Jemma Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jemma Brown has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Kirsten Christensen-Jeffries
King’s College London,Biomedical Engineering Department,London,UK,SE1 7EH
10 shared publications - Meng-Xing Tang
Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
9 shared publications - Robert J. Eckersley
Biomedical Engineering Department, Division of Imaging Sciences, King’s College London, London, U.K.
9 shared publications - Sevan Harput
Imperial College London,Department of Bioengineering,London,United Kingdom,SW7 2AZ
9 shared publications - Jiaqi Zhu
Department of Medical Physics and Biomedical Engineering, University College London, London, U.K
7 shared publications Christopher Dunsby
Centre for Pathology, Imperial College London, London, U.K.
6 shared publications
Latest Publications
- Open Access
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2118-2121
Super-Resolution Ultrasound Image Filtering with Machine-Learning to Reduce the Localization Error
Localization-based super-resolution imaging requires accurate detection of spatially isolated microbubbles. The reason for this requirement is that interfering or overlapping signals resulting from multiple microbubbles within the resolution limit can cause position errors. In addition to this, noise and artefacts (e.g. residual tissue signal after tissue-microbubble separation) further reduce the quality and hence the spatial resolution in SR imaging. Therefore, correctly identifying the echoes as noise, single microbubble, multiple microbubbles, or artefact is important.In this study, the use of fast classification methods for identification and rejection of non-single microbubble echoes were demonstrated. Most commonly used supervised classification methods, including Decision Trees, Discriminant Analysis, Logistic Regression, Support Vector Machine, Ensembles, k-Nearest Neighbors, and Naive Bayes, were implemented for filtering artefacts and noise in super-resolution ultrasound images. Results showed that the Ensemble method, explicitly designed to deal with unbalanced data, achieved the best result since most of the localized events are true microbubbles, which is typical for super-resolution imaging datasets.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2118-2121
Open AccessSuper-Resolution Ultrasound Image Filtering with Machine-Learning to Reduce the Localization Error
Localization-based super-resolution imaging requires accurate detection of spatially isolated microbubbles. The reason for this requirement is that interfering or overlapping signals resulting from multiple microbubbles within the resolution limit can cause position errors. In addition to this, noise and artefacts (e.g. residual tissue signal after tissue-microbubble separation) further reduce the quality and hence the spatial resolution in SR imaging. Therefore, correctly identifying the echoes as noise, single microbubble, multiple microbubbles, or artefact is important.In this study, the use of fast classification methods for identification and rejection of non-single microbubble echoes were demonstrated. Most commonly used supervised classification methods, including Decision Trees, Discriminant Analysis, Logistic Regression, Support Vector Machine, Ensembles, k-Nearest Neighbors, and Naive Bayes, were implemented for filtering artefacts and noise in super-resolution ultrasound images. Results showed that the Ensemble method, explicitly designed to deal with unbalanced data, achieved the best result since most of the localized events are true microbubbles, which is typical for super-resolution imaging datasets.
