Christoph Zindel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christoph Zindel has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Andreas Schweizer
Department of Orthopedics Balgrist University Hospital University of Zurich Zurich Switzerland
4 shared publicationsLazaros Vlachopoulos
4 shared publicationsSandro F. Fucentese
4 shared publicationsKarl Wieser
Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
3 shared publications- Michel Meisterhans
Department of Orthopedics Balgrist University Hospital University of Zurich Zurich Switzerland
3 shared publications Sandro Hodel
3 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (10)
Correlation of Radial and Ulnar Shaft Bowing Using the 3D Central Line Method
Forearm rotation depends on the multiplanar bowing of the radius and ulna. Despite the importance of the fundamental 3D anatomic understanding of the forearm for fracture fixation or implant design, all morphological studies have applied only two‐dimensional methods rather than analyzing the true full 3D space. No study investigated the intra‐pair relation of ulna/radius either. Therefore, we processed CT scans of 30 healthy forearms into 3D models. Each bone was divided into 10 segments along the rotation axis, creating 11 cross‐sections with central points. Connecting these central points yielded the Central‐Line. Bowing was quantified as the Bowing‐Index (area under the Central‐Line). Bowing was analyzed in ap, sagittal and the newly defined Main‐Deformity‐Axis (MDA) plane. Maximal radial deviation averaged 6.4 ± 2.3 mm in frontal, 1.3 ± 3.3 mm sagittal, and 7.2 ± 1.8 mm in MDA plane over all forearms. Maximal ulnar deviation was greater with 8.2 ± 2.9 mm frontal, 9.5 ± 1.7 mm sagittal, and 12.3 ± 2.1 mm in MDA. MDA orientation angle (angular tilt in the dorso‐radial direction in the axial plane) was dorso‐radial, with significantly larger out‐of‐plane bowing in the ulna (60.4° vs. 15.0°; p < 0.01), yielding an average intra‐bone‐pair‐difference of 45.5° ± 33.0°. A negative correlation was found between radius and ulna MDA angles ( r = −0.40, p = 0.030). The Bowing Index was higher in the ulna across all planes ( p ≤ 0.011), with a significant negative correlation between Ulna and Radius (MDA plane, r = −0.38, p = 0.036). Distal ulna analysis revealed consistent dorsal and slight ulnar tilt. The Central Line Method enables 3D characterization of forearm bowing, identifying deformity planes beyond frontal/sagittal axes. For the first time, significant negative correlations between radial and ulnar bowing were demonstrated. These insights hold clinical relevance for fracture fixation, osteotomy planning, and implant design.
- 20 October 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (10)
Open AccessCorrelation of Radial and Ulnar Shaft Bowing Using the 3D Central Line Method
Forearm rotation depends on the multiplanar bowing of the radius and ulna. Despite the importance of the fundamental 3D anatomic understanding of the forearm for fracture fixation or implant design, all morphological studies have applied only two‐dimensional methods rather than analyzing the true full 3D space. No study investigated the intra‐pair relation of ulna/radius either. Therefore, we processed CT scans of 30 healthy forearms into 3D models. Each bone was divided into 10 segments along the rotation axis, creating 11 cross‐sections with central points. Connecting these central points yielded the Central‐Line. Bowing was quantified as the Bowing‐Index (area under the Central‐Line). Bowing was analyzed in ap, sagittal and the newly defined Main‐Deformity‐Axis (MDA) plane. Maximal radial deviation averaged 6.4 ± 2.3 mm in frontal, 1.3 ± 3.3 mm sagittal, and 7.2 ± 1.8 mm in MDA plane over all forearms. Maximal ulnar deviation was greater with 8.2 ± 2.9 mm frontal, 9.5 ± 1.7 mm sagittal, and 12.3 ± 2.1 mm in MDA. MDA orientation angle (angular tilt in the dorso‐radial direction in the axial plane) was dorso‐radial, with significantly larger out‐of‐plane bowing in the ulna (60.4° vs. 15.0°; p < 0.01), yielding an average intra‐bone‐pair‐difference of 45.5° ± 33.0°. A negative correlation was found between radius and ulna MDA angles ( r = −0.40, p = 0.030). The Bowing Index was higher in the ulna across all planes ( p ≤ 0.011), with a significant negative correlation between Ulna and Radius (MDA plane, r = −0.38, p = 0.036). Distal ulna analysis revealed consistent dorsal and slight ulnar tilt. The Central Line Method enables 3D characterization of forearm bowing, identifying deformity planes beyond frontal/sagittal axes. For the first time, significant negative correlations between radial and ulnar bowing were demonstrated. These insights hold clinical relevance for fracture fixation, osteotomy planning, and implant design.
