Optimizing Reduction Guide Stability in Osteotomy Using Patient-Specific Instrumentation: A Basic Guideline
Open Access
- 10 December 2024
- journal article
- research article
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 12 (12)
Abstract
Background: The use of patient-specific instruments (PSIs) for osteotomies is becoming more popular in orthopaedic surgery for correcting mechanical axis and posttraumatic deformities. However, the PSI reduction guides have great potential for intraoperative deformation, which adversely affects the accuracy of the procedure. Purpose: To conduct a finite element analysis (FEA) to analyze different design parameters to improve the intraoperative stability of the reduction guides. Study Design: Descriptive laboratory study. Methods: A reduction guide with a rectangular cross section and four 4-mm K-wire slots was simplified, and the following parameters were modified: width, height, profile design, K-wire thickness, and positions. Bending and torsional moments were applied to the guide construct and guide deformation and equivalent stress were determined using FEA. Results: Increasing the profile height by 25% resulted in a 44% reduction in guide deformation for bending (37% for torsion). A 25% increase in profile width led to an 18% deformation reduction for bending (22% for torsion). Transverse K-wire slots resulted in 51% less deformation in torsion compared with longitudinally oriented slots. Placing the central K-wire slots 25% closer to the osteotomy reduced guide deformation by 20% for bending and 11% for torsion. Conclusion: The most effective methods to increase reduction guide stability are to increase the guide height and reduce the central K-wire distance to the osteotomy. Clinical Relevance: When performing opening or closing wedge osteotomies, which mainly involve bending of the guide, a high-profile guide and longitudinally oriented K-wire slots should be used. When torque is expected as in rotational osteotomies, the K-wire holes in guides should be oriented transversely to reduce intraoperative deformation.Keywords
This publication has 25 references indexed in Scilit:
- Three-Dimensional Correction of Complex Ankle Deformities With Computer-Assisted Planning and Patient-Specific Surgical GuidesThe Journal of Foot and Ankle Surgery, 2017
- Computer-assisted planning and patient-specific guides for the treatment of midshaft clavicle malunionsJournal of Shoulder and Elbow Surgery, 2017
- Metal-backedversusall-polyethylene unicompartmental knee arthroplastyBone & Joint Research, 2017
- Three-dimensional corrective osteotomies of complex malunited humeral fractures using patient-specific guidesJournal of Shoulder and Elbow Surgery, 2016
- Three-dimensional postoperative accuracy of extra-articular forearm osteotomies using CT-scan based patient-specific surgical guidesBMC Musculoskeletal Disorders, 2015
- Are plasticity models required to predict relative risk of lag screw cut-out in finite element models of trochanteric fracture fixation?Journal of Biomechanics, 2014
- Preoperative, Computer Simulation-Based, Three-Dimensional Corrective Osteotomy for Cubitus Varus Deformity with Use of a Custom-Designed Surgical DeviceJournal of Bone and Joint Surgery, 2013
- Distal Radius Osteotomy with Volar Locking Plates Based on Computer SimulationClinical Orthopaedics and Related Research, 2011
- Three-Dimensional Corrective Osteotomy of Malunited Fractures of the Upper Extremity with Use of a Computer Simulation SystemJournal of Bone and Joint Surgery, 2008
- Rapid prototyping: the future of trauma surgery?2003