- Open Access
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 372-375
Minimization of Nanodroplet Activation Time using Focused-Pulses for Droplet-Based Ultrasound Super-Resolution Imaging
One of the crucial challenges in the application of ultrasound super-resolution imaging using microbubble contrast agents to the clinic is the long acquisition time. Recently acoustic wave sparsely activated localization microscopy (AWSALM) was developed to activate, image, and destroy nanodroplets to achieve ultrasound super-resolution imaging. The activation and destruction of nanodroplets using focused pulses in AWSALM can generate new localization signals without relying on flow and shows the potential to achieve faster ultrasound super-resolution. However, the technique requires optimization to achieve good activation efficiency with the minimum amount of activation time.This work investigates how the different activation strategies affect the activation time and efficiency. A range of activation sequences with different F-numbers and spacing between transmit foci are used and their activation efficiency and the data acquisition time are quantified. The results show that sweeping the focus of the activation pulse with an F-number of 0.4 and a step size of 2.5 wavelengths can generate the highest droplet activation. By using a larger or smaller spacing between consecutive focused activation beams generated lower contrast, which suggests that densely spaced activation pulses may destroy the activated nanodroplets generated by the previous activation pulse. In summary, this study demonstrates that the rate of activation of nanodroplets can be increased by optimizing the F-number and the sweep step size. This finding can inform the development of droplet-based super-resolution imaging to further minimize the data acquisition time.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 372-375
Open AccessMinimization of Nanodroplet Activation Time using Focused-Pulses for Droplet-Based Ultrasound Super-Resolution Imaging
One of the crucial challenges in the application of ultrasound super-resolution imaging using microbubble contrast agents to the clinic is the long acquisition time. Recently acoustic wave sparsely activated localization microscopy (AWSALM) was developed to activate, image, and destroy nanodroplets to achieve ultrasound super-resolution imaging. The activation and destruction of nanodroplets using focused pulses in AWSALM can generate new localization signals without relying on flow and shows the potential to achieve faster ultrasound super-resolution. However, the technique requires optimization to achieve good activation efficiency with the minimum amount of activation time.This work investigates how the different activation strategies affect the activation time and efficiency. A range of activation sequences with different F-numbers and spacing between transmit foci are used and their activation efficiency and the data acquisition time are quantified. The results show that sweeping the focus of the activation pulse with an F-number of 0.4 and a step size of 2.5 wavelengths can generate the highest droplet activation. By using a larger or smaller spacing between consecutive focused activation beams generated lower contrast, which suggests that densely spaced activation pulses may destroy the activated nanodroplets generated by the previous activation pulse. In summary, this study demonstrates that the rate of activation of nanodroplets can be increased by optimizing the F-number and the sweep step size. This finding can inform the development of droplet-based super-resolution imaging to further minimize the data acquisition time.
- Open Access
- 25 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (2) , 269-277
3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
High-frame-rate 3-D ultrasound imaging technology combined with super-resolution processing method can visualize 3-D microvascular structures by overcoming the diffraction-limited resolution in every spatial direction. However, 3-D super-resolution ultrasound imaging using a full 2-D array requires a system with a large number of independent channels, the design of which might be impractical due to the high cost, complexity, and volume of data produced. In this study, a 2-D sparse array was designed and fabricated with 512 elements chosen from a density-tapered 2-D spiral layout. High-frame-rate volumetric imaging was performed using two synchronized ULA-OP 256 research scanners. Volumetric images were constructed by coherently compounding nine-angle plane waves acquired at a pulse repetition frequency of 4500 Hz. Localization-based 3-D super-resolution images of two touching subwavelength tubes were generated from 6000 volumes acquired in 12 s. Finally, this work demonstrates the feasibility of 3-D super-resolution imaging and super-resolved velocity mapping using a customized 2-D sparse array transducer.
- 25 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (2) , 269-277
Open Access3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
High-frame-rate 3-D ultrasound imaging technology combined with super-resolution processing method can visualize 3-D microvascular structures by overcoming the diffraction-limited resolution in every spatial direction. However, 3-D super-resolution ultrasound imaging using a full 2-D array requires a system with a large number of independent channels, the design of which might be impractical due to the high cost, complexity, and volume of data produced. In this study, a 2-D sparse array was designed and fabricated with 512 elements chosen from a density-tapered 2-D spiral layout. High-frame-rate volumetric imaging was performed using two synchronized ULA-OP 256 research scanners. Volumetric images were constructed by coherently compounding nine-angle plane waves acquired at a pulse repetition frequency of 4500 Hz. Localization-based 3-D super-resolution images of two touching subwavelength tubes were generated from 6000 volumes acquired in 12 s. Finally, this work demonstrates the feasibility of 3-D super-resolution imaging and super-resolved velocity mapping using a customized 2-D sparse array transducer.
