Michel Meisterhans
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michel Meisterhans has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Armando Hoch
Department of Orthopedics, Balgrist University Hospital University of Zurich Zurich Switzerland
3 shared publications - Christoph Zindel
Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zürich, Switzerland
3 shared publications Lazaros Vlachopoulos
Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zürich, Switzerland
3 shared publicationsPatrick O. Zingg
Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
3 shared publicationsSandro F. Fucentese
Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zürich, Switzerland
3 shared publicationsChristoph Zindel
Univ Zurich, Balgrist Univ Hosp, Dept Orthoped, Forchstr 340, CH-8008 Zurich, Switzerland
2 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (10)
Correlation of Radial and Ulnar Shaft Bowing Using the 3D Central Line Method
Forearm rotation depends on the multiplanar bowing of the radius and ulna. Despite the importance of the fundamental 3D anatomic understanding of the forearm for fracture fixation or implant design, all morphological studies have applied only two‐dimensional methods rather than analyzing the true full 3D space. No study investigated the intra‐pair relation of ulna/radius either. Therefore, we processed CT scans of 30 healthy forearms into 3D models. Each bone was divided into 10 segments along the rotation axis, creating 11 cross‐sections with central points. Connecting these central points yielded the Central‐Line. Bowing was quantified as the Bowing‐Index (area under the Central‐Line). Bowing was analyzed in ap, sagittal and the newly defined Main‐Deformity‐Axis (MDA) plane. Maximal radial deviation averaged 6.4 ± 2.3 mm in frontal, 1.3 ± 3.3 mm sagittal, and 7.2 ± 1.8 mm in MDA plane over all forearms. Maximal ulnar deviation was greater with 8.2 ± 2.9 mm frontal, 9.5 ± 1.7 mm sagittal, and 12.3 ± 2.1 mm in MDA. MDA orientation angle (angular tilt in the dorso‐radial direction in the axial plane) was dorso‐radial, with significantly larger out‐of‐plane bowing in the ulna (60.4° vs. 15.0°; p < 0.01), yielding an average intra‐bone‐pair‐difference of 45.5° ± 33.0°. A negative correlation was found between radius and ulna MDA angles ( r = −0.40, p = 0.030). The Bowing Index was higher in the ulna across all planes ( p ≤ 0.011), with a significant negative correlation between Ulna and Radius (MDA plane, r = −0.38, p = 0.036). Distal ulna analysis revealed consistent dorsal and slight ulnar tilt. The Central Line Method enables 3D characterization of forearm bowing, identifying deformity planes beyond frontal/sagittal axes. For the first time, significant negative correlations between radial and ulnar bowing were demonstrated. These insights hold clinical relevance for fracture fixation, osteotomy planning, and implant design.
- 20 October 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (10)
Open AccessCorrelation of Radial and Ulnar Shaft Bowing Using the 3D Central Line Method
Forearm rotation depends on the multiplanar bowing of the radius and ulna. Despite the importance of the fundamental 3D anatomic understanding of the forearm for fracture fixation or implant design, all morphological studies have applied only two‐dimensional methods rather than analyzing the true full 3D space. No study investigated the intra‐pair relation of ulna/radius either. Therefore, we processed CT scans of 30 healthy forearms into 3D models. Each bone was divided into 10 segments along the rotation axis, creating 11 cross‐sections with central points. Connecting these central points yielded the Central‐Line. Bowing was quantified as the Bowing‐Index (area under the Central‐Line). Bowing was analyzed in ap, sagittal and the newly defined Main‐Deformity‐Axis (MDA) plane. Maximal radial deviation averaged 6.4 ± 2.3 mm in frontal, 1.3 ± 3.3 mm sagittal, and 7.2 ± 1.8 mm in MDA plane over all forearms. Maximal ulnar deviation was greater with 8.2 ± 2.9 mm frontal, 9.5 ± 1.7 mm sagittal, and 12.3 ± 2.1 mm in MDA. MDA orientation angle (angular tilt in the dorso‐radial direction in the axial plane) was dorso‐radial, with significantly larger out‐of‐plane bowing in the ulna (60.4° vs. 15.0°; p < 0.01), yielding an average intra‐bone‐pair‐difference of 45.5° ± 33.0°. A negative correlation was found between radius and ulna MDA angles ( r = −0.40, p = 0.030). The Bowing Index was higher in the ulna across all planes ( p ≤ 0.011), with a significant negative correlation between Ulna and Radius (MDA plane, r = −0.38, p = 0.036). Distal ulna analysis revealed consistent dorsal and slight ulnar tilt. The Central Line Method enables 3D characterization of forearm bowing, identifying deformity planes beyond frontal/sagittal axes. For the first time, significant negative correlations between radial and ulnar bowing were demonstrated. These insights hold clinical relevance for fracture fixation, osteotomy planning, and implant design.