- Open Access
- 6 August 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1)
Isometric points in cerclage for patellar tendon repair: a 3-dimensional, weightbearing computed tomography kinematic simulation
Purpose: The gold standard for the management of ruptured patellar tendon is the surgical repair with nonabsorbable sutures and additional reinforcement e.g. cerclage wires as described by McLaughlin in 1947. Despite the early description, the exact placement of such cerclage wires remains unclear. The aim of the study was (1) to analyze how the cerclage elongates during knee flexion and (2) to define the insertion points with the most isometric behavior at the patella and tibial tuberosity (TT). Methods: 3D simulations of 10 healthy knees in the range from 0° to 120° of flexion using weightbearing computed tomography scans were generated. 12 insertion points were defined at the patella in equal distances along the lateral and medial border from the proximal to the distal pole. 42 insertion points were defined at the tibial tuberosity (TT) in a 3.0 × 3.0 cm large grid around its center. An automatic string simulation algorithm was used to calculate the length for all possible combinations of the cerclage from 0° to 120° flexion. The most isometric combination of insertion points was found using the isometric score. Results: The most isometric insertion at the TT is distally ( p < 0.01) and towards the center of the TT ( p < 0.01). The most isometric points at the TT is located 61 mm distal to the joint line and 5 mm from the anterior border of the TT in a true lateral view fluoroscopy. The insertion on the patella is insensible, as long as the patella is not bypassed proximally ( p < 0.01). Conclusion: Elongation of patella tendon augmentation or cerclage can be reduced when choosing a distal and central insertion at the TT, while the insertion on the patella does not affect elongation as long as the patella is not by passed proximally. This might help to reduce excessive stress and prevent cerclage or augmentation failure.
- 6 August 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1)
Open AccessIsometric points in cerclage for patellar tendon repair: a 3-dimensional, weightbearing computed tomography kinematic simulation
Purpose: The gold standard for the management of ruptured patellar tendon is the surgical repair with nonabsorbable sutures and additional reinforcement e.g. cerclage wires as described by McLaughlin in 1947. Despite the early description, the exact placement of such cerclage wires remains unclear. The aim of the study was (1) to analyze how the cerclage elongates during knee flexion and (2) to define the insertion points with the most isometric behavior at the patella and tibial tuberosity (TT). Methods: 3D simulations of 10 healthy knees in the range from 0° to 120° of flexion using weightbearing computed tomography scans were generated. 12 insertion points were defined at the patella in equal distances along the lateral and medial border from the proximal to the distal pole. 42 insertion points were defined at the tibial tuberosity (TT) in a 3.0 × 3.0 cm large grid around its center. An automatic string simulation algorithm was used to calculate the length for all possible combinations of the cerclage from 0° to 120° flexion. The most isometric combination of insertion points was found using the isometric score. Results: The most isometric insertion at the TT is distally ( p < 0.01) and towards the center of the TT ( p < 0.01). The most isometric points at the TT is located 61 mm distal to the joint line and 5 mm from the anterior border of the TT in a true lateral view fluoroscopy. The insertion on the patella is insensible, as long as the patella is not bypassed proximally ( p < 0.01). Conclusion: Elongation of patella tendon augmentation or cerclage can be reduced when choosing a distal and central insertion at the TT, while the insertion on the patella does not affect elongation as long as the patella is not by passed proximally. This might help to reduce excessive stress and prevent cerclage or augmentation failure.