- Open Access
- 1 June 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 291 (3) , 642-650
3D Super-Resolution US Imaging of Rabbit Lymph Node Vasculature in Vivo by Using Microbubbles
By using microbubbles, three-dimensional super-resolution US in vivo imaging of rabbit lymph nodes visualizes the complex microvascular network and blood flow dynamics with a resolution well beyond the wave diffraction limit, giving the ability to resolve microvessels 30 µm apart. Background Variations in lymph node (LN) microcirculation can be indicative of metastasis. The identification and quantification of metastatic LNs remains essential for prognosis and treatment planning, but a reliable noninvasive imaging technique is lacking. Three-dimensional super-resolution (SR) US has shown potential to noninvasively visualize microvascular networks in vivo. Purpose To study the feasibility of three-dimensional SR US imaging of rabbit LN microvascular structure and blood flow by using microbubbles. Materials and Methods In vivo studies were carried out to image popliteal LNs of two healthy male New Zealand white rabbits aged 6–8 weeks. Three-dimensional, high-frame-rate, contrast material–enhanced US was achieved by mechanically scanning with a linear imaging probe. Individual microbubbles were identified, localized, and tracked to form three-dimensional SR images and super-resolved velocity maps. Acoustic subaperture processing was used to improve image contrast and to generate enhan...
- 1 June 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 291 (3) , 642-650
Open Access3D Super-Resolution US Imaging of Rabbit Lymph Node Vasculature in Vivo by Using Microbubbles
By using microbubbles, three-dimensional super-resolution US in vivo imaging of rabbit lymph nodes visualizes the complex microvascular network and blood flow dynamics with a resolution well beyond the wave diffraction limit, giving the ability to resolve microvessels 30 µm apart. Background Variations in lymph node (LN) microcirculation can be indicative of metastasis. The identification and quantification of metastatic LNs remains essential for prognosis and treatment planning, but a reliable noninvasive imaging technique is lacking. Three-dimensional super-resolution (SR) US has shown potential to noninvasively visualize microvascular networks in vivo. Purpose To study the feasibility of three-dimensional SR US imaging of rabbit LN microvascular structure and blood flow by using microbubbles. Materials and Methods In vivo studies were carried out to image popliteal LNs of two healthy male New Zealand white rabbits aged 6–8 weeks. Three-dimensional, high-frame-rate, contrast material–enhanced US was achieved by mechanically scanning with a linear imaging probe. Individual microbubbles were identified, localized, and tracked to form three-dimensional SR images and super-resolved velocity maps. Acoustic subaperture processing was used to improve image contrast and to generate enhan...
- 17 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (7) , 1246-1254
Poisson Statistical Model of Ultrasound Super-Resolution Imaging Acquisition Time
A number of acoustic super-resolution techniques have recently been developed to visualize microvascular structure and flow beyond the diffraction limit. A crucial aspect of all ultrasound (US) super-resolution (SR) methods using single microbubble localization is time-efficient detection of individual bubble signals. Due to the need for bubbles to circulate through the vasculature during acquisition, slow flows associated with the microcirculation limit the minimum acquisition time needed to obtain adequate spatial information. Here, a model is developed to investigate the combined effects of imaging parameters, bubble signal density, and vascular flow on SR image acquisition time. We find that the estimated minimum time needed for SR increases for slower blood velocities and greater resolution improvement. To improve SR from a resolution of λ/10 to λ/20 while imaging the microvasculature structure modeled here, the estimated minimum acquisition time increases by a factor of 14. The maximum useful imaging frame rate to provide new spatial information in each image is set by the bubble velocity at low blood flows (<;150 mm/s for a depth of 5 cm) and by the acoustic wave velocity at higher bubble velocities. Furthermore, the image acquisition procedure, transmit frequency, localization precision, and desired super-resolved image contrast together determine the optimal acquisition time achievable for fixed flow velocity. Exploring the effects of both system parameters and details of the target vasculature can allow a better choice of acquisition settings and provide improved understanding of the completeness of SR information.
