YCYi Chen

Yi Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yi Chen has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A method for predicting sensitivity of spherical hydrophones at high hydrostatic pressures and its experimental validations

    by Guanghui Jia, Yi Chen, Juan Tu, Dong Zhang

    A method for predicting sensitivity of spherical hydrophones at high hydrostatic pressures is developed based on their impedances without acoustic environments. In this approach, the receiving performance of a spherical hydrophone is modelled as an equivalent circuit, and the relationship between the sensitivity and the parameters of the equivalent circuit is established. To accurately obtain these parameters, these impedances of spherical hydrophones at different hydrostatic pressures are measured, and the parameter matrix of the equivalent circuit is evaluated by the nonlinear evaluation solution of the Levenberg-Marquardt algorithm. The evaluated parameter matrix is applied to calculate the sensitivity of spherical hydrophones. To examine the validity of this method, the sensitivities of the spherical piezoelectric hydrophones of RHS 30 and RHS 20 were predicted at hydrostatic pressures from 2 to 8 MPa and compared with the measured results by free-field measurement facility in a vessel. The predicting results agreed well with the measured ones with the maximum deviation less than 8% in the operation frequency range. In addition, the advantages and limitations of this method are discussed. This method is promising in the study of measuring deep ocean performances of hydrophones in a laboratory.


  • Mechanosensitive Ca 2+ channel TRPV1 activated by low‐intensity pulsed ultrasound ameliorates acute kidney injury through Notch1‐Akt‐ eNOS signaling

    by Qi Huangfu, Jun Zhang, Jiaju Xu, Jinming Xu, Zhangcheng Yang, Jingchao Wei, Liuqing Yang, Yichang Shu, Chengfang Sun, Bohan Wang, et al.

    Acute Kidney Injury (AKI) is a significant medical condition characterized by the abrupt decline in kidney function.Low‐intensity pulsed ultrasound (LIPUS), a non‐invasive therapeutic technique employing low‐intensity acoustic wave pulses, has shown promise in promoting tissue repair and regeneration. A novel LIPUS system was developed and evaluated in rat AKI models, focusing on its effects on glomerular filtration rate (GFR), blood urea nitrogen (BUN), serum creatinine (SCr), and the Notch1‐Akt‐eNOS signaling pathway. The results demonstrated that LIPUS treatment improved GFR, BUN, SCr levels, and renal pathology in AKI rats. In vitro experiments using HUVEC cells revealed that LIPUS stimulation promoted angiogenesis, cell migration mechanically‐dependent calcium ion influx, which was partially attenuated by TRPV1 knockdown. RNA sequencing analysis indicated LIPUS‐induced activation of the Notch pathway, phosphorylation of Akt and eNOS. Furthermore, inhibition or genetic silencing of Notch1 abolished the beneficial effects of LIPUS on angiogenesis, renal function, and Akt‐eNOS phosphorylation in both cells and AKI rats. These findings suggest that LIPUS‐induced calcium influx promotes Akt‐eNOS phosphorylation, nitric oxide (NO) production, angiogenesis, and improved renal function in AKI via Notch1‐Akt‐eNOS signaling, positioning LIPUS as a promising therapeutic strategy for AKI by targeting vascular regeneration.


  • A reciprocity calibration of hydrophones in a non-anechoic water tank: Method and realization

    by Liuqing Yang, Yi Chen, Yongjun Huang, Jun Zhang

    To measure the electroacoustic parameters of transducers in the continuous sound field in a limited water area, a reciprocity calibration method of hydrophones using a spatial sampling average method in a non-anechoic tank was developed. The sound propagation in the non-anechoic tank under the impedance boundary condition, with a sound source producing continuous sound, is introduced based on the Helmholtz equation and Green's function. The reciprocity constant is given using the spatial sampling average sound pressure, and the three-transducer reciprocity calibration procedure was established. The number of spatial sampling points, which must be not less than 6000, and the sampling configuration in the non-anechoic tank are determined. In the non-anechoic tank of 15 m × 9 m × 6 m, the sensitivity of the hydrophone in the frequency range of 250 Hz to 10 kHz was calibrated, and the largest discrepancy between the measurement results from the reciprocity calibration method in the non-anechoic water tank and the standard facility was 0.7 dB.