- Open Access
- 26 June 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (3) , e70813
Promising performance of locally deployed large language models for postoperative orthopaedic patient questions: An In Silico analysis
Purpose: Generative artificial intelligence (AI), particularly large language models (LLMs), are increasingly utilised in healthcare. While this may reduce the initial workload of healthcare professionals, unvalidated model outputs can pose a relevant risk to patient safety if they are inaccurate, incomplete or inconsistent with recommendations. This study evaluates and compares the performance of local and commercial LLMs on patient questions to inform institutional strategies for patient communication and management. Methods: Twenty postoperative patient questions were constructed and posed to GPT‐5, Claude 4.5 Sonnet (commercial models) and GPT‐OSS, Apertus (locally hosted). Responses were assessed using the QUEST framework evaluating quality, understanding, expression, safety and trust. Four blinded reviewers, two board‐certified fellowship‐trained orthopaedic surgeons and two orthopaedic surgery residents assessed responses. Overall model performance was compared using the Friedman test, with Wilcoxon signed‐rank tests for pairwise post hoc comparisons. Metrics where lower values indicate better performance were inverted so that higher values uniformly represent better performance across all metrics. Results: The highest overall performance scores were observed for Claude 4.5 Sonnet (mean 0.949, SD 0.124) and GPT‐5 (0.937, 0.142), followed by GPT‐OSS (0.873, 0.189), while Apertus performed worst (0.693, 0.317). On QUEST dimensions, GPT‐5 and Claude 4.5 Sonnet achieved consistently high ratings, whereas Apertus scored lower across information quality, reasoning and expression. Safety‐relevant issues were concentrated in Apertus, with harmful content and fabrication each occurring in 22.5% of evaluated ratings (18/80). At the output level, this corresponded to harmful content in 9/20 unique model responses, and fabrication in 11/20 unique model responses. Inter‐rater agreement was moderate (overall Fleiss' κ ≈ 0.50). Conclusions: In this structured evaluation setting, commercial LLMs showed higher overall performance and fewer safety‐relevant ratings, but they remain externally controlled. Achieving privacy‐compliant, real‐time clinical integration will require advancing local LLMs through fine‐tuning, rigorous validation and robust safety guardrails. Level of Evidence: Level V.