- Open Access
- 1 April 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (2) , e70274
Change of force and lever arm of the hip abductors after subtrochanteric de‐/rotational osteotomy
Purpose: Previous studies have shown that rotational osteotomy of the femur reliably corrects anatomical torsion but may result in a ±1 cm antero‐posterior shift of the greater trochanter (GT) per 10° of torsional correction. It is unclear whether an inadvertent displacement of the GT following surgical treatment of femoral maltorsion affects the hip abductors in a clinically relevant manner and needs to be addressed by compensatory digastric trochanteric osteotomy. The aim of this study was to investigate the influence of rotational subtrochanteric osteotomy on hip abductor force generation using three‐dimensional (3D) surface models.Methods: A 3D statistical shape model (SSM) of a hip/femur was used. From a baseline value of 12°, the SSM was derotated/rotated in 10° increments, creating five different scenarios of anatomical femoral torsion: 32°, 22°, 12° (baseline), 2°, −8° (corresponding to 8° of retro torsion). The origins and insertions of the gluteus medius (GMed) and minimus (GMin) muscles were created. The hip abductor moment was defined as the muscle force (of the hip abductor muscles) multiplied by the force ratio in the direction of abduction (FRDA) multiplied by the lever arm. All values were measured, whereas muscle strength was defined as the length of the muscle fibres in relation to their optimal length.Results: Results indicated minimal changes in muscle length (±1.2%) and FRDA (1.7% to −7%) for GMed und GMin across all scenarios. However, lever arm demonstrated variations (21% to −10%), with an increase observed for derotational osteotomies and a decrease for rotational osteotomies.Conclusion: Subtrochanteric osteotomy in the management of femoral maltorsion affects the hip abduction moment solely through the altered lever arm. A 20° derotation for increased femoral torsion (FT) corresponds to a 20% increase in abduction force of the GMed (improved lever arm), whereas a 20° rotation for decreased FT reduces the abduction force by 10%.Level of Evidence: Level III, diagnostic.
- 1 April 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (2) , e70274
Open AccessChange of force and lever arm of the hip abductors after subtrochanteric de‐/rotational osteotomy
Purpose: Previous studies have shown that rotational osteotomy of the femur reliably corrects anatomical torsion but may result in a ±1 cm antero‐posterior shift of the greater trochanter (GT) per 10° of torsional correction. It is unclear whether an inadvertent displacement of the GT following surgical treatment of femoral maltorsion affects the hip abductors in a clinically relevant manner and needs to be addressed by compensatory digastric trochanteric osteotomy. The aim of this study was to investigate the influence of rotational subtrochanteric osteotomy on hip abductor force generation using three‐dimensional (3D) surface models.Methods: A 3D statistical shape model (SSM) of a hip/femur was used. From a baseline value of 12°, the SSM was derotated/rotated in 10° increments, creating five different scenarios of anatomical femoral torsion: 32°, 22°, 12° (baseline), 2°, −8° (corresponding to 8° of retro torsion). The origins and insertions of the gluteus medius (GMed) and minimus (GMin) muscles were created. The hip abductor moment was defined as the muscle force (of the hip abductor muscles) multiplied by the force ratio in the direction of abduction (FRDA) multiplied by the lever arm. All values were measured, whereas muscle strength was defined as the length of the muscle fibres in relation to their optimal length.Results: Results indicated minimal changes in muscle length (±1.2%) and FRDA (1.7% to −7%) for GMed und GMin across all scenarios. However, lever arm demonstrated variations (21% to −10%), with an increase observed for derotational osteotomies and a decrease for rotational osteotomies.Conclusion: Subtrochanteric osteotomy in the management of femoral maltorsion affects the hip abduction moment solely through the altered lever arm. A 20° derotation for increased femoral torsion (FT) corresponds to a 20% increase in abduction force of the GMed (improved lever arm), whereas a 20° rotation for decreased FT reduces the abduction force by 10%.Level of Evidence: Level III, diagnostic.