- 17 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (7) , 1246-1254
Poisson Statistical Model of Ultrasound Super-Resolution Imaging Acquisition Time
A number of acoustic super-resolution techniques have recently been developed to visualize microvascular structure and flow beyond the diffraction limit. A crucial aspect of all ultrasound (US) super-resolution (SR) methods using single microbubble localization is time-efficient detection of individual bubble signals. Due to the need for bubbles to circulate through the vasculature during acquisition, slow flows associated with the microcirculation limit the minimum acquisition time needed to obtain adequate spatial information. Here, a model is developed to investigate the combined effects of imaging parameters, bubble signal density, and vascular flow on SR image acquisition time. We find that the estimated minimum time needed for SR increases for slower blood velocities and greater resolution improvement. To improve SR from a resolution of λ/10 to λ/20 while imaging the microvasculature structure modeled here, the estimated minimum acquisition time increases by a factor of 14. The maximum useful imaging frame rate to provide new spatial information in each image is set by the bubble velocity at low blood flows (<;150 mm/s for a depth of 5 cm) and by the acoustic wave velocity at higher bubble velocities. Furthermore, the image acquisition procedure, transmit frequency, localization precision, and desired super-resolved image contrast together determine the optimal acquisition time achievable for fixed flow velocity. Exploring the effects of both system parameters and details of the target vasculature can allow a better choice of acquisition settings and provide improved understanding of the completeness of SR information.
- Open Access
- 25 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (6) , 1039-1046
Fast Acoustic Wave Sparsely Activated Localization Microscopy: Ultrasound Super-Resolution Using Plane-Wave Activation of Nanodroplets
Localization-based ultrasound super-resolution imaging using microbubble contrast agents and phase-change nano-droplets has been developed to visualize microvascular structures beyond the diffraction limit. However, the long data acquisition time makes the clinical translation more challenging. In this study, fast acoustic wave sparsely activated localization microscopy (fast-AWSALM) was developed to achieve super-resolved frames with sub-second temporal resolution, by using low-boiling-point octafluoropropane nanodroplets and high frame rate plane waves for activation, destruction, as well as imaging. Fast-AWSALM was demonstrated on an in vitro microvascular phantom to super-resolve structures that could not be resolved by conventional B-mode imaging. The effects of the temperature and mechanical index on fast-AWSALM was investigated. Experimental results show that sub-wavelength micro-structures as small as 190 lm were resolvable in 200 ms with plane-wave transmission at a center frequency of 3.5 MHz and a pulse repetition frequency of 5000 Hz. This is about a 3.5 fold reduction in point spread function full-width-half-maximum compared to that measured in conventional B-mode, and two orders of magnitude faster than the recently reported AWSALM under a non-flow/very slow flow situations and other localization based methods. Just as in AWSALM, fast-AWSALM does not require flow, as is required by current microbubble based ultrasound super resolution techniques. In conclusion, this study shows the promise of fast-AWSALM, a super-resolution ultrasound technique using nanodroplets, which can generate super-resolution images in milli-seconds and does not require flow.
- 25 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (6) , 1039-1046
Open AccessFast Acoustic Wave Sparsely Activated Localization Microscopy: Ultrasound Super-Resolution Using Plane-Wave Activation of Nanodroplets
Localization-based ultrasound super-resolution imaging using microbubble contrast agents and phase-change nano-droplets has been developed to visualize microvascular structures beyond the diffraction limit. However, the long data acquisition time makes the clinical translation more challenging. In this study, fast acoustic wave sparsely activated localization microscopy (fast-AWSALM) was developed to achieve super-resolved frames with sub-second temporal resolution, by using low-boiling-point octafluoropropane nanodroplets and high frame rate plane waves for activation, destruction, as well as imaging. Fast-AWSALM was demonstrated on an in vitro microvascular phantom to super-resolve structures that could not be resolved by conventional B-mode imaging. The effects of the temperature and mechanical index on fast-AWSALM was investigated. Experimental results show that sub-wavelength micro-structures as small as 190 lm were resolvable in 200 ms with plane-wave transmission at a center frequency of 3.5 MHz and a pulse repetition frequency of 5000 Hz. This is about a 3.5 fold reduction in point spread function full-width-half-maximum compared to that measured in conventional B-mode, and two orders of magnitude faster than the recently reported AWSALM under a non-flow/very slow flow situations and other localization based methods. Just as in AWSALM, fast-AWSALM does not require flow, as is required by current microbubble based ultrasound super resolution techniques. In conclusion, this study shows the promise of fast-AWSALM, a super-resolution ultrasound technique using nanodroplets, which can generate super-resolution images in milli-seconds and does not require flow.