- 26 June 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (3) , e70813
Open AccessPromising performance of locally deployed large language models for postoperative orthopaedic patient questions: An In Silico analysis
Purpose: Generative artificial intelligence (AI), particularly large language models (LLMs), are increasingly utilised in healthcare. While this may reduce the initial workload of healthcare professionals, unvalidated model outputs can pose a relevant risk to patient safety if they are inaccurate, incomplete or inconsistent with recommendations. This study evaluates and compares the performance of local and commercial LLMs on patient questions to inform institutional strategies for patient communication and management. Methods: Twenty postoperative patient questions were constructed and posed to GPT‐5, Claude 4.5 Sonnet (commercial models) and GPT‐OSS, Apertus (locally hosted). Responses were assessed using the QUEST framework evaluating quality, understanding, expression, safety and trust. Four blinded reviewers, two board‐certified fellowship‐trained orthopaedic surgeons and two orthopaedic surgery residents assessed responses. Overall model performance was compared using the Friedman test, with Wilcoxon signed‐rank tests for pairwise post hoc comparisons. Metrics where lower values indicate better performance were inverted so that higher values uniformly represent better performance across all metrics. Results: The highest overall performance scores were observed for Claude 4.5 Sonnet (mean 0.949, SD 0.124) and GPT‐5 (0.937, 0.142), followed by GPT‐OSS (0.873, 0.189), while Apertus performed worst (0.693, 0.317). On QUEST dimensions, GPT‐5 and Claude 4.5 Sonnet achieved consistently high ratings, whereas Apertus scored lower across information quality, reasoning and expression. Safety‐relevant issues were concentrated in Apertus, with harmful content and fabrication each occurring in 22.5% of evaluated ratings (18/80). At the output level, this corresponded to harmful content in 9/20 unique model responses, and fabrication in 11/20 unique model responses. Inter‐rater agreement was moderate (overall Fleiss' κ ≈ 0.50). Conclusions: In this structured evaluation setting, commercial LLMs showed higher overall performance and fewer safety‐relevant ratings, but they remain externally controlled. Achieving privacy‐compliant, real‐time clinical integration will require advancing local LLMs through fine‐tuning, rigorous validation and robust safety guardrails. Level of Evidence: Level V.
- Open Access
- 21 November 2025
- Published by Elsevier in Gait & Posture
- Vol. 124, 110061
The effect of experimentally-induced gluteal muscle paralysis on joint kinematics, reaction forces and dynamic balance performance during lunges
- 21 November 2025
- Published by Elsevier in Gait & Posture
- Vol. 124, 110061
Open AccessThe effect of experimentally-induced gluteal muscle paralysis on joint kinematics, reaction forces and dynamic balance performance during lunges
- Open Access
- 14 October 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (12) , 5773-5779
Biomechanical effects of incremental resection of the lumbar superior articular process using an endoscopic approach
Purpose: This study aimed to evaluate the biomechanical effects of progressively removing parts of the facet joint (mainly the superior articular process (SAP)) in cadaveric models via the typical endoscopic posterolateral route. Materials and methods: Twelve spinal segments were biomechanically evaluated in a load-controlled study to assess the impact of the endoscopic trans superior articular process (transSAP) approach on segmental range of motion (ROM). ROM was compared between the native state and after the transSAP approach, using two drill hole sizes (4 mm and 8 mm). The segments were tested under various loading conditions: flexion-extension (FE), lateral shear (LS), lateral bending (LB), anteroposterior shear (AS), and axial rotation (AR). Results: The ROM of the vertebral segments did not change significantly across most movement directions between the native, intact state, and the two endoscopic approaches. A significant increase in ROM was observed in AS compared to the native state: 1.3° (SD: 0.63) versus 1.34° (0.65; p = 0.007) for the 4 mm transSAP, and 1.4° (0.71; p = 0.04) for the 8 mm transSAP. Additionally, in FE, the 8 mm transSAP approach showed a 5% increase in ROM compared to the 4 mm approach ( p = 0.03). No significant differences were observed in the other loading conditions. Conclusion: The transSAP approach, requiring substantial resection of the SAP and potentially parts of the inferior articular process (IAP), may be performed without necessarily compromising segmental stability and function.
