FAFederico Aprile

Federico Aprile

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Federico Aprile has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The role of cochlear implant positioning on MR imaging quality: a preclinical in vivo study with a novel implant magnet system

    by Pietro Canzi, Marianna Magnetto, Anna Simoncelli, Marco Manfrin, Federico Aprile, Elvis Lafe, Elena Carlotto, Irene Avato, Andrea Scribante, Lorenzo Preda, et al.

    Purposes: To investigate the effects for Ultra 3D cochlear implant (CI) positioning on MR imaging quality, looking at a comprehensive description of intracranial structures in cases of unilateral and bilateral CI placement. Methods: Four CI angular positions (90°, 120°, 135° and 160°) at 9 cm distance from the outer-ear canal were explored. The 1.5 T MRI assessment included our institutional protocol for the investigation of brain pathologies without gadolinium application. Three investigators (two experienced neuroradiologists and one experienced otoneurosurgeon) independently evaluated the MR findings. A 4-point scale was adopted to describe 14 intracranial structures and to determine which CI positioning allowed the best image quality score and how bilateral CI placement modified MRI scan visibility. Results: A high positive correlation was found between the three blinded observers. Structures situated contralateral from the CI showed high-quality values in all four placements. Structures situated ipsilaterally provided results suitable for diagnostic purposes for at least one position. At 90°, artifacts mainly involved brain structures located cranially and anteriorly (e.g., temporal lobe); on the contrary, at 160°, artifacts mostly influenced the posterior fossa structures (e.g., occipital lobe). For the bilateral CI condition, MR imaging examination revealed additional artifacts involving all structures located close to either CI, where there was a signal void/distortion area. Conclusions: Suitable unilateral CI positioning can allow the visualization of intracranial structures with sufficient visibility for diagnostic purposes. Bilateral CI positioning significantly deteriorates the anatomical visibility. CI positioning might play a crucial role for patients who need post-operative MRI surveillance.


  • Surgical tracheotomy in COVID-19 patients: an Italian single centre experience

    by Roberto Briatore, Federico Aprile, Agostino Roasio, Alessandro Bianchi, Stefano Bosso, Livio Carmino, Laura Lorenzelli, Martina Scanu, Mattia Zanin, Giuseppina Bosso, et al.

    Purpose Coronavirus infection disease 2019 (COVID-19) causes in 10% of patients a severe respiratory distress syndrome managed with invasive mechanical ventilation (IMV), sometimes difficult to wean. The role of tracheotomy is debated for the possible risks for patients and staff. We are going to describe here our experience with surgical tracheotomy in COVID-19 positive patients. Methods We enrolled all intensive care unit (ICU) patients requiring longer than 10 days of IMV. Demographic, clinical, respiratory, complications, and outcomes data were collected, in a particular length of weaning from sedation and IMV, in-ICU and in-hospital mortality rate. All healthcare operators involved were tested for SARS-CoV2 by pharyngeal swab and blood test (antibody test). Results 13 out of 68 ICU patients (19.1%) underwent surgical tracheotomy after a median intubation period of 14 days. The mean age was 60 (56–65) years. 85% were male patients. Postoperative mild bleeding was seen in 30.7%, pneumothorax in 7.7%. Mean weaning from sedation required 3 days, 19 days from IMV. In-ICU and in-hospital COVID-infection-related mortality was 23.1% and 30.7%, respectively. None of the healthcare operators was found SARS-CoV2 positive during the period of the study. Conclusions In COVID-19 pandemic surgical tracheotomy enables to wean from sedation and subsequently from IMV in a safe way for both patients and personnel.


  • Open Access

    MRI-induced artifact by a cochlear implant with a novel magnet system: an experimental cadaver study

    by Pietro Canzi, Federico Aprile, Anna Simoncelli, Marco Manfrin, Marianna Magnetto, Elvis Lafe, Domenico Minervini, Irene Avato, Simone Terrani, Andrea Scribante, et al.

    Purposes: To primarily evaluate MRI-induced effects for Ultra 3D cochlear implantation in human cadavers in terms of artifact generation and MR image quality. Methods: Three human cadaveric heads were submitted to imaging after unilateral and bilateral cochlear implantation. The 1.5 T MR examination protocol was chosen in accordance with our institutional protocol for the assessment of brain pathology. The maximal signal void size was measured according to each sequence and plane. Two experienced neuro-radiologists and one experienced otoneurosurgeon independently evaluated the MR image quality findings. A 4-point scale was used to describe the diagnostic usefulness of 14 brain structures. Results: Shape and size of the artifacts were found to be highly related to MRI sequences and acquisition planes. MRI sequences and processing algorithms affected the ability to assess anatomical visibility. Image quality appeared either high or assessable for diagnostic purposes in 9 out of 14 of the ipsilateral structures, in at least one plane. Anatomical structures contralateral to the cochlear implant were highly visible in all conditions. Artifact intrusion clearly improved after application of metal artifact-reduction techniques. In the case of bilateral cochlear implant, a mutual interaction between the two implant magnets produced an additional artifact. Conclusions: We performed the first cadaver study aimed at systematically evaluating the MRI-induced artifacts produced by a cochlear implant with a novel four bar magnet system. Specific brain structures can be assessable for diagnostic purposes under 1.5 T MRI, with the cochlear implant magnet in place.