- Open Access
- 10 December 2024
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 12 (12)
Optimizing Reduction Guide Stability in Osteotomy Using Patient-Specific Instrumentation: A Basic Guideline
Background: The use of patient-specific instruments (PSIs) for osteotomies is becoming more popular in orthopaedic surgery for correcting mechanical axis and posttraumatic deformities. However, the PSI reduction guides have great potential for intraoperative deformation, which adversely affects the accuracy of the procedure. Purpose: To conduct a finite element analysis (FEA) to analyze different design parameters to improve the intraoperative stability of the reduction guides. Study Design: Descriptive laboratory study. Methods: A reduction guide with a rectangular cross section and four 4-mm K-wire slots was simplified, and the following parameters were modified: width, height, profile design, K-wire thickness, and positions. Bending and torsional moments were applied to the guide construct and guide deformation and equivalent stress were determined using FEA. Results: Increasing the profile height by 25% resulted in a 44% reduction in guide deformation for bending (37% for torsion). A 25% increase in profile width led to an 18% deformation reduction for bending (22% for torsion). Transverse K-wire slots resulted in 51% less deformation in torsion compared with longitudinally oriented slots. Placing the central K-wire slots 25% closer to the osteotomy reduced guide deformation by 20% for bending and 11% for torsion. Conclusion: The most effective methods to increase reduction guide stability are to increase the guide height and reduce the central K-wire distance to the osteotomy. Clinical Relevance: When performing opening or closing wedge osteotomies, which mainly involve bending of the guide, a high-profile guide and longitudinally oriented K-wire slots should be used. When torque is expected as in rotational osteotomies, the K-wire holes in guides should be oriented transversely to reduce intraoperative deformation.
- 10 December 2024
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 12 (12)
Open AccessOptimizing Reduction Guide Stability in Osteotomy Using Patient-Specific Instrumentation: A Basic Guideline
Background: The use of patient-specific instruments (PSIs) for osteotomies is becoming more popular in orthopaedic surgery for correcting mechanical axis and posttraumatic deformities. However, the PSI reduction guides have great potential for intraoperative deformation, which adversely affects the accuracy of the procedure. Purpose: To conduct a finite element analysis (FEA) to analyze different design parameters to improve the intraoperative stability of the reduction guides. Study Design: Descriptive laboratory study. Methods: A reduction guide with a rectangular cross section and four 4-mm K-wire slots was simplified, and the following parameters were modified: width, height, profile design, K-wire thickness, and positions. Bending and torsional moments were applied to the guide construct and guide deformation and equivalent stress were determined using FEA. Results: Increasing the profile height by 25% resulted in a 44% reduction in guide deformation for bending (37% for torsion). A 25% increase in profile width led to an 18% deformation reduction for bending (22% for torsion). Transverse K-wire slots resulted in 51% less deformation in torsion compared with longitudinally oriented slots. Placing the central K-wire slots 25% closer to the osteotomy reduced guide deformation by 20% for bending and 11% for torsion. Conclusion: The most effective methods to increase reduction guide stability are to increase the guide height and reduce the central K-wire distance to the osteotomy. Clinical Relevance: When performing opening or closing wedge osteotomies, which mainly involve bending of the guide, a high-profile guide and longitudinally oriented K-wire slots should be used. When torque is expected as in rotational osteotomies, the K-wire holes in guides should be oriented transversely to reduce intraoperative deformation.
