiency with forced convection. However, detailed understanding of localized heat transfer mechanisms, particularly the interplay between microlayer evaporation, condensation, and superheated liquid evaporation, remains limited due to the challenges of simultaneous thermal and vapor bubble dynamics measurements. In this study, a comprehensive experimental investigation of subcooled flow boiling is performed in a vertically oriented small length scale channel using a stainless-steel foil heater at a Reynolds number of 1200 and subcooling of 6 K. The experiments integrate rainbow schlieren deflectometry (RSD) and infrared (IR) thermography to simultaneously visualize bubble dynamics and capture spatiotemporal surface temperature distributions beneath the vapor bubble. The results reveal significant asymmetry in temperature and heat flux fields induced by the flow inertia, with the peak local heat flux reaching approximately 1.8 MW/m2. Detailed energy balance analysis further quantifies the individual contributions of microlayer evaporation, superheated liquid evaporation, and condensation to the total heat transfer. The findings demonstrate that microlayer evaporation remains the dominant mechanism at high heat flux levels, while condensation effects become increasingly important during the late growth phase under subcooled conditions. This integrated RSD–IR thermography approach provides new insights into the transient two-phase heat transfer mechanisms during flow boiling on metallic substrates and establishes a framework for future model validation and design optimization of high heat flux thermal systems.