- 14 October 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (12) , 5773-5779
Open AccessBiomechanical effects of incremental resection of the lumbar superior articular process using an endoscopic approach
Purpose: This study aimed to evaluate the biomechanical effects of progressively removing parts of the facet joint (mainly the superior articular process (SAP)) in cadaveric models via the typical endoscopic posterolateral route. Materials and methods: Twelve spinal segments were biomechanically evaluated in a load-controlled study to assess the impact of the endoscopic trans superior articular process (transSAP) approach on segmental range of motion (ROM). ROM was compared between the native state and after the transSAP approach, using two drill hole sizes (4 mm and 8 mm). The segments were tested under various loading conditions: flexion-extension (FE), lateral shear (LS), lateral bending (LB), anteroposterior shear (AS), and axial rotation (AR). Results: The ROM of the vertebral segments did not change significantly across most movement directions between the native, intact state, and the two endoscopic approaches. A significant increase in ROM was observed in AS compared to the native state: 1.3° (SD: 0.63) versus 1.34° (0.65; p = 0.007) for the 4 mm transSAP, and 1.4° (0.71; p = 0.04) for the 8 mm transSAP. Additionally, in FE, the 8 mm transSAP approach showed a 5% increase in ROM compared to the 4 mm approach ( p = 0.03). No significant differences were observed in the other loading conditions. Conclusion: The transSAP approach, requiring substantial resection of the SAP and potentially parts of the inferior articular process (IAP), may be performed without necessarily compromising segmental stability and function.
- Open Access
- 1 April 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (2) , e70274
Change of force and lever arm of the hip abductors after subtrochanteric de‐/rotational osteotomy
Purpose: Previous studies have shown that rotational osteotomy of the femur reliably corrects anatomical torsion but may result in a ±1 cm antero‐posterior shift of the greater trochanter (GT) per 10° of torsional correction. It is unclear whether an inadvertent displacement of the GT following surgical treatment of femoral maltorsion affects the hip abductors in a clinically relevant manner and needs to be addressed by compensatory digastric trochanteric osteotomy. The aim of this study was to investigate the influence of rotational subtrochanteric osteotomy on hip abductor force generation using three‐dimensional (3D) surface models.Methods: A 3D statistical shape model (SSM) of a hip/femur was used. From a baseline value of 12°, the SSM was derotated/rotated in 10° increments, creating five different scenarios of anatomical femoral torsion: 32°, 22°, 12° (baseline), 2°, −8° (corresponding to 8° of retro torsion). The origins and insertions of the gluteus medius (GMed) and minimus (GMin) muscles were created. The hip abductor moment was defined as the muscle force (of the hip abductor muscles) multiplied by the force ratio in the direction of abduction (FRDA) multiplied by the lever arm. All values were measured, whereas muscle strength was defined as the length of the muscle fibres in relation to their optimal length.Results: Results indicated minimal changes in muscle length (±1.2%) and FRDA (1.7% to −7%) for GMed und GMin across all scenarios. However, lever arm demonstrated variations (21% to −10%), with an increase observed for derotational osteotomies and a decrease for rotational osteotomies.Conclusion: Subtrochanteric osteotomy in the management of femoral maltorsion affects the hip abduction moment solely through the altered lever arm. A 20° derotation for increased femoral torsion (FT) corresponds to a 20% increase in abduction force of the GMed (improved lever arm), whereas a 20° rotation for decreased FT reduces the abduction force by 10%.Level of Evidence: Level III, diagnostic.