- Open Access
- 24 November 2024
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 52 (14) , 3578-3586
Accuracy of Combined High Tibial Slope Correction Osteotomy Using 3-Dimensional-Planned Patient-Specific Instrumentation
Background: If an increased posterior tibial slope (PTS) and concomitant unicompartmental osteoarthritis are present, a simultaneous sagittal (slope) and coronal correcting high tibial osteotomy has been recommended. However, no study has investigated the accuracy of such combined high tibial slope correction osteotomies. Purpose: (1) To report the accuracy of navigated high tibial slope correction osteotomies using patient-specific instruments (PSI) and (2) to analyze the influence of an open wedge osteotomy (OWO) versus a closed wedge osteotomy (CWO) and the hinge axis angle (HAA) on the accuracy of the PTS correction. Study Design: Cohort study; Level of evidence, 3. Methods: All PSI PTS-reducing osteotomies performed at 1 institution between 2019 and 2022 were reviewed. Three-dimensional (3D) accuracy was defined as the mean absolute 3D angular difference between the planned and achieved surgical correction (in degrees) in 3D models of computed tomography data. The influence of OWO versus CWO and the HAA on the reported accuracy was analyzed and a cutoff defined using receiver operating characteristic curve analysis. Results: Eighteen patients who underwent a slope-reducing CWO (n = 9) or OWO (n = 9) were included. The 3D accuracy for PTS was 2.3°± 1.1° (mean ± SD), with CWO being more accurate than OWO (1.4°± 0.9° vs 3.1°± 0.6°; P < .01). Accuracy strongly correlated with the HAA ( r = 0.788; P < .01). An HAA >38.9° predicted a PTS error >2° (odds ratio, 1.12 [95% CI, 1.04-1.20; P = .004]; area under the curve, 0.95 [95% CI, 0.89-1.00; P < .001]) corresponding to a coronal/sagittal correction of 0.8:1. Conclusion: Slope-reducing osteotomy can accurately be achieved using PSI. CWO demonstrated an increased accuracy when compared with OWO, which strongly depended on the HAA. With an aim of combined PTS and coronal correction, CWO should be considered the primary choice for accurate slope reduction with a coronal/sagittal correction cutoff of 0.8:1 (HAA, 38.9°).
- 24 November 2024
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 52 (14) , 3578-3586
Open AccessAccuracy of Combined High Tibial Slope Correction Osteotomy Using 3-Dimensional-Planned Patient-Specific Instrumentation
Background: If an increased posterior tibial slope (PTS) and concomitant unicompartmental osteoarthritis are present, a simultaneous sagittal (slope) and coronal correcting high tibial osteotomy has been recommended. However, no study has investigated the accuracy of such combined high tibial slope correction osteotomies. Purpose: (1) To report the accuracy of navigated high tibial slope correction osteotomies using patient-specific instruments (PSI) and (2) to analyze the influence of an open wedge osteotomy (OWO) versus a closed wedge osteotomy (CWO) and the hinge axis angle (HAA) on the accuracy of the PTS correction. Study Design: Cohort study; Level of evidence, 3. Methods: All PSI PTS-reducing osteotomies performed at 1 institution between 2019 and 2022 were reviewed. Three-dimensional (3D) accuracy was defined as the mean absolute 3D angular difference between the planned and achieved surgical correction (in degrees) in 3D models of computed tomography data. The influence of OWO versus CWO and the HAA on the reported accuracy was analyzed and a cutoff defined using receiver operating characteristic curve analysis. Results: Eighteen patients who underwent a slope-reducing CWO (n = 9) or OWO (n = 9) were included. The 3D accuracy for PTS was 2.3°± 1.1° (mean ± SD), with CWO being more accurate than OWO (1.4°± 0.9° vs 3.1°± 0.6°; P < .01). Accuracy strongly correlated with the HAA ( r = 0.788; P < .01). An HAA >38.9° predicted a PTS error >2° (odds ratio, 1.12 [95% CI, 1.04-1.20; P = .004]; area under the curve, 0.95 [95% CI, 0.89-1.00; P < .001]) corresponding to a coronal/sagittal correction of 0.8:1. Conclusion: Slope-reducing osteotomy can accurately be achieved using PSI. CWO demonstrated an increased accuracy when compared with OWO, which strongly depended on the HAA. With an aim of combined PTS and coronal correction, CWO should be considered the primary choice for accurate slope reduction with a coronal/sagittal correction cutoff of 0.8:1 (HAA, 38.9°).