  • A primary wideband calibration method for noise hydrophones based on three-transducer spherical wave reciprocity in the frequency domain

    by Guanghui Jia, Yi Chen, Juan Tu, Dong Zhang

    A primary wideband calibration method for noise hydrophones is developed, which can be applied to obtain noise acoustic spectral density sensitivity in the free-field. In this method, a wideband three-transducer spherical wave reciprocity calibration method is proposed in the frequency domain. A lowpass spatial domain filter is utilized to eliminate the reflecting acoustic waves from boundaries and water surface, and the wideband frequency responses of the transducer pair are calculated. Wideband calibrations are performed in a laboratory anechoic water tank, and two hydrophones with different reference sensitivities are calibrated in the frequency range of 250 Hz to 20 kHz using noise signals. The decidecade band sensitivities are obtained by the primary wideband calibration, which is in agreement with the single frequency sensitivities. The expended uncertainty of the primary wideband calibration is analyzed and estimated to be 8.9% (k = 2).


  • Results of Pilot Comparisons of Amplitude–Phase Calibrations of Hydrophones in the Frequency Range 10–500 kHz COOMET 786/RU-a/19

    by A. E. Isaev, C. Yi, A. N. Matveev, J. Guanghui, B. I. Khatamtaev, W. Shiquan, N. G. Shcherblyuk


  • Phase-shifted Sensitivity Calibration of Fiber Optic Vector Hydrophone Based on Heterodyne Method

    by Wenjing Li, Yi Chen, Jun Zhang

    In order to realize the calibration of fiber optic vector hydrophone with wide frequency band and large dynamic range, the research on the phase-shifted sensitivity calibration technology of fiber vector hydrophone based on heterodyne method has been carried out. The heterodyne-arctangent demodulation simulations were performed on signals with a large amplitude of 120 rad or a high frequency of 50 kHz respectively, which verified that the demodulation algorithm has the ability to demodulate signals with a wide frequency band or a large dynamic range. A phase-shifted sensitivity calibration system based on the heterodyne method was developed, and the standing wave tube comparison method was used to calibrate the phase-shifted sensitivity of fiber optic vector hydrophones in the frequency band of 20 Hz to 1.25 kHz. Below the resonant frequency of the fiber optic vector hydrophone, the maximum difference between the calibration result and the theoretical calculation result is 1.2 dB, and the measurement uncertainty of the calibration system is 1.5 dB (k = 2).


  • Open Access

    Modelling, measurement and optimization of self-noise of hydrophone with preamplifier

    by Yi Chen, Lisheng Zhou, Xiyang Guo, Tao He, Jun Zhang

    Self-noise is an important specification of hydrophone with preamplifier. This paper presents the modelling, measurement and optimization of the self-noise of hydrophone with preamplifier. Through analyzing various noise sources of hydrophone and its preamplifier, an effective self-noise model of hydrophone with preamplifier was established, and the self-noise was mainly affected by the hydrophone quality factor, preamplifier noise and thermal noise of preamplifier input resistance. In order to measure the self-noise of hydrophone with preamplifier, a measurement system was constructed and used for measuring the self-noise of a RHSA30 hydrophone which manufactured by Hangzhou Applied Acoustics Research Institute (HAARI) and has a typical sensitivity of -173 dB. After optimization of the self-noise of RHSA30 hydrophone, the measured equivalent noise pressure spectral density level was close to 30 dB at the frequency of 1000 Hz. The measurement results proved that the preamplifier current noise which mainly coming from the Operational Amplifier played a leading role at low frequencies of hydrophone with preamplifier. And some basic principles for self-noise optimization of hydrophone with preamplifier were given at the end.