- 1 April 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (2) , e70274
Open AccessChange of force and lever arm of the hip abductors after subtrochanteric de‐/rotational osteotomy
Purpose: Previous studies have shown that rotational osteotomy of the femur reliably corrects anatomical torsion but may result in a ±1 cm antero‐posterior shift of the greater trochanter (GT) per 10° of torsional correction. It is unclear whether an inadvertent displacement of the GT following surgical treatment of femoral maltorsion affects the hip abductors in a clinically relevant manner and needs to be addressed by compensatory digastric trochanteric osteotomy. The aim of this study was to investigate the influence of rotational subtrochanteric osteotomy on hip abductor force generation using three‐dimensional (3D) surface models.Methods: A 3D statistical shape model (SSM) of a hip/femur was used. From a baseline value of 12°, the SSM was derotated/rotated in 10° increments, creating five different scenarios of anatomical femoral torsion: 32°, 22°, 12° (baseline), 2°, −8° (corresponding to 8° of retro torsion). The origins and insertions of the gluteus medius (GMed) and minimus (GMin) muscles were created. The hip abductor moment was defined as the muscle force (of the hip abductor muscles) multiplied by the force ratio in the direction of abduction (FRDA) multiplied by the lever arm. All values were measured, whereas muscle strength was defined as the length of the muscle fibres in relation to their optimal length.Results: Results indicated minimal changes in muscle length (±1.2%) and FRDA (1.7% to −7%) for GMed und GMin across all scenarios. However, lever arm demonstrated variations (21% to −10%), with an increase observed for derotational osteotomies and a decrease for rotational osteotomies.Conclusion: Subtrochanteric osteotomy in the management of femoral maltorsion affects the hip abduction moment solely through the altered lever arm. A 20° derotation for increased femoral torsion (FT) corresponds to a 20% increase in abduction force of the GMed (improved lever arm), whereas a 20° rotation for decreased FT reduces the abduction force by 10%.Level of Evidence: Level III, diagnostic.
- Open Access
- 10 December 2024
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 12 (12)
Optimizing Reduction Guide Stability in Osteotomy Using Patient-Specific Instrumentation: A Basic Guideline
Background: The use of patient-specific instruments (PSIs) for osteotomies is becoming more popular in orthopaedic surgery for correcting mechanical axis and posttraumatic deformities. However, the PSI reduction guides have great potential for intraoperative deformation, which adversely affects the accuracy of the procedure. Purpose: To conduct a finite element analysis (FEA) to analyze different design parameters to improve the intraoperative stability of the reduction guides. Study Design: Descriptive laboratory study. Methods: A reduction guide with a rectangular cross section and four 4-mm K-wire slots was simplified, and the following parameters were modified: width, height, profile design, K-wire thickness, and positions. Bending and torsional moments were applied to the guide construct and guide deformation and equivalent stress were determined using FEA. Results: Increasing the profile height by 25% resulted in a 44% reduction in guide deformation for bending (37% for torsion). A 25% increase in profile width led to an 18% deformation reduction for bending (22% for torsion). Transverse K-wire slots resulted in 51% less deformation in torsion compared with longitudinally oriented slots. Placing the central K-wire slots 25% closer to the osteotomy reduced guide deformation by 20% for bending and 11% for torsion. Conclusion: The most effective methods to increase reduction guide stability are to increase the guide height and reduce the central K-wire distance to the osteotomy. Clinical Relevance: When performing opening or closing wedge osteotomies, which mainly involve bending of the guide, a high-profile guide and longitudinally oriented K-wire slots should be used. When torque is expected as in rotational osteotomies, the K-wire holes in guides should be oriented transversely to reduce intraoperative deformation.
- 10 December 2024
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 12 (12)
Open AccessOptimizing Reduction Guide Stability in Osteotomy Using Patient-Specific Instrumentation: A Basic Guideline
Background: The use of patient-specific instruments (PSIs) for osteotomies is becoming more popular in orthopaedic surgery for correcting mechanical axis and posttraumatic deformities. However, the PSI reduction guides have great potential for intraoperative deformation, which adversely affects the accuracy of the procedure. Purpose: To conduct a finite element analysis (FEA) to analyze different design parameters to improve the intraoperative stability of the reduction guides. Study Design: Descriptive laboratory study. Methods: A reduction guide with a rectangular cross section and four 4-mm K-wire slots was simplified, and the following parameters were modified: width, height, profile design, K-wire thickness, and positions. Bending and torsional moments were applied to the guide construct and guide deformation and equivalent stress were determined using FEA. Results: Increasing the profile height by 25% resulted in a 44% reduction in guide deformation for bending (37% for torsion). A 25% increase in profile width led to an 18% deformation reduction for bending (22% for torsion). Transverse K-wire slots resulted in 51% less deformation in torsion compared with longitudinally oriented slots. Placing the central K-wire slots 25% closer to the osteotomy reduced guide deformation by 20% for bending and 11% for torsion. Conclusion: The most effective methods to increase reduction guide stability are to increase the guide height and reduce the central K-wire distance to the osteotomy. Clinical Relevance: When performing opening or closing wedge osteotomies, which mainly involve bending of the guide, a high-profile guide and longitudinally oriented K-wire slots should be used. When torque is expected as in rotational osteotomies, the K-wire holes in guides should be oriented transversely to reduce intraoperative deformation.