- Open Access
- 4 June 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
Dome versus single-cut osteotomies for correction of long bone deformities—technical considerations
Corrective osteotomy allows to improve joint loading, pain and function. In complex deformities, the biggest challenge is to define the optimal surgical solution, while considering anatomical, technical and biomechanical factors. While the single-cut osteotomy (SCOT) and focal dome osteotomy (FDO) are well-established treatment options, their mathematical relationship remain largely unclear. The aim of the study was (1) to describe the close mathematical relationship between the SCOT and FDO and (2) to analyze and introduce a novel technique—the stepped FDO—as a modification of the classic FDO. The mathematical background and relationship of SCOT and FDO are described for the example of a femoral deformity correction and visualized using a 3D surface model taking into account the benefits for the clinical application. The novel modifications of the stepped FDO are introduced and its technical and clinical feasibility demonstrated. Both, SCOT and FDO, rely on the same deformity axis that defines the rotation axis k for a 3D deformity correction. To achieve the desired correction using a SCOT, the resulting cutting plane is perpendicular to k, while using a FDO will result in a cylindrical cut with a central axis parallel to k. The SCOT and FDO demonstrate a strong mathematical relation, as both methods rely on the same deformity axis, however, resulting in different cutting planes. These characteristics enable a complementary use when defining the optimal type of osteotomy. This understanding enables a more versatile planning approach when considering factors as the surgical approach, biomechanical characteristics of fixation or soft tissue conditions. The newly introduced stepped FDO facilitates an exact reduction of the bone fragments and potentially expands the clinical applicability of the FDO.
- 4 June 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
Open AccessDome versus single-cut osteotomies for correction of long bone deformities—technical considerations
Corrective osteotomy allows to improve joint loading, pain and function. In complex deformities, the biggest challenge is to define the optimal surgical solution, while considering anatomical, technical and biomechanical factors. While the single-cut osteotomy (SCOT) and focal dome osteotomy (FDO) are well-established treatment options, their mathematical relationship remain largely unclear. The aim of the study was (1) to describe the close mathematical relationship between the SCOT and FDO and (2) to analyze and introduce a novel technique—the stepped FDO—as a modification of the classic FDO. The mathematical background and relationship of SCOT and FDO are described for the example of a femoral deformity correction and visualized using a 3D surface model taking into account the benefits for the clinical application. The novel modifications of the stepped FDO are introduced and its technical and clinical feasibility demonstrated. Both, SCOT and FDO, rely on the same deformity axis that defines the rotation axis k for a 3D deformity correction. To achieve the desired correction using a SCOT, the resulting cutting plane is perpendicular to k, while using a FDO will result in a cylindrical cut with a central axis parallel to k. The SCOT and FDO demonstrate a strong mathematical relation, as both methods rely on the same deformity axis, however, resulting in different cutting planes. These characteristics enable a complementary use when defining the optimal type of osteotomy. This understanding enables a more versatile planning approach when considering factors as the surgical approach, biomechanical characteristics of fixation or soft tissue conditions. The newly introduced stepped FDO facilitates an exact reduction of the bone fragments and potentially expands the clinical applicability of the FDO.