  • Open Access

    “Emergency” Cochlear Implantation in Labyrinthitis Ossificans Secondary to Polyarteritis Nodosa: How to Face a Rare Entity

    by Lorenzo Cavagna, Marco Benazzo, Pietro Canzi, Federico Aprile, Marco Manfrin, Irene Avato, Marianna Magnetto, Domenico Minervini

    Polyarteritis nodosa (PAN) is a systemic vasculitis affecting the small- and medium-sized arteries that may present with hearing impairment. In rare cases, PAN may be associated with progressive labyrinthitis ossificans (LO), an otologic emergency requiring early cochlear implantation (CI) to restore hearing before the complete, irreversible cochlear ossification. We report the first case in the literature of a patient affected by PAN with bilateral sudden sensorineural hearing loss and rapid LO who underwent “emergency” bilateral simultaneous CI. This case report emphasizes the importance of an early audiological evaluation in patients with PAN when LO is suspected. Multidisciplinary approach is mandatory when facing organ-specific manifestations in patients with PAN. Detailed discussion is provided with particular regard to clinical and radiological presentation as well as CI outcomes in such a rare and challenging case. Cite this article as: Canzi P, Aprile F, Manfrin M, Avato I, Magnetto M, Minervini D, et al. “Emergency” Cochlear Implantation in Labyrinthitis Ossificans Secondary to Polyarteritis Nodosa: How to Face a Rare Entity. J Int Adv Otol 2019; 15(1): 156-9.


  • Open Access

    New frontiers and emerging applications of 3D printing in ENT surgery: a systematic review of the literature

    by P. Canzi, M. Magnetto, S. Marconi, P. Morbini, S. Mauramati, F. Aprile, I. Avato, F. Auricchio, M. Benazzo

    3D printing systems have revolutionised prototyping in the industrial field by lowering production time from days to hours and costs from thousands to just a few dollars. Today, 3D printers are no more confined to prototyping, but are increasingly employed in medical disci- plines with fascinating results, even in many aspects of otorhinolaryngology. All publications on ENT surgery, sourced through updated electronic databases (PubMed, MEDLINE, EMBASE) and published up to March 2017, were examined according to PRISMA guidelines. Overall, 121 studies fulfilled specific inclusion criteria and were included in our systematic review. Studies were classified according to the specific field of application (otologic, rhinologic, head and neck) and area of interest (surgical and preclinical education, customised surgical planning, tissue engineering and implantable prosthesis). Technological aspects, clinical implications and limits of 3D printing processes are discussed focusing on current benefits and future perspectives.


  • Translabyrinthine vestibular neurectomy and simultaneous cochlear implant for Ménière’s disease

    by Pietro Canzi, Marco Manfrin, Marco Perotti, Federico Aprile, Silvia Quaglieri, Elisabetta Rebecchi, Giulia Locatelli, Marco Benazzo

    Surgical management of Ménière’s disease (MD) is recommended in case of medical and intratympanic treatment failures. Translabyrinthine vestibular nerve section has been considered the gold standard for denervation procedures in order to control vertigo attacks, although at the cost of sacrificing residual hearing. To the best of our knowledge, no work has been published with regard to a group of patients submitted to translabyrinthine vestibular neurectomy and simultaneous cochlear implant for MD. The aim of the present study was to assess the effectiveness of translabyrinthine vestibular nerve section and simultaneous cochlear implant in a prospective study. All adult patients (over 18 years of age) with a diagnosis of intractable unilateral definite MD and useless residual hearing function were enrolled after medical and intratympanic treatment failures. Pre- and postoperative otoneurological evaluation concerned: frequency of vertigo attacks, head impulse test and caloric testing, pure tone average and speech perception audiometry in quiet conditions, tinnitus handicap inventory test, functional level scale and rate of vertigo control, dizziness handicap inventory test, and MD patient-oriented severity index. At least 6 months of follow-up were needed to be enrolled in the study. Four patients were included in the study. Translabyrinthine vestibular nerve section and simultaneous cochlear implant seemed to considerably improve the disabling effects of MD, achieving a good control of vestibular symptoms (mean pre/postoperative vertigo attacks per month: 16.5/0), resolving hearing loss (mean pre/postoperative pure tone average in the affected ear: 86.2/32.5 dB), improving the tinnitus (mean pre/postoperative tinnitus handicap inventory test: 77.2/6), and finally increasing the overall quality-of-life parameters. In our preliminary report, translabyrinthine vestibular nerve section and simultaneous cochlear implant showed encouraging results in order to definitively control both vestibular and cochlear symptoms during the same therapeutic procedure.