- Open Access
- 20 February 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (7) , 1566-1576
Influence of offset on osseointegration in cementless total hip arthroplasty: A finite element study
Early aseptic loosening is caused by deficient osteointegration of the femoral stem due to increased micromotions and represents a common mode of failure in uncemented total hip arthroplasty (THA). This study hypothesized that a higher femoral offset, a smaller stem size and obesity increase femoral micromotion, potentially resulting in early aseptic loosening. A finite element analysis was conducted based on computed tomography segmented model of four patients who received a THA with a triple‐tapered straight stem (Size 1, 3, 6). The influence of femoral stem offset (short neck, standard, lateral), head length (S to XXL), femoral anteversion and obesity during daily activities of fast walking and stair climbing was analyzed. The micromotions for the femoral stem zones were compared to a threshold representing a value above which only partial osseointegration is expected. The minimum femoral offset configuration compared to the maximum offset configuration (short neck stem, S head vs. lateral stem, XXL head) leads to a relative mean micromotion increase of 24% for the upper stem zone. Increasing the body weight (body mass index 30–35 kg/m2) increases the micromotion by 20% for all stem zones. The obese population recorded threshold‐exceeding micromotions for stem sizes 1 and 3 for all offset configurations during stair climbing. Higher femoral offset, a smaller stem size, and higher loading due to obesity lead to an increase in micromotion between the prosthesis and proximal femur and represent a risk configuration for impaired osseointegration of a triple‐tapered straight stem, especially when these three factors are present simultaneously.
- 20 February 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (7) , 1566-1576
Open AccessInfluence of offset on osseointegration in cementless total hip arthroplasty: A finite element study
Early aseptic loosening is caused by deficient osteointegration of the femoral stem due to increased micromotions and represents a common mode of failure in uncemented total hip arthroplasty (THA). This study hypothesized that a higher femoral offset, a smaller stem size and obesity increase femoral micromotion, potentially resulting in early aseptic loosening. A finite element analysis was conducted based on computed tomography segmented model of four patients who received a THA with a triple‐tapered straight stem (Size 1, 3, 6). The influence of femoral stem offset (short neck, standard, lateral), head length (S to XXL), femoral anteversion and obesity during daily activities of fast walking and stair climbing was analyzed. The micromotions for the femoral stem zones were compared to a threshold representing a value above which only partial osseointegration is expected. The minimum femoral offset configuration compared to the maximum offset configuration (short neck stem, S head vs. lateral stem, XXL head) leads to a relative mean micromotion increase of 24% for the upper stem zone. Increasing the body weight (body mass index 30–35 kg/m2) increases the micromotion by 20% for all stem zones. The obese population recorded threshold‐exceeding micromotions for stem sizes 1 and 3 for all offset configurations during stair climbing. Higher femoral offset, a smaller stem size, and higher loading due to obesity lead to an increase in micromotion between the prosthesis and proximal femur and represent a risk configuration for impaired osseointegration of a triple‐tapered straight stem, especially when these three factors are present simultaneously.