- Open Access
- 28 July 2023
- Published by Elsevier in JSES International
- Vol. 7 (6) , 2321-2329
Computer-assisted planning vs. conventional surgery for the correction of symptomatic mid-shaft clavicular nonunion and malunion
- 28 July 2023
- Published by Elsevier in JSES International
- Vol. 7 (6) , 2321-2329
Open AccessComputer-assisted planning vs. conventional surgery for the correction of symptomatic mid-shaft clavicular nonunion and malunion
- Open Access
- 16 June 2023
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (1) , 145-150
Combined Anteversion Threshold to Avoid Anterior Dislocation in Primary Total Hip Arthroplasty Performed Through the Direct Anterior Approach
- 16 June 2023
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (1) , 145-150
Open AccessCombined Anteversion Threshold to Avoid Anterior Dislocation in Primary Total Hip Arthroplasty Performed Through the Direct Anterior Approach
- Open Access
- 22 March 2023
- Published by Elsevier in JSES International
- Vol. 7 (4) , 550-554
MRI findings of traumatic and degenerative rotator cuff tears and introduction of the “cobra sign”
- 22 March 2023
- Published by Elsevier in JSES International
- Vol. 7 (4) , 550-554
Open AccessMRI findings of traumatic and degenerative rotator cuff tears and introduction of the “cobra sign”
- Open Access
- 27 August 2022
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 41 (4) , 727-736
Malunion deformity of the forearm: Three‐dimensional length variation of interosseous membrane and bone collision
It remains unclear to what extent the interosseous membrane (IOM) is affected through the whole range of motion (ROM) in posttraumatic deformities of the forearm. The purpose of this study is to describe the ligament‐ and bone‐related factors involved in rotational deficit of the forearm. Through three‐dimensional (3D) kinematic simulations on one cadaveric forearm, angular deformities of 5° in four directions (flexion, extension, valgus, varus) were produced at two locations of the radius and the ulna (proximal and distal third). The occurrence of bone collision in pronation and the linear length variation of six parts of the IOM through the whole ROM were compared between the 32 types of forearm deformities. Similar patterns could be observed among four groups: 12 types of deformity presented increased bone collision in pronation, 8 presented an improvement of bone collision with an increase of the mean linear lengthening of the IOM in neutral rotation, 6 had an increased linear lengthening of the IOM in supination with nearly unchanged bone collision in pronation and 6 types presented nearly unchanged bone collision in pronation with a shortening of the mean linear length of IOM in supination or neutral rotation. This kinematic analysis provides a better understanding of the ligament‐ and bone‐related factors expected to cause rotational deficit in forearm deformity and may help to refine the surgical indications of patient‐specific corrective osteotomy.
- 27 August 2022
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 41 (4) , 727-736
Open AccessMalunion deformity of the forearm: Three‐dimensional length variation of interosseous membrane and bone collision
It remains unclear to what extent the interosseous membrane (IOM) is affected through the whole range of motion (ROM) in posttraumatic deformities of the forearm. The purpose of this study is to describe the ligament‐ and bone‐related factors involved in rotational deficit of the forearm. Through three‐dimensional (3D) kinematic simulations on one cadaveric forearm, angular deformities of 5° in four directions (flexion, extension, valgus, varus) were produced at two locations of the radius and the ulna (proximal and distal third). The occurrence of bone collision in pronation and the linear length variation of six parts of the IOM through the whole ROM were compared between the 32 types of forearm deformities. Similar patterns could be observed among four groups: 12 types of deformity presented increased bone collision in pronation, 8 presented an improvement of bone collision with an increase of the mean linear lengthening of the IOM in neutral rotation, 6 had an increased linear lengthening of the IOM in supination with nearly unchanged bone collision in pronation and 6 types presented nearly unchanged bone collision in pronation with a shortening of the mean linear length of IOM in supination or neutral rotation. This kinematic analysis provides a better understanding of the ligament‐ and bone‐related factors expected to cause rotational deficit in forearm deformity and may help to refine the surgical indications of patient‐specific corrective osteotomy.