- 24 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (4) , 676-691
Investigation of Microbubble Detection Methods for Super-Resolution Imaging of Microvasculature
Ultrasound super-resolution techniques use the response of microbubble contrast agents (MBs) to visualize the microvasculature. Techniques that localize isolated bubble signals first require detection algorithms to separate the MB and tissue responses. This work explores the three main MB detection techniques for super-resolution of microvasculature. Pulse inversion (PI), differential imaging (DI) and singular value decomposition (SVD) filtering were compared in terms of the localization accuracy, precision and contrast to tissue ratio (CTR). MB responses were simulated based on the properties of Sonovue™ and using the Marmottant model. Non-linear propagation through tissue was modelled using the k-Wave software package. For the parameters studied, the results show that PI is most appropriate for low frequency applications, but also most dependent on transducer bandwidth. SVD is preferable for high frequency acquisition where localization precision on the order of a few microns is possible. PI is largely independent of flow direction and speed compared to SVD and DI, so is appropriate for visualizing the slowest flows and tortuous vasculature. SVD is unsuitable for stationary MBs and can introduce a localization error on the order of hundreds of microns over the speed range 0- 2 mm/s and flow directions from lateral (parallel to probe) to axial (perpendicular to probe). DI is only suitable for flow rates > 0.5 mm/s or as flow becomes more axial. Overall, this study develops a MB and tissue non-linear simulation platform to improve understanding of how different MB detection techniques can impact the super-resolution process and explores some of the factors influencing the suitability of each.
- 24 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (4) , 676-691
Investigation of Microbubble Detection Methods for Super-Resolution Imaging of Microvasculature
Ultrasound super-resolution techniques use the response of microbubble contrast agents (MBs) to visualize the microvasculature. Techniques that localize isolated bubble signals first require detection algorithms to separate the MB and tissue responses. This work explores the three main MB detection techniques for super-resolution of microvasculature. Pulse inversion (PI), differential imaging (DI) and singular value decomposition (SVD) filtering were compared in terms of the localization accuracy, precision and contrast to tissue ratio (CTR). MB responses were simulated based on the properties of Sonovue™ and using the Marmottant model. Non-linear propagation through tissue was modelled using the k-Wave software package. For the parameters studied, the results show that PI is most appropriate for low frequency applications, but also most dependent on transducer bandwidth. SVD is preferable for high frequency acquisition where localization precision on the order of a few microns is possible. PI is largely independent of flow direction and speed compared to SVD and DI, so is appropriate for visualizing the slowest flows and tortuous vasculature. SVD is unsuitable for stationary MBs and can introduce a localization error on the order of hundreds of microns over the speed range 0- 2 mm/s and flow directions from lateral (parallel to probe) to axial (perpendicular to probe). DI is only suitable for flow rates > 0.5 mm/s or as flow becomes more axial. Overall, this study develops a MB and tissue non-linear simulation platform to improve understanding of how different MB detection techniques can impact the super-resolution process and explores some of the factors influencing the suitability of each.