- Open Access
- 18 January 2024
- Published by Elsevier in JSES International
- Vol. 8 (3) , 423-428
Anterior shoulder dislocation with avulsion fracture of the greater tuberosity results in reliable good outcomes after closed reduction
- 18 January 2024
- Published by Elsevier in JSES International
- Vol. 8 (3) , 423-428
Open AccessAnterior shoulder dislocation with avulsion fracture of the greater tuberosity results in reliable good outcomes after closed reduction
- Open Access
- 7 November 2023
- Published by Wolters Kluwer Health in Spine
- Vol. 49 (15) , 1052-1058
The Biomechanics of the Transpedicular Endoscopic Approach
Study Design.: Biomechanical cadaveric study. Objective.: The goal of this study was to analyze the effects of an endoscopic transpedicular approach with different drill diameters (6 and 8 mm) and compare them with the intact native side. In addition, the influence of bone quality on the resistance of the pedicle was investigated. Summary of Background Data.: Clinical studies have repeatedly highlighted the benefits of endoscopic transpedicular decompression for downmigrated lumbar disc herniations. However, the biomechanical effects on pedicle stability have not been studied up to now. Materials and Methods.: Twenty-four vertebras originating from four fresh-frozen cadavers were tested under uniaxial compression load in a ramp-to-failure test: (1) the tunneled pedicle on one side, and (2) the native pedicle on the other side. Twelve lumbar vertebrae were assigned to drill diameter of 6 mm and the other 12 to diameter of 8 mm. Results.: The median ratio of sustained force for the operated side compared with the intact contralateral side is equal to 74% (63–88) for both drill diameters combined. An 8 mm transpedicular approach recorded an axial resistance of 77% (60–88) compared with the intact contralateral side (P=0.002). A 6 mm approach resulted in an axial resistance of 72% (66–84) compared with the intact opposite side (P=0.01). No significant difference between the two different drill diameters was recorded (P=1). For all three subgroups (intact, 8 mm, 6 mm) the Hounsfield units-values and the absolute resistance force showed significant correlations (intact: ρ=0.859; PPP<0.001). Conclusion.: The transpedicular approach significantly reduces the axial resistance force of the pedicle, which may lead to pedicle fracture. Bone quality correlated positively with the absolute resistance force of the pedicle, whereas the influence of the drill hole diameter plays only a limited role.
- 7 November 2023
- Published by Wolters Kluwer Health in Spine
- Vol. 49 (15) , 1052-1058
Open AccessThe Biomechanics of the Transpedicular Endoscopic Approach
Study Design.: Biomechanical cadaveric study. Objective.: The goal of this study was to analyze the effects of an endoscopic transpedicular approach with different drill diameters (6 and 8 mm) and compare them with the intact native side. In addition, the influence of bone quality on the resistance of the pedicle was investigated. Summary of Background Data.: Clinical studies have repeatedly highlighted the benefits of endoscopic transpedicular decompression for downmigrated lumbar disc herniations. However, the biomechanical effects on pedicle stability have not been studied up to now. Materials and Methods.: Twenty-four vertebras originating from four fresh-frozen cadavers were tested under uniaxial compression load in a ramp-to-failure test: (1) the tunneled pedicle on one side, and (2) the native pedicle on the other side. Twelve lumbar vertebrae were assigned to drill diameter of 6 mm and the other 12 to diameter of 8 mm. Results.: The median ratio of sustained force for the operated side compared with the intact contralateral side is equal to 74% (63–88) for both drill diameters combined. An 8 mm transpedicular approach recorded an axial resistance of 77% (60–88) compared with the intact contralateral side (P=0.002). A 6 mm approach resulted in an axial resistance of 72% (66–84) compared with the intact opposite side (P=0.01). No significant difference between the two different drill diameters was recorded (P=1). For all three subgroups (intact, 8 mm, 6 mm) the Hounsfield units-values and the absolute resistance force showed significant correlations (intact: ρ=0.859; PPP<0.001). Conclusion.: The transpedicular approach significantly reduces the axial resistance force of the pedicle, which may lead to pedicle fracture. Bone quality correlated positively with the absolute resistance force of the pedicle, whereas the influence of the drill hole diameter plays only a limited role.