- Open Access
- 9 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (5) , 803-814
Two-Stage Motion Correction for Super-Resolution Ultrasound Imaging in Human Lower Limb
The structure of microvasculature cannot be resolved using conventional ultrasound (US) imaging due to the fundamental diffraction limit at clinical US frequencies. It is possible to overcome this resolution limitation by localizing individual microbubbles through multiple frames and forming a superresolved image, which usually requires seconds to minutes of acquisition. Over this time interval, motion is inevitable and tissue movement is typically a combination of large- and small-scale tissue translation and deformation. Therefore, super-resolution (SR) imaging is prone to motion artifacts as other imaging modalities based on multiple acquisitions are. This paper investigates the feasibility of a two-stage motion estimation method, which is a combination of affine and nonrigid estimation, for SR US imaging. First, the motion correction accuracy of the proposed method is evaluated using simulations with increasing complexity of motion. A mean absolute error of 12.2 $\mu \text{m}$ was achieved in simulations for the worst-case scenario. The motion correction algorithm was then applied to a clinical data set to demonstrate its potential to enable in vivo SR US imaging in the presence of patient motion. The size of the identified microvessels from the clinical SR images was measured to assess the feasibility of the two-stage motion correction method, which reduced the width of the motion-blurred microvessels to approximately 1.5-fold.- 9 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (5) , 803-814
Open AccessTwo-Stage Motion Correction for Super-Resolution Ultrasound Imaging in Human Lower Limb
The structure of microvasculature cannot be resolved using conventional ultrasound (US) imaging due to the fundamental diffraction limit at clinical US frequencies. It is possible to overcome this resolution limitation by localizing individual microbubbles through multiple frames and forming a superresolved image, which usually requires seconds to minutes of acquisition. Over this time interval, motion is inevitable and tissue movement is typically a combination of large- and small-scale tissue translation and deformation. Therefore, super-resolution (SR) imaging is prone to motion artifacts as other imaging modalities based on multiple acquisitions are. This paper investigates the feasibility of a two-stage motion estimation method, which is a combination of affine and nonrigid estimation, for SR US imaging. First, the motion correction accuracy of the proposed method is evaluated using simulations with increasing complexity of motion. A mean absolute error of 12.2 $\mu \text{m}$ was achieved in simulations for the worst-case scenario. The motion correction algorithm was then applied to a clinical data set to demonstrate its potential to enable in vivo SR US imaging in the presence of patient motion. The size of the identified microvessels from the clinical SR images was measured to assess the feasibility of the two-stage motion correction method, which reduced the width of the motion-blurred microvessels to approximately 1.5-fold. - Open Access
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Ultrasound super-resolution with microbubble contrast agents
Ultrasound super-resolution imaging can be achieved by localizing spatially isolated microbubble contrast agents over multiple imaging frames. In vivo images with resolutions of ~10-20 microns in deep tissue have been demonstrated. The technique has the potential to revolutionize the way micro-circulation can be visualized and quantified, and has implications in a wide range of clinical applications including cancer, diabetes and beyond. In this paper we describe the principle of the technique with in vivo results demonstrating the superior resolution achieved compared with existing ultrasound imaging. We also discuss the challenges and opportunities in the area of 3D imaging including, imaging speed, tissue motion and microbubble localization errors.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Open AccessUltrasound super-resolution with microbubble contrast agents
Ultrasound super-resolution imaging can be achieved by localizing spatially isolated microbubble contrast agents over multiple imaging frames. In vivo images with resolutions of ~10-20 microns in deep tissue have been demonstrated. The technique has the potential to revolutionize the way micro-circulation can be visualized and quantified, and has implications in a wide range of clinical applications including cancer, diabetes and beyond. In this paper we describe the principle of the technique with in vivo results demonstrating the superior resolution achieved compared with existing ultrasound imaging. We also discuss the challenges and opportunities in the area of 3D imaging including, imaging speed, tissue motion and microbubble localization errors.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Notice of Removal: Automated super-resolution image processing in ultrasound using machine learning
Removed.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Notice of Removal: Automated super-resolution image processing in ultrasound using machine learning
Removed.